HomeMy WebLinkAboutFL3607-Compliance Report(1)6�( COMcheck Software Version 4.1.5.1 Interior Lighting Compliance Certificate Project Information Energy Code: Project Title: Project Type: Construction Site: Fort Pierce, FL 34951 Allowed Interior Lighting Power 2017 Florida Building Code, Energy Conservation Autozone Store #3607 Alteration Owner/Agent: Autozone Design and Construction 123 S. Front Street Memphis, TN 38103 Designer/Contractor: Danny Doss Advanced Consulting Engineers, Inc. 132 Kelley Dr Rogers, AR 72757 479-631-1712 acei@advengineers.com A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts / ft2 (B X C) 1-AutoZone (Retail:Sales Area) 7343 1.59 11675 Proposed Interior Lighting Power A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast AutoZone ( Retail:Sales Area 7343 s" LED: A: LED: Other: LED: B: LED: Other: Interior Lighting Compliance Statement Total Allowed Watts = 11675 B C D E Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. 4 56 48 2688 2 62 24 1488 Total Proposed Watts = 4176 Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version 4.1.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Danny E Doss PE ,, 05-18-21 Name - Title Signature 61 Date Project Title: Autozone Store #3607 Report date: 05/18/21 Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 1 of 16 6�( COMcheck Software Version 4.1.5.1 Exterior Lighting Compliance Certificate Project Information Energy Code: Project Title: Project Type: Exterior Lighting Zone Construction Site: Fort Pierce, FL 34951 Allowed Exterior Lighting Power A Area/Surface Category 2017 Florida Building Code, Energy Conservation Autozone Store #3607 Alteration 2 (Residential mixed use area) Owner/Agent: Autozone Design and Construction 123 S. Front Street Memphis, TN 38103 B Quantity Designer/Contractor: Danny Doss Advanced Consulting Engineers, Inc. 132 Kelley Dr Rogers, AR 72757 479-631-1712 acei@advengineers.com C D E Allowed Tradable Allowed Watts Watts / Unit Wattage (B X C) Illuminated area of facade wall or surface 435 ft2 0.1 No 44 Total Tradable Watts (a) = 0 Total Allowed Watts = 44 Total Allowed Supplemental Watts (b) = 600 (a) Wattage tradeoffs are only allowed between tradable areas/surfaces. (b) A supplemental allowance equal to 600 watts may be applied toward compliance of both non -tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. Illuminated area of facade wall or surface (435 ft2): Non -tradable Wattage LED 1: D: LED Other Fixture Unit 40W: 1 1 40 40 Total Tradable Proposed Watts = 0 Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version 4.1.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Danny E Doss PE VJ' I CJ'L I Name Title Signature Date Project Title: Autozone Store #3607 Report date: 05/18/21 Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 2 of 16 6�( COMcheck Software Version 4.1.5.1 Mechanical Compliance Certificate Project Information Energy Code: Project Title: Location: Climate Zone: Project Type: Construction Site: Fort Pierce, FL 34951 Mechanical Systems List Quantity System Type & Description 2017 Florida Building Code, Energy Conservation Autozone Store #3607 Fort Pierce, Florida 2a Alteration Owner/Agent: Autozone Design and Construction 123 S. Front Street Memphis, TN 38103 HVAC System 1 (Single Zone): Single Package Heat Pump Heating Mode: Capacity = 67 kBtu/h, Proposed Efficiency = 3.40 COP, Required Efficiency = 3.30 COP Cooling Mode: Capacity = 71 kBtu/h, Proposed Efficiency = 12.00 EER, Required Efficiency: 11.00 EER + 12.0 IEER Fan System: None Water Heater 1: Electric Instantaneous Water Heater, Capacity: 4 gallons No minimum efficiency requirement applies Mechanical Compliance Statement Designer/Contractor: Danny Doss Advanced Consulting Engineers, Inc. 132 Kelley Dr Rogers, AR 72757 479-631-1712 acei@advengineers.com Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version 4.1.