HomeMy WebLinkAboutFL3607-E4-PANEL-SCHEDULE-Model(1)ARC -FLASH SCHEDULE DEVICE VOLTAGE INCIDENT ENERGY (J/CMZ) WORKING DISTANCE ARC -FLASH BOUNDARY DISTANCE A 208V 3.14 18" V-1 " LC 208V 3.09 18" V-1 " B 208V 3.25 18" 1'-2" MAIN DISCON 1 gnR\i gn aE UNKNOWN ?'-n" IVLvy `L/T'lrJ/ U, n'LU, L U l.0 e NEW PANEL A e e NEW PANEL LC e 225A TOOA 200A MCB e e e a e e 208Y/120V 3P 4W e e 208Y/120V 3P 4W e PROVIDED BY AUTOZONE PROVIDED BY AUTOZONE NEW 4#6, #10G, 1"C CU CONTRACTOR SHALL CONFIRM THAT THE EXISTING GROUNDING SYSTEM INSTALLATION IS IN COMPLIANCE WITH NEC 2017 ARTICLE 250. REPAIR OR REPLACE AS REQUIRED. CONTRACTOR SHALL VISIT THE SITE AND PERFORM A COMPLETE FIELD SURVEY PRIOR TO BID AND/OR CONSTRUCTION COORDINATE ALL WORK WITH SERVING UTILITY COMPANY REQUIREMENTS AND MAKE CONTACT WITH LOCAL REPRESENTATIVE PRIOR TO BID AND/OR CONSTRUCTION. PRIOR TO BID, NOTIFY AUTOZONE AND THIS ENGINEER, IN WRITING, OF ANY CHANGES REQUIRED. 3/32" = 1'-O" EXD01 2 SCHEMATIC ONE LINE ELECTRICAL SERVICE WIREWAY BONDING JUMPER-#2 CU COMMUNICATIONS BONDING JUMPER - #6 CU SERVICE EQUIPM SUPPLY SIDE BONDING JUMPER - #2 CU EQUIPMENT BONDING JUMPER-#2 CU NEUTRAL- EQUIPMENT BUS GROUNDING BUS BONDING JUMPER. - #2 CU BUILDING STEEL, #2 CU;7--GROUNDING ELECTRODE CONDUCTOR PER N.E.C. 250 - #2 CU INTERIOR METAL WATER PIPE, #2 CU WITHIN FIRST 5' IF CONTINUOUS GROUND ROD FOR AT LEAST 10'. SYSTEM PER N.E.C. 250 WITH RESISTANCE TO GROUND OF 25 OHMS OR LESS. #2 CU GROUNDNIG ELECTRODE SYSTEM- N. T. S. SERMCE TOTALS LIGHTING 5,900 LARGEST MOTOR 12,400 OTHER MOTORS 37,200 RECEPTACLES 25,100 VOLTAGE DROP NOTES** CONN. VA CALC. VA 7,380 (1257.) CONTINUOUS 2,730 3,410 (1257.) 15,500 (1257.) HEATING 0 0 (100%) 37,200 (1007.) NONCONTINUOUS 2,780 2,780 (1007.) 17,600 (507.>10) KITCHEN EQUIP 0 0 (N/A) NONCOIN/DIVERSE 0 0 (N/A) TOTAL VA 86,100 83,800 BALANCED THREE PHASE AMPS 233 NEUTRAL HOMERUN TO PANEL INDICATED (CONCEALED). MINIMUM 3/4" CONDUIT. UNLESS OTHERWISE NOTED PROVIDE #12 CONDUCTORS AS REQUIRED BY THE NUMBER OF CIRCUITS SHOWN. INCLUDE #12 GROUND AND #12 NEUTRAL CONDUCTORS. GROUND HOT FOR HOMERUNS EXCEEDING 75 USE THE NEXT TABLE TO SIZE THE CONDUCTORS: 0 - 75 Feet-------------#12 AWG 75 - 150 Feet------------#10 AWG 150 - 250 Feet -----------# 8 AWG 250 - 350 Feet -----------# 6 AWG THERE SHALL BE A MAXIMUM OF 2 BRANCH CIRCUITS FOR SINGLE PHASE AND 3 BRANCH CIRCUITS FOR THREE PHASE PER HOMERUN (AS INDICATED ON THE PLANS). TEXT SHOWN BY HOMERUN INDICATES PANELBOARD DESIGNATION