Loading...
HomeMy WebLinkAboutPHOTOVOLTAIC SYSTEMPV-1FREEDOM FOREVER INDY 7.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO:SHEET:REVISIONS:JOB NO:F095318DESIGNED BY:YSCLIENT:SANDRA MOGE5308 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: CITY OF PORT ST. LUCIEUTILITY: FPL - FLORIDA POWER & LIGHTSYSTEM:SYSTEM SIZE (DC): 31 x 360 = 11.160 kWSYSTEM SIZE (AC): 10.000 kW @ 240VPOI: LINE SIDE TAPMODULES: 31 x LONGI SOLAR:LR4-60HPH-360MOPTIMIZERS: P401INVERTER: SE10000H-USRGM [SI1]DATE:7/13/2021THIS PROJECT COMPLIES WITH THE FOLLOWING:2020 INTERNATIONAL BUILDING CODE (IBC)2020 INTERNATIONAL RESIDENTIAL CODE (IRC)2020 INTERNATIONAL MECHANICAL CODE (IMC)2020 INTERNATIONAL PLUMBING CODE (IPC)2020 INTERNATIONAL FUEL GAS CODE (IFGC)2020 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)2020 INTERNATIONAL EXISTING BUILDING CODE (IEBC)2020 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC)2017 NATIONAL ELECTRICAL CODE (NEC)AS ADOPTED BY CITY OF PORT ST. LUCIESITE LOCATIONCODES:VICINITY MAP:TABLE OF CONTENTS:CONSTRUCTION NOTES:PHOTOVOLTAIC SYSTEMPV-1SITE LOCATIONPV-2SITE PLANPV-2AROOF PLAN WITH MODULES LAYOUTPV-2BSTRUCTURAL CALCULATIONSPV-3MOUNTING DETAILSPV-4THREE LINE DIAGRAMPV-5CONDUCTOR CALCULATIONSPV-6EQUIPMENT & SERVICE LISTPV-7LABELSPV-7ASITE PLACARDPV-8OPTIMIZER CHARTPV-9 & 10SAFETY PLANCONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS ANDARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS.ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENTPOSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY AREMOUNTED.MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION INACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PERSECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD.DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANYEXCAVATION TAKING PLACEPHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROMDC DISCONNECT/INVERTER AS PER 2017 NEC SEC 250.166(A).SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITHREQUIREMENTS OF ART. 690 OF THE 2017 NECSYSTEM GROUNDING ELECTRODE CONDUCTOR FOR PV SYSTEM TO BE SIZED TO MEET THEREQUIREMENTS OF 2017 NECTHE EXISTING MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFERSOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDSINSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUITATTACHED TO THE ROOF USING CONDUIT MOUNT.SITE LOCATION MSPUMACINV JBSITE PLANSCALE: 1"=15'1ROOF LINEPROPERTY LINEDRIVEWAYHICKORY DRIVE(N) MAIN SERVICE PANEL(E) UTILITY METERPV-2FREEDOM FOREVER INDY 7.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO:SHEET:REVISIONS:JOB NO:F095318DESIGNED BY:YSCLIENT:SANDRA MOGE5308 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: CITY OF PORT ST. LUCIEUTILITY: FPL - FLORIDA POWER & LIGHTSYSTEM:SYSTEM SIZE (DC): 31 x 360 = 11.160 kWSYSTEM SIZE (AC): 10.000 kW @ 240VPOI: LINE SIDE TAPMODULES: 31 x LONGI SOLAR:LR4-60HPH-360MOPTIMIZERS: P401INVERTER: SE10000H-USRGM [SI1]DATE:7/13/2021WIND SPEED: 158ROOF AREA : 1912 SQ FTSITE PLAN145'-1"87'-0"145'-3"78'-7"61'-5"18'-1" 11'-0"49'-4"LEGEND:OBSTRUCTIONPIPE VENTMODULESCONDUITSETBACKMSP AC JBACDISCONNECTMSPJUNCTIONBOXINVINVERTERUTILITY METER UM MSPUMACINV JBROOF PLANSCALE: 1/8" = 1'-0"1LEGEND:OBSTRUCTIONPIPE VENTMODULESCONDUITSETBACKMSP AC JBACDISCONNECTMAIN SERVICEPANELJUNCTIONBOXINVINVERTER(N) 31 LONGI SOLAR: LR4-60HPH-360M(N) JUNCTION BOXNOTES:1.EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS2.ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES3.JUNCTION BOX IS MOUNTED TO THE RAIL.PV-2AFREEDOM FOREVER INDY 7.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO:SHEET:REVISIONS:JOB NO:F095318DESIGNED BY:YSCLIENT:SANDRA MOGE5308 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: CITY OF PORT ST. LUCIEUTILITY: FPL - FLORIDA POWER & LIGHTSYSTEM:SYSTEM SIZE (DC): 31 x 360 = 11.160 kWSYSTEM SIZE (AC): 10.000 kW @ 240VPOI: LINE SIDE TAPMODULES: 31 x LONGI SOLAR:LR4-60HPH-360MOPTIMIZERS: P401INVERTER: SE10000H-USRGM [SI1]DATE:7/13/2021ROOF LINEROOF AREA : 1912 SQ FTROOF PLAN WITH MODULES LAYOUTUTILITY METER UM 1'-6" 1'-6"1'-6"1'-6" 1'-6"1'-6"FIRE ACCESSPATHWAYSFIRE ACCESSPATHWAYSWIND SPEED: 158By Yuri at 8:16:12 AM, 8/5/2021 ROOF AREA STATEMENTROOFMODULE QUANTITYROOF PITCHARRAY PITCHAZIMUTHROOF AREAARRAY AREA11014°14°270°959 SQ FT196.5 SQ FT22115°15°90°823 SQ FT412.65 SQ FTPV-2BFREEDOM FOREVER INDY 7.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO:SHEET:REVISIONS:JOB NO:F095318DESIGNED BY:YSCLIENT:SANDRA MOGE5308 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: CITY OF PORT ST. LUCIEUTILITY: FPL - FLORIDA POWER & LIGHTSYSTEM:SYSTEM SIZE (DC): 31 x 360 = 11.160 kWSYSTEM SIZE (AC): 10.000 kW @ 240VPOI: LINE SIDE TAPMODULES: 31 x LONGI SOLAR:LR4-60HPH-360MOPTIMIZERS: P401INVERTER: SE10000H-USRGM [SI1]DATE:7/13/2021STRUCTURAL CALCULATIONS:TOTAL ROOF AREA: 1912 SQ FTARRAY COVERAGE: 31.86%SYSTEM DISTRIBUTED WEIGHT: 2.19 LBSS-5!: S-5-S CLAMP POINT-LOAD: 23.81 LBSSTRUCTURAL CALCULATIONSBy Yuri at 8:16:15 AM, 8/5/2021 (E) METAL ROOF (BY OTHERS)M8-1.25 STAINLESS STEELHEX FLANGE BOLTS-5-S CLAMP3/8-24 STAINLESS STEEL ROUNDPOINT SETSCREW (316 HEX DRIVE)(E) METAL ROOF (BY OTHERS)S-5-S CLAMP(E) 2X4 TRUSS @ 24" O.C.UNIRAC SM LIGHT RAIL RACKING SYSTEM(N) LONGI SOLAR: LR4-60HPH-360M2X4 TRUSS @ 24" O.C.ROOF ATTACHMENTATTACHMENT DETAILScale: NTSSOLAR PV ARRAY SECTION VIEWScale: NTSPARTIAL ROOF FRAMING PLANScale: NTSMAX ATTACHMENT SPAN - 'PV-3FREEDOM FOREVER INDY 7.