HomeMy WebLinkAboutAPPROVED ENERGY LOT 30(1)FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Fiorida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KHOV-EDEN
Builder Name: KHOVNANAIN HOMES
Street: 5105 ARMINA PLACE
Permit Office:
City, State, Zip. FT PIERCE, FL,
Permit Number:
Owner: EDEN MODEL LOT 30
@ WATERSTONE
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
10. Wall Type$1796.7 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Biock - Int Insul, Exterior
R=4.1 1516.70 ft2
b. Frame - Wood, Adjacent
R=11.0 280.00 ft2
3. Number of units, if multiple family
t
c NIA
R= ft2
4. Number of Bedrooms
4
d. NIA
R= ft2
5- Is this a worst case?
No
11. Ceiling Types (1618.0 sqft,)
Insulation Area
a. Under Attic (Vented)
R=30.0 1618.00 ft2
6. Conditioned floor area above grade (ft2)
1616
b. NIA
R= ft2
Conditioned floor area below grade (ft2)
0
c. NIA
R= ft2
7. Windows(154.9 sqft.) Description
Area
12. Ducts
R ft2
a. Sup: Attic, Ret: HALL BATH, AH: HALL
BATH 6 300
a. U-Factor: Dbl, U=0.28
113.92 ft2
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.55
41.00 ft2
13. Cooiing systems
kBtulhr Efficiency
SHGC: SHGC=0.34
a. Central Unit
29.4 SEERA&00
c. U-Factor: NIA
ft2
SHGC:
Area Weighted Average Overhang Depth:
4,909 ft.
14. Heating systems
kBtulhr Efficiency
Area Weighted Average SHGC:
0.311
a. Electric Strip Heat
23.0 COP:1.00
8. Skylights
Area
c. U-Factor:(AVG) N/A
ft2
15. Hot water systems
SHGC(AVG): NIA
a. Electric
Cap: 40 gallons
9. Floor Types (1616.0 sqft.)
Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation
R=0.0 1616.00 ft2
b. Conservation features
b. NIA
R= ft2
None
c. NIA
R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.096
Total Proposed Modified Loads: 54.01
PASS
Total Baseline Loads: 55.24
1 hereby certify that the plans and spe
'fications covered by
Review of the plans and
114E
this calculation are in compliance witqte
Florida Energy
specifications covered by this
4V
Code.
calculation indicates compliance
,,,,�''T = ` 1 �x+
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
-'-
{
DATE:
this building will be inspected for
compliance with Section 553.908
Cc ::.
I�
* , M,
r
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
QWE~-
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
7/13/2021 9:14 AM a EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: KHOV-EDEN Bedrooms: 4
Address Type:
Street Address
Building Type: User Conditioned Area: 1616
Lot #
Owner Name: EDEN MODEL LOT 30 @ W Total Stories: 1
BlocklSubdivision:
# of Units: 1 Worst Case: No
PlatBook:
Builder Name: KHOVNANAIN HOMES Rotate Angle: 0
Street:
5105 ARM INA PLACE
Permit Office: Cross Ventilation: No
County:
St. Lucie
Jurisdiction: Whole House Fan: No
City, State, Zip:
FT PIERCE,
Family Type: Detached
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/ Design Temp
lnt Design Temp Heating
Design Daily Temp
Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name. Area Volume
1 Entire House 1616 14220.8
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 BED 3 161 1416.8 No 1
4
1 No
Yes
Yes
2 HALL BATH 77 678 No 0
1 No
Yes
Yes
3 FOYER 172 1514 No 0
1 No
Yes
Yes
4 BED 4 149 1307 No 1
1 No
Yes
Yes
5 LAUNDRY 52 458 No 0
1 No
Yes
Yes
6 BED 2 149 1307 No 1
1 No
Yes
Yes
7 GRT DIN KITCHEN 550 4840 No 0
1 No
Yes
Yes
8 MASTER SUITE 176 1544 No 2
1 No
Yes
Yes
9 MAST WIC 58 506 No 0
1 No
Yes
Yes
10 M BATH 72 634 No 0
1 No
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BED 3 38 ft 0
163 ft2
----
0 1
0
2 Slab -On -Grade Edge lnsulatio HALL BATH 11 ft 0
77 ft2
----
1 0
0
3SIab-On-Grade Edge lnsulatio FOYER 25 ft 0
172 ft2
----
1 0
0
4SIab-On-Grade Edge lnsulatio BED 4 14 ft 0
14&5 ft2
----
0 1
0
5SIab-On-Grade Edge lnsulatio LAUNDRY 1 ft 0
52 ft2
----
1 0
0
6SIab-On-Grade Edge lnsulatio BED 2 13.5 ft 0
148.5 ft2
----
0 1
0
7SIab-On-Grade Edge lnsulatio GIRT DIN KITCHE 49 ft 0
550 ft2
----
0.5 0.5
0
7/13/2021 9:14 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
8 Slab -On -Grade Edge Insulatio MASTER SUITE 26.5 ft 0
175.5 ft2
----
0 1 0
9 Slab -On -Grade Edge Insulatio MAST WIC 11.5 ft 0
57.5 ft2
--_-
0 1 0
10SIab-On-Grade Edge Insulatio M BATH 1 ft 0
72 ft2
-__-
1 0 0
ROOF
/ Roof Gable Roof
Rad
Solar SA Emitt
Emitt Deck Pitch
1/ # Type Materials Area Area Color
Barr
Absor. Tested
Tested Insul. (deg)
1 Hip Composition shingles 1750 ft2 0 ft2 Medium
N
0.9 No 0.9
No 0 22.6
ATTIC
V
#
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
1
Full attic
Vented
150
1616 ft2
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
1
Under Attic (Vented)
BED 3
30
Blown
163 ft2
2
Under Attic (Vented)
HALL BATH
30
Blown
77 ft2
3
Under Attip (Vented)
FOYER
30
Blown
172 ft2
4
Under Attic (Vented)
BED 4
30
Blown
149 ft2
5
Under Attic (Vented)
LAUNDRY
30
Blown
52 ft2
6
Under Attic (Vented)
BED 2
30
Blown
149 ft2
7
Under Attic (Vented)
GIRT DIN KITCHE
30
Blown
550 ft2
8
Under Attic (Vented)
MASTER SUITE 30
Blown
176 ft2
9
Under Attic (Vented)
MAST WIC
30
Blown
58 ft2
10
Under Attic (Vented)
M BATH
30
Blown
72 ft2
WALLS
Adjacent
Space
Gavity Width
Height
1
NE
Exterior Concrete Block
- Int Insul BEDS
4.1 13
1 9
4
122.1 ft2
2
SE
Exterior Concrete Block
- Int Insul BEDS
4.1 10
8 9
4
99.6 ft2
3
SW
Exterior Concrete Block
- Int Insul, BED 3
4.1 12
2 10
0
121.7 ft2
4
SW
Exterior Concrete Block
- Int InsLHiALL BATH
4.1 9
11 10
0
99.2 ft2
5
SE
Exterior Concrete Block
- Int Insui FOYER
4.1 4
10 9
4
45.1 ft2
6
SW
Exterior Concrete Block
- Int Insul BED 4
4.1 12
7 10
0
125.8 ft2
7
NE
Exterior Concrete Block
- Int Insul BED 2
4.1 13
1 9
4
122.1 ft2
8
SW
Exterior Concrete Block
- Int lnsGRT DIN KIT
4.1 22
6 10
0
225.0 ft2
9
NW
Exterior Concrete Block
- Int InsGRT DIN KIT
4.1 23
3 9
4
217.0 ft2
10
NE
Exterior Concrete Block
- Int InSMASTER SUI
4.1 12
7 9
4
117.4 ft2
11
NW
Exterior Concrete Block
- Int InsMASTER SUI
4.1 12
7 9
4
117.4 ft2
12
NE
Exterior Concrete Block
- Int InsuMAST WIC
4.1 11
2 9
4
104.2 ft2
IRCC
N
Framing Frac Truss Ty
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
Sheathing Framing
RAInhie Fractinn
Solar
Absor.-Gr�4e°.