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Danny E Doss PE e V e- "1J-' V-" Name - Title Sign ure Date Project Title: Autozone Store #3607 Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Report date: 05/18/21 Page 3 of 16 eCOMcheck Software Version 4.1.5.1 l�4 Inspection Checklist Energy Code: 2017 Florida Building Code, Energy Conservation Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review � 7 Complies? Comments/Assumptions & Req.ID C103.2 Plans, specifications, and/or ❑Complies Requirement will be met. [PR2]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable determined for the mechanical ❑Not Applicable systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. C103.2 Plans, specifications, and/or ❑Complies Requirement will be met. [PR3]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable determined for the service water ❑Not Applicable heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. C405.6 Plans, specifications, and/or ❑Complies Requirement will be met. [PR17]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable determined for the electrical systems ❑Not Applicable and equipment and document where exceptions are claimed. Provisions are made for metering individual tenant units. Feeder connectors (for feeder and branch circuits) sized in accordance with approved plans with maximum drop of 5% voltage drop total. C103.2 Plans, specifications, and/or ❑Complies Requirement will be met. [PR4]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable determined for the interior lighting ❑Not Applicable and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. 111 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: Autozone Store #3607 Report date: 05/18/21 Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 4 of 16 Section # & Req.ID Plan Review Complies? Comments/Assumptions C103.2 Plans, specifications, and/or ❑Complies Requirement will be met. [PR8]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable determined for the exterior lighting ❑Not Applicable and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Additional Comments/Assumptions: 111 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: Autozone Store #3607 Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Report date: 05/18/21 Page 5 of 16 Section # Footing / Foundation Inspection Complies? Comments/Assumptions & Recl.ID C403.2.4. Snow/ice melting system sensors for ❑Complies Exception: Requirement does not apply. 5, future connection to controls. Freeze ❑Does Not C403.2.4. protection systems have automatic 6 controls installed. ❑Not Observable [FO9]3 ❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: Autozone Store #3607 Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Report date: 05/18/21 Page 6 of 16 Section # Plumbing Rough -In Inspection Complies? Comments/Assumptions & Req.ID C404.5, Heated water supply piping conforms❑Complies Exception: Requirement does not apply. C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. ❑Not Observable, [PL6]3 ❑Not Applicable C404.5, Heated water supply piping conforms ;❑Complies ;Requirement will be met. C404.5.1, to pipe length and volume :❑Does Not C404.5.2 requirements. Refer to section details.❑Not Observable', [PL6]3 j❑Not Applicable C404.6.3 Pumps that circulate water between a ❑Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to ❑Not Observable <= 5 minutes after end of heating ❑Not Applicable cycle. C404.6.3 Pumps that circulate water between a ❑Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to ❑Not Observable', <= 5 minutes after end of heating I❑Not Applicable cycle. C404.7 Water distribution system that pumps ❑Complies Exception: Requirement does not apply. [PL8]3 water from a heated -water supply ❑Does Not pipe back to the heated -water source ❑Not Observable through a cold -water supply pipe is a ❑Not Applicable demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold -water piping to 104°F. C404.7 Water distribution system that pumps ;❑Complies Exception: Requirement does not apply. [PL8]3 water from a heated -water supply :❑Does Not pipe back to the heated -water source : Observable ; I through a cold -water supply pipe is a❑Not Applicable demand recirculation water system. ;❑Not Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold -water piping to 104°F. Additional Comments/Assumptions: 1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: Autozone Store #3607 Report date: 05/18/21 Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 7 of 16 Section # Mechanical Rough -In Inspection