HomeMy WebLinkAboutNOA ROOF DECK PROTECTIONDEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE
GAF
1 Campus Drive
Parsipanny, NJ 07054
MIAMI-DADE COUNTY
PRO DUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.adamidade.gov/econonry
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Leak Barriers and Roof Decic Protection
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official,
This NOA revises NOA 18-0119.15 and consists of pages 1 through 8.
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No.: 18-1023.10
Expiration Date: 02/22/23
Approval Date: OS/09/19
Page 1 of 8
ROOFING COMPONENT APPROVAL
Cateeory: Roofing
Sub-Cateeory: Underlayment
Material• SBS/Polypropylene/Asphalt
SCOPE:
This approves GAF Leak Barriers and Roof Deck Protection underlayments, to be used on existing roof assemblies as
described in this Notice of Acceptance, designed to comply with the Florida Building Code and the High Velocity
Huiz•icane Zone of the Florida Building Code.
PRODUCTS DESCRIPTION:
Product
WeatherWatchm
Dimensions
36" x 50' rolls
Mineral Surfaced Leak 36" x 66.7' rolls
Barrier
Mcnnrfacturing
Location # 1, 8
Test
Specification
Product
Description
ASTM D1970 Granular surfaced modified, fiberglass reinforced,
bituminous sheet material for use as a leak barrier
underlayment hi sloped roof assemblies.
Designed as an ice &rain shield.
StormGuard� Film 36" x 66.7' rolls ASTM D1970 Modified, fiberglass reinforced, bituminous sheet
Surfaced Leak Barrier material for use as a high temperahire leak barrier
Manufacturing underlayment hr sloped roof assemblies.
Location # I, 8 Designed as an ice &rain shield.
Liberty"' SBS 5elf-
Adhering Base/Ply
Sheet
Mmaufactzrrirzg
Location # 1, 8
Deck -Armor'"' Premium
Breathable Roof Deck
Protection
Marncfacturing
Location # 7
Tiger Paw'"' Roof Deck
Protection
Maraufactzrring
Location # 2, 4, 5, 7
39-s/a" x 66' rolls ASTM D 1970 Self -adhering SBS roof membrane.
ASTM D4601
Type II
54" x 222' rolls ASTM D226 A UV -stabilized polypropylene breathable
48" x 250' rolls Type II underlayment. To be used for roof deck
48" x 100' rolls protection as an underlayment in sloped roof
assemblies.
48" x 250' rolls ASTM D226 A UV -stabilized polypropylene non -breathable
48" x 100' rolls Type II underla}nnent. To be used for roof deck protection
as an underlayment in sloped roof assemblies.
NOA No.: 18-1023.10
Mwwi•paoE couNrr Expiration Date: 02/22/23
""� � Approval Date: OS/09/19
Page 2 of 8
PRODUCTS DESCRIPTION:
Product
FeltBuster° High -
Traction Synthetic
Roofing Felt
Manufacturing
Location # 6, 7
Shingle -Mate° Roof
Deck Protection
Manufacturing
Location # 3
LibertyT" SA Glass Cap
Sheet
Manufacturing
Location # 8
GAFGLAS° Ply 4
Manufacturing
Location # 8, 9, 10
GAFGLAS° FIexP1yT"' 6
Manufacturing
Location # 8, 9, 10
Tri-Ply° Ply 4
Manufacturing
Location # 8, 9, 10
Test Product
Dimensions Specification Description
48" x 250' rolls ASTM D226 A UV -stabilized polypropylene non -breathable
Type II underlayment. To be used for roof deck protection
as an underlayment in sloped roof assemblies.
36" x 144' rolls ASTM D226 Fibergass-reinforced asphalt felt underlayment. To
Type I be used for roof deck protection as an
underlayment in sloped roof assemblies.
3V/8" x 34' rolls ASTM D1970 Granular surfaced modified, fiberglass reinforced,
ASTM D6163 self -adhering SBS roof membrane.
ASTM D7530
39.37"
(1 meter) Wide
39.37"
(1 meter) Wide
39.37"
(1 meter) Wide
MANUFACTURBVG LOCATION:
1. Mt. Vernon, IN
2. Mission, British Columbia
3. Pryor, OK
4. Qingdao, China
5. Charleston, SC
6. Spartanburg, SC
7. Dadra, India
8. Savannah, GA
9. Mobile, AL
10. Fontana, CA
ASTM D2178 Asphalt impregnated glass felt with asphalt
Type IV coating.
ASTM D2178 Asphalt impregnated glass felt with asphalt
Type VI coating.
ASTM D2178 Asphalt impregnated glass felt with asphalt
Type 1V coating.
NOA No.: 18-1023.10
Expiration Date: 02/22/23
Approval Date: OS/09/19
Page 3 of 8
EVIDENCE SUBMITTED:
Test Allency
Test Identifier
Test Name/Report
Date
hitertek Testing Services NA Ltd.
