Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED WS 27 - Arch Plans ss(1)
BUILDING DATA 0 z ABBREVIATIONS AB ANCHOR BOLT MAS MASONRY A.F.F. ABOVE FINISH FLOOR MAT MATERIAL ADJ. ADJUSTABLE MAX MAXIMUM ALUM. ALUMINUM MC MEDICINE CABINET ANCH ANCHOR MECH MECHANICAL 4 ANGLE MIN MINIMUM @ AT MIR MIRROR ML MICRO LAM BD. BOARD M.O. MASONRY OPENING BF BI-FOLD MTL METAL BLDG. BUILDING BM. BEAM N.I.C. NOT IN CONTRACT BLKG BLOCKING (NTS) NOT TO SCALE B.O. BOTTOM OF B.P. BI-PASS DOOR OBS OBSCURED BRG. BEARING O.C. ON CENTER BRK. BRICK OHGD OVERHEAD GARAGE DOOR OPER OPERATOR C.J. CONTROL JOINT OPNG OPENING q CENTER LINE OPT OPTIONAL CMU CONCRETE MASONRY UNIT OSB ORIENTED STRAND BOARD COL. COLUMN OZ OUNCE CONC. CONCRETE 1/R ONE ROD COND. CONDITION 1/S ONE SHELF CONT. CONTINUOUS CANT. CANTILEVER PC PRECAST CLG. CEILING PDS PULL -DOWN STAIR CM CROWN MOLDING PKT POCKET DOOR CR CHAIR RAIL PNL PANEL PLYWD PLYWOOD D DRYER PREFAB PREFABRICATED d PENNY PR PAIR DBL. DOUBLE PROJ PROJECTED DIA. DIAMETER PSI POUNDS PER SQUARE INCH DIR. DIRECTION PSF POUNDS PRE SQUARE FOOT DN DOWN P.T. PRESSURE TREATED DR DOOR DW DISH WASHER QUAD QUADRUPLE DWG DRAWING D.S. DOWNSPOUT REF REFRIGERATOR DTL DETAIL REINF REINFORCED REQ'D REQUIRED EA. EACH RNG RANGE E.J. EXPANSION JOINT R.O. ROUGH OPENING ELEC. ELECTRICAL R RISER ELEV ELEVATION RND ROUND EQ. EQUAL R&S ROD AND SHELF EQUIP. EQUIPMENT EXP EXPANSION SC SOLID CORE EXT. EXTERIOR SCHEM SCHEMATIC EE EACH END SHLF SHELF SHT SHEET FD FLOOR DRAIN SHWR SHOWER FIN. FINISHED FLOOR SIM SIMILAR FND. FOUNDATION SH SINGLE HUNG FLR. FLOOR S.S. STAINLESS STEEL FP FIREPLACE STL STEEL FIR FIRE RATED STRUCT STRUCTURAL FXD FIXED SUSP SUSPENSION FRM FRAME SGD SLIDING GLASS DOOR FTG FOOTING SQ SQUARE GA. GAUGE T TREAD GALV. GALVANIZED TB TOWEL BAR GC GENERAL CONTRACTOR T&G TONGUE AND GROOVE GEN GENERAL TEMP TEMPERED GYP. GYPSUM T.O. TOP OF GL GLUE LAM TR TOWEL ROD GLS GLASS TRPL TRIPLE TYP TYPICAL H HIGH HC HOLLOW CORE U.N.O. UNLESS NOTED OTHERWISE VERT VERTICAL HGT. HEIGHT V.L.I.F. VERIFY LOCATION IN FIELD HDR. HEADER HB HOSE BIBB W WASHER HORIZ. HORIZONTAL W/ WITH INSUL. INSULATION WC WATER CLOSET INT. INTERIOR WD WOODWWM WELD WIRE MESH LAV. LAVATORY WDW WINDOW LT LAUNDRY TUB TM vn C9 Tj I c9n Coils p�»res 90 Matawan Road LLC Matawan, NJ 07747 (732) 383-2200 Dawn Korbelak, RA,AIA,NCARB Digitally signed by Dawn Korbelak, RA,AIA,NCARB Date: 2021,07,28 05:33:30 -04'00 1 LELIA m ESP TERMITE TREATMENT TERMITE PROTECTION SHALL BE PROVIDED BY DOMINION 2L TERMITICIDE/INSECTICIDE. UPON COMPLETION OF THE APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." ELEVATION "A" 5118 ARMINA PLACE FT. PIERCE, FL 34951 LOT 027 AREA CALC: ELEVATION "A" 1 ST FLR/TOTAL A/C 1917 SQ. FT. TOTAL VOLUME 16,614 CU. FT. ENTRY 84 SQ. FT. GARAGE 380 SQ. FT. TOTAL UR 2381 SQ. FT. THESE PLANS HAVE BEEN PREPARED TO MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, 7th Edition (2020) RESIDENTIAL w/ APPLICABLE SUPPLEMENTS OCCUPANCY: R3 BUILDING TYPE: VB SPRINKLED: NO FLOOD ZONE: 'X' TERMITE PROBABILITY: VERY HEAVY DRAWING INDEX CS1 CS2 A1.1 A2.1 A2.2 A3.1 A5.1 A5.2 WP1 E1.1 P1.1 S-0.0 F-1.0 F-2.0 S-1.3 SD-1 SD-2 PBSB-1 COVERSHEET & BUILDING DATA GENERAL NOTES FIRST FLOOR PLAN FRONT & REAR ELEVATIONS SIDE ELEVATIONS ROOF PLAN BUILDING SECTIONS TYPICAL WALL SECTIONS WATERPROOFING DETAILS FIRST FLOOR ELECTRICAL PLAN SLAB PENETRATION PLAN STRUCTURAL NOTES SLAB PLAN BLOCK PLAN ROOF FRAMING PLAN FOUNDATION DETAILS STRUCTURAL DETAILS STRUCTURAL DETAILS ZONING REVIEWED U) Z W x 2 a O H W W 2 N w 0 u 2!� Q H Q z w F_ z (D m O z Q 0 06 z a J a_ w U) w _ z_ _ w a_ O cr IL w O 0 z a _ C7 } �P�•oGGi0 ko'?�i0 0 z' AR94880 commum: WATERSTONE PLAN # 6076 RELEASED: 7/30/21 SHEET GS I J U) w m IL x w w 2E O _ z a z a z 0 NA GENERAL CONSTRUCTION NOTES DWELLING -GARAGE SEPARATION: R308.4.3 GLAZING IN WINDOWS R311.7.8.2 CONTINUITY ROOF ASSEMBLIES: GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING CONDITIONS HANDRAILS FOR STAIRWAYS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT, FROM A R302.5 DWELLING -GARAGE OPENING AND PENETRATION PROTECTION SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION: POINT DIRECTLY ABOVE THE TOP RISER OF THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWEST RISER R903.2 FLASHING OPENINGS AND PENETRATIONS THROUGH THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM OF THE FLIGHT. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR FLASHINGS SHALL BE USED TO SEAL ROOFING SYSTEMS, WHERE THE SYSTEM IS INTERRUPTED OR 1. THE EXPOSED AREA OF AN INDIVIDUAL PANE IS LARGER THAN 9 SQUARE FEET, SAFETY TERMINALS. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LESS THAN 11/2 TERMINATED AND SHALL BE INSTALLED IN A MANNER THAT PREVENTS MOISTURE FROM ENTERING THE WALL THE GARAGE SHALL BE IN ACCORDANCE WITH SECTIONS R302.5.1 THROUGH R302.5.3. 2. THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 18 INCHES ABOVE THE FLOOR, INCHES (38 MM) BETWEEN THE WALL AND THE HANDRAILS. AND ROOF THROUGH JOINTS IN COPINGS, THROUGH MOISTURE PERMEABLE MATERIALS AND AT 3. THE TOP EDGE OF THE GLAZING IS MORE THAN 36 INCHES ABOVE THE FLOOR; AND INTERSECTIONS WITH PARAPET WALLS AND OTHER PENETRATIONS THROUGH THE ROOF PLANE. R302.5.1 OPENING PROTECTION 4. ONE OR MORE WALKING SURFACES ARE WITHIN 36 INCHES, EXCEPTIONS: OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES SHALL 5. MEASURED HORIZONTALLY AND IN A STRAIGHT LINE, OF THE GLAZING. 1. HANDRAILS SHALL BE PERMITTED TO BE INTERRUPTED BY A NEWEL POST AT THE TURN. R903.2.1 LOCATIONS NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED 2THE USE OF A VOLUTE, TURNOUT, STARTING EASING OR STARTING NEWEL SHALL BE ALLOWED . FLASHINGS SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, WHEREVER THERE IS A CHANGE IN WITH SOLID WOOD DOORS NOT LESS THAN 13/8 INCHES (35 MM) IN THICKNESS, SOLID OR R308.4.5 GLAZING AND WET SURFACES OVER THE LOWEST TREAD. ROOF SLOPE OR DIRECTION AND AROUND ROOF OPENINGS. WHERE FLASHING IS OF METAL, THE METAL ONEYCOMBCORE STEEL DOORS NOT LESS THAN 13/8 INCHES (35 MM) THICK, OR 20 MINUTE FIRE RATED GLAZING IN WALLSENCLOSURES OR FENCES CONTAINING OR FACING HOT TUBSSPASWHIRLPOOLS SHALL CORROSION RESISTANT WITH A THICKNESS OF NOT LESS THAN PROVIDED IN TABLE R903.2.1 OR IN D DOORS. , , , , COMPLIANCE WITH RAS 111. SAUNAS, STEAM ROOMS, BATHTUBS, SHOWERS AND INDOOR OR OUTDOOR SWIMMING POOLS WHERE R311.7.8.3 GRIP -SIZE EXCEPTION: FLASHING IS NOT REQUIRED AT HIP AND RIDGE JUNCTIONS. R302.6 DWELLING -GARAGE FIRE SEPARATION THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE REQUIRED HANDRAILS SHALL BE OF ONE OF THE FOLLOWING TYPES OR PROVIDE EQUIVALENT THE GARAGE SHALL BE SEPARATED AS REQUIRED BY TABLE R302.6. OPENINGS IN GARAGE WALLS SHALL ANY STANDING OR WALKING SURFACE SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION. THIS GRASPABILITY. R903.2.3 MEMBRANE FLASHINGS COMPLY WITH SECTION R302.5. ATTACHMENT OF GYPSUM BOARD SHALL COMPLY WITH TABLE R702.3.5. SHALL APPLY TO SINGLE GLAZING AND EACH PANE IN MULTIPLE GLAZING. ALL MEMBRANE FLASHING SHALL BE INSTALLED ACCORDING TO THE ROOF ASSEMBLY MANUFACTURER'S 1. TYPE I. HANDRAILS WITH A CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF NOT PUBLISHED LITERATURE. THE WALL SEPARATION PROVISIONS OF TABLE R302.6 SHALL NOT APPLY TO GARAGE WALLS THAT ARE EXCEPTION: GLAZING THAT IS MORE THAN 60 INCHES, MEASURED HORIZONTALLY AND IN A STRAIGHT LESS THAN 11/4 INCHES (32 MM) AND NOT GREATER THAN 2 INCHES (51 MM). IF THE HANDRAIL IS NOT PERPENDICULAR TO THE ADJACENT DWELLING UNIT WALL. LINE, FROM THE WATER'S EDGE OF A BATHTUB, HOT TUB, SPA, WHIRLPOOL OR SWIMMING POOL OR FROM CIRCULAR, IT SHALL HAVE A PERIMETER DIMENSION OF NOT LESS THAN 4 INCHES (102 MM) AND NOT R905.1.1.1 UNDERLAYMENT FOR ASPHALT, METAL, MINERAL SURFACED, SLATE AND SLATE -TYPE ROOF THE EDGE OF A SHOWER, SAUNA OR STEAM ROOM. GREATER THAN 61/4 INCHES (160 MM) WITH A CROSS SECTION OF DIMENSION OF NOT MORE THAN 21/4 COVERINGS TABLE R302.6 DWELLING -GARAGE SEPARATION INCHES (57 MM). EDGES SHALL HAVE A RADIUS OF NOT LESS THAN 0.01 INCH (0.25 MM). UNDERLAYMENT FOR ASPHALT SHINGLES, METAL ROOF SHINGLES, MINERAL SURFACED ROLL ROOFING, FROM THE RESIDENCE AND ATTICS R308.4.6 GLAZING ADJACENT TO STAIRS AND RAMPS SLATE AND SLATE -TYPE SHINGLES, AND METAL ROOF PANELS SHALL COMPLY WITH ONE OF THE FOLLOWING NOT LESS THAN 1/2-INCH GYPSUM BOARD OR EQUIVALENT APPLIED TO THE GARAGE SIDE GLAZING WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 36 INCHES ABOVE THE 2. TYPE II. HANDRAILS WITH A PERIMETER GREATER THAN 61/4 INCHES (160 MM) SHALL HAVE A METHODS: FROM HABITABLE ROOMS ABOVE THE GARAGE PLANE OF THE ADJACENT WALKING SURFACE OF STAIRWAYS LANDINGS BETWEEN FLIGHTS OF STAIRS GRASPABLE FINGER RECESS AREA ON BOTH SIDES OF THE PROFILE. THE FINGER RECESS SHALL BEGIN 4. TWO LAYERS OF D226 TYPE ASTM D4869 TYPE III OR TYPE IV UNDERLAYMENT SHALL BE NOT LESS THAN 5/8-INCH TYPE X GYPSUM BOARD OR EQUIVALENT AND RAMPS SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION. WITHIN A DISTANCE OF 3/4 INCH (19 MM) MEASURED VERTICALLY FROM THE TALLEST PORTION OF THE I INSTALLED LOWS:ASTM FOLLOWS: APPLY A 19-INCH (483 MM) STRIP OF UNDERLAYMENT FELT PARALLEL TO AND C STRUCTURE(S) SUPPORTING FLOOR/CEILING ASSEMBLIES USED FOR SEPARATION REQUIRED BY THIS PROFILE AND ACHIEVE A DEPTH OF NOT LESS THAN 5/16 INCH (8 MM) WITHIN 7/8 INCH (22 MM) BELOW THE T STARTING AT THE EAVES, FASTENED SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE, APPLY SECTION R308.4.7 GLAZING ADJACENT TO THE BOTTOM STAIR LANDING WIDEST PORTION OF THE PROFILE. THIS REQUIRED DEPTH SHALL CONTINUE FOR NOT LESS THAN 3/8 36-INCH-WIDE (914 MM) SHEETS OF UNDERLAYMENT, OVERLAPPING SUCCESSIVE SHEETS 19 INCHES (483 MM); NOT LESS THAN 1/2-INCH GYPSUM BOARD OR EQUIVALENT GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A STAIRWAY WHERE THE GLAZING IS LESS INCH (10 MM) TO A LEVEL THAT IS NOT LESS THAN 13/4 INCHES (45 MM) BELOW THE TALLEST PORTION OF END LAPS SHALL BE 6 INCHES AND SHALL BE OFFSET BY 6 FEET. THE UNDERLAYMENT SHALL BE ATTACHED THAN 36 INCHES ABOVE THE LANDING AND WITHIN A 60-INCH HORIZONTAL ARC LESS THAN 180 DEGREES THE PROFILE. THE WIDTH OF THE HANDRAIL ABOVE THE RECESS SHALL BE NOT LESS THAN 11/4 INCHES TO A NAILABLE DECK WITH CORROSION -RESISTANT FASTENERS WITH ONE ROW CENTERED IN THE FIELD OF R302.7 UNDER -STAIR PROTECTION FROM THE BOTTOM TREAD NOSING SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION. (32 MM) AND NOT MORE THAN 23/4 INCHES (70 MM). EDGES SHALL HAVE A RADIUS OF NOT LESS THAN 0.01 THE SHEET WITH A MAXIMUM FASTENER SPACING OF 12 INCHES (305 MM) O.C., AND ONE ROW AT THE END ENCLOSED SPACE UNDER STAIRS THAT IS ACCESSED BY A DOOR OR ACCESS PANEL SHALL HAVE WALLS, INCH (0.25 MM). AND SIDE LAPS FASTENED 6 INCHES (152 MM) O.C. UNDER -STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2-INCH (12.7 MM) GARAGES: GYPSUM BOARD. GUARDS 5. TWO LAYERS OF A REINFORCED SYNTHETIC UNDERLAYMENT THAT HAS A PRODUCT APPROVAL AS AN ALTERNATIVE TO UNDERLAYMENT COMPLYING WITH ASTM D226 TYPE II SHALL BE PERMITTED TO BE USED. R309.1 FLOOR SURFACE SYNTHETIC UNDERLAYMENT SHALL HAVE A MINIMUM TEAR STRENGTH OF 15 LBF IN ACCORDANCE WITH ASTM FLAME SPREAD INDEX AND SMOKE -DEVELOPED INDEX: GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL. R312.1.1 WHERE REQUIRED D4533 AND A MINIMUM TENSILE