Complies? Comments/Assumptions & Req.ID C402.2.6 Thermally ineffective panel surfaces of ❑Complies Exception: Requirement does not apply. [ME41]3 sensible heating panels have ❑Does Not insulation >= R-3.5. ❑Not Observable ❑Not Applicable C403.2.12 HVAC fan systems at design ❑Complies Requirement will be met. .1 conditions do not exceed allowable ❑Does Not [ME65]3 fan system motor nameplate hp or fan ❑Not Observable See the Mechanical Systems list for values. system bhp. ❑Not Applicable C403.2.12 Fans have efficiency grade (FEG) >_ ❑Complies Requirement will be met. .3 67. The total efficiency of the fan at ❑Does Not [ME117]2 the design point of operation <= 15% ❑Not Observable of maximum total efficiency of the ❑Not Applicable fan. C403.2.9. HVAC ducts and plenums insulated ❑Complies Requirement will be met. 1.1 and sealed according to Florida ❑Does Not [ME60]2 Section C403.2.9, Table C403.2.9.1. ❑Not Observable ❑Not Applicable C403.2.9. All ducts, air handlers, filter boxes, ❑Complies Requirement will be met. 2 building cavities, mechanical closets ❑Does Not [ME79]2 and enclosed support platforms that ❑Not Observable form the primary air containment ❑Not Applicable passageways for air distribution systems are constructed and erected in accordance with Table C403.2.9.2 and with Chapter 6 of the Florida Building Code, Mechanical. Ducts are be constructed, braced, reinforced and installed to provide structural strength and durability. All transverse joints, longitudinal seams and fitting connections are securely fastened in accordance with the applicable standards of this section. C403.2.9. Duct insulation is protected from ❑Complies Requirement will be met. 1.2 damage but not limited to the ❑Does Not [ME80]2 following: 1. Insulation exposed to ❑Not Observable weather is suitable for outdoor ❑Not Applicable service. Cellular foam insulation is protected or painted with a coating that is water retardant and provides shielding from solar radiation. 2. Insulation covering cooling ducts located outside the conditioned space is vapor retardant located outside the insulation, all penetrations and joints of which shall be sealed. C403.2.9. Additional insulation with vapor ❑Complies Requirement will be met. 1.3 barrier is provided where the ❑Does Not [ME81]2 minimum duct insulation requirements ❑Not Observable of Section C403.2.9.1.1 are ❑Not Applicable determined to be insufficient to prevent condensation. C403.2.13 Unenclosed spaces that are heated ❑Complies Exception: Requirement does not apply. [ME71]2 use only radiant heat. ❑Does Not ❑Not Observable ❑Not Applicable C403.2.3 HVAC equipment efficiency verified. ❑Complies See the Mechanical Systems list for values. [ME55]2 ❑Does Not ❑Not Observable ❑Not Applicable 111 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Autozone Store #3607 Report date: 05/18/21 Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 8 of 16 Section # Mechanical Rough -In Inspection Complies? Comments/Assumptions & Reci.ID C403.2.9. Ducts, air handlers, filter boxes, ;❑Complies Requirement will be met. 3 building cavities, mechanical closets ❑Does Not [ME10]z and enclosed support platforms that ❑Not Observable , form the primary air containment Applicable passageways for air distribution❑Not systems are sealed in accordance with the applicable criteria of this section and Table C403.2.9.2. C403.2.9. Cavities in framed spaces are not ;❑Complies Requirement will be met. 4 used to deliver air from or return air to :❑Does Not [ME78]2 the conditioning system unless they ❑Not Observable', contain an air duct insert which is Applicable insulated in accordance with Section❑Not j C403.2.9.1 and constructed and sealed in accordance with the requirements of Section C403.2.9.2 appropriate for the duct materials used. C403.2.9. Air distribution systems are sized and❑Complies Requirement will be met. 5 designed in accordance with :❑Does Not [ME76]2 recognized engineering standards. ❑Not Observable' Refer to section details. T❑Not Applicable C403.2.9. Air -handling units not installed in❑Complies Requirement will be met. 6 attics of commercial buildings. ❑Does Not [ME77]2 ❑Not Observable; T❑Not Applicable C408.2.2 Air system balancing accomplished in❑Complies Requirement will be met. 1 a manner to first minimize throttling :❑Does Not [ME53]3 losses, then for fans with fan system ❑Not Observable power greater than 1 hp, fan speeds Applicable shall be adjusted to meet design flow❑Not conditions. Balancing procedures shall be in accordance with NEBB Procedural Standards, the AABC, National Standards, or equivalent procedures. C403.2.6. Demand control ventilation provided ❑Complies Exception: Requirement does not apply. 