Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SLC Roofing Permit Information
C�. % LUCIE WOKS REVIEWED FOR CODE COMPLIANCE ST LUCIE COUNTY ROOFING PERMIT INFOUVEMOWCOUNTY MCC Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building File C©pv INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6;7 - Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 Metal Roofs A, B, D Wood Shingles and Shakes A, B, D 1,2,4,5,6,7 Other As Applicable 102,3,4,6,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 12.8 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC Section A (General Information) Master Permit No. Process No. File Copy Contractors Name: Roof Doctors LLC License # CCC1326620 Job Address 5302 E Seminole Rd ROOF CATEGORY 0 Low Slope 0 Mechanically Fastened Tile 0 Mortar/Adhesive Set Tiles DAsphaltic Shingles X Metal Panel/Shingles Mood Shingles/Shakes 13 Prescriptive BUR-RAS 150 ROOF ROOF TYPE. 0 New roof 0 Repair 0 Maintenance P"'Reroofing 0 Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) 3560 Total (SF) 3560 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Page #2: Edge Identification 5302 Seminole Rd Fort Pierce FL 34951 USA Edge Type Length(Ft.) Eave 222.78 Rake 97.33 Hip 80.78 Valley 105.56 Ridge 115.32 StepFlashing 9.20 ApronFlashing 18.62 SlopeTransition 0.00 Pitch = `Area(Sq:'Ft.)= 6/12 3560 .Total . 3560. z; LUCIE WORKS NA Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 Or Calculations: Zone V-. Zone 1: Zone 2: Zone 3: Max. Design Pressure, from the specific product approval system: Deck: Type: Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':_.._." oc @ Lap, # Rows ® "oc Zone 1:—" oc @ Lap, # Rows ® "ac Zone 2:_.._." oc @ Lap, # Rows @ � ac Zone 3:_.._." oc @ Lap, # Rows_ 1 ° oc Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterf lashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. i Section D (Steep Slope Roof System) Roof System Manufacturer: Metal Alliance Inc Notice of Acceptance Number: FL31652-RI (31652.1) REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY B®CC Afle Copy Minimum Design Wind Pressures, If Applicable (From] or Calculations): .Zone 1� 1�one 2e�117 7L§ne 2n:_�one 2r -117 a 3e: 117•?o`'he 3r: -117.75 Method A --117.75 Roof Slope: 6 : 12 Ridge Ventilation? na Deck Type: Wood \ Type Underlayment: Soprema Tribuilt Smooth self adheredFL2569-R22 Mean Roof Height: 10 Insulation: na Fire Barrier: na Fastener Type &Spacing: Self -Adhered Adhesive Type: na Type Cap Sheet: na Roof Covering: 5V Crimp Type &Size Drip. 26 ga Edge: Section E (Tile Calculations) For Moment based the systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mr. If the Mf values are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable. Method 1 'Moment Based Tile Calculations Per RAS 12T (Zone 1: x = (Zone 2e: x (Zone 2n: x ]L (Zone 2r: x _ (Zone 3e: x )L (Zone 3r: x 1 - M9: = Mn -a - M9: =.Ma„ -M9: =Mrs Product Approval Mi..- Product Approval Mf-- Product Approval Mf.-- Product Approval Mf Product Approval Mr Product Approval Mf Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mf Mr required Moment Resistance* Mean Roof Height Roof Slope 15, 20' 25' 30, 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment based tile systems • For Uplift based the systems use Method 3. Compare the values for F' with the values for Fr If the F' values are greater than or equal to the Fr values, for each area of the roof, then the the attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T (Zone 1: x L =x W:= ) -W: cos r =Fri (Zone 2e: x L =x W:= ) -W: cos r =Fr2e (Zone 2n: x L =x W:= ) -W: cos r =Fr2n (Zone 2r: x L =x W:= ) -W: cos r =Fr2r (Zone 3e: x L =x W:= ) -W: cos r =Fr3e (Zone 3r: x L =x W:= ) -W: cos r =Fr3r Product Approval F' Product Approval F' Product Approval F' Product Approval F' Product Approval F' Product Approval F' Where to Obtain Information Description Symbol Where to find Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope a Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions I L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application.