Loading...
HomeMy WebLinkAboutEvaluation Report; Roof Underlayments (Soprema)ENGINEER Soprema, Inc. 1640 rue Haggerty Drummondville, Quebec J2C 5P8 (819)478-2400 EVALUATE TEST NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 CONSULT Evaluation Report S18010.06.09-1120 FL2569-1122 (NON-HVHZ) Canada Date of issuance:06/15/2009 Revision 20: 04/10/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 711 Edition (2020) Florida Building Code sections noted herein. DESCRIPTION:.;.SOprema Roof Underlayments for. use.in FBC "r on-HVHZ jurisdictions_: LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEW ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 4QS K'gCa,� ter: fir• The facsimile seal appearing was authorized by Robert •��� -. • ,,+�`�'�••• � +.y Nieminen, P.E. on 04/19/2021. This does not serve as �?�+••.i•a�" an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEW ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEW ETC, LLC ROOFING COMPONENT EVALUATION: 4.1 4.2 ONEMOletc. Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Soprema Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section., 1504.3.1 1504.3.1 1507.1.1, 1507.2.4, 1507.2.9.2 / R905.1.1, R905.2.8.2 1507.3.3 / R905.3.3 TAS 110 .Pro ert Wind resistance Wind resistance Material standard Material standard Accelerated Weathering FM 4474 UL 1897 ASTM D1970 Year 2011 2015 2015 FRSA/TRI, Sixth Edition 2018 ASTM D4798 2011 Entity,,, Examination _• :. Reference'• -; Date.. ERD (TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD (TST6049) FRSA/TRI 04-12 (MS) S43530.02.14-1-R1 02/21/2014 ERD(TST6049) ASTM D1970 (QC) S44870.04.14-3 04/02/2014 ERD (TST6049) ASTM D1970 (OH) S44870.04.14-1 04/10/2014 ERD (TST6049) ASTM D1970 (MS) S44870.04.14-4 04/10/2014 ERD (TST6049) ASTM D1970 (OH) S40540.10.14 10/31/2014 ERD (TST6049) Tensile Adhesion /.Long Term Aging SOPC-SC7645.02.15 02/13/2015 ERD (TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015 ERD (TST6049) Wind Resistance SOPC-SC14045.05.17-RI 06/07/2017 MEMO (TST6049) ASTM D1970 / TAS 110 (QC) SOPC-SC8970.08.15-R1 04/25/2018 MEMO (TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018 NEMO (TST6049) Tile Slippage 4S-SOPC-18-002.09.18 09/21/2018 NEMO (TST6049) ASTM D4798/D1970 (OH & MS) 4S-SOPC-18-002.05.19.A 05/31/2019 NEMO (TST6049) Tensile Adhesion / Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020 NEMO (TST6049) Peel adhesion (existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020 NEMO (TST6049) Peel adhesion (existing underlayments) 4j-SOPC-20-SSUDL-01.A 01/07/2021 NEMO (TST6049) ASTM D1970 (MS) 4j-SOPC-2I-SSUDL-01.A 04/19/2021 PRI (TST5878) ASTM D1970 (MS) SOP-064-02-01 12/03/2013 Soprema, Inc. (PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL, LLC (QUA9625) Quality Control MLA File No. R16814 12/10/2015 UL, LLC (QUA9625) Quality Control MLA File No. R27605 05/08/2019 UL, LLC (QUA9625) Quality Control Service Confirmation 06/29/2020 UL, LLC (QUA9625) Quality Control Florida BCIS Current PRODUCTDESCRIPTION: Product :. Material . . Plant(s) Description ,Standard LASTOBOND TU HT ASTM D1970 and Gulfport, MS self -adhering, non -woven polyester fabric FRSA/TRI 09-18 surfaced, SBS modified bitumen roof underlayment Tri-Built S/A HT TU ASTM D1970 and Gulfport, MS self -adhering, non -woven polyester fabric Underlayment FRSA/TRI 09-18 surfaced, SBS modified bitumen roof underlayment NEMO ETC, LLC Evaluation Report S18010.06.09-R20 Certiftate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R22 (NON-HVHZ) Soprema Roof Underlayments Revision 20: 04/19/2021 Page 2 of 8 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 ED 4.12 4.13 4.14 4.15 4.16 4.17 ONEMOjetc. Mater)al Product •' Plants) Descr.iptlon Standard LASTOBOND Shield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch RESISTO SA SMOOTH PLY ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS 40 modified bitumen roof underlayment LASTOBOND Shield HT ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment LASTOBOND Pro HT-N ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch LASTOBOND Pro HT-S ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment EnviroShield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment LASTOBOND Eco ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment LASTOBOND Smooth ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film - Seal HT Wadsworth, OH surfaced, SBS modified bitumen roof underlayment Tri-Built Smooth HT S/A ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film- Underlayment Wadsworth, OH surfaced, SBS modified bitumen roof underlayment PrimeSource Grip -Rite ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film - Smooth Seal HT Wadsworth, OH surfaced, SBS modified bitumen roof underlayment RESISTO LB1236 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment TRI-BUILT Sand-R SA ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - Shingle Underiayment Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment PrimeSource Grip -Rite ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand- Eave & Valley Protector Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment SRS TopShield ICE & ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - WATER DEFENDER Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment RESISTO LB1244 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment NEMO ETC, LLC Evaluation Report S18010.06.09-1120 Certficate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION F1.2569-1122 (NON-HVHZ) Soprema Roof Underlayments Revision 20: 04/19/2021 Page 3 of 8 ONEMOletc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements, and limitations concerning the use of foam plastic insulation. 5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1 ROOE COVER OPTIONS FBCSection. , I5071 : ; „1", 3507.3; i 1507.4 & 1 " 5075 150Z7 1507:8&Q507.91' ..' 'Asphalt Clay and Concrete Tile'; Metal Slate or Wood ` Underlayment Shmglesj Mechanical -Adhesive°: Panels Shingles , Slate Type Shakes or S hmgies Attach- Set .Shingles LASTOBOND TU HT, Tri-Built S/A HT TU Yes Yes Yes Yes Yes Yes Yes (Joint strips, 1507.LL3/ Underlayment Y See 5.6.1 R905.1.1.3) LASTOBOND Shield, Pro HT-N, RESISfO Yes No No Yes Yes Yes Yes paint strips,1507.1.L3/ SA SMOOTH PLY40 R905.1.1.3) Yes . LASTOBOND Shield HT, Pro HT-5 Yes No No Yes Yes Yes point strips, 1507.1.L3/ R905.1.1.3) Yes EnviroShield Yes No No Yes Yes Yes paint strips, 15o7.1.1.3/ R905.1.1.3) LASTOBOND ECO, RESISTO LB1236, TRI- BUILT Sand-R SA Shingle Underlayment, Yes Grip -Rite Eave & Valley Protector, Yes No No No No Yes (Joint strips, 1507.LL3/ TopShield ICE & WATER DEFENDER, 11905.1.1.3) RESISTO LB1244 LASTOBOND SmooW Seal HT, Tri-Built Yes Smooth HTS/A Underlayment, Grip -Rite Yes No No Yes Yes Yes point strips, 1507.LL3/ Smooth Seal HT R905.1.1.3) 5.6.1 Adhesive -set tile is limited to use of the following Approved underlayment / tile -adhesive combinations. :TABLE'1'A: ALLOWABLE TILE"ADHESIVE UNDERLAYMENT'COMBINATIONS1' Underlayment Adhes'iGe " Florida:Product-Approval LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment Dupont `Tile Boncl ' Roof Tile Adhesive" FL22525 ICP Adhesives and Sealants "Polyset® AH-160" FL6332 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report S18010.06.09-R20 Certlflcate of Authorization k31455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL2S69-R22 (NON-HVHZ) Soprema Roof Underlayments Revision 20: 04/19/2022 Page 4 of 8 NNEMOjetc. 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS' . Substrates (designed to meet wind loads for'project).' Underlayment' Application Type Primer . Material(s) LASTOBOND Shield, LASTOBOND Pro HT- (Optional) ASTM plywood, OSB or Southern Yellow N, RESISTO SA SMOOTH PLY 40, Deck / D41, Elastocol Stick, Pine (SYP) LASTOBOND Shield HT, LASTOBOND Pro sheathing Elastocol Stick Zero ASTM D41 structural concrete HT-S, EnviroShield, LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, (Optional) Elastocol Dens Deck Prime or SECUROCK LASTOBOND ECO, RESISTO LB1236, TRI- self- Insulation Stick Zero Gypsum -Fiber Roof Board BUILT Sand-R SA Shingle Underlayment, adhering Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER, RESISTO LB1244, LASTOBOND Smooth Base Sheet (Optional) Elastocol ASTM D226, Type II felt or Seal HT, Tri-Built Smooth HT S/A Stick Zero Modified Sopra-G Underlayment or Grip -Rite Smooth Seal HT LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, RESISTO LB1236, TRI- self- Existing RESISTO EXTERIOR Existing sand -surfaced, glass -fiber BUILT Sand-R SA Shingle Underlayment, adhering substrate PRIMER surfaced, mineral -surfaced or film - Grip -Rite Eave & Valley Protector or surfaced roof underlayment TopShield ICE & WATER DEFENDER " Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support. 5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. 5.7.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under the roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached base sheets - not less than Section 5.8.3 herein. 