Loading...
HomeMy WebLinkAboutGENERAL INFORMATION SECTION AST. LUCIE WORKS Master Permit No. Contractors Name: Section A (General Information). Total Home Roofing Process No. License# CCC1330489 Job Address 2004 N 46th Street Fort Pierce, FI 34947 ROOF CATEGORY ®Low Slope ❑ Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles ® Asphaltic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance K,Reroofing ❑Recovering .ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) 1219 Steep Sloped Roof Area (SF) 1402 Total (SF) 2621 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ST. LUCIE WORKS I Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Certalnteed Product Approval No.: FL2533-R26 Design Wind Pressures, From RAS 128 Or Calculations: Zone 1':-34.6Zone 1: 6�one 2: Zone 3.'108.4 Max. Design Pressure, from the specific product approval system: -127.5 Deck: 1 • r t Gauge Thickness: 1 /8" Anchor/Base Sheet & No. df Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: ISOboard Base Insultation Size and Thickness: 1.5' Base Insulation Fastener/Bonding Material: Top Insulation Layer: securock Top Insulation Size and Thickness: .25' Top Insulation Fastener/Bonding Material: Flintlast w/ metal plate Base Sheet(s) & No. of Ply(s): Flintlastic Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Flintiastir. Top Ply Fastener/Bonding Material: SA Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':r.." oc @ Lap, # Rows— ® _ nc Zone 1:_" oc @ Lap, # Rows — 0 — oo Zone 2:—" oc @ Lap, # Rows — ® — ec Zone 3:—" oc @ Lap, # Rows_ ® —' oo Number of Fasteners Per Insulation Board: Zone 1':_Zone 1:one 2:_Zone 3:_ Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc... Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. FT. Parapet Flintlastic FT. Height 15' Flintlastic Securock Isoboard Wood Mean Roof Height Drip Edge: 3" X 3" GalvAlum ST. LUCIE WORKS Section D (Steep Slope Roof System) Roof System Manufacturer: Owens Corning Notice of Acceptance Number: FL10674-R16 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1:-74 one 2e: -pone 2n: 108 one 2r: 108one 3e: 108 7one 3r:-128 Deckrype: ( Wood - 7dedayrnentWeatherlock Roof V. 0 : 12 latiorc N/A Fire Barrier: N/A RidgeVenttlation?Fastener Type & Spacing: 1 114" Ring Shank Nails n/a Adhesiee Type: N/A Type Cap Sheet I N/A. MeantRooFHeight: 25' Roof Covering: I Asphalt Shingles Type & Size Drip 3" X 3" Galy Alum r-A.. -