Loading...
HomeMy WebLinkAboutAPPROVED, ENERGY LOT 28(1)FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KHOV-EDEN Builder Name: KHOVNANAIN HOMES Street: 5114 ARMINA PLACE Permit Office: City, State, Zip: FT PIERCE, FL, Permit Number: Owner: EDEN MODEL LOT 28 @ WATERSTONE Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 } 1. New construction or existing New (From Plans) 10. Wall Type�1796.7 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1516.70 ftx 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 280.00 ft2 c NIA R= ft2 4. Number of Bedrooms 4 d. NIA R= ft2 5. Is this a worst case? No 11. Ceiling Types (1618.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1618.00 ft2 6. Conditioned floor area above grade (ft2) 1616 b. NIA R= {f2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 7. Windows(154.9 sqft.) Description Area 12aDucts R ft2 a. U-Factor: Dbl, U=0.28 113.92 ft2 SupAttic, Ret: HALL BATH, AH: HALL BATH 6 300 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=0.55 41.00 ft2 13. Cooiing systems kBtulhr Efficiency SHGC: SHGC=0.34 a. Central Unit 29.4 SEER:16.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 4_909 ft. 14. Heating systems k6tulhr Efficiency Area Weighted Average SHGC: 0.311 a. Electric Strip Heat 23.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA a. Electric Cap: 40 gallons 9. Floor Types (1616.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1616.00 ft2 b. Conservation features b. NIA R= ft2 None c. NIA R= ft2 16. Credits Pstat GlasslFloor Area: 0.096 Total Proposed Modified Loads: 54.01 PASS A Total Baseline Loads: 55.24 I hereby certify that the plans and sp overed by Review of the plans and 1cf1 Sr41J, this calculation are in compliance wit nergy specifications covered by this ti Code. calculation indicates compliance k with the Florida Energy Code. r,,,,,t-•,: ;,;:�*a;',.a`'„ p PREPARED BY: Before construction is completed W'� DATE: this building will be inspected for r compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance -: Florida Statutes.,r� with the Florida Energy Code. C'QD WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 7/1312021 9:15 AM EncrgyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: KHOV-EDEN Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1616 Lot # Owner Name: EDEN MODEL LOT 28 @ W Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: KHOVNANAIN HOMES Rotate Angle: 0 Street: 5114 ARM INA PLACE Permit Office: Cross Ventilation; No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1616 14220.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfllID Finished Cooled Heated 1 BED 3 161 1416.8 No 1 4 1 No Yes Yes 2 HALL BATH 77 678 No 0 1 No Yes Yes 3 FOYER 172 1514 No 0 1 No Yes Yes 4 BED 4 149 1307 No 1 1 No Yes Yes 5 LAUNDRY 52 458 No 0 1 No Yes Yes 6 BED 2 149 1307 No 1 1 No Yes Yes 7 GIRT DIN KITCHEN 550 4840 No 0 1 No Yes Yes 8 MASTER SUITE 176 1544 No 2 1 No Yes Yes 9 MAST WIC 58 506 No 0 1 No Yes Yes 10 M BATH 72 634 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BED 3 38 ft 0 163 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio HALL BATH 11 ft 0 77 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulatio FOYER 25 ft 0 172 ft2 ---- 1 0 0 4 Slab -On -Grade Edge Insulatio BED 4 14 ft 0 143.5 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio LAUNDRY 1 ft 0 52 ft2 ---- 1 0 0 6 Slab -On -Grade Edge Insulatio BED 2 13.5 ft 0 148.5 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio GRT DIN KITCHE 49 ft C 550 ft2 _--- 0.5 0.5 0 7/13/2021 9:15 AM EnergyGauge& USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio MASTER SUITE 26.5 ft 0 175.5 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio MAST WIC 11.5 ft 0 57.5 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio M BATH 1 ft 0 72 ft2 ---- 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch 1/ # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1750 ft2 0 ft2 Medium N 09 No 0.9 No 0 22.6 ATTIC J# Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1616 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BED 3 30 Blown 163 ft2 0.1 Wood 2 Under Attic (Vented) HALL BATH 30 Blown 77 ft2 0.1 Wood 3 Under Attic (Vented) FOYER 30 Blown 172 ft2 0.1 Wood 4 Under Attic (Vented) BED 4 30 Blown 149 ft2 0.1 Wood 5 Under Attic (Vented) LAUNDRY 30 Blown 52 ft2 0.1 Wood 6 Under Attic (Vented) BED 2 30 Blown 149 ft2 0.1 Wood 7 Under Attic (Vented) GRT DIN KITCHE 30 Blown 550 ft' 0.1 Wood 8 Under Attic (Vented) MASTER SUITE 30 Blown 176 ft2 0.1 Wood 9 Under Attic (Vented) MAST WIC 30 Blown 58 ft2 0.1 Wood 10 Under Attic (Vented) M BATH 30 Blown 72 ft2 0.1 Wood WALLS Adjacent STo WAI Typepace Cavity Width Height Sheathing Framing Solar BeloC)rnt w 1 NE Exterior Concrete Block - Int Insul BED 3 4.1 13 1 9 4 122.1 ft2 0 0 0.5 0 2 SE Exterior Concrete Block - Int Insul BED 3 4.1 10 8 9 4 99.6 ft2 0 0 0.5 0 3 SW Exterior Concrete Block - Int Insul BED 3 4.1 12 2 10 0 121.7 ft2 0 0 0.5 0 4 SW Exterior Concrete Block - Int InsLHALL BATH 4.1 9 11 10 0 99.2 ft2 0 0 0.5 0 5 SE Exterior Concrete Block - Int Insul FOYER 4.1 4 10 9 4 45.1 ft2 0 0 0.5 0 6 SW Exterior Concrete Block - Int Insul BED 4 4.1 12 7 10 0 125.8 ftZ 0 0 0.5 0 7 NE Exterior Concrete Block - Int Insul BED 2 4.1 13 1 9 4 122.1 ft2 0 0 0.5 0 8 SW Exterior Concrete Block - Int Ins@RT DIN KIT 4.1 22 6 10 0 225.0 ftZ 0 0 0.5 0 9 NW Exterior Concrete Block - Int InsGRT DIN KIT 4.1 23 3 9 4 217 0 ft2 0 0 0.5 0 10 NE Exterior Concrete Block - Int InsMASTER SUI 4.1 12 7 9 4 117.4 ft2 0 0 0.5 0 11 NW Exterior Concrete Block - Int InsMASTER SUI 4.1 12 7 9 4 117.4 ft2 0 0 0.5 0 12 NE Exterior Concrete Block - int InsuMAST WIC 4.1 11 2 9 4 104.2 ft2 0 0 0.5 0 7/13/2021 9:15 AM EnergyGaugep USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKI IST RPPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 13 NW Garage Frame - Wood GRT DIN KIT 11 30 0 9 4 280.0 ft2 0 0 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Ft Width In Height Ft In Area 1 2 NW NW Insulated GRT DIN KIT None .46 3 Wood GRT DIN KIT None .46 2.8 8 24 ft' 8 22.4 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. 1/ # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 2 3 4 5 6 7 SE 2 Metal SW 6 Metal NE 7 Metal SW 8 Metal NW 9 Metal NW 9 Metal NW 11 Metal Double (Tinted) Yes Double (Tinted) Yes Double (Tinted) Yes Double (Tinted) Yes Double (Tinted) Yes Double (Tinted) Yes Double (Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft 0 in 0.28 0.3 N 15.0 ft2 1 ft 0 in 0.28 0.3 N 15.0 ft2 1 ft 0 in 0.55 0.34 N 41.0 ft2 11 ft 0 in 0.28 0.3 N 23.0 ft' 1 ft 0 in 0.28 0.3 N 23.0 ft2 9 ft 6 in 0.28 0.3 N 22.9 ft2 1 ft 0 in 1 ft 0 in 1 ft 0 in 1 ft 0 in 1 ft 0 in t ft 0 in 1 ft 0 in 1 ft 0 in None None None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wail Insulation 1 380 W 380 ftz 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 EL_A EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000391 1657.2 90.92 170.69 .1312 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 23 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 29.4 kBtulhr cfm 0.71 1 sys#1 7/1312021 9:15 AM EnergyGauge(D USA 7.0,00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPLIT SLIMMARY C.H1= -1fl IAT RIFpnRT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- -Supply ---- --- Return --- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 300 ft2 HALL BATH 1 ft2 Default Leakage HALL BAT (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb HeatinX� Jan f X Feb Mar Mar ki �Xj Apr Apr I Ma May X Jun X Jul Jun Jul X Aug Se [ ] Oct Nov Dec Venting Jan [ Feb Mar Apr May Jun [ Jul r j Au Aug Sep [ Se [ ] Oct X� Nov [X] Oct [X Nov Dec Dec �X� Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BED 2 Default(8 Ibslsq.ft. ft2 ft 0.3 WIC BED 2 Default(8 Ibslsq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibslsq.ft. ft2 ft 0.3 KITCHEN DINING Default(8 Ibslsq.ft. ft2 ft 0.3 GREAT ROOM Default(8 Ibslsq.ft. ft2 ft 0.3 FOYER Default(8 Ibslsq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibslsq.ft. ft2 ft 0.3 M WIC Default(8 Ibslsq.ft. ft2 ft 0.3 M TIOLET Default(8 Ibslsq.ft. ft2 ft 0.3 M BATH Default(8 Ibsls .ft. ft2 ft 0.3 MASTER SUITE 7/13/2021 9:15 AM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 5114 ARMINA PLACE, FT PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int tnsul, Exterior R=4.1 1516.70 ft2 b. Frame - Wood, Adjacent R=11.0 280.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. NIA R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1618.00 ft2 6. Conditioned floor area (ft2) 1616 b. NIA R= ft2 7. Windows** Description Area c. NIA R= ft2 a. U-Factor: Dbl, U=0.28 113.92 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: HALL BATH, AH: HALL BATH 6 300 SHGC: SHGC-0.30 b. U-Factor: Dbl, U=0.55 41.00 ft2 SHGC: SHGC=0.34 13. Cooling systems kBtu/hr Efficiency c. U-Factor: NIA ft2 a. Central Unit 29.4 SEER:16.00 SHGC: d. U-Factor: NIA ft2 SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 4.909 ft. a. Electric Strip Heat 23.0 COP:1.00 Area Weighted Average SHGC: 0.311 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): NIA it 2 a. Electric Cap: 40 gallons SHGC(AVG): NIA EF:0.95 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1616.00 ft2 Credits (Performance method) Pstat b. N/A R= ft2 c. NIA R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: �©0 WE"� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/13/2021 9:16 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1