Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL5/11/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquFsbTbi%2b3jRW%2fj1INxILro6J%2bwW2YM8XdDRYd%2fkWVL1w%3d%3d 1/3 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL13300-R9 Application Type Revision Code Version 2020 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Velux America, LLC Address/Phone/Email P.O. Box 5001 Greenwood, SC 29648 (864) 377-0691 Mike.rhoden@velux.com Authorized Signature Mike Rhoden Mike.rhoden@velux.com Technical Representative Mike Rhoden Address/Phone/Email 104 Ben Casey Dr Fort Mill, SC 29708 (864) 377-0691 mike.rhoden@velux.com Quality Assurance Representative Mike Rhoden Address/Phone/Email 104 Ben Casey Drive Fort Mill, SC 29708 (803) 396-5736 mike.rhoden@velux.com Category Sky Lights Subcategory Skylight Compliance Method Certification Mark or Listing Certification Agency Window and Door Manufacturer Association Validated By Window and Door Manufacturers Association Referenced Standard and Year (of Standard)Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2017 ASTM E 1886 2013 ASTM E 1996 2014 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL13300_R9_Equiv_FL 13300 ASTM EQ.pdf 5/11/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquFsbTbi%2b3jRW%2fj1INxILro6J%2bwW2YM8XdDRYd%2fkWVL1w%3d%3d 2/3 Product Approval Method Method 1 Option A Date Submitted 04/27/2021 Date Validated 05/03/2021 Date Pending FBC Approval Date Approved 05/06/2021 Summary of Products FL #Model, Number or Name Description 13300.1 QPF [2004 or 2008 or 2014 or 2089]Pan Flashed Fixed Skylight, size 4646 and smaller Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +160/-60 Other: SKG-PG60, max. size 1219mm x 1219mm. PG60 means minimum capacity is 60 psf. Glass meets ASTM E1300: 3mm clear tempered with Lo-E366 (or Lo-E340 for 2014 variant) on surface 2 / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm heat-strengthened panes and 0.030" PVB interlayer (with white coating for 2008 variant; with second Lo- E coating on surface 4 for 2089 variant). For anchorage details, see installation instructions. Certification Agency Certificate FL13300_R9_C_CAC_FL 13300 QPF [4646 or smaller] 04-08- 14-89_non-impact.pdf Quality Assurance Contract Expiration Date 01/13/2031 Installation Instructions FL13300_R9_II_QPF installation instructions_07.09.2020_452199-2020-06_L.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 13300.2 QPF [2005 or 2015 or 2088]Pan Flashed Fixed Skylight, size 4646 and smaller Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +160/-60 Other: SKG-PG60, max. size 1219mm x 1219mm. PG60 means minimum capacity is 60 psf. Glass meets ASTM E1300: 3mm clear tempered with Lo-E366 (or Lo-E340 for 2015 variant) on surface 2 / 10.5mm st. stl. spacer / 3mm clear tempered (with second Lo-E coating on surface 4 for 2088 variant). For anchorage details, see installation instructions. Certification Agency Certificate FL13300_R9_C_CAC_FL 13300 QPF [4646 or smaller] 05-15- 88_non-impact.pdf Quality Assurance Contract Expiration Date 01/13/2031 Installation Instructions FL13300_R9_II_QPF installation instructions_07.09.2020_452199-2020-06_L.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 13300.3 QPF [2006 or 2016]Pan Flashed Fixed Skylight, size 4646 and smaller Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Wind Zone 4, Missile Level D, Cycle Pressure +50/-50, max. size 1219mm x 1219mm. This model was tested for cycling pursuant to ASTM standards. Glass meets ASTM E1300: 3mm clear tempered with Lo-E366 (or Lo-E340 for 2016 variant) on surface 2 / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. For anchorage details, see Page 6 of instructions. Certification Agency Certificate FL13300_R9_C_CAC_FL13300 R8 QPF [4646 or smaller] 0006 or 0016 Impact.pdf Quality Assurance Contract Expiration Date 11/18/2030 Installation Instructions FL13300_R9_II_QPF installation instructions_07.09.2020_452199-2020-06_L.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 5/11/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquFsbTbi%2b3jRW%2fj1INxILro6J%2bwW2YM8XdDRYd%2fkWVL1w%3d%3d 3/3