Loading...
HomeMy WebLinkAboutNOA- — DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADM)NISTRATION DIVISION NOTICE OF ACCEPTANCE GAF I Campus Drive Parsippany, NX 07054 ---SCOPE: -------------- ------- - MJAMI-DADS COUNTY PRODUCT CONTROL SECTION 805 SW 26SheeY, Raom 208 M arat Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miam idade.eov/economy This NOA is being issued under the applicable xules an$ regulations governing the use o£cola uctionmaterialS. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AM, This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AI1J may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revolve this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Cobra® Exhaust Vent for Roof Ridge, LABELING: Each uurit, shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. .RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERNIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date maybe displayed in advertising literature. If any portion of the NOA is displayed, Then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available £or inspection at.the job site at the request of the Building Official. This NOA renews and revises NOA No. 18-0619.02 and consists of pages 1 through 3. The submitted documentation was reviewed by Jorge L. Acebo. .PoIAM4DAOECOUNTY NOA No.19-0123.05 Expiraiion Date: 11/09/23 Approval Date: 05/16/19 Page 1 of 3 ROOFING COMPONENT APPROVAL Category: Roofih - - - — - Sub -Category: Ventilation Materials:. Plastic TRADE NAMES OF PRODUCTS Mf ANpFACTURED OR LABELED By APPLICANT; Product Dimensions -'GAT Cobra x aust eut 3/�1/2" x ZO' for Roof Ridge GAF Cobra° Exhaust Vettt for Roof Ridge (For nail guns) EVIDENCE SUBMITTED; 1. Acworth, GA. EVIDENCE SUBMITTED; Test A2eney/Identifier Intertek "Architectural Testing Intertelc M(F1MI•DAUECOUNTY 5/8" x 101/2" x 20' Test Product Specifiication DgscriDtion TAS-100 Low profile attic ridge vent for installation under ridge shingles. Name TAS 100(A) ASTMD 1929 ASTM D 635 ASTM D 2843 ASTMD 1929 ASTM D 635 ASTMD 2843 TAS-100 Low profile attic ridge vent for installation under ridge shingles. Re ort Date 13223.01409-18 06/06/18 I3223.0240648 Rl 07/20/18 I3223.02-16648 Rl 07/20/18 I3223.02406-18 RI 07/20/18 J0478.01-10648 RO 01/08/19 J0478.01406-18RO 01/08/19 J0478.01-10648 RO 01/08/19 NOA No.19-0123.05 Expiration Date: 11/09/23 Approval Date: 05/16/19 Page 2 of 3 - - -APPROVED APPLICATIo1VS - - - - Tradename: GAF Cobra® Exhaust Vent for Roof Ridge System Type: Mechanical attachment of static vent over asphalt shingle roof systems only. Cutout: Cut a 2" slot along the ridge of the roof 'by cutting 1" on each side of the ridge. Leave uncut sheathing area of 6" at each end of the ridge. Cut through sheathing only, avoiding roof hnsses. -- --- - ---- -1tt buildings with a -ridge hoard,. cut 1-3/4" slot on each side.' In''stallafion: Roll out ridge vent centered over the slot, and secured 6" o.c. on each side of the ridge with included 24/2" corrosion resistant galvanized roofmg nails or 1-3/4" collated corrosion resistant galvanized roofing nails (for nail guns) to hold it in place until ridge shingles can be installed. (Polyurethane sealant shall be used to seal the perimeter of the vent to the roof shingles.) Extend to the rake edge. Roll ends or cut joints shall be butted together and caulked with an approved polyarethane sealant. Ridge Shingle: Install pre -manufactured or field -cut -ridge shingles over the ridge vent in compliance with the shingle manufacturer's Notice of Acceptance (NOA) and the installation instructions. Ring shank nails shall be corrosion resistant and long enough to penetrate through the•wood deck a Innumtnn of 3116". Apply a bead of polyurethane sealant in between adjacent cap shingles to seal the caps. Net T ree Area: Refer to manufachuers published literature. LIlVIZTATIONS: 1. Refer to applicable building codes for required ventilation. 2. This acceptance is for installations over asphalt shingle roof systems only. 3. GAF Cobra® Exhaust Vent for Roof Ridge shall not be installed on roof mean heights greater than 33 feet. 4. All products listed hercia shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code, 5. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marling of the manufacturer's name or logo, city and state and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dada County product Control Seal as shown below. '. IA4t •6AUfi CO-JVIIi'. . END OF TAIS ACCEPTANCE MUSMI• ADECOUNTY NOA No.19-0123.p5 Expiraiion Dafe:11/09/23 Approval Date: 05/16/19 Page 3 of 3