HomeMy WebLinkAboutFL3607-M1-1-Model(1)BOTTOM OF TRUSS 2" 1. YORK ROOF TOP UNITS ALONG WITH ANY ACCESSORIES WILL BE
CHORD FURNISHED TO THE JOB SITE ON A SCHEDULED DELIVERY BASIS.
1-1/4"CD THE CURBS WILL COME SEPARATELY FROM A THIRD PARTY YORK
WATER METER MIN. VENDOR. ALL ITEMS MUST BE REQUESTED WITH A NEEDED
SCOPE OF WORK_ PENETRATION DELIVERY DATE IN THE AFI SCHEDULE REQUEST FORM AND SENT
_ X 18 GAGE STRAP (1) #10 X 2 SHEET METAL
`� 1. REMOVE (4) EXISTING RTUs, CURBS, DUCT
HANGERS AT 8'-0" SCREWS ® EACH TRUSS CHORD TO THE VENDOR AS SOON AS THE JOB NTP'S.
SPACING. (nP) 2. ONCE CONSTRUCTION HAS COMMENCED IT WILL BE THE
CD RUNOUTS, AND DUCT LINE (RTU1 ONLY). #10 X 3/4" SELF TAPPING CADMIUM GENERAL CONTRACTOR'S RESPONSIBILITY TO STAY IN TOUCH WITH
c' PLATED SHEET METAL SCREWS TO
ccl�2. I N STALL STRUCTURAL SUPPORT FOR NEW RTU s - ANCHOR STRAPS To DUCT. THE YORK CONTACT AND TO SCHEDULE THE ACTUAL DATE THE
SEE STRUCTURAL DRAWINGS. ROOF TOP UNIT ARE TO BE DELIVERED TO THE JOB SITE.
ALL STRAPS TO BE TIGHT AGAINST 3. IT IS EXPECTED THAT WHEN UNITS ARE DELIVERED THEY WILL
3. INSTALL NEW RTUs AND CURBS PER PLAN. DUCT AND SUPPORT GO FROM TRUCK TO ROOF AND NOT BE LEFT ON THE GROUND.
COORDINATE ROOF ACTIVITIES WITH LANDLORD MEMBER .(TYPICAL) IF THE JOB SCHEDULE WILL NOT ACCOMMODATE THE ORIGINAL
1" RIGID INSULATION ON TH NO POP RIVETS ALLOWED REQUESTED DELIVERY DATE THEN THE GENERAL CONTRACTOR MUST
ROOF CONTRACTOR. INSIDE OF THE DUCT CALL YORK AND RESCHEDULE. UNITS ARE NOT TO BE LEFT ON
DUCT -STRAP -HANGER THE GROUND WHERE THEY MAY BE SUBJECT TO DAMAGE.
4. INSTALL DUCTS, DIFFUSERS PER PLAN. USE 1 * 1 * 1 DUCT STRAP HANGER DETAIL 4. WHEN UNITS ARRIVE THEY SHOULD BE INSPECTED FOR
EXISTING DUCT MAIN LINES WHERE SHOWN. SET RTU RTU RTU 4 ELECTRICAL METERS DAMAGE, AS THE AUTOZONE POLICY ONLY ALLOWS THE GENERAL
ALL DUCTS AS HIGH TO ROOF DECK AS POSSIBLE. oo CFM ® 40o CFM ® FM 40o CFM ®1 CONTRACTOR 72 HOURS TO REPORT DAMAGE OR ANY PROBLEM,
1OX10 SA 10X10 SA lox 0 SAG 1OX10 SAG AFTER WHICH THE ISSUE BECOMES THE CONTRACTORS TO
5. INSTALL RESTROOM EXHAUST THROUGH ROOF WITH 406 CFM OX10F AG RESOLVE. IF THE DAMAGE IS SUPERFICIAL OR COSMETIC THEN
L1OX10 SAG THE UNITS SHOULD BE ACCEPTED, INSTALLED AND REPAIRED IN
RAIN HOOD �C BIRD SCREEN. EXISTING DUCT
Ix1sTING DUCT THE FIELD. IF THE DAMAGE AFFECTS THE OPERATION OF THE
6. INSTALL ENERGY MANAGEMENT SYSTEM PER RUNK TO EMAIN RUNK TO REMAIN UNIT THEN IT SHOULD BE NOTED ON THE BILL OF LADING, NOTIFY
ELECTRICAL DRAWINGS. YORK TO SCHEDULE A REPLACEMENT AND PICK-UP, AND NOTIFY
THE AUTOZONE AFI MANAGER, SEE AUTOZONE AFI POLICY FOR
EXISTING DUCT ADDITIONAL INFORMATION.
