Loading...
HomeMy WebLinkAboutGENERAL INFORMATION SECTION AST. LUCIE WORKS Section A (General Information). Master Permit No. Process No. Contractors Name: Total Horne Roofing License # CCC1330489 Job Address 1691 Timberlake Drive Fort Pierce, FI 34947 ROOF CATEGORY ❑ Low slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles R Asphaltic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ New roof ❑ Repair Low Slope Roof Area (SF) 0 ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ Maintenance [Reroofing ROOF SYSTEM INFORMATION Steep Sloped Roof Area (SF) 4415 ❑ Recovering Total (SF) 4415 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ST. LUCIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Certainteed Product Approval No.: FL2533-R26 Design Wind Pressures, From RAS 128 Or Calculations: Zone 1':-34.6Zone 1'66.3Zone 2: Zone 3:-148.4 Max. Design Pressure, from the specific product approval system: -127.5 Deck: Type: Wood Gauge Thickness: 1 /811 Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':—" oc @ Lap, # Rows @ ° oo ' Zone 1:—" oc @ Lap, # Rows @ woe Zone 2:_._ " oc @ Lap, # Rows @ 000 Zone 3:—" oc @ Lap, ## Rows ® Soo ' Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc... Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16., Flintlastic Flintlastic Base Sheet Fastener/Bonding Material: Drip Edge: 3" X 3" G� _ SA Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Flintlastic Top Ply Fastener/Bonding Material: SA ST. LUCIE WORKS Section D (Steep Slope Roof System) Roof System Manufacturer: Owens Cornln Notice of Acceptance Number: FL10674-R 16 Minimum Design Wind Pressures, if Applicable (From RAS 127 or Calculations): Zone 1:-done 2e:-:7�4one 2n- 108 one 2r-bone 3e: 1�one 3r:-128 Deck Type: Wood Roof 5bpe: Type Underiayment Weatherlock 5 : 12 Insulation: I NIA Fire Barrier: INIA RidgeVentillalon? Fastener Type &Spacing: 1 1/4" Ring Shank Nails nla Adhesive Type: NIA Type Cap Sheet: NIA Mean RoofHeight: 25 Roof Covering: I Asphalt Shingles Type & Size Drip 3" X 3" Galy Alum Edge: