HomeMy WebLinkAboutFL3607-E2-POWER-POLE-PLAN-NOTES-Model(1)I --
CD
0
cl_�
Lr—
c�
El-
0
c—)
POWER POLE #I--
POWER POLE #`1
II ISTALL FLEX CABLE AND OUTLET 632
FOR COKE COOLER ON SURFAC;E ��
OF WALL
El
OFFICE AREA
INSTALL POWER POLE FOR TESTER
AGAIRST FIXTURE UPRIGHT, ANCHOR
TO ROOF DECK, AND STRAP POLE
TO OXTURE. OUTLETS IS POWER
POLE SHOULD FACE TESTER ROT
THE AISLE,
FOR CIRCUIT B-20 INSTALL 10 GAUGE
WIRE FROM THE BREAKER TO THE
JUNCTION BOX.
COMMERCIAL_ COUNTER
POWER POLE #6
CHECKOUT COUNTEFFOWER POLE #4
NARROW FIXTURE LAYOUT - UNDERCOUNTER WIRING
O OFFICE AREA POWER POLE - ALL CIRCUITS ARE HARD WIRED TO POLE FROM JUNCTION BOX WITH
FLEXIBLE CONDUIT.
OCHECKOUT COUNTER POWER POLE WITH ONE DUPLEX OUTLET PRE -WIRED ON POLE FOR
CONNECTION TO INDIVIDUAL CIRCUITS IN AUTOZONE FURNISHED QUICK CONNECTOR.
O PARTS POD POWER POLE WITH ONE DUPLEX OUTLET PRE -WIRED ON POLE FOR CONNECTION TO
AUTOZONE FURNISHED QUICK CONNECTOR.
40 TEST STATION POWER POLE WITH ONE SIMPLEX OUTLET AND ONE DUPLEX OUTLET PRE -WIRED ON
POLE FOR CONNECTION TO INDIVIDUAL CIRCUITS IN AUTOZONE FURNISHED QUICK CONNECTORS.
ATTACH TOP OF POWER POLE TO ROOF DECK AND STRAP POLE TO THE FACE OF THE FIXTURE
UPRIGHT. BOTTOM OF POLE SHOULD BE A MINIMUM OF 30" ABOVE FLOOR AND OUTLETS
SHOULD FACE THE TEST STATION.
O CAMERA SYSTEMS POWER POLE TO BE LOCATED ADJACENT TO POWER POLE # 1. POLE TO HAVE
TWO 10 FOOT LONG, 112" WHIPS WITH PULL WIRE. DO NOT PLACE ANY OTHER WIRE IN POLE.
O COMMERCIAL DESK POWER POLE WITH TWO DUPLEX OUTLETS PRE -WIRED ON POLE FOR
CONNECTION TO AUTOZONE FURNISHED QUICK CONNECTORS.
O FOR HUB STORES - TWO CHANNEL POWER POLE FURNISHED BY AUTOZONE.
NOTE: POWER POLES FOR ITEMS I * 5 WILL BE FURNISHED BY AUTOZONE AND WILL BE STANDARD LENGTH AND
MUST BE TRIMMED TO FIT IN THE FIELD. POWER POLES FOR ITEMS 2, 3, 4 * G WILL BE SUPPLIED WITH THE
STORE FIXTURES AND WILL HAVE MALE QUICK CONNECTORS ATTACHED TO THE POLE. EPPLOIrev
2 POWEP POLE LEGEND
Junction Box
FCKT 1
Drop Cable
DC 120 D U 01 Circuit Distributor
CD 120 D U 11
WIRING INSTRUCTIONS
POWER
FEED FROM
PANEL "LC"
120V CD
NTRL WHT NTRL
GND URN GND
HOT ELK HOT
1 st Circuit
OTES:
HORL
1. POWER POLE COMPLETE WITH
Nema 5-20R
DUPLEX OUTLETS AND DROP
Color: WHITE
CABLE WHIPS SUPPLIED BY
FIXTURE MANUFACTURER AND
INSTALLED BY OTHERS.
2. CIRCUIT DISTRIBUTOR WHIPS
FURNISHED BY AUTOZONE AND
INSTALLED BY GENERAL
CONTRACTOR AT ROOF DECK
JUNCTION BOX.