TRUNK TO REMAIN 5. CONTACTS:
W TO SCHEDULE DELIVERY: SHAWNA STEPHENS 405-419-6272
TO REPORT DAMAGE: JESSICA RIBBLE 405-419-6676
1 FOR TECHNICAL SUPPORT: JASON MCDANIEL 405-419-6853
CENTERLINE R = 1.5 X W AUTOZONE AFI MANAGER: LEW ELLIS 901-495-8707
I II I I I I I I I I I
RADIUS -ELBOW 1/8" = 1'-0" MHN07
400 CFM
1 11OX10 SAG 2 RADIUS ELBOW 9 YORK HVAC NOTES
I I
400 CFM 400 CFM 400 CFM 400CFM 400 CFM 400CFM L 1. DOA (Dead on Arrival): LABOR ALLOWANCES APPLY ONLY TO
1OX10 SAO 11OX10 SAG I I 11OX10 SA 1OX110 SAG I 11OX10 SAGI 10X110 SAG L = 1 /4 W, THOSE SITUATIONS WHERE DEFECTS HAVE OCCURRED DIRECTLY AS
- 4" MIN. A RESULT OF FACTORY WORKMANSHIP AND/OR MATERIALS.
REIMBURSEMENT WILL NOT BE ALLOWED WHERE DAMAGE HAS BEEN
SUSTAINED AS A RESULT OF MISAPPLICATION OR IMPROPER
1 AINSTALLATION.
ANEL "B 2. FOR ALL DOA AND ANY OTHER WARRANTY ISSUES THE
\ 1 CONTRACTOR SHALL CALL THE YORK WARRANTY GROUP FOR
ANEL "A" 1 PANEL L INSTRUCTIONS ON HOW TO PROCEED. YORK WILL RESPOND TO
RTLI
U ALL WARRANTY REQUESTS OR ISSUES WITHIN 24 HOURS.
1 40o CFM PROCEEDING WITH WORK IN ADVANCE OF NOTIFYING YORK MAY
1ox10 sac i
400 CFM 45°
RESULT IN CONTRACTOR NOT BEING REIMBURSED FOR ALL OF HIS
I I I I I I I I I I
1OX10 SAGI COSTS,
1 120x161 CLOSE OPENING 3. AS YORK HAS PRE ASSIGNED LABOR VALUES TO ALL PARTS OF
AT CORNERS THE ROOF TOP UNIT, CONTRACTOR MUST GET YORK'S
j 3 RECTANGULAR BRANCH DUCT TAKEOFF CONCURRANCE IN THE CONTRACTOR'S ESTIMATED LABOR CHARGE
400 ICFM 1 u SPUTTER TO DO THE WORK PRIOR TO COMMENCING, OR CONTRACTOR MUST
\ 1OX1P AG DAMPER 400 CFM 400 CFM 400 CFM 400 FM 400 CFM 400 CFM PROVIDE NYLON o SEE PLANS FOR AGREE TO YORK'S LABOR ALLOWANCE. PARTS WILL BE FURNISHED
12x12 1OX10 SAC 1OX10 SAG 10X1o;SA 10X1 AG 1OX10 SAG 10X1 AG BEARING ON 90 AT NO COST BY YORK, THEY MAY ASK CONTRACTOR TO RETURN
1OX10
c 400 CFM 40o IDS DAMPER SHAFT RUNOUT SIZES THE DEFECTIVE PART AND CONTRACTOR MUST DO SO.