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO:SHEET:REVISIONS:JOB NO:F095318DESIGNED BY:YSCLIENT:SANDRA MOGE5308 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: CITY OF PORT ST. LUCIEUTILITY: FPL - FLORIDA POWER & LIGHTSYSTEM:SYSTEM SIZE (DC): 31 x 360 = 11.160 kWSYSTEM SIZE (AC): 10.000 kW @ 240VPOI: LINE SIDE TAPMODULES: 31 x LONGI SOLAR:LR4-60HPH-360MOPTIMIZERS: P401INVERTER: SE10000H-USRGM [SI1]DATE:7/13/2021MOUNTING DETAILS2'2By Yuri at 8:16:17 AM, 8/5/2021 SOLAREDGE P401 POWER OPTIMIZERSJUNCTIONBOXSTRING-12 - #10 AWG, PV WIRE1 - #6 AWG IN FREE AIR OR#8 AWG MUST BE IN EMT CONDUITSTRING-2SOLAREDGE P401POWER OPTIMIZERS2 - #10 AWG,PV WIRE15 LONGI SOLAR:LR4-60HPH-360M16 LONGI SOLAR:LR4-60HPH-360M4 - #10 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" ORLARGER EMT CONDUITUM(N) 200A / 2PMAIN BREAKER(END FED)(N) 200A RATEDMAIN SERVICE PANEL1PH, 120/240V 60HZ(E) UTILITYMETER(N) LINESIDE TAP VIA ULLISTED CONNECTORS1 - #6 GEC, BARE COPPERFREE AIR BONDEDEXISTING UFER TIE INTO UTILITYOVERHEADFEED(N) 60A FUSEDAC DISCONNECTEATON DG222NRB2 - 60 AMP FUSES3 - #6 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" OR LARGER EMT CONDUITA TAPBOX MAY BE USED IN LIEU OF PERFORMING THE LINESIDETAP IN THE MAIN SERVICE PANEL. THIS IS DEPENDENT UPON SITECONDITIONS.3 - #6 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" OR LARGER EMT CONDUIT(N) SOLAREDGESE10000H-USRGM [SI1]INVERTERACDCRAPIDSHUTDOWNSWITCHCONNECT TO EXISTING UFERNOTE:CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASEDON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANTTO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONSBACKFEED FUSE SIZINGMAX. CONTINUOUS OUTPUT 42A @ 240V42.00X1.25=53AMPS60A FUSES - OKPV-4FREEDOM FOREVER INDY 7.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO:SHEET:REVISIONS:JOB NO:F095318DESIGNED BY:YSCLIENT:SANDRA MOGE5308 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: CITY OF PORT ST. LUCIEUTILITY: FPL - FLORIDA POWER & LIGHTSYSTEM:SYSTEM SIZE (DC): 31 x 360 = 11.160 kWSYSTEM SIZE (AC): 10.000 kW @ 240VPOI: LINE SIDE TAPMODULES: 31 x LONGI SOLAR:LR4-60HPH-360MOPTIMIZERS: P401INVERTER: SE10000H-USRGM [SI1]DATE:7/13/2021THREE LINE DIAGRAM DCMODULETOOPTIMIZERROOF / FREE-AIR2101.250.9411.351DCOPTIMIZERTOJUNCTION BOXROOF / FREE-AIR2101.250.9411.351DCJUNCTION BOXTOINVERTEREXTERIOR WALL481.250.9434.050.8ACINVERTERTOAC DISCONNECTEXTERIOR WALL381.250.94421ACAC DISCONNECTTOPOIEXTERIOR WALL381.250.94421PV-5FREEDOM FOREVER INDY 7.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO:SHEET:REVISIONS:JOB NO:F095318DESIGNED BY:YSCLIENT:SANDRA MOGE5308 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: CITY OF PORT ST. LUCIEUTILITY: FPL - FLORIDA POWER & LIGHTSYSTEM:SYSTEM SIZE (DC): 31 x 360 = 11.160 kWSYSTEM SIZE (AC): 10.000 kW @ 240VPOI: LINE SIDE TAPMODULES: 31 x LONGI SOLAR:LR4-60HPH-360MOPTIMIZERS: P401INVERTER: SE10000H-USRGM [SI1]DATE:7/13/2021CONDUCTOR AMPACITY DE-RATE CALCULATIONEQUIPMENTWIRE LOCATIONCONDUCTORQTY.AWG WIRESIZENEC FACTORSTABLE310.15(B)(16)NEC FACTORSTABLE310.15(B)(2)(a)CONDUCTORAMPACITY@75C ADJ.NEC FACTORSTABLE310.15(B)(3)(a)CONDUCTOR CALCULATIONS MATERIAL LIST:PV-6FREEDOM FOREVER INDY 7.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO:SHEET:REVISIONS:JOB NO:F095318DESIGNED BY:YSCLIENT:SANDRA MOGE5308 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: CITY OF PORT ST. LUCIEUTILITY: FPL - FLORIDA POWER & LIGHTSYSTEM:SYSTEM SIZE (DC): 31 x 360 = 11.160 kWSYSTEM SIZE (AC): 10.000 kW @ 240VPOI: LINE SIDE TAPMODULES: 31 x LONGI SOLAR:LR4-60HPH-360MOPTIMIZERS: P401INVERTER: SE10000H-USRGM [SI1]DATE:7/13/2021QTY.PARTPART #DESCRIPTION31MODULES114-360WLONGI SOLAR: LR4-60HPH-360M31OPTIMIZERS130-401P401 SOLAREDGE POWER OPTIMIZER - FRAME MOUNTED MODULE ADD-ON1JUNCTION BOX480-276600VDC NEMA 3R UL LISTED JUNCTION BOX2CONNECTORS240-300STAUBLI / MULTI-CONTACT MC4 CONNECTORS (FEMALE)2CONNECTORS240-301STAUBLI / MULTI-CONTACT MC4 CONNECTORS (MALE)1INVERTER120-103SE10000H-USRGM [SI1] 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN1AC DISCONNECTEATON DG222NRB60A RATED 240VAC NEMA 3R UL LISTED1FUSES330-06060A FUSE 1 PH 240VAC1FUSE REDUCER330-510100A-60A FUSE REDUCER56ROOF ATTACHMENT 1220-109S-5!: S-5-S CLAMP26RAIL 1211-100UNIRAC SM LIGHT RAIL 168 INCH (TOTAL 358 FEET NEEDED)31RAIL HARDWARE 1261-517BND T-BOLT AND NUT SS33MODULE CLAMPS 1221-101SM MIDCLAMP PRO DRK33MODULE CLAMPS 1221-202SM ENDCLAMP PRO W/ END CLAMP11SPLICE 1261-600BND SPLICE BAR PRO SERIES MILL33MLPE MOUNT 1261-510MICRO MNT BND TBOLT SS9ACCESSORIES 1211-202E-BOSS CONDUIT MOUNT COMP KIT18ACCESSORIES 1211-200E-BOSS RAIL TRAY6ACCESSORIES 1211-206E-BOSS BRIDGE TRAY10ACCESSORIES 1211-207E-BOSS BRIDGE CLIPS52GROUNDING LUG 1260-300BURNDY GROUND WEEB-LUG53L-FOOT 1241-100UNIRAC L-FOOT SERRATED W/T-BOLT CLEAR (KIT)BREAKER SIZES:SERVICE LIST:TRUEEQUIPMENT & SERVICE LIST 1. NEC ARTICLES 690 AND 705 AND IRC SECTION R324MARKINGS SHOWN HEREON.2. ALL MARKING SHALL CONSIST OF THE FOLLOWING:A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED ORMACHINE PRINTED LETTERS OR ELECTRO-PLATING.B. RED BACKGROUND COLOR WHITE TEXT AND LINEWORK.C. AERIAL FONT.3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BEHAND-WRITTEN.4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.NOTES:M690.13(B)MAIN PHOTOVOLTAICSYSTEM DISCONNECTTURN RAPIDSHUTDOWN SWITCH TOTHE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCE SHOCKHAZARD IN THE ARRAYIFC 605.11.3.1(1) & 690.56(C)SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNAC NEC 690.13(B)INVERTERDCSOLAR PV DC CIRCUITEVERY 10' ON CONDUIT AND ENCLOSURESSOLAR ELECTRICPV PANELS706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONNEC 110.27(C) & OSHA 1910.145(F)(7)!WARNINGTURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANEL!WARNINGSINGLE 120-VOLT SUPPLYDO NOT CONNECTMULTIWIRE BRANCH CIRCUITSNEC 710.15(C) & 692.9 (C)NEC 690.15 (B) & NEC 690.33(D)(2)DO NOT DISCONNECTUNDER LOADNEC 705.12(D) & NEC 690.59!CAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEDNEC 705.12(D) & NEC 690.59NEC 705.12(C) & NEC 690.59!WARNINGDUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!WARNINGPOWER SOURCE OUTPUTCONNECTION. DO NOTRELOCATE THISOVERCURRENT DEVICE.!WARNINGARC FLASH AND SHOCK HAZARDAPPROPRIATE PPE REQUIRED24 INCH3480 VAC42 INCH12 INCH1 INCHFLASH HAZARD BOUNDARYCAL/CM^2 FLASH HAZARD AT 18 INCHESSHOCK