HomeMy WebLinkAboutNOA- — DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADM)NISTRATION DIVISION
NOTICE OF ACCEPTANCE
GAF
I Campus Drive
Parsippany, NX 07054
---SCOPE: -------------- ------- -
MJAMI-DADS COUNTY
PRODUCT CONTROL SECTION
805 SW 26SheeY, Raom 208
M arat Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miam idade.eov/economy
This NOA is being issued under the applicable xules an$ regulations governing the use o£cola uctionmaterialS. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AM,
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AI1J may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revolve this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Cobra® Exhaust Vent for Roof Ridge,
LABELING: Each uurit, shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
.RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERNIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date maybe displayed in advertising literature. If any portion of the NOA is displayed, Then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available £or inspection at.the job site at the request of the Building Official.
This NOA renews and revises NOA No. 18-0619.02 and consists of pages 1 through 3.
The submitted documentation was reviewed by Jorge L. Acebo.
.PoIAM4DAOECOUNTY
NOA No.19-0123.05
Expiraiion Date: 11/09/23
Approval Date: 05/16/19
Page 1 of 3
ROOFING COMPONENT APPROVAL
Category: Roofih
- - - — -
Sub -Category: Ventilation
Materials:. Plastic
TRADE NAMES OF PRODUCTS Mf ANpFACTURED OR LABELED By APPLICANT;
Product Dimensions
-'GAT Cobra x aust eut 3/�1/2" x ZO'
for Roof Ridge
GAF Cobra° Exhaust Vettt
for Roof Ridge
(For nail guns)
EVIDENCE SUBMITTED;
1. Acworth, GA.
EVIDENCE SUBMITTED;
Test A2eney/Identifier
Intertek "Architectural Testing
Intertelc
M(F1MI•DAUECOUNTY
5/8" x 101/2" x 20'
Test Product
Specifiication DgscriDtion
TAS-100 Low profile attic ridge vent for installation
under ridge shingles.
Name
TAS 100(A)
ASTMD 1929
ASTM D 635
ASTM D 2843
ASTMD 1929
ASTM D 635
ASTMD 2843
TAS-100 Low profile attic ridge vent for installation
under ridge shingles.
Re ort Date
13223.01409-18 06/06/18
I3223.0240648 Rl 07/20/18
I3223.02-16648 Rl 07/20/18
I3223.02406-18 RI 07/20/18
J0478.01-10648 RO 01/08/19
J0478.01406-18RO 01/08/19
J0478.01-10648 RO 01/08/19
NOA No.19-0123.05
Expiration Date: 11/09/23
Approval Date: 05/16/19
Page 2 of 3
- - -APPROVED APPLICATIo1VS - - - -
Tradename: GAF Cobra® Exhaust Vent for Roof Ridge
System Type: Mechanical attachment of static vent over asphalt shingle roof systems only.
Cutout: Cut a 2" slot along the ridge of the roof 'by cutting 1" on each side of the ridge. Leave uncut sheathing area of 6" at each end of the ridge. Cut through sheathing only, avoiding roof hnsses.
-- --- - ---- -1tt buildings with a -ridge hoard,. cut 1-3/4" slot on each side.'
In''stallafion: Roll out ridge vent centered over the slot, and secured 6" o.c. on each side of the ridge with
included 24/2" corrosion resistant galvanized roofmg nails or 1-3/4" collated corrosion resistant
galvanized roofing nails (for nail guns) to hold it in place until ridge shingles can be installed.
(Polyurethane sealant shall be used to seal the perimeter of the vent to the roof shingles.) Extend
to the rake edge. Roll ends or cut joints shall be butted together and caulked with an approved
polyarethane sealant.
Ridge Shingle: Install pre -manufactured or field -cut -ridge shingles over the ridge vent in compliance with the
shingle manufacturer's Notice of Acceptance (NOA) and the installation instructions.
Ring shank nails shall be corrosion resistant and long enough to penetrate through the•wood deck
a Innumtnn of 3116". Apply a bead of polyurethane sealant in between adjacent cap shingles to
seal the caps.
Net T ree Area: Refer to manufachuers published literature.
LIlVIZTATIONS:
1. Refer to applicable building codes for required ventilation.
2. This acceptance is for installations over asphalt shingle roof systems only.
3. GAF Cobra® Exhaust Vent for Roof Ridge shall not be installed on roof mean heights greater than 33 feet.
4. All products listed hercia shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code,
5. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marling of the
manufacturer's name or logo, city and state and following statement: "Miami -Dade County Product Control
Approved" or the Miami -Dada County product Control Seal as shown below.
'. IA4t •6AUfi CO-JVIIi'. .
END OF TAIS ACCEPTANCE
MUSMI• ADECOUNTY
NOA No.19-0123.p5
Expiraiion Dafe:11/09/23
Approval Date: 05/16/19
Page 3 of 3