AND CIRCUIT NUMBER(S). CONDUIT CONCEALED IN WALL OR ABOVE CEILING SPACE. UNLESS OTHERWISE NOTED PROVIDE #12 CONDUCTORS AS REQUIRED BY THE NUMBER OF CIRCUITS SHOWN. INCLUDE #12 GROUND AND #12 NEUTRAL. MINIMUM 3/4" CONDUIT. UNDERGROUND OR BELOW SLAB CONDUIT. UNLESS OTHERWISE NOTED PROVIDE #12 CONDUCTORS AS REQUIRED BY THE NUMBER OF CIRCUITS SHOWN. INCLUDE #12 GROUND AND #12 NEUTRAL. MINIMUM 3/4" CONDUIT. PANELS AND THEIR CIRCUITS TO BE IDENTIFIED PER NEC SECTION 408.4 (A) & (B) PANELS TO BE IDENTIFIED FOR ARC FLASH HAZARD PER NEC SECTION 110.16. A ROOM VOLTS 208Y/120V 3P 4W AIC 10,000 MOUNTING FLUSH BUS AMPS 225 MAIN BKR 200 FED FROM WIREWAY NEUTRAL 100% LUGS STANDARD NOTE CKT CKT VA LOAD CKT CKT VA LOAD # BKR CIRCUIT DESCRIPTION # BKR CIRCUIT DESCRIPTION A B C A B C 1 20/1 LIGHTING 1,490 2 20/1 LIGHTING 672 3 20/1 LIGHTING 432 4 20/1 LIGHTING 720 5 20/1 LIGHTING 720 6 20/1 FRONT WALL SIGN 1,220 7 -/1 SPACE 0 8 -/1 SPACE 0 9 20/1 EXIT/EMERGENCY LIGHTING 64.8 10 -/1 SPACE 0 11 -/1 SPACE 0 12 -/1 SPACE 0 13 20/1 EXTERIOR BLDG. LIGHTING 38.8 14 -/1 SPACE 0 15 20/1 CANOPY LIGHTING 147 16 -/1 SPACE 0 17 -/1 SPACE 0 18 -/1 SPACE 0 19 -/1 SPACE 0 20 -/1 SPACE 0 21 -/1 SPACE 0 22 20/1 RESTROOM LTS/FANS 400 23 -/1 SPACE 0 24 -/1 SPACE 0 25 -/1 SPACE 0 26 -/1 SPACE 0 27 20/1 WATER HEATER 1,500 28 -/1 SPACE 0 29 -/1 SPACE 0 30 -/1 SPACE 0 31 50/3 RTU-4 4,130 32 -/1 SPACE 0 33 1 4,130 34 -/1 SPACE 0 35 1 4,130 36 -/1 SPACE 0 37 -/1 SPACE 0 38 60/3 PANEL LC 5,970 39 -/1 SPACE 0 40 1 3,700 41 -/1 SPACE 0 42 1 5,560 TOTAL CONNECTED VA BY PHASE 12,300 11,100 11,600 TOTAL CONNECTED AMPS BY PHASE 102 92.5 96.9 CONN. VA CALC. VA CONN. VA CALC. VA LIGHTING 5,900 LARGEST MOTOR 12,400 OTHER MOTORS 0 RECEPTACLES 14,000 7,380 (1257.) CONTINUOUS 2,730 15,500 (1257.) HEATING 0 0 (1007.) NONCONTINUOUS 0 12,000 (507.>10) KITCHEN EQUIP 0 NONCOIN/DIVERSE 0 TOTAL VA 35,000 BALANCED THREE PHASE AMPS 106 3,410 (1257.) 0 (1007.) 0 (1007.) 0 (N/A) 0 (N/A) 38,300 B ROOM VOLTS 208Y/120V 3P 4W AIC 10,000 MOUNTING FLUSH BUS AMPS 225 MAIN BKR 200 FED FROM WIREWAY NEUTRAL 100% LUGS STANDARD NOTE CKT CKT VA LOAD CKT CKT VA LOAD # BKR CIRCUIT DESCRIPTION # BKR CIRCUIT DESCRIPTION A B C A B C 1 50/3 RTU-1 4,130 2 50/3 RTU-2 4,130 3 1 4,130 4 1 4,130 5 1 4,130 6 1 4,130 7 50/3 RTU-3 4,130 8 -/1 SPACE 0 9 1 4,130 10 -/1 SPACE 0 11 1 4,130 12 -/1 SPACE 0 13 20/1 RTU MAINT & OX-BLUE RECEPTACLE 900 14 -/1 SPACE 0 15 20/1 BATTERY CHARGER 1,490 16 -/1 SPACE 0 17 20/1 BATTERY CHARGER 1,490 