1 for spaces >500 ft2 and >25 ❑Does Not [ME59]1 people/1000 ft2 occupant density and ❑Not Observable served by systems with air side ❑Not Applicable economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. C403.2.6. Enclosed parking garage ventilation❑Complies Exception: Requirement does not apply. 2 has automatic contaminant detection :❑Does Not [ME115]3 and capacity to stage or modulate fans to 50% or less of design capacity.❑Not j Observable' ❑Not Applicable C403.2.7 Exhaust air energy recovery on❑Complies Exception: Requirement does not apply. [ME57]1 systems meeting Table C403.2.7(1) :❑Does Not and C403.2.7(2). ❑Not Observable ❑Not Applicable C403.2.8 Kitchen exhaust systems comply with❑Complies Exception: Requirement does not apply. [ME11613 replacement air and conditioned :❑Does Not supply air limitations, and satisfy hood ❑Not Observable rating requirements and maximum Applicable exhaust rate criteria.❑Not C403.4.4. Multiple zone VAV systems with DDC❑Complies i , Exception: Requirement does not apply. 6 of individual zone boxes have static ❑Does Not [ME110]3 pressure setpoint reset controls. See the Mechanical Systems list for values. ❑Not Observable; T❑Not Applicable 1 I High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: Autozone Store #3607 Report date: 05/18/21 Data filename: X:\COMCheck Files\Advanced Energy Sol utions\AZRM6447.cck Page 9 of 16 Section # Mechanical Rough -In Inspection Complies? Comments/Assumptions & Req.ID C408.2.2. Air outlets and zone terminal devices❑Complies Requirement will be met. 1 have means for air balancing. :❑Does Not [ME53]3 ❑Not Observable ❑Not Applicable C403.5, Refrigerated display cases, walk-in❑Complies Exception: Requirement does not apply. C403.5.1, coolers or walk-in freezers served by :❑Does Not C403.5.2 remote compressors and remote ❑Not Observable [ME123]3 condensers not located in a Applicable condensing unit, have fan -powered ;❑Not condensers that comply with Sections C403.5.1 and refrigeration compressor; systems that comply with C403.5.2.. j Additional Comments/Assumptions: 1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: Autozone Store #3607 Report date: 05/18/21 Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 10 of 16 Section # Rough -In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.1 Lighting controls installed to uniformly❑Complies Requirement will be met. [EL15]1 reduce the lighting load by at least :❑Does Not 50%.❑Not Observable ❑Not Applicable C405.2.1 Occupancy sensors installed in ;❑Complies Requirement will be met. [EL18]1 required spaces. :❑Does Not ❑Not Observable ❑Not Applicable C405.2.1, Independent lighting controls installed ❑Complies Requirement will be met. C405.2.2. per approved lighting plans and all ❑Does Not 3 manual controls readily accessible and ❑Not Observable [EL23] 2 visible to occupants. ❑Not Applicable C405.2.2. Automatic controls to shut off all❑Complies Requirement will be met. 1 building lighting installed in all :❑Does Not [EL22]2 buildings. ❑Not Observable T❑Not Applicable C405.2.3 Daylight zones provided with❑Complies !Exception: Requirement does not apply. [EL16]2 individual controls that control the :❑Does Not lights independent of general area �Not Observable; ❑ lighting. ❑Not Applicable C405.2.3, Primary sidelighted areas are ;❑Complies !Exception: Requirement does not apply. C405.2.3. equipped with required lighting :❑Does Not 1, C405.2.3. controls. ❑Not Observable; 2 ;❑Not Applicable [EL20]1 C405.2.3, Enclosed spaces with daylight area❑Complies Exception: Requirement does not apply. C405.2.3. under skylights and rooftop monitors :❑Does Not 1, are equipped with required lighting ❑Not Observable C405.2.3. controls. ❑Not Applicable 3 [EL21]1 C405.2.4 Separate lighting control