1/8" = 1'-0"
6 CHECK OUT POWER POLE2
Junction Box
FCKT 1
Drop Cable
DC 120 D U 01 Circuit Distributor
CD 120 D U 11
1 st Circuit
HOT
NIRL
Nema 5-20R
Color: WHITE
WIRING INSTRUCTIONS
POWER
FEED FROM
PANEL "LC"
120V CD
NTRL WHT NTRL
GND URN GND
HOT ELK HOT
OTES:
1. POWER POLE COMPLETE WITH
DUPLEX OUTLETS AND DROP
CABLE WHIPS SUPPLIED BY
FIXTURE MANUFACTURER AND
INSTALLED BY OTHERS.
2. CIRCUIT DISTRIBUTOR WHIPS
FURNISHED BY AUTOZONE AND
INSTALLED BY GENERAL
CONTRACTOR AT ROOF DECK
JUNCTION BOX.
EPP06 1/8" = 1'-0"
7 PARTS POD POWER POLE #3
I = �L=q= m4m
LC1
POWER POLE #2
POWER POLE #3
POWER POLE #3
1. CONNECT THE APPROPRIATE AUTOZONE FURNISHED PREWIRED FEMALE FLEXIBLE QUICK
CONNECTOR TO THE CIRCUIT(S) IN THE JUNCTION BOX SERVING EACH OF THE PODS.
SEE ADDITIONAL INFORMATION CONTAINED IN DETAIL 1 ON THIS SHEET. COIL UP THE
FLEXIBLE CONDUIT AND WIRE TIE TO THE CLOSEST BAR JOIST.
2. POSITION NON —POD POWER POLES AFTER FIXTURES ARE IN PLACE, ANCHOR ALL POLES
PER MANUFACTURER'S INSTRUCTIONS. MAKE FINAL CONNECTIONS THROUGH FLEX
CONDUIT TO JUNCTION BOXES AT ROOF DECK. POWER POLES FOR THE PODS WILL
COME WITH A MALE QUICK CONNECTOR AND WILL BE PLUGGED IN BY OWNER.
3. AT THE BOTTOM OF THE OFFICE POWER POLE MAKE 1 " FLEX CONNECTIONS TO
JUNCTION BOXES AND FROM THE JUNCTION BOX MAKE CONNECTIONS USING 3/8" FLEX
TO EACH OF THE DEVICES.
3 POWER POLE NOTES
Junction Box
FKCKT 1T 2
Drop Cable
DC 120 F U 01 2N
Circuit Distributor
CD 120 F U 11 2N
1st Circuit HOT 1
Nema 5-20R NTRL 1
Color: BROWN
2nd Circuit HOT 2
Nema 5-20R NTRL 2
Color: BROWN
The Simplex Outlet is
For The Tester
WIRING INSTRUCTIONS
POWER
FEED
NTRL 2 cRv NTRL 2
NTRL 1 wHT NTRL i
GND cRN cNo
HOT 1 BLK Hor i
HOT 2 REo Hor 2
NOTE:
HOT 2 & NTRL 2 TO BE WIRED TO THE
"B" PANEL CIRCUIT B-20
HOT 1 & NTRL 1 TO BE WIRED TO THE
"B" PANEL CIRCUIT B-24
OTES:
1. POWER POLE COMPLETE WITH
DUPLEX OUTLETS AND DROP CABLE
WHIPS SUPPLIED BY FIXTURE
MANUFACTURER AND INSTALLED BY
GENERAL CONTRACTOR.
2. CIRCUIT DISTRIBUTOR WHIPS
FURNISHED BY AUTOZONE AND
INSTALLED BY GENERAL CONTRACTOR
AT ROOF DECK JUNCTION BOX.
EPP01 1/8" = 1'-0"
8 TESTER POWER POLE #4
Junction Box
1 SEE SHEET E-1 FOR THE DIMENSIONAL LOCATIONS OF JUNCTION BOXES THAT WILL SERVE EACH OF THE
POWER POLES.
2 FOR THE OFFICE AREA AND CAMERA POWER POLES, RUN CONDUCTORS DOWN POLE AND OUT THROUGH A
1 INCH FLEXIBLE CONDUIT TO A JUNCTION BOX. MOUNT JUNCTION BOX ON WALL AT THE FLOOR LINE, IF
NO WALL SURFACE AVAILABLE THEN LEAVE JUNCTION BOX ON FLOOR ADJACENT TO POWER POLE.
3 RUN INDIVIDUAL CIRCUITS TO EACH
DEVICE AS
INDICATED IN
THE DRAWING IN 8 INCH FLEXIBLE CONDUIT.
