HomeMy WebLinkAboutGENERAL INFORMATION SECTION AST. LUCIE WORKS
Section A (General Information).
Master Permit No. Process No.
Contractors Name: Total Horne Roofing License # CCC1330489
Job Address 1691 Timberlake Drive Fort Pierce, FI 34947
ROOF CATEGORY
❑ Low slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles
R Asphaltic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes
❑ New roof ❑ Repair
Low Slope Roof Area (SF) 0
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
❑ Maintenance [Reroofing
ROOF SYSTEM INFORMATION
Steep Sloped Roof Area (SF) 4415
❑ Recovering
Total (SF) 4415
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include
dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
ST. LUCIE WORKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer: Certainteed
Product Approval No.: FL2533-R26
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1':-34.6Zone 1'66.3Zone 2: Zone 3:-148.4
Max. Design Pressure, from the specific product approval
system: -127.5
Deck:
Type: Wood
Gauge Thickness: 1 /811
Slope:
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s):
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':—"
oc @ Lap, # Rows
@ ° oo '
Zone 1:—"
oc @ Lap, # Rows
@ woe
Zone 2:_._
" oc @ Lap, # Rows
@ 000
Zone 3:—"
oc @ Lap, ## Rows
® Soo '
Number of Fasteners Per Insulation Board:
Zone 1': Zone 1: Zone 2: Zone 3:
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc...
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16.,
Flintlastic
Flintlastic
Base Sheet Fastener/Bonding Material: Drip Edge: 3" X 3" G�
_ SA
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply: Flintlastic
Top Ply Fastener/Bonding Material:
SA
ST. LUCIE WORKS
Section D (Steep Slope Roof System)
Roof System Manufacturer: Owens Cornln
Notice of Acceptance Number:
FL10674-R 16
Minimum Design Wind Pressures, if Applicable (From RAS 127 or Calculations):
Zone 1:-done 2e:-:7�4one 2n- 108 one 2r-bone 3e: 1�one 3r:-128
Deck Type: Wood
Roof 5bpe: Type Underiayment Weatherlock
5 : 12
Insulation: I NIA
Fire Barrier: INIA
RidgeVentillalon? Fastener Type &Spacing: 1 1/4" Ring Shank Nails
nla
Adhesive Type: NIA
Type Cap Sheet: NIA
Mean RoofHeight: 25 Roof Covering: I Asphalt Shingles
Type & Size Drip 3" X 3" Galy Alum
Edge: