COMcheck Software Version 4.1.5.1
Interior Lighting Compliance Certificate
Project Information
Energy Code:
Project Title:
Project Type:
Construction Site:
Fort Pierce, FL 34951
Allowed Interior Lighting Power
2017 Florida Building Code, Energy Conservation
Autozone Store #3607
Alteration
Owner/Agent:
Autozone Design and Construction
123 S. Front Street
Memphis, TN 38103
Designer/Contractor:
Danny Doss
Advanced Consulting Engineers,
Inc.
132 Kelley Dr
Rogers, AR 72757
479-631-1712
acei@advengineers.com
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts / ft2 (B X C)
1-AutoZone (Retail:Sales Area) 7343 1.59 11675
Proposed Interior Lighting Power
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
AutoZone ( Retail:Sales Area 7343 s"
LED: A: LED: Other:
LED: B: LED: Other:
Interior Lighting Compliance Statement
Total Allowed Watts = 11675
B C D E
Lamps/ # of Fixture (C X D)
Fixture Fixtures Watt.
4 56 48 2688
2 62 24 1488
Total Proposed Watts = 4176
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting
systems have been designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version
4.1.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist.
Danny E Doss PE
,, 05-18-21
Name - Title Signature 61 Date
Project Title: Autozone Store #3607 Report date: 05/18/21
Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 1 of 16
6�(
COMcheck Software Version 4.1.5.1
Exterior Lighting Compliance Certificate
Project Information
Energy Code:
Project Title:
Project Type:
Exterior Lighting Zone
Construction Site:
Fort Pierce, FL 34951
Allowed Exterior Lighting Power
A
Area/Surface Category
2017 Florida Building Code, Energy Conservation
Autozone Store #3607
Alteration
2 (Residential mixed use area)
Owner/Agent:
Autozone Design and Construction
123 S. Front Street
Memphis, TN 38103
B
Quantity
Designer/Contractor:
Danny Doss
Advanced Consulting Engineers,
Inc.
132 Kelley Dr
Rogers, AR 72757
479-631-1712
acei@advengineers.com
C D E
Allowed Tradable Allowed Watts
Watts / Unit Wattage (B X C)
Illuminated area of facade wall or surface 435 ft2 0.1 No 44
Total Tradable Watts (a) = 0
Total Allowed Watts = 44
Total Allowed Supplemental Watts (b) = 600
(a) Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b) A supplemental allowance equal to 600 watts may be applied toward compliance of both non -tradable and tradable areas/surfaces.
Proposed Exterior Lighting Power
A B C D E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixtures Watt.
Illuminated area of facade wall or surface (435 ft2): Non -tradable Wattage
LED 1: D: LED Other Fixture Unit 40W: 1 1 40 40
Total Tradable Proposed Watts = 0
Exterior Lighting Compliance Statement
Compliance Statement: The proposed exterior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting
systems have been designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version
4.1.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist.
Danny E Doss PE VJ' I CJ'L I
Name Title Signature Date
Project Title: Autozone Store #3607 Report date: 05/18/21
Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 2 of 16
6�(
COMcheck Software Version 4.1.5.1
Mechanical Compliance Certificate
Project Information
Energy Code:
Project Title:
Location:
Climate Zone:
Project Type:
Construction Site:
Fort Pierce, FL 34951
Mechanical Systems List
Quantity System Type & Description
2017 Florida Building Code, Energy Conservation
Autozone Store #3607
Fort Pierce, Florida
2a
Alteration
Owner/Agent:
Autozone Design and Construction
123 S. Front Street
Memphis, TN 38103
HVAC System 1 (Single Zone):
Single Package Heat Pump
Heating Mode: Capacity = 67 kBtu/h,
Proposed Efficiency = 3.40 COP, Required Efficiency = 3.30 COP
Cooling Mode: Capacity = 71 kBtu/h,
Proposed Efficiency = 12.00 EER, Required Efficiency: 11.00 EER + 12.0 IEER
Fan System: None
Water Heater 1:
Electric Instantaneous Water Heater, Capacity: 4 gallons
No minimum efficiency requirement applies
Mechanical Compliance Statement
Designer/Contractor:
Danny Doss
Advanced Consulting Engineers,
Inc.
