HomeMy WebLinkAboutNOA-SHINGLESMUM-DADE COUNTY
MIAMl•DADE PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY ANp ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.mimnidade.eoy/economy
GAF
I Campus Drive
Parsippany, NJ 07054
SCOPE:
This NOA is being issued lender the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revolve, modify, or suspend the use of such product or material within their jurisdiction, RBR reserves the right to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, .and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Timberline HD°, Timberline' Natural Shadow°, Timberline' NS, Timberline' American
Harvest', Timberline' AH, Timberline' HDZTM, Timberline' CS and Fortitude' Shingles
LABELINGt Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION
of this NOA will occur after the expiration date or if there has been a revision or change in tine
materials, use, and/or manufachtre of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISE ME,
NTt The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date maybe displayed iu advertishng literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTI®N: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Offfcial.
This NOA renews and revises NOA # 16-0811.11 and consists of pages 1 through 7.
The submitted documentation was reviewed by Fred4y ,S`emino Wk
APPROVED
NOA No.: 19-0312.04
Expiration Date: 02/21/22
Approval Date: 01/09/20
Page 1 oI7
1 i�- . 1 1
MIAMMADE PRODUCT CONTROL SECTION
:1 /:
1 1 �f.REGULATORY-ANDECONOMIRE
BOARD l CODE ADMINISTRATIONDIVISION • 1
NOTICE OFACCEPTANCEW .
GAF
I Campus Drive
Parsippany, NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revolve, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, .and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
I)ESCRTPTION: GAF Timberline IID°, Timberline' Natural Shadow°, Timberline° NS, Timberline° American
Harvest', Timberline' AH, Timberline' HDZTM, Timberline' CS and Fortitude' Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable bunduig code negafvely affecting the performance of this product.
T
ERNTINATI®N of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufachire of the product or process. Misuse ofthis NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT:
The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date maybe displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its enth ety.
INSPECTION*
A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Offivial.
This NOA renews and revises NOA # 16-0811.11 and consists of pages 1 through 7.
The submitted documentation was reviewed by Fred4y Semino 0
NOA No.: 19-0312.04
Expiration Date: 02/21/22
Approval Date: 01/0Mu
Page 1 of 7
Category:
Mofmg
Sub -Category:
Asphalt Shingles
Materials:
Laminate
Deck Tyne:
Wood
SCOPE
This approves GAF Timberline HD', Timberline® Natural Shadown, Timberline NS®, Timberline American®
Harvest", Timberline AIP, Timberline® HDZTM, Timberline CS' and Fortitudgm Shingles as manufactured by
GAF as described in this Notice of Acceptance.
IDRODUCT DESCRIPTI®N
Product
GAF Timberline HDe
Manufacturing
Locations 41, 2, 3, 4, 5, 6, 7
GAF Timberline° Natural
Shadow® and Timberline° NS
Manufacturing
Locations 41, 2, 3, 4, 5, 6, 7
GAF Timberline' American
Harvest°
Manufacturing
Locations 02, 4, 6, 9
GAF TimberlineeAH
Manufacturing
GAF Timberline° $DZ`"`
Manufacturing
Tnrntinns 91. 2. 3. 4. 5. 6. 7
GAF Fortitudem
Manufacturing
Location #4
GAF Timberline® CS
Manufacturing
Location #9
APPROYE�
Dimensions Test Product Description
Specifications
13 '/4"x 39 % TAS 110 Fiberglass reinforced heavy weight asphalt roof
shingle, with a laminate profile
13 r/a •x 39 s/s" TAS 110 Fiberglass reinforced heavy weight asphalt roof
shingle, with a laminate profile
13'/a"x 39 3/s � TAS 110 Fiberglass reinforced heavy weight asphalt roof
shingle, with a laminate profile
13 r/a x 39'/a' TAS 110 Fiberglass reinforced heavy weight asphalt roof
shingle, with a laminate profile
13 r/a"x 39 3/s • TAS 110 Fiberglass reinforced heavy weight asphalt roo£
shingle, with a laminate profile
13 �/4"x 39 3/s' TAS 110 Fiberglass reinfbrced heavy weight asphalt roof
shingle, with a laminate profile
13 '/a x 39 3/g TAS 110 Fiberglass reinforced heavy weight asphalt roof
shingle, with a laminate profile
NOA No.: 19-0312.04
Expiration Date: 02/21/22
Approval Date: Ol/09/20
Page 2 of 7
1.
Tampa, FL
2.
Michigan City, IN
3.
Baltimore, MD
4.
Myerstown, PA
5.
Ennis, TX
6.
Tuscaloosa, AL
7.
Dallas, TX
8.
Shafter, CA
9.
Fontana, CA
NOA No.:19-0312.04
Expiration Date: 02/21/22
Approval Date: Ol/09/20
Page 3 of 7
E+ VIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
Underwriters Laboratories, LLC
ASTM
D3462
4788932264
12/13/19
Underwriters Laboratories, LLC
ASTM
D3462
4788717529
01/31/19
Underwriters Laboratories, LLC
ASTM
D3462
4787344101
07/25/16
Underwriters Laboratories, Inc.
ASTM
D3462
h ICA48924
10/22/11
Underwriters Laboratories, Inc
ASTM
D3462
1 OCA21994
04/22/11
Underwriters Laboratories, Inc
ASTM
D3462
10CA28717
07/26/11
Underwriters Laboratories, Inc.
ASTM
D3462
05CA47541
11/10/06
Underwriters Laboratories, Inc.
ASTM
D3462
06CA31580
11/30/06
PRI Asphalt Technologies, Inc.
ASTM
D3462
GAF40142-02
11/02/05
Underwriters Laboratories, Inc.
ASTM
D3462
06NIC05159
08/09/06
PRI Asphalt Technologies, Inc.
ASTM
D3462
GAF-098-02-02
11/08/05
Underwriters Laboratories, Inc.
ASTM
D3462
02NK41809
08/11/02
Underwriters Laboratories, hie, Center for
ASTM D3462ASTM
03NIU6444257989
10/17/03
Applied Engineering
D3462
05/13/97
Underwriters Laboratories, LLC
TAS
107
4789225984
11/1/19
Underwriters Laboratories, LLC
TAS
107
4788717529
01/31/19
Underwriters Laboratories, Inc.
TAS
107
OINIC45803
04/13/94
Underwriters Laboratories, Inc.
TAS
107
06NK05159
08/09/06
Underwriters Laboratories, Inc.
TAS
107
04NK04273
02/20/04
Underwriters Laboratories, Inc.
TAS
107
05CA42840
11/11/05
Underwriters Laboratories, Inc.
TAS
107
02NK41811
11/11/02
Underwriters Laboratories, Inc.
TAS
1.07
03CA35209
10/17/03
Underwriters Laboratories, Inc.
TAS
107
04CA13850
08/30/04
Center for Applied Engineering
TAS
100
257989
04/01/97
PRI Asphalt Technologies, Inc.
TAS
100
GAF,912-02-01
12/17/18
PRI Asphalt Technologies, Inc.
TAS
100
GAF-044-0241
01/13/04
PRI Asphalt Technologies, Inc.
TAS
100
GAF-098-02-01
11/08/05
PRI Asphalt Technologies, Inc.
TAS
100
GAF-101-02-01
11/09/05
PRI Asphalt Technologies, Inc.
TAS
100
GAF-116-02-02
03/23/06
PRI Asphalt Technologies, Inc.
TAS-100
ELK-083-02-01
10/16/02
ELK-084-02-01
10/15/02
ELK-085-02-01
10/14/02
ELK-086-02-01
10/24/02
ELK-087-02-01
10/21/02
ELK-088-02-01
10/16/02
ELK-107-02-01
10/09/03
ELKA O&02-01
10/09/03
ELK-109-0241
10/09/03
NOA No.: 19-0312.04
Expiration Date: 02/21/22
Approval Date: 01/09/20
Page 4 of 7
LEMTATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61020-3 of the Florida Administrative Code,
INSTALLATION
1. Shingles shall be installed incompliance with RoofmgApplication Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail'A', attached.
5. Nailing shall be in compliance with Detail 'B', attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade.
County Product Control Seal as shown below.
BUILDING PERNIIT REQUIItENiENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 19-0312.04
Expiration Date: 02/21/22
Approval Date: Oi/09/20
Page 5 of 7
DETAIL A
COURSE LAYOUT
APPROVED J
Exposure
NOA No.: 19-0312.04
Expiration Date: 02/21/22
Approval Date: 01/09/20
Page 6 of 7
DETAiLB
OvERALL MwNsioNs Am)' •t:
(1mj
14-1/21'-17-1/2" 14-1/21' �Zl/2"
(368-446mm) (368.4 6mm)
6'-1/2"-9-1/2" 6-112"-9-1/2" ailguldeline
— lil rf (tes-zsfmm7 (166. zatmm)
/ `-Y (146mm-159mm)
@a7 m) 10 2 IZ„ —� -!— —S- i-- from bottom of shingle
7 elf seal
adhesive
on back
ENHANCED NAILING PATTERN - six nails per shingle*
'required by some [ota] codes and required for enhanced wind covetage on certain products.
See limited warranty for details,
These shingles MUST be nailed a nominal 6" {152mm) from bottom of
of shingle, above the cut outs, as shown. Nails must not be exposed.
®VERALL DIMENSIONS AND NAILING PATTERN
YOR TIIVIBERLINEIIHDZmg TBoERLINE8 CS, TjmBERLINEmAH, AND
FORTITUDE'
E1iD OF THIS ACCEPTANCE
��APPROYED J
TARGET
IAId. ZONE
13116" - M/80
3 mm -194 mm)
NOA No.: 19-0312.04
Expiration Date: 02/21/22
Approval Date: 01/09/20
Page 7 of 7