Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEETLLl CLL ST. LUCIE WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Low Slope Application Required Sections of the Permit Application Form Attachments Required See List Below A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 Metal Roofs A, B, D Wood Shingles and Shakes A, B, D IA4,5,6,7 Other As Applicable i,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3, Design Calculations per Chapter 16, or If applicable, RAS 127 or RAS 128 4, Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 S1 LUCIE Section A (General Information) Master Permit No. Process No. Contractors Name: Collins Roofing Inc. License #! CCC-058011 Job Address �5 1 ��1 ROOF CATEGORY CI Low Slope `QYechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles ❑ Asphaltic Shingles VMetal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE.� ,, ❑ New roof ❑ Repair ❑ Maintenance Reroofing ❑ Recovering ROOF SYSTEM INFORMATION 4 Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) _ Section B (Roof Plan) Sketch Roof Plan. Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ST. LUCIE WORKS Section D (Steep Slope Roof System) Extreme Metal Fab Roof System Manufacturer: Notice of Acceptance Number: Ft_ 17023 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calcul ons(: 81 Zone 1:�Zone 2e:3CLZone 2n1�Kone 2r1��7 one 3e: Zone 3r: Deck Type: 5/8" Ply wood Type Underlayment High Temp/Self Adhesive Underlayment UX-• § cor VA("Roo Siope: 30 12 Insulation: N/A Fire Barrier: NIA Ridge Ventilation? Fastener Type & Spacing: #10x1.5"-12"x12" Pattern 16" o.c. (Wood Zac) N/A Adhesive Type: I N/A Type Cap Sheet N/A I Mean Roof Height: 15 ft Roof Covering: 26 Ga 5V Metal Roof Panels Type & Size Drip 2"x2" Galv. Steel Edge: