HomeMy WebLinkAboutGENERAL INFORMATION SECTION AST. LUCIE WORKS
Master Permit No.
Contractors Name:
Section A (General Information).
Total Home Roofing
Process No.
License# CCC1330489
Job Address 2004 N 46th Street Fort Pierce, FI 34947
ROOF CATEGORY
®Low Slope ❑ Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles
® Asphaltic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
❑ New roof ❑ Repair ❑ Maintenance K,Reroofing ❑Recovering
.ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) 1219 Steep Sloped Roof Area (SF) 1402 Total (SF) 2621
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include
dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
ST. LUCIE WORKS
I
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer: Certalnteed
Product Approval No.: FL2533-R26
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1':-34.6Zone 1: 6�one 2: Zone 3.'108.4
Max. Design Pressure, from the specific product approval
system: -127.5
Deck:
1 • r t
Gauge Thickness: 1 /8"
Anchor/Base Sheet & No. df
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer: ISOboard
Base Insultation Size and Thickness: 1.5'
Base Insulation Fastener/Bonding Material:
Top Insulation Layer: securock
Top Insulation Size and Thickness: .25'
Top Insulation Fastener/Bonding Material:
Flintlast w/ metal plate
Base Sheet(s) & No. of Ply(s): Flintlastic
Base Sheet Fastener/Bonding Material:
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply: Flintiastir.
Top Ply Fastener/Bonding Material:
SA
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':r.."
oc @ Lap, # Rows—
® _ nc
Zone 1:_"
oc @ Lap, # Rows
— 0 — oo
Zone 2:—"
oc @ Lap, # Rows
— ® — ec
Zone 3:—"
oc @ Lap, # Rows_
® —' oo
Number of Fasteners Per Insulation Board:
Zone 1':_Zone 1:one 2:_Zone 3:_
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc...
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..
FT.
Parapet
Flintlastic
FT.
Height
15'
Flintlastic
Securock
Isoboard
Wood
Mean
Roof
Height
Drip Edge: 3" X 3" GalvAlum
ST. LUCIE WORKS
Section D (Steep Slope Roof System)
Roof System Manufacturer: Owens Corning
Notice of Acceptance Number:
FL10674-R16
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1:-74 one 2e: -pone 2n: 108 one 2r: 108one 3e: 108 7one 3r:-128
Deckrype: ( Wood -
7dedayrnentWeatherlock
Roof V.
0 : 12
latiorc N/A
Fire Barrier: N/A
RidgeVenttlation?Fastener Type & Spacing: 1 114" Ring Shank Nails
n/a
Adhesiee Type: N/A
Type Cap Sheet I N/A.
MeantRooFHeight: 25' Roof Covering: I Asphalt Shingles
Type & Size Drip 3" X 3" Galy Alum
r-A.. -