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. NEMO ETC, LLC Evaluation Report S18010.06.09-1120 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R22 (NON-HVHZ) Soprema Roof Underlayments Revision 20: 04/19/2021 Page 5 of 8 ONEMOletc. #1 Maximum Design Pressure _= -45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.. #2 Maximum Design Pressure = -67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol Stick Zero Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.. #3 Maximum Design Pressure = -120.0 psf_: Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) RESISTO EXTERIOR PRIMER Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered. Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1'/a" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.. #4 Maximum Design Pressure = -150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer; (Optional) RESISTO EXTERIOR PRIMER Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga, x 1W ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.. #5 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of -45 psf. 5.8.3.2 Mechanically -Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. #6 Maximum Design Pressure = -60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6- inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet. Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x N" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. 5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment attachment shall be in accordance with the manufacturer's installation instructions and attachment of the insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product Approval. NEMO ETC, LLC Evaluation Report S18010.06.09-1120 Certificate ojAuthorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R22 (NON-HVHZ) Soprema Roof Underlayments Revision 20: 04/19/2021 Page 6 of 8 ONEMOletc. 5.9 Exposure Limitations: TABLE`S EXPOSURE LIMITATIONS•:, Prepared;Roof Cover Maximum ;. Underlayment _ Installation Type'. Exposure (days)' ; LASTOBOND Eco, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle, Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO Mechanically attached 30 LB1244 LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND Smooth Mechanically attached 90 Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip -Rite Smooth Seal HT Mechanically attached or LASTOBOND TU HT or Tri-Built S/A HT TU Underlayment adhesive -set tile roof 180 system 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4:' TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS - Underlayment :Tile Profile Staging Method Maximum`Slope' Flat Max. 10-tile stack 6:12 Lugged Max.10-tile stack 5:12 Double -tile stacking method, as shown below 6:12 LASTOBOND TU HT, Tri- Built S/A HT TU Underlayment Lugged ,a 6. INSTALLATION: 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.2.1 Installation of RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayment in a reroof (tear -off) application atop an existing underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering Underlayments, contact RESISTO technical support. NEMO ETC, LLC Evaluation Report S18010.06.09-1120 Certftate ofAutharization#32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-RZ2 (NON-HVHZ) Soprema Roof Underlayments Revision 20. 04/19/2021 Page 7 of 9 '(NNEMO I etc. 6 3 LASTOBOND TU-HT, Tri-Built S/A-HT TU Underlayment, LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTOSA SMOOTH PLY 40,_LASTOBOND Shield HT,'LAS.OBOND Pro HT-S,.EnviroShieldi LASTOBOND Eco, LASTOBOND, Smooth Seal HT, Tri-Built Smooth HT S/A Underlaymenf, Grip .Rite Smooth Seal HT, RESISTO L81236, TRI-BUILT Sand -RSA Shingle Lind erlayment, Grip -Rite Eave & Valley Protector, TopShield ICE& -WATER DEFENDER or, RESISTO L81244: 6.3.1 Non -Tile Applications: Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.3.2 Tile Applications: Limited to LASTOBOND TU HT or Tri-Built S/A HT TU Underlayment. Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. REQUIREMENTS:7. BUILDING PERMIT As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. S. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. QUALITY9. UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report S18010.06.09-R20 Certiftate ajAuthorizadon #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R22 (NON-HVHZ) Soprema Roof Underlayments Revision 20: 04/19/2021 Page 8 of 8