Below
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
❑
7/13/2021 9:14 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space Cavity Width Height
Ft In Ft InArea
Sheathing Framing Solar Below
_ q
13 NW
Garage Frame - Wood GRT DIN KIT 11 30 0 9 4 280.0 ft2
0 0 05
0
DOORS
#
Ornt
Door Type Space Storms U-Value
Width Height
Area
Ft
In Ft In
1
NW
Insulates! GRT DIN KIT None .46 3
8
24 ft2
2
NW
Wood GRT DIN KIT None .46 2.8 8
22.4 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V/ #
Omt ID Frame
Panes NFRC U-Factor SHGC Imp Area Depth
Separation Int Shade
Screening
1
SE 2 Metal
Double (Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft 0 in
1 ft 0 in None
None
2
SW 6 Metal
Double (Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft 0 in
1 ft 0 in None
None
3
NE 7 Metal
Double (Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft 0 in
1 ft 0 in None
None
4
SW 8 Metal
Double (Tinted) Yes 0.55 0.34 N 41.0 ft2 11 ft 0 in
1 ft 0 in None
None
5
NW 9 Metal
Double (Tinted) Yes 0.28 0.3 N 23.0 ft2 1 ft 0 in
1 ft 0 in None
None
6
NW 9 Metal
Double (Tinted) Yes 0.28 0.3 N 23.0 ft2 9 ft 6 in
1 ft 0 in None
None
7
NW 11 Metal
Double (Tinted) Yes 0.28 0.3 N 22.9 ft2 1 ft 0 in
1 ft 0 in None
None
GARAGE
#
Floor Area
Ceiling Area Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
380 ft2
380 ft2 64 ft 8 ft
1
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000391 1557.2 90.92 170.69 .1312
7
HEATING SYSTEM
#
System Type
Subtype Speed Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/ None COPA 23 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split Singl SEER: 16 29.4 kBtuthr
ctm 0.71 1
sys#1
7/13/2021 9:14 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPI IT SI IMMARY rW1=rr1[I ICT 011=113nOT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.95
40 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System
Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
` ---- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
�/ # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT ON RLF
Heat Cool
1 Attic
6 300 ff2
HALL BATH 1 ft2
Default Leakage
HALL SAT
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolin Jan Feb
Heating �X Jan HFeb
Mar
Mar
�xl
Apr
Apr
Ma
May
X Jun X Jul
Jun Jul
Au
X Augri
Se
Sep
Oct Nov
f j Oct ]CNovX
Dec
DecVentin
[[[ Jan Feb
X Mar
Apr
[
May
[ Jun Jul
Aug
Se
[X Oct [X] Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10 11
12
Cooling (WD) AM
78
78
78
78
78 78
78
78
80 80 80
80
PM
80
80
78
78
78 78
78
78
78 78 78
78
Cooling (WEH) AM
78
78
76
78
78 78
78
78
78 78 78
78
PM
78
78
78
78
78 78
78
78
78 78 78
78
Heating (WD) AM
66
66
66
66
66 68
68
68
68 68 68
68
PM
68
68
68
68
68 68
68
68
68 68 66
66
Heating (WEH) AM
66
66
66
66
66 68
68
68
68 68 68
68
PM
68
68
68
68
68 68
68
68
68 68 66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibslsq.ft.
0 ft2
0 ft
0.3
BED 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC BED 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN DINING
Default(8 Ibs/sq.ft.
ft2
ft
0.3
GREAT ROOM
Default(8 Ibslsq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibslsq.ft.
ft2
ft
0.3
M WIC
Default(8 Ibs/sq.ft
ft2
ft
0.3
M TIOLET
Default(8 Ibslsq.ft.
ft2
ft
0.3
M BATH
Default(8 lbs/s .ft.
ft2
ft
0.3
MASTER SUITE
7/13/2021 9:14 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftZ)
7. Windows" Description
a. U-Factor: Dbl, U=0.28
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.34
c. U-Factor: NIA
SHGC:
d. U-Factor: NIA
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): NIA
SHGC(AVG): NIA
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. NIA
c. NIA
5105 ARMINA PLACE, FT PIERCE, FL,
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1516.70 ft2
b. Frame - Wood, Adjacent
R=11.0
280.00 ft2
1
c. NIA
R=
ft2
4
d. NIA
R=
ft2
11. Ceiling Type and insulation level
Insulation
Area
No
a. Under Attic (Vented)
R=30.0
1618.00 ftx
1616
b. NIA
R=
ft2
Area
c. NIA
R=
ft2
113.92 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: HALL BATH, AH: HALL BATH
6 300
41.00 ft2
13, Cooling systems
kBtulhr
Efficiency
ft2
a. Central Unit
29.4
SEER:16.00
ft�
4.909 ft.
0.311
Area
ft2
Insulation Area
R=0.0 1616.00 ft2
R= ft2
R= ft2
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
kBtulhr Efficiency
23.0 COP:1.00
Cap: 40 gallons
EF: 0.95
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/13/2021 9:14 AM EnergyGaugeO USA 7.0.00 - F12Res2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1