132 Kelley Dr
Rogers, AR 72757
479-631-1712
acei@advengineers.com
Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building
plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been
designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version 4.1.5.1 and to comply
with any applicable mandatory requirements listed in the Inspection Checklist.
Danny E Doss PE e V e- "1J-' V-"
Name - Title Sign ure Date
Project Title: Autozone Store #3607
Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck
Report date: 05/18/21
Page 3 of 16
eCOMcheck Software Version 4.1.5.1
l�4 Inspection Checklist
Energy Code: 2017 Florida Building Code, Energy Conservation
Requirements: 100.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
#
Plan Review
� 7
Complies?
Comments/Assumptions
& Req.ID
C103.2
Plans, specifications, and/or
❑Complies
Requirement will be met.
[PR2]1
calculations provide all information
❑Does Not
with which compliance can be
❑Not Observable
determined for the mechanical
❑Not Applicable
systems and equipment and
document where exceptions to the
standard are claimed. Load
calculations per acceptable
engineering standards and
handbooks.
C103.2
Plans, specifications, and/or
❑Complies
Requirement will be met.
[PR3]1
calculations provide all information
❑Does Not
with which compliance can be
❑Not Observable
determined for the service water
❑Not Applicable
heating systems and equipment and
document where exceptions to the
standard are claimed. Hot water
system sized per manufacturer's
sizing guide.
C405.6
Plans, specifications, and/or
❑Complies
Requirement will be met.
[PR17]1
calculations provide all information
❑Does Not
with which compliance can be
❑Not Observable
determined for the electrical systems
❑Not Applicable
and equipment and document where
exceptions are claimed. Provisions are
made for metering individual tenant
units. Feeder connectors (for feeder
and branch circuits) sized in
accordance with approved plans with
maximum drop of 5% voltage drop
total.
C103.2
Plans, specifications, and/or
❑Complies
Requirement will be met.
[PR4]1
calculations provide all information
❑Does Not
with which compliance can be
❑Not Observable
determined for the interior lighting
❑Not Applicable
and electrical systems and equipment
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
111 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3)
Project Title: Autozone Store #3607 Report date: 05/18/21
Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 4 of 16
Section
#
& Req.ID
Plan Review
Complies?
Comments/Assumptions
C103.2
Plans, specifications, and/or
❑Complies Requirement will be met.
[PR8]1
calculations provide all information
❑Does Not
with which compliance can be
❑Not Observable
determined for the exterior lighting
❑Not Applicable
and electrical systems and equipment
and document where exceptions to
the standard are claimed. Information
provided should include exterior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
Additional Comments/Assumptions:
111 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3)
Project Title: Autozone Store #3607
Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck
Report date: 05/18/21
Page 5 of 16
Section
# Footing / Foundation Inspection Complies? Comments/Assumptions
& Recl.ID
C403.2.4. Snow/ice melting system sensors for ❑Complies Exception: Requirement does not apply.
5, future connection to controls. Freeze ❑Does Not
C403.2.4. protection systems have automatic
6 controls installed. ❑Not Observable
[FO9]3 ❑Not Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3)
Project Title: Autozone Store #3607
Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck
Report date: 05/18/21
Page 6 of 16
Section
#
Plumbing Rough -In Inspection
Complies?
Comments/Assumptions
& Req.ID
C404.5,
Heated water supply piping conforms❑Complies
Exception: Requirement does not apply.
C404.5.1,
to pipe length and volume
❑Does Not
C404.5.2
requirements. Refer to section details.
❑Not Observable,
[PL6]3
❑Not Applicable
C404.5,
Heated water supply piping conforms
;❑Complies ;Requirement will be met.
C404.5.1,
to pipe length and volume
:❑Does Not
C404.5.2
requirements. Refer to section details.❑Not
Observable',
[PL6]3
j❑Not Applicable
C404.6.3
Pumps that circulate water between a
❑Complies Exception: Requirement does not apply.