STRENGTH OF 20 LBF/INCH IN ACCORDANCE WITH ASTM D5035, AND SHALL GUARDS SHALL BE PROVIDED FOR THOSE PORTIONS OF OPEN -SIDED WALKING SURFACES, INCLUDING MEET THE LIQUID WATER TRANSMISSION TEST OF SECTION 8.6 OF ASTM D4869. SYNTHETIC UNDERLAYMENT R302.9 FLAME SPREAD INDEX AND SMOKE -DEVELOPED INDEX FOR WALL AND CEILING FINISHES THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO STAIRS, RAMPS AND LANDINGS, THAT ARE LOCATED MORE THAN 30 INCHES (762 MM) MEASURED SHALL BE INSTALLED AS FOLLOWS: APPLY A STRIP OF SYNTHETIC UNDERLAYMENT THAT IS HALF THE WIDTH FLAME SPREAD AND SMOKE -DEVELOPED INDEXES FOR WALL AND CEILING FINISHES SHALL BE IN FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY. VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT WITHIN 24 INCHES (610 MM) HORIZONTALLY OF A FULL SHEET PARALLEL TO AND STARTING AT THE EAVES, FASTENED SUFFICIENTLY TO HOLD IN PLACE. TO THE EDGE OF THE OPEN SIDE. INSECT SCREENING SHALL NOT BE CONSIDERED AS A GUARD. STARTING AT THE EAVE, APPLY FULL SHEETS OF REINFORCED SYNTHETIC UNDERLAYMENT, OVERLAPPING ACCORDANCE WITH SECTIONS R302.9.1 THROUGH R302.9.4. SUCCESSIVE SHEETS HALF THE WIDTH OF A FULL SHEET PLUS THE WIDTH OF THE MANUFACTURER'S EGRESS: R312.1.2 HEIGHT SINGLE -PLY OVERLAP. END LAPS SHALL BE 6 INCHES AND SHALL BE OFFSET BY 6 FEET. SYNTHETIC R302.10 FLAME SPREAD INDEX AND SMOKE -DEVELOPED INDEX FOR INSULATION REQUIRED GUARDS AT OPEN -SIDED WALKING SURFACES, INCLUDING STAIRS, PORCHES, BALCONIES OR UNDERLAYMENT SHALL BE ATTACHED TO A NAILABLE DECK WITH CORROSION -RESISTANT FASTENERS WITH A FLAME SPREAD AND SMOKE -DEVELOPED INDEX FOR INSULATION SHALL BE IN ACCORDANCE WITH R310.2.1 MINIMUM OPENING AREA LANDINGS, SHALL BE NOT LESS THAN 36 INCHES (914 MM) IN HEIGHT AS MEASURED VERTICALLY ABOVE MAXIMUM FASTENER SPACING, MEASURED HORIZONTALLY AND VERTICALLY, OF 12 INCHES (305 MM) O.C. SECTIONS R302.10.1 THROUGH R302.10.5. EMERGENCY AND ESCAPE RESCUE OPENINGS SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5.7 THE ADJACENT WALKING SURFACE OR THE LINE CONNECTING THE LEADING EDGES OF THE TREADS. BETWEEN SIDE LAPS, AND ONE ROW AT THE END AND SIDE LAPS FASTENED 6 INCHES (152 MM) O.C. FIREBLOCKING: SQUARE FEET. THE NET CLEAR HEIGHT OPENING SHALL BE NOT LESS THAN 24 INCHES AND THE NET UNDERLAYMENT SHALL BE ATTACHED USING ANNULAR RING OR DEFORMED SHANK NAILS WITH METAL OR CLEAR WIDTH SHALL BE NOT LESS THAN 20 INCHES. EXCEPTIONS: PLASTIC CAPS WITH A NOMINAL CAP DIAMETER OF NOT LESS THAN 1 INCH. METAL CAPS ARE REQUIRED 1. GUARDS ON THE OPEN SIDES OF STAIRS SHALL HAVE A HEIGHT NOT LESS THAN 34 INCHES (864 MM) WHERE THE ULTIMATE DESIGN WIND SPEED, VULT, EQUALS OR EXCEEDS 170 MPH. METAL CAPS SHALL HAVE R302.11 FIREBLOCKING EXCEPTION: GRADE FLOOR OR BELOW GRADE OPENINGS SHALL HAVE A NET CLEAR OPENING OF NOT MEASURED VERTICALLY FROM A LINE CONNECTING THE LEADING EDGES OF THE TREADS. A THICKNESS OF NOT LESS THAN 32-GAGE SHEET METAL. POWER -DRIVEN METAL CAPS SHALL HAVE A IN COMBUSTIBLE CONSTRUCTION, FIREBLOCKING SHALL BE PROVIDED TO CUT OFF BOTH VERTICAL AND LESS THAN 5 SQUARE FEET. 2. WHERE THE TOP OF THE GUARD SERVES AS A HANDRAIL ON THE OPEN SIDES OF STAIRS, THE TOP MINIMUM THICKNESS OF 0.010 INCH. MINIMUM THICKNESS OF THE OUTSIDE EDGE OF PLASTIC CAPS SHALL BE HORIZONTAL CONCEALED DRAFT OPENINGS AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN OF THE GUARD SHALL BE NOT LESS THAN 34 INCHES (864 MM) AND NOT MORE THAN 38 INCHES (965 MM) 0.035 INCH. THE CAP NAIL SHANK SHALL BE NOT LESS THAN 0.083 INCH FOR RING SHANK CAP NAILS. CAP NAIL STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. R310.2.2 WINDOW SILL HEIGHT AS MEASURED VERTICALLY FROM A LINE CONNECTING THE LEADING EDGES OF THE TREADS. SHANK SHALL HAVE A LENGTH SUFFICIENT TO PENETRATE THROUGH THE ROOF SHEATHING OR NOT LESS WHERE A WINDOW IS PROVIDED AS THE EMERGENCY ESCAPE AND RESCUE OPENING, IT SHALL HAVE A THAN 3/4 INCH INTO THE ROOF SHEATHING. FIREBLOCKING SHALL BE PROVIDED IN WOOD -FRAMED CONSTRUCTION IN THE FOLLOWING LOCATIONS: SILL HEIGHT OF NOT MORE THAN 44 INCHES ABOVE THE FLOOR. R312.1.3 OPENING LIMITATIONS REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED R905.2.4.1 WIND RESISTANCE OF ASPHALT SHINGLES (IF APPLICABLE) 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND R310.1.1 OPERATIONAL CONSTRAINTS AND OPENING CONTROL DEVICES GUARD HEIGHT THAT ALLOW PASSAGE OF A SPHERE 4 INCHES (102 MM) IN DIAMETER. ASPHALT SHINGLES SHALL BE INSTALLED IN ACCORDANCE WITH SECTIONS R905.2.6 AND R905.2.6.1. PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS: EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM R905.3 CLAY AND CONCRETE TILE 1.1.VERTICALLY AT THE CEILING AND FLOOR LEVELS. WITHOUT THE USE OF KEYS, TOOLS OR SPECIAL KNOWLEDGE. WINDOW OPENING CONTROL DEVICES EXCEPTIONS: THE INSTALLATION OF CLAY AND CONCRETE TILE SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S 1.2.HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET (3048 MM). COMPLYING WITH ASTM F2090 SHALL BE PERMITTED FOR USE ON WINDOWS SERVING AS A REQUIRED 1. THE TRIANGULAR OPENINGS AT THE OPEN SIDE OF STAIR FORMED BY THE RISER TREAD AND INSTALLATION INSTRUCTIONS, OR RECOMMENDATIONS OF FRSA/TRI FLORIDA HIGH WIND CONCRETE AND 2. AT INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS EMERGENCY ESCAPE AND RESCUE OPENING. BOTTOM RAIL OF A GUARD, SHALL NOT ALLOW PASSAGE OF A SPHERE 6 INCHES (153 MM) IN DIAMETER. CLAY ROOF TILE INSTALLATION MANUAL, SIXTH EDITION WHERE THE VASD IS DETERMINED IN ACCORDANCE OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS. 2. GUARDS ON THE OPEN SIDE OF STAIRS SHALL NOT HAVE OPENINGS THAT ALLOW PASSAGE OF A WITH SECTION R301.2.1.3 OR THE RECOMMENDATIONS OF RAS 118,119 OR 120. 