devices for ❑Complies Requirement will be met. [EL4]1 specific uses installed per approved ❑Does Not lighting plans. ❑Not Observable ❑Not Applicable C405.2.4 Additional interior lighting power ❑Complies Requirement will be met. [EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is ❑Not Observable automatically controlled and ❑Not Applicable separated from general lighting. C405.2.5 Automatic lighting controls for exterior;❑Complies Requirement will be met. [EL25]nu° lighting installed. Controls will be :❑Does Not daylight controlled, set based on ❑Not Observable! business operation time -of -day, or Applicable reduce connected lighting > 30% ;❑Not C405.3 Exit signs do not exceed 5 watts per❑Complies Requirement will be met. [EL6]1 face. :❑Does Not ❑Not Observable! ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Autozone Store #3607 Report date: 05/18/21 Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 11 of 16 111 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: Autozone Store #3607 Report date: 05/18/21 Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 12 of 16 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, Furnished O&M instructions for❑Complies Requirement will be met. C408.2.5. systems and equipment to the :❑Does Not 2 [F117]3 building owner or designated representative. ❑Not Observable; ❑Not Applicable C303.3, Furnished O&M manuals for HVAC ;❑Complies ;Requirement will be met. C408.2.5. systems within 90 days of system ❑Does Not 3 [F18]3❑Not acceptance. Observable ❑Not Applicable C403.2.4. Minimum one humidity control device❑Complies Requirement will be met. 2.4 per installed ❑Does Not [F156]3 humidification/dehumidification ❑Not Observable system. Controls prevent simultaneous operation of ❑Not Applicable humidification and dehumidification equipment. C403.2.1 HVAC systems and equipment design ❑Complies Requirement will be met. [F150]3 loads calculated in accordance with ❑Does Not ANSI/ASHRAE/ACCA Standard 183 or ❑Not Observable ACCA Manual N or by an approved ❑Not Applicable equivalent computational procedure. Design loads shall be attached to the code compliance form submitted to the building department when the building is permitted or, in the event the mechanical permit is obtained at a later time, the sizing calculation shall be submitted with the application for the mechanical permit. C403.2.2 HVAC systems and equipment❑Complies Requirement will be met. [F127]3 capacity does not exceed calculated I❑Does Not loads. ❑Not Observable ❑Not Applicable C403.2.4. Heating and cooling to each zone is I❑Complies Requirement will be met. 1 controlled by a thermostat control. I❑Does Not [F147]3 Minimum one humidity control device Observable per installed❑Not humidification/dehumidification '❑Not Applicable system. j C403.2.4. Heat pump controls prevent ❑Complies Requirement will be met. 1.1 supplemental electric resistance heat ❑Does Not [F142]3 from coming on when not needed. ❑Not Observable ❑Not Applicable C403.2.4. Thermostatic controls have a 5 °F ❑Complies Requirement will be met. 1.2 deadband. ❑Does Not [FI38]3 ❑Not Observable ❑Not Applicable C403.2.4. Temperature controls have setpoint ❑Complies Requirement will be met. 1.3 overlap restrictions. ❑Does Not [F120]3 ❑Not Observable ❑Not Applicable C403.2.4. Each zone equipped with setback ❑Complies Requirement will be met. 2 controls using automatic time clock or ❑Does Not [F139]3 programmable control system. ❑Not Observable ❑Not Applicable 1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: Autozone Store #3607 Report date: 05/18/21 Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 13 of 16 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C404.12.2 Public lavatory facilities equipped with❑Complies Requirement will be met. [F153]3 outlet devices which limit the flow of ❑Does Not hot water to a maximum of 0.5 gpm or ❑Not Observable are equipped with self -closing valves Applicable that limit delivery to a per cycle❑Not maximum of 0.25 gallons of hot water for recirculating systems and to a maximum of 0.50 gallons for non - recirculating systems. C404.12.2 Public lavatory water temperature ❑Complies Requirement will be met. [F157]3 <=110°F. ❑Does Not ❑Not Observable ❑Not