[PL7]3
heater and storage tank have controls
❑Does Not
that limit operation from startup to
❑Not Observable
<= 5 minutes after end of heating
❑Not Applicable
cycle.
C404.6.3
Pumps that circulate water between a
❑Complies Exception: Requirement does not apply.
[PL7]3
heater and storage tank have controls
❑Does Not
that limit operation from startup to
❑Not Observable',
<= 5 minutes after end of heating
I❑Not Applicable
cycle.
C404.7
Water distribution system that pumps
❑Complies Exception: Requirement does not apply.
[PL8]3
water from a heated -water supply
❑Does Not
pipe back to the heated -water source
❑Not Observable
through a cold -water supply pipe is a
❑Not Applicable
demand recirculation water system.
Pumps within this system have
controls that start the pump upon
receiving a signal from the action of a
user of a fixture or appliance and
limits the temperature of the water
entering the cold -water piping to
104°F.
C404.7
Water distribution system that pumps
;❑Complies
Exception: Requirement does not apply.
[PL8]3
water from a heated -water supply
:❑Does Not
pipe back to the heated -water source
:
Observable
;
I
through a cold -water supply pipe is a❑Not
Applicable
demand recirculation water system.
;❑Not
Pumps within this system have
controls that start the pump upon
receiving a signal from the action of a
user of a fixture or appliance and
limits the temperature of the water
entering the cold -water piping to
104°F.
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3)
Project Title: Autozone Store #3607 Report date: 05/18/21
Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 7 of 16
Section
#
Mechanical Rough -In Inspection
Complies?
Comments/Assumptions
& Req.ID
C402.2.6
Thermally ineffective panel surfaces of
❑Complies
Exception: Requirement does not apply.
[ME41]3
sensible heating panels have
❑Does Not
insulation >= R-3.5.
❑Not Observable
❑Not Applicable
C403.2.12
HVAC fan systems at design
❑Complies
Requirement will be met.
.1
conditions do not exceed allowable
❑Does Not
[ME65]3
fan system motor nameplate hp or fan
❑Not Observable
See the Mechanical Systems list for values.
system bhp.
❑Not Applicable
C403.2.12
Fans have efficiency grade (FEG) >_
❑Complies
Requirement will be met.
.3
67. The total efficiency of the fan at
❑Does Not
[ME117]2
the design point of operation <= 15%
❑Not Observable
of maximum total efficiency of the
❑Not Applicable
fan.
C403.2.9.
HVAC ducts and plenums insulated
❑Complies
Requirement will be met.
1.1
and sealed according to Florida
❑Does Not
[ME60]2
Section C403.2.9, Table C403.2.9.1.
❑Not Observable
❑Not Applicable
C403.2.9.
All ducts, air handlers, filter boxes,
❑Complies
Requirement will be met.
2
building cavities, mechanical closets
❑Does Not
[ME79]2
and enclosed support platforms that
❑Not Observable
form the primary air containment
❑Not Applicable
passageways for air distribution
systems are constructed and erected
in accordance with Table C403.2.9.2
and with Chapter 6 of the Florida
Building Code, Mechanical. Ducts are
be constructed, braced, reinforced
and installed to provide structural
strength and durability. All transverse
joints, longitudinal seams and fitting
connections are securely fastened in
accordance with the applicable
standards of this section.
C403.2.9.
Duct insulation is protected from
❑Complies
Requirement will be met.
1.2
damage but not limited to the
❑Does Not
[ME80]2
following: 1. Insulation exposed to
❑Not Observable
weather is suitable for outdoor
❑Not Applicable
service. Cellular foam insulation is
protected or painted with a coating
that is water retardant and provides
shielding from solar radiation. 2.
Insulation covering cooling ducts
located outside the conditioned space
is vapor retardant located outside the
insulation, all penetrations and joints
of which shall be sealed.
C403.2.9.