HAZARD WHEN COVER IS REMOVEDLIMITED APPROACHRESTRICTED APPROACH - 500 V CLASS 00 GLOVESPROHIBITED APPROACH - 500 V CLASS 00 GLOVESLOCATION:5308 HICKORY DRIVE,FORT PIERCE, FL 34982PHOTOVOLTAICAC DISCONNECTPHOTOVOLTAIC AC DISCONNECTRATED AC OUTPUT CURRENT:NOMINAL OPERATING AC VOLTAGE:42.00A240V!WARNINGTHIS EQUIPMENT FED BYMULTIPLE SOURCES:TOTAL RATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEED AMPACITY OF BUSBARNEC 690.54NEC 705.12(B)(3)(3)NEC 706.15(C) AND NEC 110.16PM NEC 705.12(D) & NEC 690.59!WARNINGDUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!WARNINGTHE DISCONNECTION OF THEGROUNDED CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENTNEC 690.31(E)PHOTOVOLTAIC POWER SOURCEEVERY 10' ON CONDUIT AND ENCLOSURESNEC 690.31(O)(2)NEC 690.31(D)(2) NEC 690.13(B)PHOTOVOLTAICDC DISCONNECT706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONDC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULESARE EXPOSED TO SUNLIGHT NEC 690.53MAXIMUM DC VOLTAGEOF PV SYSTEMARRAYJ/BNEC 690.31(G)(3) & (4)706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONNEC 110.27(C) & OSHA 1910.145(F)(7)!WARNINGTURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELPV-7FREEDOM FOREVER INDY 7.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO:SHEET:REVISIONS:JOB NO:F095318DESIGNED BY:YSCLIENT:SANDRA MOGE5308 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: CITY OF PORT ST. LUCIEUTILITY: FPL - FLORIDA POWER & LIGHTSYSTEM:SYSTEM SIZE (DC): 31 x 360 = 11.160 kWSYSTEM SIZE (AC): 10.000 kW @ 240VPOI: LINE SIDE TAPMODULES: 31 x LONGI SOLAR:LR4-60HPH-360MOPTIMIZERS: P401INVERTER: SE10000H-USRGM [SI1]DATE:7/13/2021LABELS MSPUMACINV JB HICKORY DRIVE UTILITY METERCAUTION:MULTIPLE SOURCES OF POWER LOCATED AS SHOWN.DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES6X8" TYP - NEC 705.10PV-7AFREEDOM FOREVER INDY 7.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO:SHEET:REVISIONS:JOB NO:F095318DESIGNED BY:YSCLIENT:SANDRA MOGE5308 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: CITY OF PORT ST. LUCIEUTILITY: FPL - FLORIDA POWER & LIGHTSYSTEM:SYSTEM SIZE (DC): 31 x 360 = 11.160 kWSYSTEM SIZE (AC): 10.000 kW @ 240VPOI: LINE SIDE TAPMODULES: 31 x LONGI SOLAR:LR4-60HPH-360MOPTIMIZERS: P401INVERTER: SE10000H-USRGM [SI1]DATE:7/13/20211.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK.C.AERIAL FONT.3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN.4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.NOTES:SITE PLACARDAC DISCONNECTMAIN SERVICE PANELINVERTER EQUIPPEDWITH RAPID SHUTDOWN 123456789101-1011-2021-3031-4041-5051-60123456789101-1011-2021-3031-4041-5051-60PV-8FREEDOM FOREVER INDY 7.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO:SHEET:REVISIONS:JOB NO:F095318DESIGNED BY:YSCLIENT:SANDRA MOGE5308 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: CITY OF PORT ST. LUCIEUTILITY: FPL - FLORIDA POWER & LIGHTSYSTEM:SYSTEM SIZE (DC): 31 x 360 = 11.160 kWSYSTEM SIZE (AC): 10.000 kW @ 240VPOI: LINE SIDE TAPMODULES: 31 x LONGI SOLAR:LR4-60HPH-360MOPTIMIZERS: P401INVERTER: SE10000H-USRGM [SI1]DATE:7/13/2021SOLAREDGE OPTIMIZER CHARTOPTIMIZER CHART SAFETY PLANMARK UP KEYINSTRUCTIONS:1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET.2.SAFETY PLAN MUST BE MARKED BEFORE JOBSTARTS AS PART OF THE PRE-PLAN3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE& MAKE NOTES ON THE JHA SHEETIN CASE OF EMERGENCYNEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINICNAME: _______________________________________________ADDRESS: ___________________________________________SAFETY COACH CONTACT INFORMATIONNAME: _______________________________________________ADDRESS: ___________________________________________ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THESAFETY PLAN AND SIGN INDICATING THAT THEY AREAWARE OF THE HAZARDS ON-SITE AND THE PLAN FORWORKING SAFELY. NAME SIGNATURE__________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ ________________DATE: ______________ TIME:___________________________PERMANENT ANCHORTEMPORARY ANCHORINSTALLER LADDERJUNCTION / COMBINER BOXSTUB-OUTSKYLIGHTNO LADDER ACCESS (STEEPGRADE OR GROUND LEVELOBSTRUCTIONS)RESTRICTED ACCESSCONDUITGAS SHUT OFFWATER SHUT OFFSERVICE DROPPOWER LINESPTILBS7ZGASH2OPV-9FREEDOM FOREVER INDY 7.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO:SHEET:REVISIONS:JOB NO:F095318DESIGNED BY:YSCLIENT:SANDRA MOGE5308 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: CITY OF PORT ST. LUCIEUTILITY: FPL - FLORIDA POWER & LIGHTSYSTEM:SYSTEM SIZE (DC): 31 x 360 = 11.160 kWSYSTEM SIZE (AC): 10.000 kW @ 240VPOI: LINE SIDE TAPMODULES: 31 x LONGI SOLAR:LR4-60HPH-360MOPTIMIZERS: P401INVERTER: SE10000H-USRGM [SI1]DATE:7/13/2021SAFETY PLAN JOB HAZARD ANALYSISCrew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site CaptureLadder Access·Ladders must be inspected before each use.·Extension ladders must be set up on a firm and level surface ata 4-to-1 rise to run angle (or 75 degrees) and the top must besecured to the structure. Extension style ladders placed onuneven, loose or slippery surfaces must additionally have thebase firmly anchored or lashed so the base will not slip out.·Extension ladders must be used with walk-through devices orthe ladder must extend 36" above the stepping off point.·A-frame ladders must only be climbed with the ladder spreaderbars locked in the open position; A-frame ladders shall not beclimbed while in the closed position (ex, closed and used whileleaned against a structure).·Additional notes:Mobile Equipment·Only Qualified operators will operate equipment; operators mustmaintain a certification on their person for the equipment beingoperated.·Type(s) of mobile equipment (Type/Make/Model):·Qualified operator(s):Material Handling and Storage·Materials will be staged/stored in a way that does not present ahazard to client, personnel or public. Materials stored on theroof will be physically protect from failing or sliding off.Fall Protection·A site-specific plan for fall prevention and protection is requiredprior to starting work and must remain onsite at all times untilwork is complete; a fall rescue plan must be outlined anddiscussed among the crew prior to work start.·First-person-Up (FPU) must install their anchor and connectbefore any other task, including installing other anchors. TheLast-Person-Down (LPD) must be the only person on a roofuninstalling fall protection.·FPCP (name and title):·FPU and LPD (name and title):Electrical Safety·The Electrical Qualified Person (EQP) is required onsite toperform electrical work.·All electrical work will be performed with equipment in anelectrically safe condition (de-energized) unless approval hasbeen granted prior to work.·Service drops and overhead electrical hazards will be indentifiedand protected from contact, as neccessary.·EQP (name and tile):Public Protection·The safety of the Client and Public must be maintained at alltimes.·The Client and the Public shall be prevented from entering thework zone through the use of barriers and/or signage, asrequired.·Company, Client and Public property shall be protected fromfalling objects.·Pets (including dogs) shall be secured by their owners prior towork start.·The Client should not leave pets, family members, or others incharge or care of Employees, Contractors, or TemporaryWorkers.·Crew leader responsible for communication with the client:·Client and public is excluded from work area by barricades (N/A,Yes, No):Training and Pre-Job Safety Briefing·All employees onsite shall be made aware of the specific hazardsof this project and review this HJA during a pre-job briefing, andtheir signature indicates awareness of site conditions and theplan to eliminate any hazards identified prior to and during theproject.·Crew leader (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):Airborne Contaminants:·Asbestos-containing (Transite) piping (ACP) - Do not disturb(move, drill, cut fracture, etc.)·Asbestos-containing thermal insulation (ACI) andAsbestos-containing duct wrapping (ACW) - do not disturb, noattic or crawlspace access is allowed if work to be performedcould cause exposure to personnel, client or public.·If yes, list specific tasks and protection in place:Weather and Environment·The site supervisor shall forecast the weather conditions at thejob site, prior to crew arrival, in order to mitigate any hazardsassociated with inclement weather (heat, cold, wind, rain, etc.)·The site supervisor will utilized a portable wind meter(anemometer) to verify actual onsite wind conditions, by checkingat the ground and on any elevated work surface (ex, rooftop)prior to work start, at midday and prior to solar panel staging on aroof.·Elevated work involving the moving or maneuvering of solarpanels shall cease at 25mph (sustained wind) until windsubsides.·Forecasted weather maximum temp (degrees f):Heat Related Illness Prevention·Employees shall have access to potable drinking water that isfresh, pure, and suitably cool. The water shall be located asclose as practicable to the areas where employees are working.Water shall be supplied in sufficient quantity at the beginning ofthe work shift to provide at least one quart per employee perhour for drinking for the entire shift. Employees may begin theshift with smaller quantities of water if they identify the locationand have effective means for replenishment during the shift toallow employees to drink on quart or more per hour. Thefrequent drinking of water shall be encouraged.·Shade shall be present when temperature exceeds 80 degreesFahrenheit. When the outdoor temperature in the work exceeds80 degrees Fahrenheit, employees shall have and maintain oneor more areas with shade at all times.·New employees must be acclimatized. New employees will bemonitored by their Crew Leader (site supervisor) for the first two(2) weeks of employment or longer when necessary.·Employees will be allowed and encouraged to implementscheduled breaks during each shift. Employees must takecool-down breaks in the shade any time they feel the need to doso to protect them from overheating. Supervisors areREQUIRED to allow employees any break period they needduring high heat conditions.·Cool Vests are encouraged for all employees at all times duringperiods of high heat.·Identify the location of the closet Occupational/Industrial Clinicor Hospital in case a crew member becomes ill.What is the specific plan to provide and replenish sufficient water forall employees on site?·If offsite replenish is necessary, where will you go to replenishwater (location/address):·Who will replenish the drinking water (name):Restroom facilities·Employees shall have access to restroom facilities withhand-washing stations. Use of onsite restroom is at the client'sdiscretion (location is annotated below). If client does not givepermission, location of suitable restroom facilities withhand-washing stations offsite will be provided. The onsitesupervisor will identify location and make arrangements toensure all employees have access at any point.·Restroom facilities will be (circle one): Onsite - Offsite·If Offsite, add location name and address:Incident Reporting Procedure·Contact your Site SupervisorName:Phone:·Contact your ManagerName:Phone:·Contact your Site SupervisorName:Phone:With: Your full name, phone number, office location, brief descriptionof what happen and when.NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE(add as many as necessary by using additional sheets)Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:PV-10FREEDOM FOREVER INDY 7.