In-Place Density Test Report
Client:HOMES BY ABURTON, LLC UES Technician:Mark Rogers
RA Construction of the Treasure Coast Attn: Don Warburton
Stuart, FL 34994
Date Tested:08/18/2021
Project:HOMES BY ABURTON LLC
Various Locations, , TBD County, FL
Type of Test:
Area Tested: 700 Winter Creek Road - House
Pad
Field:ASTM D-6938 Nuclear Gauge Method
Material:Backfill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Final Grade
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 Northeast corner of pad 0-1 ft 111.4 11.2 108.9 11.0 98 Pass
2 Southwest corner of pad 0-1 ft 111.4 11.2 109.3 11.3 98 Pass
3 Center of pad 0-1 ft 111.4 11.2 108.8 11.1 98 Pass
Remarks:Permit: 21060825
Reviewed By
GFA International, Inc
FBPE Registry No.4930
Paul H. Danforth
Regional VP
STATE OF FLORIDA
Professional Engineer No. 44653
This item has been digitally signed and sealed by Paul H. Danforth
on the date adjacent to the seal. Printed copies of this document are
not considered signed and sealed and the signature must be
verified on any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1