3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. R312.2.1 WINDOW SILLS SPHERE 43/8 INCHES (111 MM) IN DIAMETER. ENCLOSED SPACES UNDER STAIRS SHALL COMPLY WITH SECTION R302.7. IN DWELLING UNITS, WHERE THE TOP OF THE SILL OF AN OPERABLE WINDOW OPENING IS LOCATED LESS EXHAUST SYSTEMS: 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES AT CEILING AND FLOOR LEVEL, THAN 24 INCHES (610 MM) ABOVE THE FINISHED FLOOR AND GREATER THAN 72 INCHES (1829 MM) ABOVE CONCRETE FLOORS: WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF THE FINISHED GRADE OR OTHER SURFACE BELOW ON THE EXTERIOR OF THE BUILDING, THE OPERABLE M1501.1 OUTDOOR DISCHARGE COMBUSTION. THE MATERIAL FILLING THIS ANNULAR SPACE SHALL NOT BE REQUIRED TO MEET THE ASTM WINDOW SHALL COMPLY WITH ONE OF THE FOLLOWING: R506.2.3 VAPOR RETARDER THE AIR REMOVED BY EVERY MECHANICAL EXHAUST SYSTEM SHALL BE DISCHARGED TO THE OUTDOORS IN E136 REQUIREMENTS. A 6-MIL (0.006 INCH; 152 MM) POLYETHYLENE OR APPROVED VAPOR RETARDER WITH JOINTS LAPPED NOT ACCORDANCE WITH SECTION M1506.3. AIR SHALL NOT BE EXHAUSTED INTO AN ATTIC SOFFIT, RIDGE VENT OR 5. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES, SEE SECTION R1003.19. 1. OPERABLE WINDOWS WITH OPENINGS THAT WILL NOT ALLOW A 4-INCH-DIAMETER (102 MM) SPHERE LESS THAN 6 INCHES (152 MM) SHALL BE PLACED BETWEEN THE CONCRETE FLOOR SLAB AND THE BASE CRAWL SPACE. 6. FIREBLOCKING OF CORNICES OF A TWO-FAMILY DWELLING IS REQUIRED AT THE LINE OF DWELLING TO PASS THROUGH THE OPENING WHERE THE OPENING IS IN ITS LARGEST OPENED POSITION. COURSE OR THE PREPARED SUBGRADE WHERE NO BASE COURSE EXISTS. UNIT SEPARATION. 2. OPERABLE WINDOWS THAT ARE PROVIDED WITH WINDOW FALL PREVENTION DEVICES THAT M1502.4.5 DRYER DUCT LENGTH COMPLY WITH ASTM F2090. EXCEPTION: THE VAPOR RETARDER IS NOT REQUIRED FOR THE FOLLOWING: THE MAXIMUM ALLOWABLE EXHAUST DUCT LENGTH SHALL BE DETERMINED BY ONE OF THE METHODS R302.11.1 FIREBLOCKING MATERIALS 3. OPERABLE WINDOWS THAT ARE PROVIDED WITH WINDOW OPENING CONTROL DEVICES THAT 1. GARAGES, UTILITY BUILDINGS AND OTHER UNHEATED ACCESSORY STRUCTURES. SPECIFIED IN SECTIONS M1502.4.5.1 THROUGH M1502.4.5.3. EXCEPT AS PROVIDED IN SECTION R302.11, ITEM 4, FIREBLOCKING SHALL CONSIST OF THE FOLLOWING COMPLY WITH SECTION R312.2.2. 2. FOR UNHEATED STORAGE ROOMS HAVING AN AREA OF LESS THAN 70 SQUARE FEET (6.5 M2) AND M1502.4.5.1 SPECIFIED LENGTH MATERIALS. CARPORTS. THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE 35 FEET (10 668 MM) FROM THE CONNECTION TO THE STAIRWAYS: 3. DRIVEWAYS, WALKS, PATIOS AND OTHER FLATWORK NOT LIKELY TO BE ENCLOSED AND HEATED AT TRANSITION DUCT FROM THE DRYER TO THE OUTLET TERMINAL. WHERE FITTINGS ARE USED, THE MAXIMUM 1. TWO-INCH (51 MM) NOMINAL LUMBER. A LATER DATE. LENGTH OF THE EXHAUST DUCT SHALL BE REDUCED IN ACCORDANCE WITH TABLE M1502.4.5.1. THE MAXIMUM 2. TWO THICKNESSES OF 1-INCH (25.4 MM) NOMINAL LUMBER WITH BROKEN LAP JOINTS. R311.7.1 WIDTH 4. WHERE APPROVED BY THE BUILDING OFFICIAL, BASED ON LOCAL SITE CONDITIONS. LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT. 3. ONE THICKNESS OF 23/32-INCH (18.3 MM) WOOD STRUCTURAL PANELS WITH JOINTS BACKED BY STAIRWAYS SHALL BE NOT LESS THAN 36 INCHES (914 MM) IN CLEAR WIDTH AT ALL POINTS ABOVE THE 23/32-INCH (18.3 MM) WOOD STRUCTURAL PANELS. PERMITTED HANDRAIL HEIGHT AND BELOW THE REQUIRED HEADROOM HEIGHT. THE CLEAR WIDTH OF WALL COVERING: MANUFACTURER'S INSTRUCTIONS 4. ONE THICKNESS OF 3/4-INCH (19.1 MM) PARTICLEBOARD WITH JOINTS BACKED BY 3/4-INCH (19.1 MM) THE STAIRWAY AT AND BELOW THE HANDRAIL HEIGHT, INCLUDING TREADS AND LANDINGS, SHALL BE NOT A THE SAND MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE DETERMINED BY THE DRYER THE S PARTICLEBOARD. LESS THAN 311/2 INCHES (787 MM) WHERE A HANDRAIL IS INSTALLED ON ONE SIDE AND 27 INCHES (698 R702.4.2 BACKER BOARDS MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE CODE OFFICIAL SHALL BE PROVIDED WITH A COPY OF 5. ONE -HALF -INCH (12.7 MM) GYPSUM BOARD. MM) WHERE HANDRAILS ARE PROVIDED ON BOTH SIDES. MATERIALS USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN THE INSTALLATION INSTRUCTIONS FOR THE MAKE AND MODEL THE DRYER AT THE CONCEALMENT CALCULATIONS FROM THE CLOTHES DRYER INSPECTION. IN THE ABSENCE OF FITTING EQUIVALENT LENGTH C 6. ONE -QUARTER -INCH (6.4 MM) CEMENT -BASED MILLBOARD. SHOWER AREAS SHALL BE OF MATERIALS LISTED IN TABLE R702.4.2, AND INSTALLED IN ACCORDANCE TABLE M1502.4.5.1 SHALL BE USED. 7. BATTS OR BLANKETS OF MINERAL WOOL OR GLASS FIBER OR OTHER APPROVED MATERIALS R311.7.2 HEADROOM WITH THE MANUFACTUREROS RECOMMENDATIONS.MANUFACTURER, INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE. THE HEADROOM IN STAIRWAYS SHALL BE NOT LESS THAN 6 FEET 8 INCHES (2032 MM) MEASURED M1502.4.5.3 DRYER EXHAUST DUCT POWER VENTILATOR 8. CELLULOSE INSULATION INSTALLED AS TESTED IN ACCORDANCE WITH ASTM El 19 OR UL 263, FOR VERTICALLY FROM THE SLOPED LINE ADJOINING THE TREAD NOSING OR FROM THE FLOOR SURFACE OF TABLE R702.4.2BACKER BOARD MATERIALS THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE DETERMINED IN ACCORDANCE WITH THE THE SPECIFIC APPLICATION. THE LANDING OR PLATFORM ON THAT PORTION OF THE STAIRWAY. GLASS MAT GYPSUM BACKING PANEL (ASTM C1178) MANUFACTURER'S INSTRUCTIONS FOR THE DRYER EXHAUST DUCT POWER VENTILATOR. GYPSUM PANELS (ASTM C1278) R302.12 DRAFTSTOPPING R311.FIBER-REINFORCED STAIR TREADS AND RISERS NONASBESTOS FIBER -CEMENT BACKER BOARD (ASTM C1288 OR ISO 8336, CATEGORY C) GENERAL NOTES: IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE STAIR T STAIR TREADS AND RISERS SHALL MEET THE REQUIREMENTS OF THIS SECTION. FOR THE PURPOSES