HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEETLLl CLL
ST. LUCIE WORKS
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
Low Slope Application
Required Sections of
the Permit Application
Form
Attachments Required
See List Below
A, B, C
1,2,3,4,5,6,7
Prescriptive BUR-RAS 150
A, B, C
2,4,5,6,7
Asphaltic Shingles
A, B, D
1,2,4,5,6,7
Concrete or Clay Tile
A, B, D, E
1,2,3,4,5,6,7
Metal Roofs
A, B, D
Wood Shingles and
Shakes
A, B, D
IA4,5,6,7
Other
As Applicable
i,2,3,4,5,6,7
ATTACHMENTS REQUIRED As Applicable):
1.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3,
Design Calculations per Chapter 16, or If applicable, RAS 127 or RAS 128
4,
Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18, 2021
S1 LUCIE
Section A (General Information)
Master Permit No.
Process No.
Contractors Name: Collins Roofing Inc. License #! CCC-058011
Job Address �5 1 ��1
ROOF CATEGORY
CI Low Slope `QYechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles
❑ Asphaltic Shingles VMetal Panel/Shingles ❑Wood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE.� ,,
❑ New roof ❑ Repair ❑ Maintenance Reroofing ❑ Recovering
ROOF SYSTEM INFORMATION
4 Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) _
Section B (Roof Plan)
Sketch Roof Plan. Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
ST. LUCIE WORKS
Section D (Steep Slope Roof System)
Extreme Metal Fab
Roof System Manufacturer:
Notice of Acceptance Number: Ft_ 17023
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calcul ons(: 81
Zone 1:�Zone 2e:3CLZone 2n1�Kone 2r1��7
one 3e: Zone 3r:
Deck Type: 5/8" Ply
wood
Type Underlayment High Temp/Self Adhesive Underlayment UX-• § cor VA("Roo Siope: 30
12 Insulation: N/A
Fire Barrier: NIA
Ridge Ventilation? Fastener Type & Spacing: #10x1.5"-12"x12" Pattern 16" o.c. (Wood Zac)
N/A
Adhesive Type: I N/A
Type Cap Sheet N/A I
Mean Roof Height: 15 ft Roof Covering: 26 Ga 5V Metal Roof Panels
Type & Size Drip 2"x2" Galv. Steel
Edge: