HomeMy WebLinkAboutAPPROVED ENERGY LOT 27(1)FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name; KHOV-LELIA
Builder Name: KHOVNANAIN HOMES
Street: 5118 ARMINA PLACE
Permit Office:
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: LELIA MODEL LOT 27 @ WATERSTONE
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2
1. New construction or existing New (From Plans)
10. Wall Type$1844.9 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1508.90 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=11.0 336.00 ft2
c. NIA
R= ft2
4. Number of Bedrooms 4
d. NIA
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1917.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1917.00 ft2
6. Conditioned floor area above grade (ft2) 1917
b. NIA
R= ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft2
7. Windows(201.8 sgft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.28 159.83 ft2
a. Sup: Attic, Ret: LAUNDRY, AH: LAUNDRY
6 250
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.55 42.00 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.34
a. Central Unit
35.2 SEER:16.00
c. U-Factor: NIA ft2
SHGC:
Area Weighted Average Overhang Depth: 1.570 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.308
a. Electric Strip Heat
32.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) NIA ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (1917.1 sgft_) Insulation Area
EF: 0.950
a_ Slab -On -Grade Edge Insulation R=0.0 1917.10 ft2
b. Conservation features
b. NIA R= ft2
None
c. NIA R= ft2
16. Credits
Pstat
Total Proposed Modified
Glass/Floor Area: 0.105
Loads: 59.66
PASS
Total Baseline Loads: 61.14
1 hereby certify that the plans and pecifications covered by
Review of the plans and
'TIRE S3 4�h
this calculation are in compliance Wth the Florida E r ergy
specifications covered by this
Code.
calculation indicates compliance,,,,''
c
with the Florida Energy Code.
I-. I", }T ,`1`',yyiti y
PREPARED BY.
Before construction is completed
u = �
DATE:
this building will be inspected for
compliance with Section 553,908
* h
I hereby certify that this building, as designed, is in compliance
Florida Statutes.,
with the Florida Energy Code.
�' D
WE
OWNERIAGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
7/13/2021 8:07 AM EnergyGauge( USA 7.0,00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Title:
KHOV-LELIA
Building Type:
User
Owner Name:
LELIA MODEL LOT 27 @ WA
# of Units:
1
Builder Name:
KHOVNANAIN HOMES
Permit Office:
Jurisdiction:
Family Type:
Detached
New/Existing:
New (From Plans)
Comment:
PROJECT
Bedrooms:
4
Conditioned Area:
1917
Total Stories:
1
Worst Case:
No
Rotate Angle:
0
Cross Ventilation:
No
Whole House Fan:
No
CLIMATE
Address Type:
Street Address
Lot #
Block/Subdivision:
PlatBook:
Street:
5118 ARMINA PLACE
County:
St. Lucie
City, State, Zip:
FORT PIERCE,
FL,
%
Design Temp
Int Design Temp
Heating
Design Daily Temp
V
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days
Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area Volume
1
Entire House
1917 16614.7
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished
Cooled
Heated
1
EXT STE LIV PLUS
199 1765.1
No
0
4
1
No
Yes
Yes
2
WIC STE PLS BED
25 220
No
0
1
No
Yes
Yes
3
EX STE PLUS BED
132 1161.6
No
0
1
No
Yes
Yes
4
EX STE BATH
54 475.2
No
0
1
No
Yes
Yes
5
FOYER
81 712.8
No
0
1
No
Yes
Yes
6
HALL BATH
54 475.2
No
0
1
No
Yes
Yes
7
LAUNDRY
77 677.6
No
0
1
No
Yes
Yes
8
BED 3
126 1108,8
No
1
1
No
Yes
Yes
9
BED 2
126 1109
No
1
1
No
Yes
Yes
10
KIT GREAT RM DI
672 5644.8
No
0
1
No
Yes
Yes
11
M BATH
95 836
No
0
1
No
Yes
Yes
12
MASTER SUITE
210 1848
No
2
1
No
Yes
Yes
13
MASTER WIC
66 580.8
No
0
1
No
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value Tile Wood
Carpet
1 Slab -Orr -Grade Edge Insulatio
EXT STE LIV PL 46 ft
0
199.3 ft2
----
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC STE PLS BE 4.5 ft
0
25 ft2
--__
0 1
0
3 Slab -On -Grade Edge Insulatio
EX STE PLUS B 8.5 ft
0
132 ft2
_---
0 1
0
4 Slab -On -Grade Edge Insulatio
EX STE BATH 1 ft
0
54 ft2
----
1 0
0
7/13/2021 8:07 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulatio
FOYER 19 ft
0
81.3 ft2
----
1
0
0
6 Slab -On -Grade Edge Insulatio
HALL BATH 1 ft
0
54 ft2
----
1
0
0
7 Slab -On -Grade Edge Insulatio
LAUNDRY 7.5 ft
0
77 ft2
----
1
0
0
8 Slab -On -Grade Edge Insulatio
BED 3 22.5 ft
0
126 ft2
0
1
----
0
9Slab-On-Grade Edge Insulatio
BED 2 12.5 ft
0
126 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio
KIT GREAT RM 43.5 ft
0
672 ft2
----
1
0
0
11SIab-On-Grade Edge Insulatio,
M BATH 9 ft
0
94.5 ft2
_---
1
0
0
12SIab-On-Grade Edge Insulatio
MASTER SUITE 28 ft
0
210 ft2
-_--
0
1
0
13SIab-On-Grade Edge Insulatio
MASTER WIC 6 ft
0
66 ft2
----
0
1
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
li # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Composition shingles 2076 ft2
0 ft2 Medium
N
0.9
No 0.9
No 0
22.6
ATTIC
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1917 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
EXT STE LIV PL
30
Blown
199 ft2
0.1
Wood
2 Under Attic (Vented)
WIC STE PLS BE
30
Blown
25 ft2
0.1
Wood
3 Under Attic (Vented)
EX STE PLUS B
30
Blown
132 ft2
0.1
Wood
4 Under Attic (Vented)
EX STE BATH
30
Blown
54 ft2
0.1
Wood
5 Under Attic (Vented)
FOYER
30
Blown
81 ft2
0.1
Wood
6 Under Attic (Vented)
HALL BATH
30
Blown
54 ft2
0.1
Wood
7 Under Attic (Vented)
LAUNDRY
30
Blown
77 ft2
0.1
Wood
8 Under Attic (Vented)
BED 3
30
Blown
126 ft2
0.1
Wood
9 Under Attic (Vented)
BED 2
30
Biown
126 ft2
0.1
Wood
10 Under Attic (Vented)
KIT GREAT RM
30
Blown
672 ft2
0.1
Wood
11 Under Attic (Vented)
M BATH
30
Blown
95 ft2
0.1
Wood
12 Under Attic (Vented)
MASTER SUITE
30
Blown
210 ft2
0.1
Wood
13 Under Attic (Vented)
MASTER WIC
30
Blown
66 ft2
0.1
Wood
7/13/2021 8:07 AM EnergyGaugea USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space
CavV.ity Width
Height
Sheathing Framing
Solar
Below
1
SE
Exterior
Concrete Block - Int InsEiKT STE LIV
4.1 11
7
9
4
108.1
0
ft2
0
0
0.5
0
2
SW
Exterior
Concrete Block - Int InsrdKT STE LIV
4.1 15
4
10
0
153.3 ft2
0
0
0.5
0
3
SW
Exterior
Concrete Block - Int InsiEX STE PLU
4.1 7
8
10
0
76.7 ft2
0
0
0.6
0
z 4
SE
Exterior
Concrete Block - Int Insul FOYER
4.1 6
4
9
4
59.1 ft2
0
0
0.5
0
5
SW
Exterior
Concrete Block - Int Insul FOYER
4.1 11
4
10
0
113.3 ft2
0
0
0.5
0
z 6
NE
Exterior
Concrete Block - Int Insul BED 3
4.1 11
7
9
4
108.1 ft2
0
0
0.5
0
7
NE
Exterior
Concrete Block- Int Insul BED 2
4.1 11
7
9
4
108.1 ft2
0
0
0.5
0
8
SW
Exterior
Concrete Block - Int InsLItlT GREAT
4.1 25
2
10
0
251.7 ft2
0
0
0.5
0
9
NW
Exterior
Concrete Block - Int InsLKIT GREAT
4.1 15
1
9
4
140.8 ftz
0
0
0.5
0
10
NE
Exterior
Concrete Block - Int Insul M BATH
4.1 8
9
9
4
81.7 ft2
0
0
0.5
0
11
NE
Exterior
Concrete Block - Int InsMASTER SUI
4.1 14
1
9
4
131.4 ft2
0
0
0.5
0
y 12
NW
Exterior
Concrete Block - Int InsMASTER SUI
4.1 13
1
9
4
122.1 ft2
0
0
0.5
0
13
NW
Exterior
Concrete Block - Int InsdVIASTER WI
4.1 5
10
9
4
54.4 ft2
0
0
0.5
0
14
NW
Garage
Frame - Wood KIT GREAT
11 36
0
9
4
336.0 ft2
0
0
0.5
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
SW
Insulated EXT STE LIV
None
.39
3
2
6 8
21.1 ft2
2
SW
Insulated EXT STE LIV
None
.39
3
2
6 8
21.1 ft2
3
NW
Woad KIT GREAT
None
.39
3
2
6 B
21.1 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
1/
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screeninc
1
SE 1
Metal Double (Tinted) Yes
0.28 0.3
N
22.9 ft2
1 ft 0 in
1 ft 0 in
None
None
2
SW 3
Metal Double (Tinted) Yes
0.28 0.3
N
23.0 ft2
6 ft 0 in
1 ft 0 in
None
None
3
SW 5
Metal Double (Tinted) Yes
0.28 0.3
N
15.0 W
1 ft 0 in
1 ft 0 in
None
None
4
NE 6
Metal Double (Tinted) Yes
0.28 0.3
N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
5
NE 7
Metal Double (Tinted) Yes
0.28 0.3
N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
6
SW 8
Metal Double (Tinted) Yes
0.28 0.3
N
23.0 ft2
1 ft 0 in
1 ft 0 in
None
None
7
NW 9
Metal Double (Tinted) Yes
0.28 0.3
N
23.0 ft2
1 ft 0 in
1 ft 0 in
None
None
8
NW 9
Metal Double (Tinted) Yes
0.55 0.34
N
42.0 ft2
1 ft 0 in
1 ft 0 in
None
None
9
NW 12
Metal Double (Tinted) Yes
0.28 0.3
N
22.9 ft2
1 ft 0 in
1 ft 0 in
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
380 ft2 380 ft2
64 ft
8 #t
1
7/1312021 8:07 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPI IT Al IMMARY rw;z `L[l ICT DCDr%DT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000385
1938.4 106.35 199.65 .1304
7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Strip Heat/
None
COPA 32 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 16 35.2 kBtulhr cfm
0.81 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.95 50 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
--- Return ---- Air CFM 25 CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type Handler TOT OUT
QN RLF
Heat Cool
1 Attic 6 250 ft2
LAUNDRY
1 ft2 Default Leakage LAUNDRY (Default) (Default)
1 1
TEMPERATURES
Prograrnable Thermostat: Y
Ceiling Fans_
Coolin [f Ii Jan [ ]Feb [j ]]Mar
Apr
Ma Jun Jul Aug Se
Oct Nov
Dec
Heating fXl Jan 4X] Feb [X] Mar
Ventin [[[[ III Jan ] Feb [[X]] Mar
l Apr
[X A r
MaYy Jun JulAuf Sep
Ma Jun Jul Aug [ Se
rj rl ri
Oct �(� Nov
Oct [[X Nov
lX Dec
[ Dec
7113/2021 8:07 AM EnergyGaugeQD USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
78
80 80
80
80
78
78
78
78
78 78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68 68
58
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibslsq.ft.
0 ft2
Oft
0.3
BED 2
Default(8 Ibslsq.ft.
ft2
ft
0.3
WIC BED 2
Default(8 Ibslsq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibslsq.ft.
ft2
ft
0.3
KITCHEN DINING
Default(8 Ibslsq.ft.
ft2
ft
0.3
GREAT ROOM
Default(8 Ibslsq. ft.
ft2
ft
0.3
FOYER
Default(8 Ibslsq.ft,
ft2
ft
0.3
LAUNDRY
Default(8 Ibslsq.ft.
ft2
ft
0,3
M WIC
Default(8 Ibslsq.ft.
ft2
ft
0.3
M TIOLET
Default(8 Ibslsq.ft,
ft2
ft
0.3
M BATH
Default(8 Ibslsq.ft.
ft2
ft
0.3
MASTER SUITE
7/13/2021 8:07 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX` = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows- Description
a. U-Factor: Dbl, U=0.28
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.34
c. U-Factor: NIA
SHGC:
d. U-Factor: NIA
SHGC:
Area Weighted Average Overhang Depth
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): NIA
SHGC(AVG): NIA
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. NIA
c. NIA
5118 ARMINA PLACE, FORT PIERCE, FL,
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1508.90 ft2
b. Frame - Wood, Adjacent
R=11.0
336.00 ft2
1
c. NIA
R=
ft2
4
d. NIA
R=
ft2
No
11. Ceiling Type and insulation level
Insulation
Area
a- Under Attic (Vented)
R=30.0
1917.00 ft2
1917
b. NIA
R=
ft2
Area
c. NIA
R=
ft2
159.83 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: LAUNDRY, AH: LAUNDRY
6 250
42.00 ft2
13. Cooling systems
kBtulhr
Efficiency
ft2
a. Central Unit
35.2
SEER:16.00
ft2
1.570 ft.
0.308
Area
ft2
Insulation Area
R=0.0 1917.10 ft2
R= ft2
R= ft2
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
kBtulhr Efficiency
32.0 COP:1.00
Cap: 50 gallons
EF: 0.95
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
711312021 &07 AM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1