OF S NONASBESTOS FIBER MAT REINFORCED CEMENTITIOUS BACKER UNITS (ASTM C1325) EA LED CONCEALED SPACE OF AFLOOR-CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE THIS SECTION, DIMENSIONS AND DIMENSIONED SURFACES SHALL BE EXCLUSIVE OF CARPETS, RUGS OR ATTENTION GENERAL CONTRACTOR /BUILDER: AREA THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET (92.9 MT). TOPPING RUNNERS. WINDOW INSTALLATION ISSUANCE OF PLANS FROM THE ARCHITECT SHALL NOT RELIEVE THE BUILDER OF RESPONSIBILITY TO REVIEW SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. WHERE THE ASSEMBLY IS WINDOWS SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN AND VERIFY ALL NOTES, DIMENSIONS, AND ADHERENCE APPLICABLE BUILDING CODES PRIOR ENCLOSED BY A FLOOR MEMBRANE ABOVE AND A CEILING MEMBRANE BELOW, DRAFTSTOPPING SHALL R311.7.5.1 RISERS INSTALLATION INSTRUCTIONS. WRITTEN INSTALLATION INSTRUCTIONS SHALL BE PROVIDED BY THE ,TO COMMENCEMENT OF ANY CONSTRUCTION. ANY DISCREPANCY OF ERROR IN NOTES, DIMENSIONS, OR BE PROVIDED IN FLOOR -CEILING ASSEMBLIES UNDER THE FOLLOWING CIRCUMSTANCES: THE RISER HEIGHT SHALL BE NOT MORE THAN 73/4 INCHES (196 MM). THE RISER SHALL BE MEASURED MANUFACTURER FOR EACH WINDOW. ADHERENCE TO APPLICABLE BUILDING CODES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. THE GREATEST RISER HEIGHT FOR CORRECTION BEFORE COMMENCEMENT OF ANY CONSTRUCTION CORRECTION / REVISIONS. ANY 1.CEILING IS SUSPENDED UNDER THE FLOOR FRAMING. WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH (9.5 MM). R703.4 FLASHING REVISIONS OR CHANGES, NOT RELATED TO THE CORRECTION OF ERRORS THAT ARE MADE AFTER THE FINAL RISERS SHALL BE VERTICAL OR SLOPED FROM THE UNDERSIDE OF THE NOSING OF THE TREAD ABOVE AT APPROVED METAL FLASHING, VINYL FLASHING, SELF -ADHERED MEMBRANES AND MECHANICALLY PLANS HAVE BEEN COMPLETED SHALL BE SUBJECT TO ADDITIONAL FEES. IF ANY MODIFICATIONS ARE MADE TO THESE PLANS BY ANY OTHER PARTY OTHER THAN THE ARCHITECT, THE ARCHITECT SHALL NOT BE HELD 2.FLOOR FRAMING IS CONSTRUCTED OF TRUSS -TYPE OPEN -WEB OR PERFORATED MEMBERS. AN ANGLE NOT MORE THAN 30 DEGREES (0.51 RAID) FROM THE VERTICAL. OPEN RISERS ARE PERMITTED ATTACHED FLEXIBLE FLASHING SHALL BE APPLIED SHINGLE -FASHION OR IN ACCORDANCE WITH THE RESPONSIBLE. PROVIDED THAT THE OPENINGS LOCATED MORE THAN 30 INCHES (762 MM), AS MEASURED VERTICALLY, MANUFACTURER'S INSTRUCTIONS. METAL FLASHING SHALL BE CORROSION RESISTANT. FLUID -APPLIED R302.12.1 MATERIALS TO THE FLOOR OR GRADE BELOW DO NOT PERMIT THE PASSAGE OF A 4-INCH-DIAMETER (102 MM) MEMBRANES USED AS FLASHING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S INSPECTION NOTES: DRAFTSTOPPING MATERIALS SHALL BE NOT LESS THAN 1/2-INCH (12.7 MM) GYPSUM BOARD, 3/8-INCH (9.5 SPHERE. INSTRUCTIONS. ALL FLASHING SHALL BE APPLIED IN A MANNER TO PREVENT THE ENTRY OF WATER INTO WORK SHALL NOT BE DONE BEYOND THE POINT INDICATED IN EACH SUCCESSIVE INSPECTION WITHOUT FIRST MM) WOOD STRUCTURAL PANELS OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED. THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. OBTAINING THE APPROVAL OF THE BUILDING OFFICIAL. THE BUILDING OFFICIAL, UPON NOTIFICATION, SHALL DRAFTSTOPPING SHALL BE INSTALLED PARALLEL TO THE FLOOR FRAMING MEMBERS UNLESS R311.7.5.2 TREADS SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. ALL EXTERIOR MAKE THE REQUESTED INSPECTIONS AND SHALL EITHER INDICATE THE PORTION OF THE CONSTRUCTION OTHERWISE APPROVED BY THE BUILDING OFFICIAL. THE INTEGRITY OF THE DRAFTSTOPS SHALL BE THE TREAD DEPTH SHALL BE NOT LESS THAN 10 INCHES (254 MM). THE TREAD DEPTH SHALL BE FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE BUILDING WALL WITH A THAT IS SATISFACTORY AS COMPLETED, OR NOTIFY THE PERMIT HOLDER OR HIS OR HER AGENT WHEREIN MAINTAINED. MEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF SEALANT COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 GRADE NS OR GREATER FOR PROPER THE SAME FAILS TO COMPLY WITH THIS CODE. ANY PORTIONS THAT DO NOT COMPLY SHALL BE CORRECTED ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREAD'S LEADING EDGE. THE GREATEST TREAD JOINT EXPANSION AND CONTRACTION, ASTM C1281, AAMA 812, OR OTHER APPROVED STANDARD AS AND SUCH PORTION SHALL NOT BE COVERED OR CONCEALED UNTIL AUTHORIZED BY THE BUILDING OFFICIAL. HAZARDOUS LOCATIONS: DEPTH WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH (9.5 APPROPRIATE FOR THE TYPE OF SEALANT. FLUID -APPLIED MEMBRANES USED AS FLASHING IN EXTERIOR FOUNDATION INSPECTION NOTES: MM). WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON SITE FOR THE R308.4.1 GLAZING IN DOORS R311.7.5.3 NOSINGS EXTERIOR WALL FINISH. APPROVED FLASHINGS SHALL BE INSTALLED AT THE FOLLOWING LOCATIONS: BUILDING INSPECTOR'S USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND A STRING STRETCHED GLAZING IN FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BIFOLD DOORS SHALL BE NOSINGS AT TREADS, LANDINGS AND FLOORS OF STAIRWAYS SHALL HAVE A RADIUS OF CURVATURE AT 1.EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS FROM MARKER TO MARKER TO VERIFY REQUIRED SETBACKS. CONSIDERED TO BE A HAZARDOUS LOCATION. THE NOSING NOT GREATER THAN 9/16 INCH 14 MM OR A BEVEL NOT EXCEEDING 1/2 INCH 12.7 MM . A ( ) ( ) SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE BARRIER EXTERIOR FINISHES: NOSING PROJECTION NOT LESS THAN 3/4 INCH (19 MM) AND NOT MORE THAN 11/4 INCHES (32 MM) SHALL COMPLYING WITH SECTION 703.2 FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE 1. CEMENT PLASTER FINISH OVER MASONRY SHALL BE 5/8" THICK TEXTURED PER COMMUNITY EXCEPTIONS: BE PROVIDED ON STAIRWAYS. THE GREATEST NOSING PROJECTION SHALL NOT EXCEED THE SMALLEST FLASHINGS SHALL COMPLY WITH AAMA 712. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS STANDARDS. 1. GLAZED OPENINGS OF A SIZE THROUGH WHICH A 3-INCH-DIAMETER SPHERE IS UNABLE TO PASS. NOSING PROJECTION BY MORE THAN 3/8 INCH (9.5 MM) WITHIN A STAIRWAY. SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE FOLLOWING: 2. CEMENT PLASTER FINISH OVER WOOD SUBSTRATE SHALL BE 7/8" THICK (3) COAT STUCCO OVER (2) 2. DECORATIVE GLAZING LAYERS OF WATER RESISTANT BARRIERS IN ACCORDANCE WITH FLORIDA BUILDING CODE 7TH EDITION (2020) EXCEPTION: A NOSING PROJECTION IS NOT REQUIRED WHERE THE TREAD DEPTH IS NOT LESS THAN 11 1.1. THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING INSTRUCTIONS, OR FOR RESIDENTIAL, R703 AND ASTM C926. TEXTURE PER COMMUNITY R308.4.2 GLAZING ADJACENT TO DOORS. INCHES (279 MM). APPLICATIONS NOT ADDRESSED IN THE FENESTRATION MANUFACTURER'S INSTRUCTIONS, IN GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR SHALL BE CONSIDERED TO ACCORDANCE WITH THE FLASHING MANUFACTURER'S INSTRUCTIONS. WHERE FLASHING INSTRUCTIONS FLOOD ZONE REQUIREMENTS: rj BE A HAZARDOUS LOCATION WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 R311.7.8 HANDRAILS OR DETAILS ARE NOT PROVIDED, PAN FLASHING SHALL BE INSTALLED AT THE SILL OF EXTERIOR WINDOW PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGE FLOOR ELEVATION. c� INCHES ABOVE THE FLOOR OR WALKING SURFACE AND IT MEETS EITHER OF THE FOLLOWING HANDRAILS SHALL BE PROVIDED ON NOT LESS THAN ONE SIDE OF EACH FLIGHT WITH FOUR OR MORE AND DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT MECHANICAL AND HVAC: CONDITIONS: RISERS. WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE BARRIER FOR 1. ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES SHALL BE FURNISHED BY THE 1. WHERE THE GLAZING IS WITHIN 24 INCHES OF EITHER SIDE OF THE DOOR IN THE PLANE OF THE R311.7.8.1 HEIGHT SUBSEQUENT DRAINAGE. OPENINGS USING PAN FLASHING SHALL INCORPORATE FLASHING OR GENERAL CONTRACTOR AS AN ATTACHMENT TO THIS PLAN SET AT THE TIME OF APPLICATION FOR PERMIT. DOOR IN A CLOSED POSITION. HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED PLANE ADJOINING THE TREAD NOSING, PROTECTION AT THE HEAD AND SIDES. 1.2. IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN 2. MECHANICAL APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION, OTHER APPLIANCES, OR ANY OTHER 2. WHERE THE GLAZING IS ON A WALL LESS THAN 180 DEGREES FROM THE PLANE OF THE DOOR IN A OR FINISH SURFACE OF RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES (864 MM) AND NOT MORE PROFESSIONAL. PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE BEING INSPECTED, SERVICED, REPAIRED, OR CLOSED POSITION AND WITHIN 24 INCHES OF THE HINGE SIDE OF AN IN -SWINGING DOOR. THAN 38 INCHES (965 MM). 1.3. IN ACCORDANCE WITH OTHER APPROVED METHODS. REPLACED. A LEVEL WORKING SPACE AT LEAST 30 INCHES (762 mm) DEEP AND 30 INCHES (762 mm) WIDE 1.4. IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA 250, FMA/AAMA/WDMA 300 OR SHALL BE PROVIDED IN FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE. EXCEPTIONS: EXCEPTIONS: FMA/AAMA/WDMA 400. 3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING 1. DECORATIVE GLAZING. 1. THE USE OF A VOLUTE, TURNOUT OR STARTING EASING SHALL BE ALLOWED OVER THE LOWEST 2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR FROM THE GARAGE SHALL BE CONSTRUCTED OF A MIN. #26 GAUGE (0.48 mm) SHEET STEEL OR OTHER 2. WHERE THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE DOOR TREAD. STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. AND THE GLAZING. 2. WHERE HANDRAIL FITTINGS OR BENDINGS ARE USED TO PROVIDE CONTINUOUS TRANSITION 3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 4. FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE RAISED AT LEAST 3 3. WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET OR LESS IN BETWEEN FLIGHTS, TRANSITIONS AT WINDER TREADS, THE TRANSITION FROM HANDRAIL TO GUARD, OR 4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. INCHES (76 mm) ABOVE THE FINISHED GRADE AND SHALL ALSO CONFORM TO THE MANUFACTURER'S DEPTH. GLAZING IN THIS APPLICATION SHALL COMPLY WITH SECTION R308.4.3. USED AT THE START OF A FLIGHT, THE HANDRAIL HEIGHT AT THE FITTINGS OR BENDINGS SHALL BE 5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF INSTALLATION INSTRUCTIONS. 5. AUXILIARY DRAIN PAN. CATEGORY IV CONDENSING APPLIANCES SHALL BE PROVIDED WITH AN 4. GLAZING THAT IS ADJACENT TO THE FIXED PANEL OF PATIO DOORS. PERMITTED TO EXCEED 38 INCHES (956 MM). WOOD -FRAME CONSTRUCTION. AUXILIARY DRAIN PAN WHERE DAMAGE TO ANY BUILDING COMPONENT WILL OCCUR AS A RESULT OF 6. AT WALL AND ROOF INTERSECTIONS. STOPPAGE IN THE CONDENSATE DRAIN PIPING SYSTEM. THESE PANS SHALL BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF SECTIONS M1411.3. 0 � w z cl Y Q Q � W a m cr LL O C)H co 00 p Urn UCDaz a w co =zuWia Ff za a Ir Q U C) 0 Q LJ _j rn c/) �! o 1 0 cz,Pool °r_ c zr- Z z w O �� 0 z O U Q w O w z z a 2 Ir O 2 Ir O t� � VJ z z a w z 0 M � w 1_l C) O O 0 Z CE w CE m V O 0 O z z w m a w < O z z a 0 IrW 0 06 Lo C z a J O w Lu w 0 0 z i *�i1 a W 0 06 a J w W w Z O z a u 0 U W > 0 w a_ O Ir a- CE w Z O O 4 0 ( c Q y aQ� Z �P.