Loading...
HomeMy WebLinkAboutHomes by Aburton-ssUES Project No: Workorder No: Report Date: 3360.1900044.0000 242975-1 08/18/2021 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:HOMES BY ABURTON, LLC UES Technician:Mark Rogers RA Construction of the Treasure Coast Attn: Don Warburton Stuart, FL 34994 Date Tested:08/18/2021 Project:HOMES BY ABURTON LLC Various Locations, , TBD County, FL Type of Test: Area Tested: 700 Winter Creek Road - House Pad Field:ASTM D-6938 Nuclear Gauge Method Material:Backfill Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Final Grade The tests below meet the 95% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 Northeast corner of pad 0-1 ft 111.4 11.2 108.9 11.0 98 Pass 2 Southwest corner of pad 0-1 ft 111.4 11.2 109.3 11.3 98 Pass 3 Center of pad 0-1 ft 111.4 11.2 108.8 11.1 98 Pass Remarks:Permit: 21060825 Reviewed By GFA International, Inc FBPE Registry No.4930 Paul H. Danforth Regional VP STATE OF FLORIDA Professional Engineer No. 44653 This item has been digitally signed and sealed by Paul H. Danforth on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1