Additional insulation with vapor
❑Complies
Requirement will be met.
1.3
barrier is provided where the
❑Does Not
[ME81]2
minimum duct insulation requirements
❑Not Observable
of Section C403.2.9.1.1 are
❑Not Applicable
determined to be insufficient to
prevent condensation.
C403.2.13
Unenclosed spaces that are heated
❑Complies
Exception: Requirement does not apply.
[ME71]2
use only radiant heat.
❑Does Not
❑Not Observable
❑Not Applicable
C403.2.3
HVAC equipment efficiency verified.
❑Complies
See the Mechanical Systems list for values.
[ME55]2
❑Does Not
❑Not Observable
❑Not Applicable
111 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Autozone Store #3607 Report date: 05/18/21
Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 8 of 16
Section
#
Mechanical Rough -In Inspection
Complies?
Comments/Assumptions
& Reci.ID
C403.2.9.
Ducts, air handlers, filter boxes,
;❑Complies Requirement will be met.
3
building cavities, mechanical closets
❑Does Not
[ME10]z
and enclosed support platforms that
❑Not Observable ,
form the primary air containment
Applicable
passageways for air distribution❑Not
systems are sealed in accordance with
the applicable criteria of this section
and Table C403.2.9.2.
C403.2.9.
Cavities in framed spaces are not
;❑Complies Requirement will be met.
4
used to deliver air from or return air to
:❑Does Not
[ME78]2
the conditioning system unless they
❑Not Observable',
contain an air duct insert which is
Applicable
insulated in accordance with Section❑Not
j
C403.2.9.1 and constructed and
sealed in accordance with the
requirements of Section C403.2.9.2
appropriate for the duct materials
used.
C403.2.9.
Air distribution systems are sized and❑Complies
Requirement will be met.
5
designed in accordance with
:❑Does Not
[ME76]2
recognized engineering standards.
❑Not Observable'
Refer to section details.
T❑Not Applicable
C403.2.9.
Air -handling units not installed in❑Complies
Requirement will be met.
6
attics of commercial buildings.
❑Does Not
[ME77]2
❑Not Observable;
T❑Not Applicable
C408.2.2
Air system balancing accomplished in❑Complies
Requirement will be met.
1
a manner to first minimize throttling
:❑Does Not
[ME53]3
losses, then for fans with fan system
❑Not Observable
power greater than 1 hp, fan speeds
Applicable
shall be adjusted to meet design flow❑Not
conditions. Balancing procedures shall
be in accordance with NEBB
Procedural Standards, the AABC,
National Standards, or equivalent
procedures.
C403.2.6.
Demand control ventilation provided
❑Complies Exception: Requirement does not apply.
1
for spaces >500 ft2 and >25
❑Does Not
[ME59]1
people/1000 ft2 occupant density and
❑Not Observable
served by systems with air side
❑Not Applicable
economizer, auto modulating outside
air damper control, or design airflow
>3,000 cfm.
C403.2.6.
Enclosed parking garage ventilation❑Complies
Exception: Requirement does not apply.
2
has automatic contaminant detection
:❑Does Not
[ME115]3
and capacity to stage or modulate
fans to 50% or less of design capacity.❑Not
j Observable'
❑Not Applicable
C403.2.7
Exhaust air energy recovery on❑Complies
Exception: Requirement does not apply.
[ME57]1
systems meeting Table C403.2.7(1)
:❑Does Not
and C403.2.7(2).
❑Not Observable
❑Not Applicable
C403.2.8
Kitchen exhaust systems comply with❑Complies
Exception: Requirement does not apply.
[ME11613
replacement air and conditioned
:❑Does Not
supply air limitations, and satisfy hood
❑Not Observable
rating requirements and maximum
Applicable
exhaust rate criteria.❑Not
C403.4.4.
Multiple zone VAV systems with DDC❑Complies
i
, Exception: Requirement does not apply.
6
of individual zone boxes have static
❑Does Not
[ME110]3
pressure setpoint reset controls.
See the Mechanical Systems list for values.
