Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FL3607-D1_05-28-21
LANDSCAPE AREA ADA RAMP DEMOLITION PLAN 1/8" = 1 ' —0" r,a'-rH LANDSCAPE AREA ACCORDING TO LANDLORD -PROVIDED INSPECTION AND TEST REPORT BY HOME INSPECTIONS PLUS, REPORT NO. 202102082, DATED 2/18/2021, NO ASBESTOS CONTAINED MATERIALS OR LEAD BASED MATERIALS HAVE BEEN DETECTED, CONSTRUCTION CHANGES OR ALTERATIONS BY FAILURE TO VERIFY ALL EXISTING DIMENSIONS AS SHOWN ON PLAN SHALL BE AT THE COMPLETE EXPENSE OF THE GENERAL CONTRACTOR. 1. THE GENERAL CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS REQUIRED TO COMPLETE DEMOLITION, PROPER DISPOSITION OR REUSE OF ALL ITEMS SHOWN ON DRAWING. 2. THE GENERAL CONTRACTOR SHALL PROTECT AT ALL TIMES THE PROPERTY OF THE OWNER AND OTHER TENANTS IN THE BUILDING. THIS INCLUDES BUT IS NOT LIMITED TO WINDOWS, FLOORS, CEILING, TOILETS, DOORS, TRIM, AND ELECTRICAL EQUIPMENT OR OPENINGS CREATED BY THE REMOVAL OF ANY ITEM. 3. THE GENERAL CONTRACTOR SHALL DIRECT ALL NECESSARY SHORING, BRACING, TEMPORARY PARTITIONS, AND COVERING OF OPENINGS TO PROTECT THE EXISTING BUILDING WHILE DEMOLITION AND CONSTRUCTION IS IN PROGRESS. 4. ALL WORK DEMOLISHED SHALL BE REMOVED FROM THE PREMISES DAILY, EXCEPT ITEMS TO BE RE -USED OR RETURNED TO THE OWNER OR AS DIRECTED OTHERWISE. 5, PATCH AND REPAIR EXISTING CONSTRUCTION IMPACTED BY DEMOLITION TO RESTORE FINISH TO "LIKE NEW" CONDITION UNLESS DIRECTED OTHERWISE. 6. DOOR HARDWARE, LIGHT FIXTURES, ETC. REMOVED AND NOT IMMEDIATELY RE -USED ARE TO BE STORED IN AN AREA DESIGNATED BY THE PROJECT MANAGER. 7. TAKE PRECAUTION AGAINST ELECTRICAL AND FIRE HAZARDS DURING DEMOLITION. DO NOT INTERRUPT POWER IN OCCUPIED TENANT SPACES WITHOUT PRIOR NOTICE AND APPROVAL OF LANDLORD/OWNER, 8. CONCRETE TO BE REMOVED SHALL BE SAWCUT PRIOR TO REMOVAL IN ORDER TO PROTECT SLAB TO REMAIN. 9. THE GENERAL CONTRACTOR SHALL REMOVE ALL UNUSED SWITCH PLATES, WIRING OR EQUIPMENT. ALL WIRES AND CONDUIT NOT COMPLETELY REMOVED TO THE SOURCE MUST TERMINATE IN A JUNCTION BOX WITH COVER AND APPROPRIATE INSULATORS SUFFICIENT TO MAINTAIN COMPLIANCE WITH APPLICABLE CODES. 10, ALL ITEMS GRAPHICALLY DEPICTED AS BEING DEMOLISHED SHALL BE REMOVED. THE KEY NOTES ARE A REFERENCE TO AID THE CONTRACTOR AND SHALL NOT BE INTERPRETED AS PRECISE INDICATIONS OF THE SCOPE OF DEMOLITION WORK DEPICTED IN THE DOCUMENTS. 