HomeMy WebLinkAboutFL3607-E3-LIGHTING-Model(1)O
BOTTOM OF JOIST IS AT 13'-7" AT LOWEST POINT.
TALLEST MERCHANDISE SHELVES ARE 12'.
THIS BUILDING IS SPRINKLERED.
GC WILL BE RESPONSIBLE FOR PROVIDING
ALTERATION PLANS AND HIRING INSTALLERS.
SEE NOTES 10 AND 11 ON SHEET AO
LIGHTING
1 /8" = 1 ' -0"
TO JUNCTION BOX MAXIMUM 6'
FLEX CONDUIT ATTACHED TO UNISTRUT AT END OF LIGHT RUN
UNLESS INDICATED OTHERWISE.
ATTACH UNISTRUT WITH STEEL WASHER & 3/8" ALL THREAD ROD THRU JOIST CHORD
LED STRIP FIXTURE, ATTACH LIGHT FIXTURE TO UNISTRUT WITH 3/8"
BOLT THRU KNOCKOUT SECURE WITH WASHER & LOCKNUT
T� JUNCTION BOX M'
AXIMUM 6
EX CONDUIT RUN THRU JOIST CHORD AT END OF LIGHT RUN
ATTACH FIXTURE WITH STEEL WASHER, 3/8" ALL THREAD ROD AND
LOCKNUTS, THRU CENTER OF BOTTOM JOIST CHORD
BOTTOM CHORD OF BAR JOIST
� � I LOCKNUT & WASHER
GALVANIZED UNISTRUT TO BE 14 GAUGE," x 1 $" HALF SLOT CHANNEL MOUNTED TIGHT TO STRIP FLUORESCENT FIXTURE
BOTTOM OF JOISTS. WHERE LIGHT FIXTURES ARE PARALLEL TO JOISTS, RUN UNISTRUT NOTE: SPACING OF FIXTURE SUPPORTS ARE TO BE IN ACCORDANCE WITH THE CURRENT
PERPENDICULAR TO THE JOISTS. WHERE LIGHT FIXTURE ARE ANGLED TO JOISTS, OR HUNG BETWEEN EDITION OF NATIONAL ELECTRIC CODE.
1/8" = 1'-0"
JOISTS
RUN UNISTRUT PERPENDICULAR TO
LIGHTS.
ELS01 LED
1/8"
= 1'-0"
5
LED
STRIP
FIXTURE
MOUNTING
DETAIL
BETWEEN
JOISTS
I 6
FLUORESCENT
MOUNTING
DETAIL
FIXTURE
AT
JOIST
A. ALL DIMENSIONS ARE FROM FACE OF EITHER CMU OR FINISHED WALL AND TO THE EDGE, CENTER OR ENDS OF LIGHT FIXTURES.
B. INSTALL MOTION SENSOR ON BATHROOM CEILING TO CONTROL LIGHT / FAN.
C. RUN ALL CONDUIT IN STRICT CONFORMANCE WITH CURRENT VERSION OF THE NATIONAL ELECTRIC CODE APPLICABLE TO THE
PROJECT. CONDUIT SHALL BE INSTALLED EITHER PARALLEL OR PERPENDICULAR TO DECK RIBS. USE FLEX CONDUIT FROM
J-BOX TO TO LIGHT FIXTURE.
D. INSTALL 8'-0" LONG LED FIXTURES EITHER TO THE BOTTOM OF ROOF STRUCTURE MEMBERS, UNISTRUT, OR SUSPENDED CEILING
GRID AS SHOWN AND CALLED FOR ON THE DRAWINGS,
E. EXIT AND EMERGENCY LIGHTS SHALL BE MOUNTED ON WALLS, ATTACHED TO UNISTRUT OR THE CEILING GRID AS INDICATED.
F. FRONT DOOR EXIT SIGN: SURFACE MOUNT ON WALL 9'-0" A.F.F. TO BOTTOM OF FIXTURE MAN DOOR EXIT SIGN: SURFACE MOUNT
ON WALL 9'-0" A.F.F. TO BOTTOM OF FIXTURE.
G. ALL NON -SWITCHED LIGHTING CIRCUITS TO BE CONTROLLED BY AUTOMATIC LIGHTING CONTROL PANEL. SEE LIGHTING CONTROL
DIAGRAM FOR DETAILS AND REQUIREMENTS,
H. NO INTERIOR LIGHTING BRANCH CIRCUIT SHALL BE INSTALLED IN A MULTIWIRE BRANCH CIRCUIT. NEUTRAL CONDUCTORS SHALL
NOT BE SHARED BETWEEN DIFFERENT CIRCUITS.
1/8"=1'-0" LED Itg—notes
1 LED LIGHTING NOTES
1. ALL WALL SIGNS SHALL BE
INSTALLED BY
AUTOZONE'S SIGN VENDOR WHO
WILL PUSH SIGN WIRING THROUGH WALL
ASSEMBLY. CONNECTIONS OF
SIGN WIRING TO
HOME RUN CIRCUITRY WILL BE
BY GENERAL CONTRACTOR.
2. FOR ALL REMOTE CHANNEL
LETTER SIGNS
AUTOZONE'S SIGN VENDOR WILL
INSTALL AN INTERIOR SURFACE MOUNTED
RACEWAY FOR TRANSFORMERS
AND WIRE, SO
THAT GENERAL CONTRACTOR CAN
TIE ALL INDIVIDUAL LETTER WIRING
TOGETHER AND THEN CONNECT TO THE HOME
RUN CIRCUIT.