❑Not Observable;
T❑Not Applicable
1 I High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3)
Project Title: Autozone Store #3607 Report date: 05/18/21
Data filename: X:\COMCheck Files\Advanced Energy Sol utions\AZRM6447.cck Page 9 of 16
Section
# Mechanical Rough -In Inspection Complies?
Comments/Assumptions
& Req.ID
C408.2.2.
Air outlets and zone terminal devices❑Complies
Requirement will be met.
1
have means for air balancing.
:❑Does Not
[ME53]3
❑Not Observable
❑Not Applicable
C403.5,
Refrigerated display cases, walk-in❑Complies
Exception: Requirement does not apply.
C403.5.1,
coolers or walk-in freezers served by
:❑Does Not
C403.5.2
remote compressors and remote
❑Not Observable
[ME123]3
condensers not located in a
Applicable
condensing unit, have fan -powered
;❑Not
condensers that comply with Sections
C403.5.1 and refrigeration compressor;
systems that comply with C403.5.2..
j
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3)
Project Title: Autozone Store #3607 Report date: 05/18/21
Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 10 of 16
Section
#
Rough -In Electrical Inspection
Complies?
Comments/Assumptions
& Req.ID
C405.2.1
Lighting controls installed to uniformly❑Complies
Requirement will be met.
[EL15]1
reduce the lighting load by at least
:❑Does Not
50%.❑Not
Observable
❑Not Applicable
C405.2.1
Occupancy sensors installed in
;❑Complies
Requirement will be met.
[EL18]1
required spaces.
:❑Does Not
❑Not Observable
❑Not Applicable
C405.2.1,
Independent lighting controls installed
❑Complies
Requirement will be met.
C405.2.2.
per approved lighting plans and all
❑Does Not
3
manual controls readily accessible and
❑Not Observable
[EL23] 2
visible to occupants.
❑Not Applicable
C405.2.2.
Automatic controls to shut off all❑Complies
Requirement will be met.
1
building lighting installed in all
:❑Does Not
[EL22]2
buildings.
❑Not Observable
T❑Not Applicable
C405.2.3
Daylight zones provided with❑Complies
!Exception: Requirement does not apply.
[EL16]2
individual controls that control the
:❑Does Not
lights independent of general area
�Not Observable;
❑
lighting.
❑Not Applicable
C405.2.3,
Primary sidelighted areas are
;❑Complies
!Exception: Requirement does not apply.
C405.2.3.
equipped with required lighting
:❑Does Not
1,
C405.2.3.
controls.
❑Not Observable;
2
;❑Not Applicable
[EL20]1
C405.2.3,
Enclosed spaces with daylight area❑Complies
Exception: Requirement does not apply.
C405.2.3.
under skylights and rooftop monitors
:❑Does Not
1,
are equipped with required lighting
❑Not Observable
C405.2.3.
controls.
❑Not Applicable
3
[EL21]1
C405.2.4
Separate lighting control devices for
❑Complies
Requirement will be met.
[EL4]1
specific uses installed per approved
❑Does Not
lighting plans.
❑Not Observable
❑Not Applicable
C405.2.4
Additional interior lighting power
❑Complies
Requirement will be met.
[EL8]1
allowed for special functions per the
❑Does Not
approved lighting plans and is
❑Not Observable
automatically controlled and
❑Not Applicable
separated from general lighting.
C405.2.5
Automatic lighting controls for exterior;❑Complies
Requirement will be met.
[EL25]nu°
lighting installed. Controls will be
:❑Does Not
daylight controlled, set based on
❑Not Observable!
business operation time -of -day, or
Applicable
reduce connected lighting > 30%
;❑Not
C405.3
Exit signs do not exceed 5 watts per❑Complies
Requirement will be met.
[EL6]1
face.
:❑Does Not
❑Not Observable!
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Autozone Store #3607 Report date: 05/18/21
Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 11 of 16
111 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3)
Project Title: Autozone Store #3607 Report date: 05/18/21
Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 12 of 16
Section
#
Final Inspection
Complies?