10X10 AG 1OX10 1 Ac 4. FOR EXPEDITED SERVICE CONTRACTOR SHOULD HAVE THE
\\ \ 2x12 PROVIDE MANUAL MODEL AND SERIAL NUMBER OF THE UNIT IN QUESTION PRIOR TO
\ BUTTERFLY 1 MAKING A CALL FOR WARRANTY SERVICE.
DAM\\ I I BRAPER IN CH TAKEOFF I 1 � 5. CONTACTS:
N I FOR WARRANTY ISSUES: JESSICA RIBBLE 800-481-9738 OPTION 4
\\ _ _ PROVIDE FOR TECHNICAL SUPPORT: LEROY BERRY 800-481-9739 OPTION 4
STANDOFF 45°
INSULATION
HVAC P L_A N BRACKET ON
\\ 1 /8" = 1 '-0" INSULATED DUCTS SPIN -IN FITTINGS W/SCOOPS ARE
\ NOT ACCEPTABLE 1 /8" = 1'-0" MHN04
7/7
4 ROUND BRANCH DUCT TAKE -OFF 10 YORK WARRANTY NOTES
FACTORY MOUNTED AND WIRED MARK MODEL CFM @ SONES ELEC. REQUIREMENT 1. All air diffusers and return air grills are new, to be supplied
BRAND
NON -FUSED DISCONNECT WEATHERPROOF J-BOX MOUNT 1 8 S.P. and installed by the general contractor.
TO ORTH EXTERIOR TEMP. SENSOR RTUNMOUNT ALCPGPHOTOCELL
SIDE OF TEF-1 BROAN 503 160 5 120V-1PH-60HZ
TO CONTROLS IN RTU CONTRACTOR SUPPLIED TO J-BOX AND WIRE THRU TEF-2 BROAN 503 160 5 120V-1 PH-60HZ
CONVENIENCE OUTLET BY ELECTRICAL WEATHER-PROOF GFI CONVENIENCE UNIT TO J-BOX AT DECK LEGEND FOR NEW GRILLES
CONTRACTOR. SEE SHEET E1. OUTLET (ONE PER RTU) BELOW. INTERLOCK EXHAUST FANS WITH LIGHTING CONTROLS INDICATES ROOF OPENING
ECONOMIZER
24"x24" or 24"x48" RETURN AIR CLG. GRILLS TITUS MODEL # 50F, T-BAR ELt
FLASHING AND FIBER CONDENSATE DRAIN LAY -IN. R/A= SEE PLAN ELECBY TRICAL DISCONNECT PROVIDED
CANT STRIP AT CANT STRIP
MECHANICAL ROOF CURB
(ROOF CURB FURNISHED SMOKE DETECTOR IS FACTORY RTU ROOF DECK TU L SIDE WALL GRILLE, TITUS MODEL # 300 WITH
REFER TO STRUCTURAL PLANS OUNTER- FLASHING BY - DOUBLE DEFLECTION, FRONT BLADES SHALL
BY RTU SUPPLIER) FOR PROPER ROOF CURB MOUNTED IN THE RETURN AIR �J "" GENERAL CONTRACTOR \` SAG BE PARALLEL WITH WIDTH = SEE PLAN FOR
MOUNTING DETAILS. SECTION OF THE ROOFTOP SDETMK SIZE AND AIR FLOW.
UNIT. 1 PAIR 18 GAUGE, T-PLL
1/8" = 1'-0" hvac-legend
SHIELDED CABLE BETWEEN Se -
RETURN SMOKE DETECTOR AND RTU STRAP ANCHORS 7 T01 LET EXHAUST FAN SCHEDULE 1 1 HVAC LEGEND
METAL STRAP AIR � CONTROLS I \ / SUPPL
SUPPLY I
MANUFACTURER SUPPLY AIR COOLING DATA HEAT PUMP � \ ELECTRICAL REQ. BREAKER
SUPPLY MARK MODEL NO. MIN. O.S.A. T. AIR TOTAL COOLING EER ENT. AIR
SUPPLY 1 ten, END VIEW SENSOR TUBE SIDE VIE RTU ANGLE FRAME NEW EXISTING E.S.P. D.B. W.B. SENSIBLE COOLING D.B. OUTPUT @ 47 DEG, UNIT M.C.A.