11.THE REMOVAL AND LEGAL DISPOSAL OF ANY ASBESTOS SHALL BE THE RESPONSIBILITY OF THE LANDLORD. THE GENERAL CONTRACTOR SHALL RECEIVE THE BUILDING AFTER ASBESTOS ABATEMENT HAS CONCLUDED. 12. SHOULD CONFUSION EXIST RELATIVE TO THE REMOVAL OF SPECIFIC ITEMS OR THE RE -USE OF SAME, CONTACT THE AUTOZONE FIELD PROJECT MANAGER FOR INSTRUCTIONS. 1/8" = 1'-0" gen—demo—notes GENERAL DEMOLITION NOTES OA REMOVE INDICATED SECTIONS OF EXISTING STOREFRONT TO ALLOW FOR THE INSTALLATION OF NEW DOORS AND STOREFRONT. E�INSTALLATION REMOVE EXISTING DOORS. PATCH AND PREPARE OPENING FOR OF NEW STOREFRONT GLAZING TO MATCH EXISTING. ©REMOVE EXISTING DELIVERY DOOR AND FRAME, RAISE HEAD TO 8'-0". SEE NOTES ON SHT. A-1, OD EXISTING ELECTRIC METER TO REMAIN. EO EXISTING LOADING AREA - REMOVE EXISTING PAVING, INSTALL NEW PAVEMENT WITH 4' WIDE LANDING, SLOPE MAX 5% TO EXISTING ASPHALT PAVEMENT. NOT ALL KEYNOTES WILL BE APPLICABLE 1/8" = 1'-0" ext—demo—key EXTERIOR DEMOLITION KEYNOTES DREMOVE ALL EXIST. PHONE LINES, EXPOSED CONDUIT, ALARM WIRES AND DETECTORS, ELECTRIC PANELS, SPEAKERS, WIRING, ETC. NOT NOTED FOR REUSE. (DREMOVE ALL EXIST, WALLS, DOORS, FALSE FLOORS AND STEPS NOT HOTED FOR REUSE. REMOVE ALL CARPET, TILE, MASTIC ETC. THROUGHOUT LEASE SPACE. I6REMOVE REMOVE EXIST. CEILING GRID AND TILE, REMOVE EXIST. LIGHT FIXTURES AND LAMPS. ALL EXIST. DUCT BRANCH LINES AND DIFFUSERS. MAIN DUCTS TO REMAIN, @REMOVE REMOVE EXIST. AIR CONDITIONING EQUIPMENT. EXIST. ELECTRIC PANELS, OREMOVE EXIST. SLATWALL, PANELING AND ALL FOREIGN MATERIALS FROM EXISTING WALLS. 91LIPRIGHT,EXIST. SPRINKLER SYSTEM TO REMAIN, RESET SPRINKLER HEADS TTO RAISE SPRINKLER LINES TO MINIMUM 13' AFF, 11 PATCH, REPAIR OR REMOVE ANY DAMAGED GYPSUM BOARD ON WALLS. 12 REMOVE ALL GYPSUM BOARD ON COLUMNS. PHI 13 REMOVE ALL EXIST. RESTROOM WALLS, PLUMBING FIXTURES, WATER PEC HEATER, ETC. CAP ALL EXIST. SEWER AND WATER LINES, NOT NOTED T6 REUSE, 77F NOT ALL KEYNOTES WILL BE APPLICABLE 1/8'$ = 1'-0" E00 int—demo—key INTERIOR DEMOLITION KEYNOTES Ln C/-) z O �— N V J W 0 Lf� v J �W M I- O z J \ LL z O Q co J C'7 O > z z O L_ � W -0 z W EL N z 75 o rn O W Q 0 � U ct w') � O � U � 00 O t M t2 O A oMo 5 • ~ U A� 00 tb t U o IP C Digitally signed RD:A01 by PHILLIP C PECORD:AO1410 QOOOI D000001771FD98 8D60 D60E00017BC7 Date: 2021.05.26 7BC7 09:26:19-05'00' 05/28/2021 57N-REMODEL