•oGGio ko �• AR94880 Comm : WATERSTONE PLAN # 6076 RELEASED: 7/30/21 SHEET CS2 J cn cn w Ir a- X w cn w 2 O z a z a z O .. F O N d' 00 L0 T 1 _ A5.1 I I REFRIGERANT LINE — THROUGH ATTIC METAL THRESHOLD WEATHER STRIPPING 3068 SOLID PANEL DOOR EGRESS MOISTURE RESISTANT DRYWALL CLG. METAL THRESHOLD WEATHER STRIPPING Q N T 0 N Lo CM v7 Lo N Lo c0 511 CONC. STOOP 35'-011 6'-611 6'-8"x3'-0" 1 7'-211 35 SH 6068 SrI TEMP I I I � I � I I 15'-11" 5'-41 I I rco I O 1 1 GREAT = ; OS ROOM U ; WIC 8'-8" CLG. °C i 8'-8" CLG. I I R&S DINING AREA 8'-8" CLG. 6-31" 2 EX STE PLUS N BATH r 8'-8" CLG. FOYER 8'-8" CLG. XFER GRILL co 1-0 rl I(V rT 1 1� _I co T BRK 81_O11 I I� I of \ \ IJ <_ �I _'^^ I [0]'�/ T >! o Oo 1 T 5111 x 22 INI ` 81_211 L LI Y Im 3-7211 41_211 KITCHEN 8'-8" CLG. LO I I 1 V-8211 ------------; 3'-811 34"x60" TUB P �IN N LIC COMM. - In w Lo SHWR SPEC 51_ " 51.3211 HALL 2 B "CLG J J �6G 2X6 J AHU ON WALL STAND EX STE PLUS BEDROOM = 8'-8" CLG. rlc\j 1 h1 711 K 21-111 -7211 1 p'_0111 r c'? DR2YER VENT T ao WASHER BOX cn w EX STE 2X6 N PLUS WIC WALL w 8'-8" CLG. co 3'-10211 31_52111 41-411 x M DRYER RK VENT ENTRY W/D SPACE 'IN 8'-8° CLG. \Q o� 6�; ��?Cb r---- LNDY O XFER i CL i cxu I i 06 g� GRILL I I I QL177 _____J -- I R&S I BRK FLAT SOFFIT WASHER ---- _-� AT 7-4" BOX L rtUIC 24 RE L------------ WET BAR 3'-7" 7'-1111 a, 11'-611 in T N co r\/ ATr 1"�1 1 IA T LIVING ROOM 8'-8" CLG. 35 5-1111 5'-9" 11'-811 FIRST FLOOR PLAN 7'-711 35 SH i 54"X63" EGRESS 13'-2" OWNER'S N SUITE 8'-8" CLG. T REF. 5-1311 �F WATER LINE RK (�uJ w ---- TCO IN _X Q ---- I ° 0 Ln > C7 Ln M co I I Q 41_911 31_ 11 I I - J I 1 = (� L � r� - BOATH - -- \01 N co`b 8 '-8" C� V �O 2'-2" 8'-p11 BEDROOM 2 8'-8" CLG -IN 0 T_ BRK^ I 1 1 RK 66\� r0') 3'-2" Y HALL Fc\I 8'-8" CLG. _____—c� CL R&S MET L RAG XFER LOCATION GRILL --R&S CL --- --- RK RK I N H � 1 — _— _ ADD 16" OSB *11 —IN I_ TO MECH. C . co CEILING FO 111 -22 ,- 111 3 112 FIRE DRAFT �- 1�� 6 62 11 STOP D LAUNDRY 3,_7211 w J 8'-8" CLG. C/) Tr_� c -� BEDROOM 3 1� 1 �6� T 8'-8" CLG. 1 p'-2" 7'-211 WH L 2868 SC W/ CV SELF CLOSER AND 1/2" WALL METAL THRESHOLD 21_p11 WEATHER STRIPPING BOARD ON GARAGE SIDE PROVIDE 7 2" STEEL INSULATION 22" X 54" I I ATTIC ACCESS I BOLLARD PER AS REQ'D J COMMUNITY SPEC'S LOCATE MICRO. IN UPPER CABS. cV 1 — LINE OF 2" c:)N CONC.CURB 17'-611 Ic----------------------------------------� I \\ I 2 CAR GARAGE 8'-8" CLG. \\\\\ 16070 GARAGE DOOR i 16'-011 18'-818'-8" '-011 35 Lo c0 N w w _cr) c/)(o x Lf)r- N cy) 0) T 0 0 cn w Ir c� w = M co(D x U-)� N M co 1 N LOCATION VARIES PER MAIN WATER m SERVICE CONNECTION LEGEND SYMBOLS n BUILDING/WALL SECTION MARKER SHT OINTERIOR ELEVATION MARKER * EMERGENCY ESCAPE & RESCUE dP ELEVATION STEP BRKX FLOORING BREAK WALL TYPES 0 2x WOOD/STEEL FRAMED PARTITION © INTERIOR PARTITION w/ INSULATION CMU WALL CMU WALL w/ FURRING & INSULATION NOTE: INTERIOR WALLS ARE DRAWN TO ROUGH DIMENSIONS SECTION C TYPICAL KITCHEN ISLAND SOLID SURFACE COUNTERTOP. INSTALLER TO PROVIDE APPROPRIATE COUNTERTOP SUPPORT IF REQUIRED TOP PLATE 2X6 STUD WALL SEE PLANS FOR WALL LAYOUT 1/2" GYP. r BD. tBASE CABINET AS r PER SHOP DWG.j CV WD.BASE MOLDING FINISH FLOOR FINISH FLOOR SUBFLOOR TYPICAL DOOR PLACEMENT DIAGRAMS E.Q. E.Q. O DOORS LOCATED WITHIN A LENGTH OF WALL ARE TO BE CENTERED UNLESS DIMENSIONED OR NOTED OTHERWISE. 11 O DOORS LOCATED ADJACENT TO WALL INTERSECTIONS ARE TO BE PLACED 3" MEASURED FROM INTERSECTION TO DOOR JAMB UNLESS DIMENSIONED OR NOTED OTHERWISE. NOTE: TYP. WINDOW HEAD HGT. AT 7'-4" U.N.O. 0 z w Y a Q F_ LU m cr J O Y F_ o co Lo Oco ('3 rn ¢ C) Q w =z�¢ F_ za a IY Q o 0 _U Q C) J 0.) c/) 0 j� V 0 m 0 O 1j w 1j cn z y W omm WATERSTONE PLAN # 6076 RELEASED: 7/30/21 SHEET A I . "I J v7 U) w x w wo w 2 O z a z z O SCALE: 1 /4"=V-0" Mir CO N T N. - 12 �5 REAR ELEVATION SCALE: 1 /4"=1'-0" ROOF PEAK HEIGHT 5:12 12 5 � 5:12 0 ROOF MEAN HEIGHT — 5:12 6" ALUMINUM WRAPPED FASCIA W/ VINYL 6" WIDE VENTED SOFFIT, TYP. STUCCO BAND (+1) T.O. MASONRY T.O. WINDOW ROOF SHINGLES PER COMMUNITY SPECS. 12 5 !ul WWI ®_ FRONT ELEVATION SCALE: 1 /4"=1'-0" ROOF SHINGLES PER COMMUNITY SPECS. — 6" ALUMINUM WRAPPED FASCIA W/ VINYL VENTED SOFFIT, TYP. 1'-01, H 2 I T � U Q O U 6" WIDE STUCCO BAND (+1) PAINT AND FINISH SCHEDULE I KEY PAINT COLOR SCHEME SURFACE TEXTURE / FINISH KEY MEDIUM TEXTURE / BODY COLOR SKIP TROWEL FINISH TRIM COLOR SAND FINISH NOTE: WRAP THE SAND FINISH TRIM BAND (WHERE SHOWN AROUND WINDOWS & DOORS) INTO THE JAMB, HEAD & SILL OF THE WINDOW & DOORS. PAINT THE BAND, JAMB, HEAD & SILL THE TRIM COLOR. STUCCO INSTALLATION STUCCO AND PORTLAND CEMENT PLASTER SHALL BE INSTALLED PER THE CURRENT ASTM C926 & C1063 REQUIREMENTS & PROVISIONS OF THE FLORIDA BUILDING CODE STUCCO SHALL NOT BE LESS THAN 3 COATS WHEN APPLIED OVER METAL OR WIRE LATH AND SHALL NOT BE LESS THAN 2 COATS WHEN APPLIED OVER MASONRY CONTROL JOINTS IN 3-COAT STUCCO SHALL BE USED TO DELINEATE STUCCO AREAS NOT GREATER THAN 144 SO. FT. OR AT A MAXIMUM DISTANCE OF 18' BETWEEN JOINTS PER ASTM C1063 (CURRENT EDITION) WEEP SCREED SHALL BE INSTALLED AT ALL STUCCO TRANSITIONS BETWEEN WOOD AND MASONRY AS REQUIRED BY ASTM C1063 (CURRENT EDITION) z Q Y Q Q � W m ILL O o � co O °o 0 (D rn cr- U 00 a z uj Q =ZCQ za Ir Q U C) Q LJ -j rn 1� o cz,� ---.Icz o� °� cz z� �� Qo Q Z z w O �� 0 z O Q U Q w O _ j/) w �/z z z rr O ° Ir LIB O 1 w z Q z w U O w 0 0 0 0 Lu iii w W CE w m u o 0 O z w Q W w U) O Q 0 cb 06 0 L � 1 � z Q J 0 w Lu 0 w _ 0 0 � z Q W m 06 z Q J a_ w w Z O z a u0 U) m c w a_ O Ir a- Ir w _ Zuj O O 4 0 rn c z y iaQ� t z LL �P�•�GGlok O AR94880 Comm : WATERSTONE PLAN # 6076 RELEASED: 7/30/21 SHEET A2. 1 J cn cn w Ir a- x w cn w 2 O _ z Q z Q z 0 1'-0„ FIN. FLR 1'-0" FIN. FLR 12 5 -t rc } LEFT ELEVATION SCALE: 1 /4"=1'-0" ROOF SHINGLES PER COMMUNITY SPECS. 12 5 RIGHT ELEVATION SCALE: 1/4"=1'-0" 12 5� 35 SH 5:12 0 5:12 0 12 5 — ROOF SHINGLES PER COMMUNITY SPECS. 