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER FLORIDA LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075GREG ALBRIGHTDESCRIPTIONDATENO:SHEET:REVISIONS:JOB NO:F095318DESIGNED BY:YSCLIENT:SANDRA MOGE5308 HICKORY DRIVE, FORT PIERCE, FL34982AHJ: CITY OF PORT ST. LUCIEUTILITY: FPL - FLORIDA POWER & LIGHTSYSTEM:SYSTEM SIZE (DC): 31 x 360 = 11.160 kWSYSTEM SIZE (AC): 10.000 kW @ 240VPOI: LINE SIDE TAPMODULES: 31 x LONGI SOLAR:LR4-60HPH-360MOPTIMIZERS: P401INVERTER: SE10000H-USRGM [SI1]DATE:7/13/2021SAFETY PLAN solaredge.com P370 / P401 / P404 / P500 Specifcally designed to work with SolarEdge inverters Quicker installation - Power optimizers can be mounted in advance saving installation time Up to 25% more energy Mitigates all types of modules mismatch-loss, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Next generation maintenance with module level monitoring Module-level voltage shutdown for installer and © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2020/V01/ENG ROW. Subject to change without notice. P370 / P401 / P404 / P500 Supported frame cross section 1.1-2.2mm / 370 400 W Absolute Maximum Input Voltage Vdc MPPT Operating Range Vdc 11 11.75 11 10.1 Adc % % II 15 Adc Maximum Output Voltage Vdc Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc Safety RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 Maximum Allowed System Voltage 1000 Vdc mm / in 775 / 1.7 gr / lb Input Wire Length m / ft Output Wire Length m / ft Operating Temperature Range Protection Rating Relative Humidity 0 - 100 % Minimum String Length P370/ P401/ P500 P404 14 25 50 50 Maximum Nominal Power per String 5700 5250 11250 12750 W Parallel Strings of Different Lengths or Orientations Yes 403 500 Take your business to the next level with SFM INFINITY, UNIRAC’s rail-less PV mounting system for flush mount installations on comp shingle and tile roofs. An advanced 3rd generation product platform in use by top solar contractors nationwide, SFM INFINITY optimizes your operations on and off the roof, with approximately 40% less labor, 30% logistics savings, and 20% fewer roof attachments than traditional solar racking. Plus, 87% of homeowners prefer SFM INFINITY’s aesthetics.SUPERIOR PERFORMANCEEnhance your business with two installs per dayand 30% less cost.EASY INSTALLATIONPre-assembled components, 20% fewer roof attachments, and level array in seconds with post height adjustment. HOMEOWNER PREFERREDMore than 4 out of 5 homeowners prefer SFM INFINITY’S aesthetics over a leading rail brand.SFM INFINITYFRONT TRIM AND END CAPSUNIVERSAL COMPONENTSFIT 32 – 40MM MODULESEOWNERPREFERRED25 YEAR FULL-SYSTEM WARRANTYONE SKU FITS 32 TO 40mmREVOLUTIONIZING ROOFTOP SOLARFOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702REVOLUTIONIZING ROOFTOP SOLARFOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702SFM INFINITYDESIGN GUIDELINESAPPLICATION GUIDEWhile you will see advantages simply from switching to SFM INFINITY, the following guidelines will help you to maximize its benefits.When possible, design in landscape orientation in order to fit more modules on the roof and minimize roof attachments.DEFAULT TO LANDSCAPESFM INFINITY is easily configured in mixed array shapes and module orientations to maximize array density and to avoid vent pipes and other obstacles. Because mounting locations are not constrained by rails, SFM INFINITY has unmatched flexibility to enhance your projects.MIX MODULE ORIENTATIONSVisit UNIRAC’s mobile-friendly library of short, topic-specific videos which answer common questions and demonstrate how simple it is to install SFM INFINITY.CONSULT THE QUICK TIPS VIDEOSQuick Tips Videos: https://unirac.com/SFM-Infinity/ Layout your arrays in U-Builder, UNIRAC’s free solar design software, to optimize SFM INFINITY’S capabilities, including mixing module orientations and minimizing roof attachments. Quickly create layouts on Google or Bing Maps and generate project documents.DESIGN IN U-BUILDERU-Builder: https://design.unirac.com/ The S-5-E clamp is secured with our patented round-point setscrews without piercing the metal roof panel, thereby preserving the roof manufacturer's warranty!The right way to attach almost anything to metal roofs! S-5-E and S-5-E Mini888-825-3432 | www.S-5.com | S-5-E ClampThe S-5-E clamp is designed specially for double-folded standing seam roof profiles having the appropriate dimensioning.Although a bit smaller and less expensive than the S-5-U, for these profiles, the S-5-E is just as strong.The S-5-E is perfect for use with S-5!® ColorGard® snow retention systems and other heavy-duty applications.Installation is as simple as placing the clamp on the seam and tightening the patented round-point setscrews to the specified tension. Then, affix ancillary items using the bolt provided. Go to www.S-5.com/tools for information and tools available for properly attaching and tensioning S-5! clamps.S-5-E Mini ClampThe S-5-E Mini is a bit shorter than the S-5-E and has one setscrew rather than two. The mini is the choice for attaching all kinds of rooftop accessories: signs, walkways, satellite dishes, antennas, rooftop lighting, lightning protection systems, solar arrays, exhaust stack bracing, conduit, condensate lines, mechanical equipment—just about anything!**S-5! mini clamps are not compatible with, and should not be used with S-5! SnoRail™/SnoFence™ or ColorGard® snow retention systems.Distributed byS-5!® Warning! Please use this product responsibly!Products are protected by multiple U.S. and foreign patents. Visit the website at www.S-5.com for complete information on patents and trademarks. For maximum holding strength, setscrews should be tensioned and re-tensioned as the seam material compresses. Clamp setscrew tension should be verified using a calibrated torque wrench between 160 and 180 inch pounds when used on 22ga steel, and between 130 and 150 inch pounds for all other metals and thinner gauges of steel. Consult the S-5! website at www.S-5.com for published data regarding holding strength.Copyright 2015, Metal Roof Innovations, Ltd. S-5! products are patent protected. S-5! aggressively protects its patents, trademarks, and copyrights. Version 052115.The strength of the S-5-E clamp is in its simple design. The patented setscrews will slightly dimple the metal seam material but will not puncture it—leaving roof warranties intact.S-5-E Mini ClampS-5-E ClampPlease note: All measurements are rounded to the second decimal place.The S-5-E and S-5-E Mini clamps are each furnished with the hardware shown to the right. Each box also includes a bit tip for tightening setscrews using an electric screw gun. A structural aluminum attachment clamp, the S-5-E is compatible with most common metal roofing materials excluding copper. All included hardware is stainless steel. Please visit www.S-5.com for more information including CAD details, metallurgical compatibilities and specifications.The S-5-E and S-5-E Mini clamps have been tested for load-to-failure results on a variety of double-folded standing seam roofs, from leading manufacturers of panels and panel-forming machines. The independent lab test reports found on our website at www.S-5.com prove that S-5!® holding strength is unmatched in the industry.E[ample Pro¿lesFor horizontal seams under .5", crimp the seam to 180 degrees at desired clamp location.This illustration demonstrates crimping technique, NOT actual location of clamp.”1.18" (30.00 mm)0.98" (25.00 mm)1.97" (50.00 mm)0.60" (15.00 mm)(2x) M8-1.25Threaded HoleM8-1.25Threaded Hole1.18" (30.00 mm)0.98" (25.00 mm)1.18" (30.00 mm)0.30" (7.60 mm)0.35" (8.90 mm)0.30" (7.60 mm)0.35" (8.90 mm)0.60" (15.00 mm)M8-1.25 X 16 mmHex Flange BoltM8-1.25 X 16 mmHex Flange BoltOne 3/8-24 X 0.80"Round-Point SetscrewsTwo 3/8-24 X 0.80"Round-Point Setscrews Report No. 102393982LAX-002Unirac, IncPage 2 of 107Issued: 11-Apr-2016Revised: 20-Mar-2019Product Brand nameModelsUnirac SFM2.0 Product DescriptionPhotovoltaic Mounting System, Sun Frame Microrail - Installed Using Unirac Installation Guide, Rev PUB2019MAR01 with Annex North Row Extension Installation Guide Rev PUB2019FEB20UniracDescriptionThe product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic Rack Mounting System. This system is designed to provide bonding and grounding to photovoltaic modules. The mounting system employs anodized or mill finish aluminum brackets that are roof mounted using the slider, outlined in section 4 of this report. There are no rails within this product, whereas the 3" Micro Rail, Floating Splice, and 9" Attached Splice electrically bond the modules together forming the path to ground.The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the modules to the bracket. The bonding pin of the Micro Rail when bolted and torqued, penetrate the anodized coating of the photovoltaic module frame to contact the metal, creating a bonded connection from module to module.The grounding of the entire system is intended to be in accordance with the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems. Any local electrical codes must be adhered in addition to thenational electrical codes. The Grounding Lug is secured to the photovoltaic module, torqued in accordance with the installation manual provided in this document. Other optional grounding includes the use of the Enphase UL2703 certified grounding system, which requires a minimum of 2 micro-inverters mounted to the same rail, and using the same engage cable.ED 16.3.15 (20-Apr-17) MandatoryReport No. 102393982LAX-002Unirac, IncPage 3 of 107Issued: 11-Apr-2016Revised: 20-Mar-20192.0 Product DescriptionModel SimilarityOther RatingsNAFuse Rating: 30AModule Orientation: Portrait or LandscapeMaximum Module Size: 17.98 ftϸUL2703 Design Load Rating:33 PSF Downward, 33 PSF Upward, 10 PSF Down-SlopeTested Loads - 50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down SlopeTrina TSM-255PD05.08 and Sunpower SPR-E20-327 used for Mechanical LoadingIncreased size ML test:Maximum Module Size: 22.3 ft²UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down-SlopeLG355S2W-A5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of 24"UL2703 Design Load Rating: 46.9 PSF Downward, 40 PSF Upward, 10 PSF Down-Slope LG395N2W-A5, LG360S2W-A5 and LG355S2W-A5 used for used for Mechanical Loading test. Mounting configuration: Six mountings for two modules used with the maximum span of 74.5" Fire Class Resistance Rating:- Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at anyinterstitial gap. Installations must include Trim Rail.- Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at anyinterstitial gap. Installations must include Trim Rail.- Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules.This system was evaluated with a 5” gap between the bottom of the module and the roof’ssurfaceSee section 7.0 illustraction # 1 and 1a for a complete list of PV modules evaluated with these racking systemsRatingsNAED 16.3.15 (20-Apr-17) Mandatory Address: Intertek 3933 US 11 Cortland NY 13045 Telephone: 607-758-6516 www.intertek.com This information is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense, or damage occasioned by the use of this information. Any observations and results in this report are relevant only to the sample evaluated. Only the Client is authorized to copy and distribute this information and only then in its entirety. © 2018 Intertek Version: 8-September-2016 Page 1 of 3 GFT-OP-10a Subject: ETL Evaluation of SolarEdge Products to NEC 2017 Rapid Shutdown Requirements To, whom it may concern This letter represents the testing results of the below listed products to the requirements contained in the following standards: National Electric Code, 2017, Section 690.12 requirement for rapid shutdown. UL 1741, UL 1741 CRD for rapid shutdown The evaluation was done on the PV Rapid Shutdown System (PVRSS), and covers installations consisting of optimizers and inverters with part numbers listed below. The