HomeMy WebLinkAboutFL3607-E1-POWER-PLAN-Model(1)0 0 N 1 E2. a_ 0 WATER METER t/ INSTALL (4) SIMPLEX OUTLETS FOR BATTERY CHARGERS - TWO @ +36" AND TWO @ +54" ABOVE FINISH FLOOR, EACH ON INDIVIDUAL CIRCUITS. INSTALL ONE SIMPLEX OUTLET @ +75" FwA Cl N 0 0 C6 M -to hm o� JO'In � �m m o amo m Z U Z U U o Um O LI ~ `D GFCI ~C6 CD "' B-29 LO N a o � B-30 B-30 N THREE QO RTU FOUR OF RTU 3 RTU 4 OFFOUR m� UR L- —1 L_ —I MAKE HVAC CONNECTIONS THRU HUB PROVIDED 4 IN BOTTOM OF THE RTU. DO NOT CUT PAN TO 4 E 1 GAIN ACCESS. ALL CONNECTIONS INSIDE OF RTU E 1 N TO BE WEATHERPROOF. i I �l B-26 Mt E. D.F. GFCl PANEL "B" °+24" B-26 PANEL "A" ACTUAL LOCATION PANEL L T I �II RTU-1 LOCATE THERMOSTATS-4MOVED FOR CLARITY PANEL WALL 58'-5" ELECTRICAL FLOOR PLAN 1/8" = 1 '-0" .: : CV CD oL w t J o I m0 6 LZ Z o co k6i RTU 11 L_ _J J-BOX AT 48" AFF FOR THE VENSTAR PUSH BUTTON, AND J-BOX AT 54" AFF FOR ALARM KEY PAD. BOXES TO BE LOCATED ABOVE ONE ANOTHER AND BIN T€ DO N--P CLOSEST TO THE OFFICE AREA. IC DESIGN PARAMETERS:2017 FLORIDA BUILDING CODE 6th ADDITION ELECTRICAL METERS N LO 1. ALL WIRING SHALL COMPLY WITH LOCAL AND NATIONAL CODES: THE MOST STRINGENT SHALL GOVERN. 2. THE ELECTRICAL CONTRACTOR SHALL PROVIDE THE FOLLOWING: A. FIELD VERIFIED TYPEWRITTEN PANEL SCHEDULES B. COMPLETE "AS BUILT" RED LINE DRAWINGS TO INCLUDE RISER DIAGRAM AND PANEL SCHEDULES, C. LABEL ALL ABANDONED BREAKERS AND SEAL BLANKS AS REQUIRED. 3. ALL EXPOSED CONDUIT SHALL BE THE INTERMEDIATE METAL TYPE. 4. ALL INTERIOR WIRING SHALL BE SOFT -DRAWN COPPER. NO ALUMINUM WIRING PERMITTED. 5. ELECTRICAL CONTRACTOR SHALL VERIFY THAT THE ELECTRIC METER AND BASE ARE IN CLEAN SERVICEABLE CONDITION AND THAT ALL PRIMARY CONNECTIONS ARE TIGHT AND SECURE. 6. ALL CIRCUITS SHALL BE GROUNDED AS PER THE NATIONAL ELECTRIC CODE. 7. IF AN ALARM SYSTEM IS REQUIRED SEE SHEET E-7 FOR ELECTRICAL REQUIREMENTS. 8. ALL PRIMARY VOLTAGE WIRE SHALL BE IN CONDUIT END TO END OF CIRCUIT RUN. SIZE CONDUIT AND PROVIDE AND JUNCTION BOXES TO MEET THE CURRENT EDITION OF THE NATIONAL ELECTRIC CODE. 9. FOR STORES WITH CEILINGS EXTEND ALL CONDUITS FOR LOW VOLTAGE WIRE, TELEPHONE AND DATA CABLES 8" ABOVE THE PLANE OF THE CEILING WITH A HORIZONTAL TURN OUT. 10. FOR STORES WITHOUT CEILINGS CONDUITS FOR LOW VOLTAGE WIRE, TELEPHONE AND DATA CABLES SHALL BE CONTINUOUS END TO END OF WIRE RUN. 11. REFER TO OTHER SHEETS FOR POWER POLE NOTES AND LOCATIONS, MAN AND SERVICE DOOR REQUIREMENTS AND TO SHEET M-1 FOR LOCATION OF RTU CONVENIENCE OUTLET. 12. PROVIDE PULL STRINGS IN ALL EMPTY CONDUITS. 13. ELECTRICAL CONTRACTOR TO PROVIDE EMPTY CONDUIT & BOXES BETWEEN RTU'S AND THERMOSTAT LOCATIONS INDICATED. MECHANICAL CONTRACTOR TO PROVIDE CONTROL WIRING AND COMPLETE INSTALLATION. 14. MOUNT JUNCTION BOX TIGHT TO FLOOR FOR DISPLAY BASE FLEX OUTLET. OUTLET ON FLEX TO BE INSTALLED HORIZONTALLY IN FIXTURE BASE AFTER FIXTURES ARE SET IN PLACE. 15. NO RECEPTACLE BRANCH CIRCUIT SHALL BE INSTALLED IN A MULTIWIRE BRANCH CIRCUIT CONFIGURATION. NEUTRAL CONDUCTORS SHALL NOT BE SHARED BETWEEN DIFFERENT CIRCUITS. 16. ALL NEW CONDUIT SHALL BE INSTALLED SO THAT THE CONDUIT IS 1 1/2" FROM THE SURFACE OF THE ROOF DECK IN COMPLIANCE WITH THE REQUIREMENTS OF THE NEC. = 1'-0" 1 ELECTRICAL NOTES SYM DESCRIPTION EXHAUST FAN RECESSED FURN. REMARKS INSTALLED BY HVAC CONTRACTOR, WIRED BY ELECTRICAL AUTOZONE CONTRACTOR. elec—notes SEE SHT. E2 FOR ADDITIONAL JUNCTION BOX LOCATIONS AND 0 JUNCTION BOX G.C. REQUIREMENTS AT DOORS FOR ALARMS. 12'-10 1/4" 3'-6" LC-1 O THERMOSTAT AUTOZONE WALL MOUNT ABOVE ELECTRICAL PANELS. 9'-0" A.F.F. MAX. ---10 _ 4'-1 1/4" B-20,24 M HVAC DISCONNECT REFER TO HVAC SPECIFICATIONS WITH UNIT B-30 cll TWO UR_+� LE POWER POLES AUTOZONE REFER TO PLAN FOR LOCATION LC-7 FO �1-0 / 0 SIMPLEX RECPT. REFER TO PLAN FOR LOCATIONS G.C. 4 DUPLEX RECPT./ � -E 1 FLOOR RECPT. G.C. REFER TO PLAN FOR LOCATIONS In ceiling N LC-1 16'from door ` QUADPLEX RECPT. REFER TO PLAN FOR LOCATIONS ld LC-5 CD LC-4,6,10,12 o CCTV G.C. N B-32 B-30 RVVF WEATHERPROOF DUPLEX REFER TO PLAN FOR LOCATIONS GFCI LC-5,8OONNE B-13 RECPT.(GFI) G.C. FOUR OX-BLUE JUNCTION BOX WITH 6'-0" G.C. (FIXTURE O CAMERA FLEX CONDUIT AT WALL & KICK PLATE J-BOX AT FLOOR LEVEL, FLEX CONDUIT SET UNDER DISPLAY FIXTURES. \�» H.P. COUNTERS BY OWNER) RECEPTACLE MOUNTED TO BASE PLATE. SEE DETAIL THIS SHEET E/A_S8 1/8" = 1'-0 EPL01 A-6 - �gOVEC ENTRY DOORS 2 POWER SCHEDULE 3 CONTRACTOR TO SU PLY 120 LOW E2. LTAGE TO PEDESTAL AT ENTRANCE EMT CONDUIT ❑ SEE SIGN AGE NOTDOORS, REFER TO S CURITY DETAIL MTL. STUD WALL W GYP. BD. J0 THIS SHEET / -SHf ETf2- JUNCTION BOX DUPLEX RECEPTACLE SET HORIZONTAL IN OWNER FURNISHED BASE. FINAL LOCATION TO BE DETERMINED AFTER FIXTURES ARE SET. Danny Doss Digitally signed by Danny Doss Date: 2021.07.21 10:39:55 -05'00' 1. ALL WALL SIGNS WILL BE CONNECTED TO HOME RUN CIRCUITRY INSIDE THE BUILDING. THE DETAIL SIGN DRAWINGS WILL INDICATE WHERE THE EXTERIOR WALL PENETRATIONS WILL OCCUR. CONNECT TO J-BOXES LOCATED ON THIS SHEET. 2. IF THE SIGN IS MADE UP OF CHANNEL LETTERS, THEN INSTALL A SECOND J-BOX IN THE LOCATION PRESCRIBED BY THE DETAIL SIGN DRAWINGS. 3. GENERAL CONTRACTOR IS TO COORDINATE THE INSTALLATION BY THE SIGN VENDOR'S INSTALLER OF ALL SIGNS PER THE DETAIL SIGN DRAWING REQUIREMENTS AND MAKE ALL FINAL ELECTRICAL CONNECTIONS. 4. IF SIGNS ARE REQUIRED ON THE SIDE OR REAR WALLS OF THE BUILDING ALL NOTES ABOVE ARE APPLICABLE. SIGN WIRING WILL BE EXTENDED THROUGH WALL TO CONNECT TO SIGN. 5. WHERE NIPPLE PASSES THROUGH THE EXTERIOR WALL INSURE THE PENETRATION IS WATERTIGHT. ALARM/ BOARD DETAIL E-5 -26 I UST FAN WITH XTURE KICK PLATE BY OWNER. WISHED FLOOR u' FLEX. CONDUIT 1" = 1'-o,, NOTE: REFER TO POWER PLAN FOR LOCATIONS EPS01 4 1 RECEPTACLE DETAIL / SUPPLY FIXTURES ELECTRIC MINI -TANK WATER HEATER (PROVIDED BY AUTOZONE, INC.) ARISTON MODEL GL 4 Ti. FINAL HOOK-UP BY ELECTRICAL CONTRACTOR. 2. MOTION SENSOR CMR-9 FURNISHED BY AUTOZONE. W.H. A-27 3/16" = 1'-0" tlt—elec—plan 1/8" = 1'-0" tlt—elec—notes RESTROOM ELECTRIC PLAN 1 5 1 RESTROOM ELECTRICAL_ NOTES Lc� Q0 z O_ W N � U) W 0 0)Z CM v) J Q LL w � (0 (M O > >= 7 L Z Q N W O Z LLJ w N z3: n O O Q00 0 U� � o � 00 ' U 00 � O � v� U ct U o Q N . r cC3 U fn 05/28/2021 57N-REMODEL