Comments/Assumptions
& Req.ID
C303.3,
Furnished O&M instructions for❑Complies
Requirement will be met.
C408.2.5.
systems and equipment to the
:❑Does Not
2
[F117]3
building owner or designated
representative.
❑Not Observable;
❑Not Applicable
C303.3,
Furnished O&M manuals for HVAC
;❑Complies
;Requirement will be met.
C408.2.5.
systems within 90 days of system
❑Does Not
3
[F18]3❑Not
acceptance.
Observable
❑Not Applicable
C403.2.4.
Minimum one humidity control device❑Complies
Requirement will be met.
2.4
per installed
❑Does Not
[F156]3
humidification/dehumidification
❑Not Observable
system. Controls prevent
simultaneous operation of
❑Not Applicable
humidification and dehumidification
equipment.
C403.2.1
HVAC systems and equipment design
❑Complies
Requirement will be met.
[F150]3
loads calculated in accordance with
❑Does Not
ANSI/ASHRAE/ACCA Standard 183 or
❑Not Observable
ACCA Manual N or by an approved
❑Not Applicable
equivalent computational procedure.
Design loads shall be attached to the
code compliance form submitted to
the building department when the
building is permitted or, in the event
the mechanical permit is obtained at a
later time, the sizing calculation shall
be submitted with the application for
the mechanical permit.
C403.2.2
HVAC systems and equipment❑Complies
Requirement will be met.
[F127]3
capacity does not exceed calculated
I❑Does Not
loads.
❑Not Observable
❑Not Applicable
C403.2.4.
Heating and cooling to each zone is
I❑Complies
Requirement will be met.
1
controlled by a thermostat control.
I❑Does Not
[F147]3
Minimum one humidity control device
Observable
per installed❑Not
humidification/dehumidification
'❑Not Applicable
system.
j
C403.2.4.
Heat pump controls prevent
❑Complies
Requirement will be met.
1.1
supplemental electric resistance heat
❑Does Not
[F142]3
from coming on when not needed.
❑Not Observable
❑Not Applicable
C403.2.4.
Thermostatic controls have a 5 °F
❑Complies
Requirement will be met.
1.2
deadband.
❑Does Not
[FI38]3
❑Not Observable
❑Not Applicable
C403.2.4.
Temperature controls have setpoint
❑Complies
Requirement will be met.
1.3
overlap restrictions.
❑Does Not
[F120]3
❑Not Observable
❑Not Applicable
C403.2.4.
Each zone equipped with setback
❑Complies
Requirement will be met.
2
controls using automatic time clock or
❑Does Not
[F139]3
programmable control system.
❑Not Observable
❑Not Applicable
1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3)
Project Title: Autozone Store #3607 Report date: 05/18/21
Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 13 of 16
Section
#
Final Inspection
Complies?
Comments/Assumptions
& Req.ID
C404.12.2
Public lavatory facilities equipped with❑Complies
Requirement will be met.
[F153]3
outlet devices which limit the flow of
❑Does Not
hot water to a maximum of 0.5 gpm or
❑Not Observable
are equipped with self -closing valves
Applicable
that limit delivery to a per cycle❑Not
maximum of 0.25 gallons of hot water
for recirculating systems and to a
maximum of 0.50 gallons for non -
recirculating systems.
C404.12.2
Public lavatory water temperature
❑Complies
Requirement will be met.
[F157]3
<=110°F.
❑Does Not
❑Not Observable
❑Not Applicable
C404.12.1
Showers used for non -safety reasons❑Complies
Requirement will be met.
[F152]3
equipped with flow control devices to
'❑Does Not
limit the water discharge to a
❑Not Observable
maximum of 2.5 gpm per shower
❑Not Applicable
head. Flow restricting inserts used as
a component part of a showerhead
are mechanically retained at the point
of manufacture
C408.2.2
Construction documents require that a
❑Complies
Requirement will be met.