18 -/1 SPACE 0 19 20/1 BATTERY CHARGER 1,490 20 20/1 MINI -TUNE 1,500 21 20/1 BATTERY CHARGER 1,490 22 -/1 SPACE 0 23 20/1 BATTERY CHARGER 1,490 24 20/1 TEST ACCESSORIES 800 25 20/1 ALC PANEL 480 26 20/1 DRINKING FOUNTAIN 480 27 -/1 SPACE 0 28 -/1 SPACE 0 29 20/1 BREAK ROOM FRIDGE 400 30 20/1 GENERAL RECEPTACLE 720 31 -/1 SPACE 0 32 20/1 DRINK MACHINE 1,200 33 -/1 SPACE 0 34 -/1 SPACE 0 35 -/1 SPACE 0 36 -/1 SPACE 0 37 -/1 SPACE 0 38 -/1 SPACE 0 39 -/1 SPACE 0 40 -/1 SPACE 0 41 -/1 SPACE 0 42 -/1 SPACE 0 TOTAL CONNECTED VA BY PHASE 18,400 15,40017,300 TOTAL CONNECTED AMPS BY PHASE 154 128 144 CONN. VA CALC. VA CONN. VA CALC. VA LIGHTING 0 0 (1257.) CONTINUOUS 0 0 (1257.) LARGEST MOTOR 12,400 15,500 (1257.) HEATING 0 0 (1007.) OTHER MOTORS 24,800 24,800 (1007.) NONCONTINUOUS 2,780 2,780 (1007.) RECEPTACLES 11,100 10,600 (507.>10) KITCHEN EQUIP 0 0 (N/A) NONCOIN/DIVERSE 0 0 (N/A) TOTAL VA 51,100 53,600 INSERT 20 AMP HIGH MAGNETIC BREAKER IN CIRCUIT B-20. BREAKER BALANCED THREE PHASE AMPS 149 WILL COME WITH A YELLOW STICKER TO BE LEFT IN PLACE. C ROOM VOLTS 208Y/120V 3P 4W AIC 10,000 MOUNTING FLUSH BUS AMPS 100 MLO FED FROM A NEUTRAL 100% LUGS STANDARD NOTE CKT CKT VA LOAD CKT CKT VA LOAD # BKR CIRCUIT DESCRIPTION # BKR CIRCUIT DESCRIPTION A B C A B C 1 20/1 CK OUT REG & PRN 1,920 2 20/1 ALARM RECEPTACLE 400 3 -/1 SPACE 0 4 20/1 OFFICE TRAINING 1,920 5 20/1 CCTV MONITOR 300 6 20/1 OFFICE IT 1,920 7 20/1 POD #1 1,920 8 20/1 EAS POST & ALARM 930 9 -/1 SPACE 0 10 20/1 OFFICE UPS 260 11 20/1 POD #2 800 12 20/1 COMMERCIAL 1,820 13 -/1 SPACE 0 14 20/1 COMMERCIAL 800 15 20/1 ALARM 720 16 20/1 COMMERCIAL 800 17 20/1 TEL CO 720 18 -/1 SPACE 0 19 -/1 SPACE 0 20 -/1 SPACE 0 21 -/1 SPACE 0 22 -/1 SPACE 0 23 -/1 SPACE 0 24 -/1 SPACE 0 TOTAL CONNECTED VA BY PHASE 5,970 3,700 5,560 TOTAL CONNECTED AMPS BY PHASE 49.8 30.8 46.3 CONN. VA CALC. VA CONN. VA CALC. VA LIGHTING 0 LARGEST MOTOR 0 OTHER MOTORS 0 RECEPTACLES 14,000 0 (1257.) CONTINUOUS 1,230 0 (1257.) HEATING 0 0 (1007.) NONCONTINUOUS 0 12,000 (507.'>10) KITCHEN EQUIP 0 NONCOIN/DIVERSE 0 TOTAL VA 15,200 BALANCED THREE PHASE AMPS 37.6 1,540 (1257.) 0 (1007.) 0 (1007.) 0 (N/A) 0 (N/A) 13,500 Lc-) (_0 VJ W J z 0 W O w U .J W z Ir- L 0') C`7 Q L.L V _I Q L.L Q O M W U z > (2) cl) o W U 0 zLu �W/� VJ W oZ a_ z_ O CV � O J 1 00 Q 00 O U W � O � •� 0 ct N ;_4 r-, cj C U 5 W,a)�� rdQ a a) .�cn M o W�P4E-+ W o o• rQU )an signed by Danny Y Doss Date: 2021.07.21 0 S S 10:41:44 -05'00' 05/28/2021 57N-REMODEL E�4