3077464-01
ASTM D1970
08/23/06
3090131
Wind Uplift and Self Sealability
08/23/06
100258583COQ-OIOA
ASTM D226 Type H
O1/I1/11
100673818COQ-003
ASTM D226 Type II
06/13/13
10157289000Q-005
ASTM D226 Type H
04/17/14
F8549.02-106-18-RO
ASTM D226Type I1
11/08/16
PRI Construction Materials
RGM-023-02-01
ASTM D4798
05/16/07
Technologies, LLC.
GAF-112-02-01
ASTM D226 Type H
03/15/06
GAF-238-02-01
ASTMD1970
03/03/10
GAF-323-02-01
ASTMD1970
11/30/11
GAF-324-02-01
ASTM D1970
11/30/11
GAF-325-02-01
ASTMD1970
11/30/11
GAF-326-02-01
ASTMD1970
11/30/11
GAF-275-02-01
ASTM D1970
11/11/10
GAF-344-02-01
ASTMD1970
04/23/12
GAF-339-02-01
ASTM D226 Type I
03/14/12
ELK-311-02-01
ASTMD1970
09/11/07
GAF-446-02-01
ASTM D226 Type I
09/26/13
GAF-518-02-01
ASTM D226 Type U
06/04/14
GAF-818-02-01
ASTM D4533
12/06/17
GAF-829-02-01
ASTM D226 Type II
01/15/18
GAF-314-02-01
ASTM D2178
07/21/11
GAF-315-02-01
ASTM D2178
07/21/11
GAF-826-02-01
ASTM D226 Type 11
ASTM D4533
07/12/18
GAF-847-02-01
ASTM D226 Type H
ASTM D4533
06/OS/18
GAF-914-02-01
ASTM D226 Type H
04/11/19
ASTM D4533
Trinity-ERD
GAF-SC13285.17-1
ASTM D1970
03/08/17
GAF-SC13285.17-3
ASTMD1970
03/08/17
GAF-SC13285.17-4
ASTMD1970
03/08/17
GAF-SC13285.17-2
ASTM D4601 Type 11
03/08/17
GAF-SC9700.08.15-R1
ASTM D2178
02/08/17
GAF-SC12915.09.17
ASTMD1970
12/11/17
GAF-SC12915.09.17
ASTMD6163
12/11/17
GAF-SC12915.09.17
ASTMD7530
12/11/17
NEMOjetc.
4S-GAF-18-001.01.19-1
ASTM D2178 Type IV
1/2/2019
4S-GAF-18-001,01.19-1
ASTM D2178 Type VI
1/2/2019
NOA No.: 18-1023.10
Expiration Date: 02/22/23
Approval Date: OS/09/19
Page 4 of 8
APPROVED ASSEMBLIES:
Deck Type 1:
Wood, non -insulated
Deck Description:
19/32"or greater plywood or wood plank
System E(1):
Anchor sheet mechanically fastened to deck, membrane adhered.
Base Sheet:
Two plies of ASTM D 226 Type I or Shingle -Mate Roof Deck Protection OR one or more plies
of ASTM D 226 Type II, Deck-Armor'l Premium Breathable Roof Deck Protection, FeltBuster®
High -Traction Synthetic Roofing Felt, or Tiger Pawl" Roof Deck Protection with a minimum 4"
side lap and a 6" end lap mechanically fastened to the deck with approved nails and tin caps 6"
o.c. at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
scam/cover tape or an approved waterproof cloth duct tape (follow the tape's manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastneners.
Membrane:
One or more plies of WeatherWatch' Mineral Surfaced Leak Barrier, StormGuard' Film
Surfaced Leak Barrier, Liberty" SA Glass Cap Sheet, or Liberty'" SBS Self -Adhering Base/Ply
Sheet membrane with a minimum 3" side lap and 6" end lap. Place the first course of membrane
parallel to the cave, rolling the membrane to obtain maximum contact. Remove the release
membrane as the membrane is applied. Vertical strapping of the roof with WeatherWatch'
Mineral Surfaced Leak Barrier, or StormGuard' Film Surfaced Leak Barrier is acceptable.
Surfacing:
Approved Roofing Assembly,
Deck Type 1: Wood, non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Membrane mechanically fastened to deck.
Separator Sheet: One or more plies of GAF GAFGLAS' Ply 4, GAFGLAS'F1exPly" 6, Rosin Paper, ASTM D
226 Type I or Type II, Shingle -Mate' Roof Deck Protection, Deck -Armor" Premium Breathable
Roof Deck Protection, FeltBuster' High -Traction Synthetic Roofing Felt, or Tiger Paw'I Roof
Deck Protection loose laid.
Membrane: One or more plies of WeatherWatch' Mineral Surfaced Leak Barrier, StormGuard' Film
Surfaced Leak Barrier, Liberty" SA Glass Cap Sheet, or Liberty' SBS Self -Adhering Base/Ply
Sheet membrane mechanically fastened with a minimum 3" side lap and a 6" end lap to deck
through the separator sheet with approved nails and tin caps 6" o.cl at the laps and two staggered
rows 12" o.c. in the field of the roll.
Surfacing: Approved Roofing Assembly,
NOA No.: 18-1023.10
Expiration Date: 02/22/23
Approval Date: OS/09/19
Page 5 of 8
Deck Type 1:
Wood, non -insulated
Deck Description:
19/32" or greater plywood or wood plank
System E(3):
Anchor sheet mechanically fastened to deck, membrane adhered.
Secondary Water
Install a minimum 4" wide WeatherWatch' Mineral Surfaced Leak Barrier, Liberty"' SBS Self -
Barrier:
Adhering Base/Ply Sheet, Liberty"SA Glass Cap Sheet, or StormGuard® Film Surfaced Leak
(Optional)
Banner membrane over the joints of the plywood roof deck prior to installation of the base sheet.
Do not overlap end or side joints. All side and end laps should be butted firmly side by side,
flush with each other but not overlapped. Do not leave the WeatherWatch® Mineral Surfaced
Leak Barrier, or StormGuard® Film Surfaced Leak Barrier membrane exposed for more than 30
days without a roof deck protection underlayment protecting the secondary water barrier.
Base Sheet:
Two plies of ASTM D 226 Type I or Shingle -Mate' Roof Deck Protection OR one or more plies
of ASTM D 226 Type II, Deck -Armor"' Premium Breathable Roof Deck Protection, FeltBuster°
High -Traction Synthetic Roofing Felt, or Tiger Pawl" Roof Deck Protection with a minimum 4"
side lap and a 6" end lap mechanically fastened to the deck with approved nails and tin caps 6"
o.c. at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape (follow the tape manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fasteners.
Surfacing:
Approved Roofing Assembly,
Deck Type 1: Wood, non -insulated
Deck Description: "/32" or greater plywood or wood plank
System E(4): Anchor sheet mechanically fastened to deck, membrane adhered.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle -Mate' Roof Deck Protection OR one or more plies
of ASTM D 226 Type H, Deck -Armor'"' Premium Breathable Roof Deck Protection, FeltBuster°
High -Traction Synthetic Roofing Felt, or Tiger Paw'" Roof Deck Protection with a minimum 4"
side lap and a 6" end lap mechanically fastened to the deck with approved nails and tin caps 6"
o.c. at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape (follow the tape's manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastieners.
Membrane: One or more plies of StormGuard® Film Surfaced Leak Barrier membrane with a minimum 4"
side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the
membrane to obtain maximum contact. Remove the release membrane as the membrane is
applied.
Surfacing: Approved for Metal roofing, Slate, and Asphalt Shingle assemblies.
NOA No.: 18-1023.10
Expiration Date: 02/22/23
Approval Date: OS/09/19
Page 6 of 8
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. WeatherWatch" Mineral Surfaced Leak Barrier, StormGuard° Film Surfaced Leak Barrier, Liberty" SBS Self -
Adhering Base/Ply Sheet, Liberty" SA Glass Cap Sheet, Shingle -Mate' Roof Deck Protection, Deck -Armor"
Premium Breathable Roof Deck Protection, FeltBuster" High -Traction Synthetic Roofing Felt, and Tiger Paw"'
Roof Deck Protection shall not be used as roof tile underlayrnent.
3. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. WeatherWatch" Mineral Surfaced Leak Barrier, StormGuard" Film Surfaced Leak
Barrier, LibertyV` SBS Self -Adhering Base/Ply Sheet, Liberty'" SA Glass Cap Sheet, Shingle -Mate° Roof Deck
Protection, Deck -Armor"" Premium Breathable Roof Deck Protection, FeltBuster° High -Traction Synthetic
Roofing Felt, and Tiger Paw" Roof Deck Protection shall be installed in strict compliance with applicable
Building Code.
4. WeatherWatch" Mineral Surfaced Leak Barrier, StormGuard" Film Surfaced Leak Barrier, Liberty"" SBS Self -
Adhering Base/Ply Sheet, Liberty"' SA Glass Cap Sheet, Shingle -Mate" Roof Deck Protection, Deck -Armor"
Premium Breathable Roof Deck Protection, FeltBuster" High -Traction Synthetic Roofing Felt, and Tiger Paw"
Roof Deck Protection membranes shall be applied to a smooth, clean and dry surface with deck free of
irregularities.
5. WeatherWatch" Mineral Surfaced Leak Barrier, StormGuard" Film Surfaced Leak Barrier, Liberty' SBS
NOA No.: 18-1023.10
Pxpiration Date: 02/22/23
Approval Date: OS/09/19
Page 7 of 8
LIMITATIONS:
10. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
11. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
12. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
13. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
MIAMI•DADE COUNTY
...%•
END OF THIS ACCEPTANCE
NOA No.: 18-1023.10
Expiration Date: 02/22/23