[F154]3
written balance report be provided to
❑Does Not
the building owner or rep for HVAC
❑Not Observable
systems serving zones with total
❑Not Applicable
condition area > 5,000 sqft. Air
distribution systems shall be tested,
adjusted, and balanced by a licensed
engineer or certified company.
C403.2.4.
Automatic Controls: Setback to 55°F❑Complies
Requirement will be met.
2.1,
(heat) and 85°F (cool); 7-day clock, 2-
'❑Does Not
C403.2.4.
hour occupant override, 10-hour
❑ Not Observable
2.2
[F140]3
backup
❑Not Applicable
i
C404.3
Heat traps installed on supply and
;❑Complies
!,Requirement will be met.
[FI11]3
discharge piping of non -circulating
❑Does Not
systems.
❑Not Observable
T❑Not Applicable
C404.4
All piping insulated in accordance with❑Complies
Requirement will be met.
[1125]2
section details and Table C403.2.10.
:❑Does Not
❑Not Observable
j❑Not Applicable
ii
C405.4.1
Interior installed lamp and fixture❑Complies
See the Interior Lighting fixture schedule for values.
[F118]1
lighting power is consistent with what
❑Does Not
is shown on the approved lighting
demonstrating
❑Not Observable
plans, proposed watts
;❑Not Applicable
are less than or equal to allowed
watts.
C405.5.1
Exterior lighting power is consistent❑Complies
;See the Exterior Lighting fixture schedule for values.
[F119]1
with what is shown on the approved
❑Does Not
lighting plans, demonstrating
❑Not Observable
proposed watts are less than or equal
❑Not Applicable
to allowed watts.
C408.2.1
Commissioning plan developed by
❑Complies
Requirement will be met.
[F128]1
registered design professional or
❑Does Not
approved agency.
❑Not Observable
Location on plans/spec: Not Required. Building under squre
footage
❑Not Applicable
1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3)
Project Title: Autozone Store #3607 Report date: 05/18/21
Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 14 of 16
Section
#
Final Inspection
Complies?
Comments/Assumptions
& Req.ID
C408.2.3.
HVAC equipment has been tested to
❑Complies
Requirement will be met.
1
ensure proper operation.
❑Does Not
[F131]1
❑Not Observable
❑Not Applicable
C408.2.3.
HVAC control systems have been
❑Complies
Requirement will be met.
2
tested to ensure proper operation,
❑Does Not
[FI10]1
calibration and adjustment of controls.
❑Not Observable
❑Not Applicable
C408.2.4
Preliminary commissioning report
❑Complies
Requirement will be met.
[F129]1
completed and certified by registered
❑Does Not
design professional or approved
agency.
❑Not Observable
Location on plans/spec: Not Required. Building under squre
footage
❑ Not Applicable
C408.2.5.
Furnished HVAC as -built drawings
❑Complies
Requirement will be met.
1
submitted within 90 days of system
❑Does Not
[F17]3
acceptance.
❑Not Observable
❑Not Applicable
C408.2.5.
Furnished as -built drawings for
❑Complies
Requirement will be met.
1
electric power systems within 90 days
❑Does Not
[F116]3
of system acceptance.
❑Not Observable
❑Not Applicable
C408.2.5.
An air and/or hydronic system
❑Complies
Requirement will be met.
3
balancing report is provided for HVAC
❑Does Not
[F143]1
systems.
❑Not Observable
❑Not Applicable
C408.2.5.
Final commissioning report due to
❑Complies
Requirement will be met.
4
building owner within 90 days of
❑Does Not
[F130]1
receipt of certificate of occupancy.
❑Not Observable
Location on plans/spec: Not Required. Building under squre
footage
❑Not Applicable
C408.3
Lighting systems have been tested to
❑Complies
Requirement will be met.
[F133]1
ensure proper calibration, adjustment,
❑Does Not
programming, and operation.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3)
Project Title: Autozone Store #3607 Report date: 05/18/21
Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 15 of 16
Project Title: Autozone Store #3607 Report date: 05/18/21
Data filename: X:\COMCheck Files\Advanced Energy Solutions\AZRM6447.cck Page 16 of 16