testing done has verified that controlled conductors are limited to: x Not more than 30 volts and 240 voltamperes within 30 seconds of rapid shutdown initiation outside the array. x Not more than 80 volts and 240 voltamperes within 30 seconds of rapid shutdown initiation inside the array. The rapid shutdown initiation is performed by either disconnecting the AC feed to the inverter, or – if the inverter DC Safety switch is readily accessible – by turning off the DC Safety switch. Applicable products: x Power optimizers: o PB followed by 001 to 350; followed by -AOB or -TFI. OP followed by 001 to 500; followed by -LV, -MV, -IV or -EV. P followed by 001 to 850. SP followed by 001 to 350. *When optimizers are connected to 2 or more modules in series, the max input voltage may exceed 80V. Following the implementation of the NEC 2017 rapid shutdown value of 80V max inside of the array at the beginning of 2019 , modules exceeding this combined input max voltage will be required to use optimizers with parallel inputs. x 1-ph Inverters: Address: Intertek 3933 US 11 Cortland NY 13045 Telephone: 607-758-6516 www.intertek.com This information is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense, or damage occasioned by the use of this information. Any observations and results in this report are relevant only to the sample evaluated. Only the Client is authorized to copy and distribute this information and only then in its entirety. © 2018 Intertek Version: 8-September-2016 Page 2 of 3 GFT-OP-10a o SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A-US / SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US when the following label is labeled on the side of the inverter: Inverter part number may be followed by a suffix x 3-ph Inverters: o SE9KUS / SE10KUS / SE14.4KUS / SE20KUS / SE30KUS / SE33.3KUS /SE43.2KUS / SE66.6KUS / SE100KUS ; when the following label is labeled on the side of the inverter: Inverter part number may be followed by a suffix If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact the undersigned. DQD 507 Rev. 2016-02-18 Page 1 Certificate of Compliance Certificate: 70131735 Master Contract: 266909 (266909) Project: 70185553 Date Issued: 2018-10-08 Issued to: Unirac 1411 Broadway NE Albuquerque, New Mexico 87102 USA Attention: Klaus Nicolaedis The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Michael Hoffnagle Michael Hoffnagle PRODUCTS CLASS - C531302 - POWER SUPPLIES- PHOTOVOLTAICS--PV Racking CLASS - C531382 - POWER SUPPLIES- PHOTOVOLTAICS-PV Racking and clamping systems-Certified to US Standards Models: SM SOLARMOUNT Flush-to-Roof is an extruded aluminum rail PV racking system that is installed parallel to the roof in landscape or portrait orientations. ULA Unirac Large Array is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. SOLARMOUNT The system listed is designed to provide bonding/grounding, and mechanical stability for photovoltaic modules. The system is secured to the roof with the L-Foot components through the roofing material to building structure. Modules are secured to the racking system with stainless steel or aluminum mid clamps and Aluminum end clamps. The modules are bonded to the racking system with the stainless steel bonding mid clamps with piercing points. The system is grounded with 10 AWG copper wire to bonding/grounding lugs. Fire ratings of Class A with Type 1, 2, 3, or 10 for steep slope. Tested at 5” interstitial gap which allows installation at any stand-off height. Certificate: 70131735 Project: 70185553 Master Contract: 266909 Date Issued: 2018-10-08 DQD 507 Rev. 2016-02-18 Page 2 The grounding of the system is intended to comply with the latest edition of the National Electrical Code, to include NEC 250 & 690. Local codes compliance is required, in addition to national codes. All grounding/bonding connections are to be torqued in accordance with the Installation Manual and the settings used during the certification testing for the current edition of the project report. The system may employ optimizers/micro-inverters and used for grounding when installed per installation instructions. Mechanical ratings: Downward Design Load (lb/ft²) 113.4 Upward Design Load (lb/ft²) 50.4 Down-Slope Load (lb/ft²) 14.7 Conditions of acceptability: Installation is subject to acceptance of the local inspection authorities having jurisdiction. The certification of these products relates only to the methods of installation, bonding, and grounding as outlined in the Installation Manual for each product. Unirac Large Array ULA is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. ULA aluminum components merge with SM rails and installer-supplied steel pipe. The SM rail system is secured to the horizontal Pipe using the Rail Bracket components. The Rear and Front cap secures the horizontal Pipe to the vertical Pipe. The Front cap is also used to secure the Cross brace. A Slider is attached to the vertical Pipe to secure the Cross brace. The SM rails, caps, slider, rail brackets, and cross braces materials are 6105-T5 aluminum extrusion. Fasteners materials are 304 stainless steel. Horizontal and vertical pipe materials meet the minimum requirements of ASTM A53 for galvanized steel pipe in 2” and 3” diameter. The mechanical load ratings from the SM test data will be applied to the ULA model. Fire Testing is not applicable due to being a ground mount system. APPLICABLE REQUIREMENTS UL 2703-1st Edition - Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels. LTR AE-001-2012 - List of Technical Requirements for Photovoltaic Module and Panel racking Systems MARKINGS The manufacturer is required to apply the following markings: x Products shall be marked with the markings specified by the particular product standard. x Products certified for Canada shall have all Caution and Warning markings in both English and French. AUTHORIZATION