4 TAG EITHER THE COVER PLATE OR
THE BOX IN
WHICH EACH
DEVICES IS PLACED WITH THE CIRCUIT
NUMBER SERVING THAT DEVICE.
5 FIXTURE LAYOUT MAY CONTAIN ONE
LESS HARD
PARTS POD
SEE OVERALL FIXTURE PLAN ON SHEET A-2
FOR TRUE NUMBER REQUIRED.
6 CHECKOUT COUNTER MAY CONTAIN
ONE MORE
SECTION THAN
SHOWN, HOWEVER, THE ELECTRICAL
REQUIREMENTS WILL NOT CHANGE FROM WHAT
IS CURRENTLY
INDICATED.
A.
LABEL ALL
CIRCUITS ON J-BOXES AND ALL OUTLETS
WITH MULTIPLE CIRCUITS.
B.
ALL WIRING
ON FLOOR UNDER COUNTERS SHALL BE
IN 3/8" FLEXIBLE CONDUIT,
C.
RUN ALL CONDUIT AND CABLES UNDER AND NOT
THROUGH SHELF SUPPORTS.
(�
SIMPLEX OUTLET
D.
DO NOT PERMANENTLY ATTACH OUTLET BOXES OR FLEX CONDUIT TO FLOOR.
E.
MOUNT OUTLETS IN KICKPLATES AFTER OWNER'S
FIXTURES HAVE BEEN INSTALLED.
DUPLEX OUTLET
F.
INSTALL JUNCTION BOXES AT LOCATIONS SHOWN
FOR POWER.
G.
AUTOZONE'S CONTRACTOR WILL INSTALL CAT. 5 CABLE FOR DATA AND PHONE LINES IN CONDUIT TO BE
INSTALLED UNDER THIS CONTRACT.
QUADRAPLEX OUTLET
H.
ALL CIRCUITS OVER 100 FEET IN LENGTH SHALL
BE RUN WITH #10 AWG.
I.
PROVIDE 2 PULL WIRES IN ALL EMPTY CONDUITS.
J.
LOCATE ALL POWER POLES AFTER FIXTURES ARE
IN PLACE.
O
JUNCTION BOX
K.
CONNECT OWNER FURNISHED PREWIRED FLEXIBLE
QUICK CONNECTORS, SEE ADDITIONAL NOTES THIS SHEEP.
EPPN01rev 14 GENERAL WIRING AND POWER NOTES
Drop Cable
DC 120 F U 01 2N
Circuit Distributor
CD 120 F U 11 2N
WIRING INSTRUCTIONS
POWER
FEED
NTRL 2 cRv NTRL 2
NTRL 1 wHT NTRL i
GND cRN cND
HOT 1 e K HOT i
HOT 2 RED HOT 2
NOTE:
HOT 2 & NTRL 2 TO BE WIRED TO THE
"LC" PANEL CIRCUIT
HOT 1 & NTRL 1 TO BE WIRED TO THE
"LC" PANEL CIRCUIT
1st Circuit HOT 1
Nema 5-20R NTRL 1
Color: WHITE
OTES:
1. POWER POLE COMPLETE WITH
2nd Circuit HOT 2
f
DUPLEX OUTLETS AND DROP
Nema 5-20R NTRL 2
Color: WHITE
CABLE WHIPS SUPPLIED BY
FIXTURE MANUFACTURER AND
INSTALLED BY OTHERS.
2. CIRCUIT DISTRIBUTOR WHIPS
FURNISHED BY AUTOZONE AND
INSTALLED BY GENERAL
CONTRACTOR AT ROOF DECK
JUNCTION BOX.
EPP03 1/8" — 1'-0" EPP02
9 COMMERCIAL COUNTER POWER POLE #6
WIRE —POWER —NOTES POWER— LEG EN D
5 POWER LEGEND
DannyDigitally signed
by Danny Doss
Date: 2021.07.21
DOSS 10:40:49 -051001
LC-)
Q0
z
CD
w
CAI
►�
(n
rn
W
Z
�Z
Q
ti
�
J
n-
CM
>
W
o �
Z
J
2
O
o Cq
W
v
n
Cn Z
W
N Z3:
_0 �
O
Q 00
0
°O
o 4'
r;
U o0
42
Q
N N
ct
v� U
ct
^^ct
05/28/2021
57N-REMODEL