Applicable C404.12.1 Showers used for non -safety reasons❑Complies Requirement will be met. [F152]3 equipped with flow control devices to '❑Does Not limit the water discharge to a ❑Not Observable maximum of 2.5 gpm per shower ❑Not Applicable head. Flow restricting inserts used as a component part of a showerhead are mechanically retained at the point of manufacture C408.2.2 Construction documents require that a ❑Complies Requirement will be met. [F154]3 written balance report be provided to ❑Does Not the building owner or rep for HVAC ❑Not Observable systems serving zones with total ❑Not Applicable condition area > 5,000 sqft. Air distribution systems shall be tested, adjusted, and balanced by a licensed engineer or certified company. C403.2.4. Automatic Controls: Setback to 55°F❑Complies Requirement will be met. 2.1, (heat) and 85°F (cool); 7-day clock, 2- '❑Does Not C403.2.4. hour occupant override, 10-hour ❑ Not Observable 2.2 [F140]3 backup ❑Not Applicable i C404.3 Heat traps installed on supply and ;❑Complies !,Requirement will be met. [FI11]3 discharge piping of non -circulating ❑Does Not systems. ❑Not Observable T❑Not Applicable C404.4 All piping insulated in accordance with❑Complies Requirement will be met. [1125]2 section details and Table C403.2.10. :❑Does Not ❑Not Observable j❑Not Applicable ii C405.4.1 Interior installed lamp and fixture❑Complies See the Interior Lighting fixture schedule for values. [F118]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting demonstrating ❑Not Observable plans, proposed watts ;❑Not Applicable are less than or equal to allowed watts. C405.5.1 Exterior lighting power is consistent❑Complies ;See the Exterior Lighting fixture schedule for values. [F119]1 with what is shown on the approved ❑Does Not lighting plans, demonstrating ❑Not Observable proposed watts are less than or equal ❑Not Applicable to allowed watts. C408.2.1 Commissioning plan developed by ❑Complies Requirement will be met. [F128]1 registered design professional or ❑Does Not approved agency. ❑Not Observable Location on plans/spec: Not Required. Building under squre footage ❑Not Applicable 1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: Autozone Store #3607 Report date: 05/18/21 Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 14 of 16 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C408.2.3. HVAC equipment has been tested to ❑Complies Requirement will be met. 1 ensure proper operation. ❑Does Not [F131]1 ❑Not Observable ❑Not Applicable C408.2.3. HVAC control systems have been ❑Complies Requirement will be met. 2 tested to ensure proper operation, ❑Does Not [FI10]1 calibration and adjustment of controls. ❑Not Observable ❑Not Applicable C408.2.4 Preliminary commissioning report ❑Complies Requirement will be met. [F129]1 completed and certified by registered ❑Does Not design professional or approved agency. ❑Not Observable Location on plans/spec: Not Required. Building under squre footage ❑ Not Applicable C408.2.5. Furnished HVAC as -built drawings ❑Complies Requirement will be met. 1 submitted within 90 days of system ❑Does Not [F17]3 acceptance. ❑Not Observable ❑Not Applicable C408.2.5. Furnished as -built drawings for ❑Complies Requirement will be met. 1 electric power systems within 90 days ❑Does Not [F116]3 of system acceptance. ❑Not Observable ❑Not Applicable C408.2.5. An air and/or hydronic system ❑Complies Requirement will be met. 3 balancing report is provided for HVAC ❑Does Not [F143]1 systems. ❑Not Observable ❑Not Applicable C408.2.5. Final commissioning report due to ❑Complies Requirement will be met. 4 building owner within 90 days of ❑Does Not [F130]1 receipt of certificate of occupancy. ❑Not Observable Location on plans/spec: Not Required. Building under squre footage ❑Not Applicable C408.3 Lighting systems have been tested to ❑Complies Requirement will be met. [F133]1 ensure proper calibration, adjustment, ❑Does Not programming, and operation. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: Autozone Store #3607 Report date: 05/18/21 Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 15 of 16 Project Title: Autozone Store #3607 Report date: 05/18/21 Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 16 of 16