3. SIGN VENDOR SHALL BE RESPONSIBLE FOR SEALING ALL OF HIS WIRING PENETRATIONS THROUGH THE EXTERIOR
WALLS WITH THE EXCEPTION OF PENETRATIONS THROUGH PARAPET WALLS OR ROOFING. THOSE PENETRATIONS SHALL
BE SEALED BY GENERAL CONTRACTOR SO AS NOT TO VOID ANY WARRANTY CONNECTED WITH THE ROOFING
INSTALLATION. GENERAL CONTRACTOR SHALL PAINT ALL EXPOSED BOXES, CONDUIT AND RACEWAYS TO MATCH
SURROUNDING WALLS SURFACES.
ENNO1
3 SIGNAGE INSTALLATION GENERAL NOTES
FIXTURE TYP
A -7� -A-28
CONNECT TO CIRCUIT ,i# INDICATES BRANCH CIRCUITING REFTER TO PANEL
SCHEDULE LONG =NEUTRAL; SHORT =PHASE
LIGHTING FIXTURE CIRCUIT
1 /8" = 1'-0"
ELL01
3
LIGHTING CIRCUT SYMBOLS
SYMBOL
DESCRIPTION
SUPPLIED
LAMPS
MOUNTING
A
8' LED STRIP 42 WATTS INPUT
AUTOZONE
4 - 10.5 WATT T8 -
4' LED TUBE
SEE PLAN FOR LOCATIONS
B
8' LED STRIP 21 WATTS INPUT
AUTOZONE
2 - 10.5 WATT T8 -
4' LED TUBE
SEE PLAN FOR LOCATIONS
°
C
4' LED STRIP 10.5 WATTS INPUT
WALL LIGHT
AUTOZONE
1 - 10.5 WATT T8 -
4' LED TUBE
SURFACE MOUNTED @ 6'-8" ABOVE FINISHED
FLOOR CENTER ON WALL
H�-D
D—Series Size 1 Luminaire DSXW1 LED
1OC 1000 40K T3M MVOLT
AUTOZONE
40 WATT
REPLACE EXISTING FIXTURE
E
EMERGENCY LIGHT WITH BATTERY
BACKUP
AUTOZONE
INCLUDED WITH FIXTURE
MOUNTED TO BOTTOM OF BAR
JOIST OR UNISTRUT
F
EXIT SIGN WITH BATTERY
BACKUP FOR REMOTE EXIT
EMERGENCY HEAD
AUTOZONE
INCLUDED WITH FIXTURE
SEE PLAN FOR LOCATIONS AND
MOUNTING INFORMATION
G
EXISTING RECESSED DOWN LIGHT
EXISTING
EXISTING
RELAMP AND PLACE IN GOOD
WORKING CONDITION
EXTERIOR EMERGENCY LIGHT
WITH TWO HEADS
AUTOZONE
INCLUDED WITH FIXTURE
REMOTE HEAD MOUNTED OUTSIDE ABOVE DOOR
WIRE TO EXIT LIGHT FIXTURE
K
EXIT SIGN WITH BATTERY BACKUP
AUTOZONE
INCLUDED WITH FIXTURE
MOUNTED TO BOTTOM OF BAR JOIST OR UNISTRUT
L
D—Series Size uminai
E
TOREFRONT
4' LED STRIP 21 A
2 - 10.5 A -
4 LED T
CATIONS
°
N
4' LED STRIP 10.5 A
1 - 10.5 WATT 18-
4 LEDRIAN
EDE 10CATIONS
° 1
O
MOTION SENSOR FOR ALC PANEL
AUTOZONE
— — — — —
J-BOX HORIZONTAL BOTTOM OF JOIST OR UNISTRUT
M1
OCCUPANCY SENSOR-CMR-9
AUTOZONE
RESTROOM CEILING - CONNECT TO FAN & LIGHT
SITE LIGHT
60C 1000 4
OLE AND FIXTURE
I
LIGHT FIXTURE SCHEDULE NOTES:
1. NOT EVERY SYMBOL WILL BE UTILIZED ON EACH PROJECT SEE FLOOR PLAN ON THIS SHEET FOR THE ITEMS THAT APPLY TO THIS
SPECIFIC PROJECT.
2. AUTOZONE WILL FURNISHED LED STRIP FIXTURES AND MOTION SENSORS SHOWN IN SCHEDULE ABOVE AND CALLED FOR ON THE PLAN.
SEE MOUNTING DETAILS THIS SHEET,
3. MOTION SENSOR M2 WILL BE USED IN HUB AND MEGA HUB STORES ONLY.
ELS02 1/8" = 1'-0 ELC01LED
4 L GHT FIXTURE SCHEDULE
Lc_)
C-0
z
0
w
CAI
►�
vJ
Q
W
rn
W
JO
LL
Z
ti
O
M
Z
Q
�
O
J
Z =
^
..
ocf)
cD
Lu
U
CD
Z
Z
w
N z
I-
_
O4_0
V
Q
J
� O
�
00 o
�
' U 00
M
�
W
U U o
o
IT
DanDigitally
signed by
Danny Dos
n Y
Date:
2021.07.21
10:41:17
Doss-05'00'
05/28/2021
57N-REMODEL
E
3