SEE HVAC PLAN � SEE STRUCTURAL /
FOR DUCT 6
REMOTE TEMP SENSOR IS FACTORY DRAWINGS RTU-1 YORK 2,400 CFM 80 67 71,000 BTU 12.0 70 208/30/60Hz 50A
ROUTING. KEEP SUPPLY AIR DUCT INSTALLED AND CAN BE FOUND IN XYE07 425 CFM 55,000 BTU 67,000 BTU 34.3
MAIN TRUNK AS THE FILTER SECTION. MOUNT NEW 0.25 IN.
HIGH AS POSSIBLE. HORN STROBE UNIT BRACKET ON BOTTOM OF RETURN J-BOX AT DECK FOR RTU RTU-2 YORK 2,400 CFM 80 67 71,000 BTU 12.0 70 208/30/6OHz 50A
/ AIR DUCT CLOSE TO SUPPLY SIDE. NOTE: CONTROL WIRING FOR POWER & CONTROLS SEE XYE07 425 CFM 55,000 BTU 67,000 BTU 34.3
SENSOR TUBE LOCATION IF REQUIRED EXTEND WIRE FROM SENSOR THRU EACH RTU MUST BE RUN IN E-1 FOR CONDUIT SIZE NEW 0.25 IN.
JUNCTION BOX AND CONDUIT MOUNTED TO DECK PER NEC DUCT AND INSERT THRU TUBE AND SEPARATE CONDUIT. SEE MAKE CONNECTIONS THRU HUB PROVIDED RTU-3 YORK 2,400 CFM 80 67 71,000 BTU 12.0 70 208/30/6OHz 50A
LEAVE 1/4" STICKING BELOW SHEET E-6 FOR ADDITIONAL XYE07 425 CFM 55,000 BTU 67,000 BTU 34.3
BOTTOM OF TUBE, INFORMATION. IN BOTTOM OF THE RTU, DO NOT CUT NEW 0.25 IN.
SMOKE DETECTOR IS FACTORY MOUNTED IN THE RETURN AIR SECTION PAN TO GAIN ACCESS. ALL CONNECTIONS RTU-4 YORK 2,400 CFM 80 67 71,000 BTU 12.0 70 208/30/6OHz 50A
OF THE ROOFTOP UNIT. SEE MANUFACTURER'S SPECIFICATIONS. 18 GAUGE 4 CONDUCTOR UNSHIELDED BETWEEN INSIDE OF RTU TO BE WEATHERPROOF. XYE07 425 CFM 55,000 BTU 67,000 BTU 34.3
RTU CONTROLS AND T-STAT. 18 GAUGE 3 NEW 0.25 IN.
CONDUCTOR BETWEEN TEMP SENSOR AND RTU
WIRE MOUNTED REMOTE TEMPERATURE SENSOR PROBE INSIDE RETURN AIR DUCT, EXTEND CONTROLS. RUN ALL CABLE IN 1/2" CONDUIT. ROOFTOP UNITS SHALL HAVE ECONOMIZERS.
WIRE THROUGH SENSOR TUBE. LET WIRE HANG 1/4" BELOW BOTTOM OF TUBE.
No Scale MH102 No Scale MHS01 1/8" = 1'-0" rtu-sched
5 ROOFTOP UNIT VIEW OF RTU 16 ROOF CURB 18 ROOF TOP UNIT SCHEDULE
LC-)
(_0
O
w
Cn
J
�
Q
c�
w
0
_I
L.L
LU
O
O
M
z
O
Z
2
z
Cl)
LU
O
z
N
LU
N
Z
I-
Q
O
>
Q
dam'
LL
U
00
�
o 4
U 00
00
�
W
c'
U U
Q
y
�'
Q
,,€•�
toLn
N
71,
C'3 U
an Digitally
signed
by
Danny
Dos
y
Date:
2021.07.21
OSS-05,00
10-43-00
1
05/28/2021
57N-REMODEL