HomeMy WebLinkAboutFL3607-E2-1-DOOR-ALARM-EAS-DETAILS-Model(1)2" x 4" J-BOX FOR
BURGLAR ALARM CONT
3/4" CONDUIT
F
2"x4"J-
HINGE
SIDE OF
DOOR.
3/4" CONDUIT TURN OUT ABOVE CEILING, OR
IF NO CEILING, AT UNDERSIDE OF ROOF DECK.
DUPLEX RECPT. CONNECT TO CIRCUIT LC-2
2" x 4" J-BOX FOR ACCESS CONTROL
KEYSCAN ENCLOSURE INSTALLED BY AZ ALARM
II II
CONTRACTOR OVER 2x4 J-BOX.
BOX 'I
II
II II
511
�
o
°:'
FIN.FL.
NACTIVE LEAF /
\ ACTIVE LEAF
4' x 4' J-BOX AT 80" A.F.F. FOR FIRE ALARM
HORN / STROBE
/ 2" x 4" J-BOX AT BOTH INSIDE AND OUTSIDE OF
WALL, CONNECT THREW TWO BOXES WITH %"
CONDUIT. EXTERIOR BOX FOR CARD READER
INSTALLED BY AZ ALARM CONTRACTOR.
\
2' x
4' J-BOX
FOR PULL STATION.
HINGE
SIDE
OF
DOOR.
CENTER EXIT LIGHT ABOVE ACTIVE LEAF AT 9'-0" A.F.F. TO BOTTOM OF SIGN.
1 1, —0"
1 ALARM-RECEIVING/EXIT DOOR -PR. 3'-0"x8'-0"
3/4" CONDUIT TURN OUT ABOVE CEILING, IF NO
CEILING, AT UNDERSIDE OF ROOF DECK.
4'X4'J-BOX AT80"
A.F.F. FOR FIRE ALARM
HORN / STROBE. 2"'X 4" J-BOX MOUNTED 6" ABOVE DOOR FOR
BURGLAR ALARM CONTACT
"II I
STRIKE
2 X 4 J-BOX AT 40 A.F.F. FOR PULL STATION.
2" X 4" J-BOX AT 40" A.F.F. FOR ALARM KEY
SWITCH.
NOTE:
J-BOXES ARE REQUIRED TO BE MOUNTED ON THE
STRIKE SIDE OF THE DOOR FRAME. SEE FLOOR
PLAN FOR DOOR LOCATIONS AND DOOR SWING.
HINGE SIDE OF DOOR.
FINISHED FLOOR
CENTER EXIT LIGHT ABOVE DOOR AT 9'-0" A.F.F. TO BOTTOM OF SIGN.
REFER TO FLOOR PLAN FOR LOCATION OF MAN DOORS. THIS ARRANGEMENT
IS REQUIRED AT EACH MAN DOOR.
ALARM —SWING 1" = 1'-0"
H.M.DOORS 2 ALARM - MAN DOOR
TRANSFORMER DUPLEX OUTLET
CABINET MOUNTED REMOTE ALARM BY AUTOZONE PLUG
OVER JUNCTION LET.
BOX. LC-8 n ----EXIT SIGN.
IT NO WALL SURFACE ABOVE
STOREFRONT MOUNT EQUIPMENT
ABOVE CEILING.
I__: WIREWAY SURFACE MOUNTED
_ ,cj-'�, TO FACE OF STOREFRONT.
cn �
c� Q
Q �
EAS POSTS BY AUTOZONE.
(-D 77C
TYP. 4 1 /2 X 1 3/4
ALUMINUM STOREFRONT.
TWO SURFACE MOUNTED WIREWAYS,
ONE FOR 120V. AND ONE FOR LOW
VOLTAGE WIRE, WITH MATCHING
SNAP -ON COVER.
EAS POSTS BY AUTOZONE.
0 0=
NOTES:
1. AUTOZONE'S EQUIPMENT INSTALLER WILL FURNISH & INSTALL ALL REQUIRED SECURITY ALARM EQUIPMENT INCLUDING FLOOR POSTS, TRANSFORMER
CABINET AND REMOTE ALARM SOUNDER AND COUNTER ABOVE THE DOOR.
2. GENERAL CONTRACTOR TO INSTALL JUNCTION BOX EITHER ON WALL ABOVE STOREFRONT, OR IF NO WALL SURFACE AVAILABLE THEN ABOVE CEILING
ALONG WITH DUAL WIREWAY ON THE SURFACE OF THE STOREFRONT IN ROUTING AS INDICATED TO CONNECT FLOOR -MOUNTED EAS POSTS BOTH TO THE
JUNCTION BOX ABOVE AND TO EACH OTHER.
3. GENERAL CONTRACTOR TO RUN 120 VOLT POWER FROM THE JUNCTION BOX ABOVE DOWN TO ONE OF THE PEDESTALS. LEAVE SNAP -ON COVER OFF
THE RACEWAY SO THAT AUTOZONE'S EQUIPMENT VENDOR CAN INSTALL BOTH THE CROSSOVER CONNECTION TO THE OTHER PEDESTAL AND LOW VOLTAGE
WIRING FOR THE SYSTEM.
ALARM —MAN 3/16" = 1'-0"
(interior view 3 ELECTRONIC SECURITY DETAIL
Dann
y Doss
EAS-PAIR
Digitally signed
by Danny Doss
Date:
2021.07.21
10:4024-05'00'
Lc_)
Q0
z
O_
w
CAI
►�
J
Q
rn
�
W
0
C�
Q
W
LL
o
_0
cc
CM
C
O
Z 2
Q
L_ (/) W
cq
J
Cn Z
�
Q
W
O Z
0
N
I—
0 N
0
0
Q
L
kn
U
� � ,_.j
S�
00
O N
U
o
M _M
U
Q'utn
�O1
•�,
b,A cC3 U
^
W �'��
ct ct
U 7� U
� M O W
o O•�
U
05/28/2021
57N-REMODEL