TO MARK Applicant:Manufacturer: Address:Address: Country:Country: Contact:Contact: Phone:Phone: FAX:FAX: Email:Email: Standard(s): Product: Brand Name: Models: This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed.1] Photovoltaic Mounting System, Sun Frame Microrail - Installed Using Unirac Installation Guide, Rev PUB2019MAR01 with Annex North Row Extension Installation Guide Rev PUB2019FEB20 Unirac SFM Unirac Control Number:5003705 Authorized by: for Dean Davidson, Certification Manager This document supersedes all previous Authorizations to Mark for the noted Report Number. klaus.nicolaedis@unirac.com toddg@unirac.com jia.liu@cxymj.com buwan.luo@cxymj.com Party Authorized To Apply Mark:Same as Manufacturer Report Issuing Office:Lake Forest, CA U.S.A. Klaus Nicolaedis Tom Young Jia Liu Robin Luo 505-462-2190 505-843-1418 +86-15267030962 +86-13621785753 NA NA Unirac, Inc Cixi Emeka Aluminum Co. Ltd 1411 Broadway Blvd NE Albuquerque, NM 87102 No. 688 ChaoSheng Road Cixi City Zhejiang Province 315311 USA China This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Page 1 of 1 ATM for Report 102393982LAX-002 ATM Issued: 9-Apr-2019 ED 16.3.15 (20-Apr-17) Mandatory January 20, 2021 Unirac 1411 Broadway Blvd. NE Albuquerque, NM 87102 Attn.: Unirac - Engineering Department Re: Engineering Certification for the Unirac U-Builder 2.0 SOLARMOUNT Flush Rail PZSE, Inc. - Structural Engineers has reviewed the Unirac SOLARMOUNT rails, proprietary mounting system constructed from modular parts which is intended for rooftop installation of solar photovoltaic (PV) panels; and has reviewed the U- builder Online tool. This U-Builder software includes analysis for the SOLARMOUNT LIGHT rail, SOLARMOUNT STANDARD rail, and SOLARMOUNT HEAVY DUTY rail with Standard and Pro Series hardware. All information, data and analysis contained within are based on, and comply with the following codes and typical specifications: 1. 2020 Florida Building Code, by Florida Building Commission 2. Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-16 3. 2018 International Building Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017. 4. 2018 International Residential Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017. 5. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES. 6. 2015 Aluminum Design Manual, by The Aluminum Association, 2015 Following are typical specifications to meet the above code requirements: Design Criteria: Ground Snow Load = 0 - 100 (psf) Basic Wind Speed = 85 - 190 (mph) Roof Mean Height = 0 - 60 (ft) Roof Pitch = 0 - 45 (degrees) Exposure Category = B, C & D Attachment Spacing: Per U-builder Engineering report. Cantilever: Maximum cantilever length is L/3, where “L” is the span noted in the U-Builder online tool. Clearance: 2” to 10” clear from top of roof to top of PV panel. Tolerance(s): 1.0” tolerance for any specified dimension in this report is allowed for installation. Installation Orientation: See SOLARMOUNT Rail Flush Installation Guide. Landscape - PV Panel long dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the long side. Portrait - PV Panel short dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the short side. 8150 Sierra College Boulevard, Suite 150, Roseville, CA 95661 T 916.961.3960 F 916.961.3965 W www.pzse.com Experience | Integrity | Empowerment 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 T 916.961.3960 F 916.961.3965 W www.pzse.com Experience | Integrity | Empowerment Components and Cladding Roof Zones: The Components and Cladding Roof Zones shall be determined based on ASCE 7-16 Component and Cladding design. Notes: 1) U-builder Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems only and do not include roof capacity check. 2) Risk Category II per ASCE 7-16. 3) Topographic factor, kzt is 1.0. 4) Array Edge Factor ƳE = 1.5 5) Average parapet height is 0.0 ft. 6) Wind speeds are LRFD values. 7) Attachment spacing(s) apply to a seismic design category E or less. Design Responsibility: The U-Builder design software is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, this U-builder software should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: • Evaluate whether the U-Builder Software is applicable to the project, and • Understand and determine the appropriate values for all input parameters of the U-Builder software. This letter certifies that the Unirac SM SOLARMOUNT Rails Flush, when installed according to the U-Builder engineering report and the manufacture specifications, is in compliance with the above codes and loading criteria. This certification excludes evaluation of the following components: 1) The structure to support the loads imposed on the building by the array; including, but not limited to: strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/or the effects of snow accumulation on the structure. 2) The attachment of the SM SOLARMOUNT Rails to the existing structure. 3) The capacity of the solar module frame to resist the loads. This requires additional knowledge of the building and is outside the scope of the certification of this racking system. If you have any questions on the above, do not hesitate to call. Prepared by: PZSE, Inc. – Structural Engineers Roseville, CA 8150 Sierra College Boulevard, Suite 150, Roseville, CA 95661 T 916.961.3960 F 916.961.3965 W www.pzse.com Experience | Integrity | Empowerment 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 T 916.961.3960 F 916.961.3965 W www.pzse.com Experience | Integrity | Empowerment EXP. 02/28/2023 ZACH E RPAULK. E NSECIL A R I D AOLF NOISS E FORP L E N G INEERSTATE OF No. 73522 THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY PAUL K. ZACHER, PE ON 01/20/2021 USING A SHA-1 AUTHENTICATION CODE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA-1 AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. 01/20/2021 DIGITAL SIGNATURE