12 77::::�5 12 5 1'-011 u FIN. FLR. PAINT AND FINISH SCHEDULE I KEY PAINT COLOR SCHEME SURFACE TEXTURE / FINISH KEY MEDIUM TEXTURE / BODY COLOR SKIP TROWEL FINISH TRIM COLOR SAND FINISH NOTE: WRAP THE SAND FINISH TRIM BAND (WHERE SHOWN AROUND WINDOWS & DOORS) INTO THE JAMB, HEAD & SILL OF THE WINDOW & DOORS. PAINT THE BAND, JAMB, HEAD & SILL THE TRIM COLOR. STUCCO INSTALLATION STUCCO AND PORTLAND CEMENT PLASTER SHALL BE INSTALLED PER THE CURRENT ASTM C926 & C1063 REQUIREMENTS & PROVISIONS OF THE FLORIDA BUILDING CODE STUCCO SHALL NOT BE LESS THAN 3 COATS WHEN APPLIED OVER METAL OR WIRE LATH AND SHALL NOT BE LESS THAN 2 COATS WHEN APPLIED OVER MASONRY CONTROL JOINTS IN 3-COAT STUCCO SHALL BE USED TO DELINEATE STUCCO AREAS NOT GREATER THAN 144 SQ. FT. OR AT A MAXIMUM DISTANCE OF 18' BETWEEN JOINTS PER ASTM C1063 (CURRENT EDITION) WEEP SCREED SHALL BE INSTALLED AT ALL STUCCO TRANSITIONS BETWEEN WOOD AND MASONRY AS REQUIRED BY ASTM C1063 (CURRENT EDITION) r- 0 z w F- Q Y Q Q F- W m Ir v' O o H U) .006 (D rn cc UCDaz a =ZuWia F- za C) a Ir Q U 0 Q LJ J cy) (n 1� o cz,� Pool CZ �°r- Zr� �� Qo Q Z z w O �� 0 z O Q U Q w O _ w z z a 75 rr O 75 rr O w z cna �Il z_ Lu w U 0 0 00 o w w co o u >0 O z i w m a iii � 0�.`I a o w 06 06 0 A z z � J O i (n W I� Lu W _ I ~ 0 0 a W m 06 (1) Z a J w U) w z O z a U 0 U) m 0 w a_ O Ir a- CE w _ Z O O 4 0 rn c Q y z aQ0 �P�•oGGio ko ;?'i� o AR94880 COMM : WATERSTONE PLAN # 6076 RELEASED: 7/30/21 SHEET A2.2 J cn cn w Ir a- x w cn w 2 O _ z a z a z 0 ATTIC VENTILATION - AT FIRST FLOOR SQ. FT. ATTIC NET FREE AREA NET FREE AREA AREA UPPER ROOF VENTING SOFFIT VENTING 2380 552 SQ. IN. 590 SQ. IN. TOTAL VENTING REQUIRED 1142SQ. IN VENTS REQUIRED 48" TAMCO OFF -RIDGE VENT (138 SI NET FREE) - 4 VENTS NOTE: LOCATE RIDGE VENTS 2'-0" OFF ALL HIPS RIDGES OR VALLEYS, MIN., TYP. R806.23HE MINIMUM NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE VENTED SPACE. EXCEPTION: THE MINIMUM NET FREE VENTILATION AREA SHALL BE 1/300 OF THE VENTED SPACE PROVIDED NOT LESS THAN 40 PERCENT AND NOT MORE THAN 50 PERCENT OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. UNDERLAYMENT APPLICATIONS SHALL BE INSTALLED IN ACCORDANCE WITH SECTION R905.1.1 FOR ASPHALT SHINGLES REFERENCE TO SECTION R905.2 FOR TILE ROOFING REFERENCE TO SECTION R905.3 ROOF PLAN SCALE: 1 /4"=1'-0" r- 0 � LLI Z a cl Y Q Q � W a m Ir 0o� U' co O co a) CC U O a z a W =uwia � Z Z Q a IrQ0C) C0 Q LJ _j rn c/) 1� o cz,rool °r_ cz zr� �� Qo a z z w O �� 0 z O Q U Q w O _ w z z a 2 Ir O 2 Ir O z a z_ 0 M w 1-1 U y 1 � O O O Ir w Lu w m O � O O z i w m�I o Ir a 06 o � 0 z a J O Lu i W I� Lu W I ~ 0 0 Z ,.i i *1 a W i 0 I� 06 Z a J a_ W U) W Z O z a U c7 U 0 w m O Ir w Ir w Z O O 4 0 rn c Q y aQ0 �z �P�•oGGiO z' AR94880 C, Comm WATERSTONE PLAN # 6076 RELEASED: 7/30/21 SHEET A3. 1 J cn cn w Ir m x w cn w 2 O z a z a z O _ EA R-4.1 INSULATION ROOF SHINGLES PER COMMUNITY SPECS. (TYP.) FOYER 12 5 CONCRETE FOOTING SEE STRUCTURAL PLANS 12 5 PRE-ENGINEERED ROOF TRUSSES SEE FRAMING SHEET FOR DETUS f- R-30 INSULATION , BUILDING SECTION SCALE: 1/4"=1'-0" 1 A5.1 onrnc cuinit-i c:c ME= rinnnnni iniiry BUILDING SECTION SCALE: 1/4"=1'-0" 2 A5.1 i BEDROOM 2 T.O. M. T.O. WDW - R-4.1 INSULATION FIN. FLR. IF 7771 1III—III—III=III=LiMhIII � a - -1II—III— III— -11—III—= III=1 I I =1 I I—III—III=1 11- 2 A5.1 ). M. ). WDW ILATION IN. FLR. Comm WATERSTONE PLAN # 6076 RELEASED: 7/30/21 SHEET AS. I cn 0 Z_ Q rr n 06 cn Z Q J W cn W 2 F Z_ cn O w O rr a Ir w O 0 z Q 0 rr a_ cn cn w Ir X w cn w 2 O IE Q z Q z 0 rh -vj� 12 SEE ROOF PLAN INSULATION PER - COMMUNITY SPEC. SEE ENERGY CALCS. 1/2" (MIN.) CLG. BD. - 1 x PT DRAPE BLKG - ABOVE WINDOWS 1/2" G.W.B. WINDOW PER PLAN GYP.BD. WINDOW SILL 1/2" GYP. BD. OVER RADIANT BARRIER INSULATION (R-4.1) ATTACHED TO ix2 PT. FURRING @ 24" O.C. BASE BOARD TYP. 1-STORY WALL SCALE: 1/2" = 1'-O" ATTIC OR SECOND FLOOR LIVING SPACE REFER TO PLANS PROVIDE 2X4 FRAMED ENCLOSURE FOR ELECTRICAL PANEL, FINISH W/ 2" GYPSUM BOARD ELECTRIC METER LOCATION - SEE PLANS. VERIFY INSTALLATION IN FIELD STUCCO FINISH EXTERIOR- CMU BLOCK WALL NOTE: ELECTRICAL PANEL IS TO BE INSTALLED ACCORDING TO ALL APPLICABLE LOCAL, STATE AND NATIONAL CODES. VERIFY PANEL DIMENSIONS PRIOR TO CONSTRUCTION. ROOF SHINGLES OVER TWO LAYERS OF ASTM D226 TYPE II OR SYNTHETIC UNDERLAYMENT COMPLYING WITH ASTM D226 TYPE II INSTALLED PER R905.1.1.1 (SEE SHEET CS2) PRE-ENGINEERED ROOF TRUSSES AT TYP. 24" O.C. BOTTOM CHORD VARIES. REFER TO TRUSS MFGR. DRAWINGS. HURRICANE STRAP EACH END OF TRUSS - REFER TO STRUCTURAL. TOP OF C.M.U. (REFER TO ELEV.) 2x6 ALUM WRAPPED FASCIA BD. WALUM DRIP EDGE SOFFIT INSTALLED PER MANUF. SPECS 2X PT BLOCKING SEE STRUCTURAL PLAN PRECAST WIN. SILL PERIMETER MASONRY SEAT 1 2" BELOW TOP OF SLAB SLOPE GRADE AWAY FROM HOUSE 0'-0" FIN. FL. FOUNDATION PER STRUCTURAL DRAWINGS WINDOW GYPSUM — GYPSUM BOARD BOARD z Q J �3 11/2" z" GYPSUM Ir w GARAGE w BOARD NICHE FOR ELECTRICP PANEL & WIRING N i� ELECTRICAL PANEL ELECTRICP PANEL zo EXTERIOR- 00 CMU BLOCI WALL N ONCRETE CONCRETE CURB REFER CURB REFE TO PLANS TO PLANS CONCRETE - a SLAB ON GRADE _ = = =I GRADE AT GARAGE FLOOR 12 SEE ROOF PLAN 1/2" (MIN.) CLG. BD. (8" TYPE 'X' GYP. BD. TO BE PROVIDED WHEN LIVING SPACE IS ABOVE GARAGE) GARAGE SLAB, SEE STRUCTURAL PLANS SLOPE ROOF SHINGLES OVER TWO LAYERS OF ASTM D226 TYPE II OR SYNTHETIC UNDERLAYMENT COMPLYING WITH ASTM D226 TYPE II INSTALLED PER R905.1.1.1 (SEE SHEET CS2) PRE-ENGINEERED ROOF TRUSSES AT TYP. 24" O.C. BOTTOM CHORD VARIES. REFER TO TRUSS MFGR. DRAWINGS. HURRICANE STRAP EACH END OF TRUSS - REFER TO STRUCTURAL. TOP OF C.M.U. (REFER TO ELEV.) 2x6 ALUM WRAPPED FASCIA BD. w/ALUM DRIP EDGE SOFFIT INSTALLED PER MANUF. SPECS 2X PT BLOCKING SEE STRUCTURAL PLAN 8" CMU BLOCK W/ CEMENTITIOUS FINISH (BEYOND) EXPANSION JOINT DRIVEWAY PER COMMUNITY 4" SPECS SLOPE h 0'-0" _ FIN. FL. WALL SECTION SCALE: 1/2" = 1'-O" ATTIC OR SECOND FLOOR LIVING SPACE REFER TO PLANS T.O. M II I I I I I I I I I I ----- z J � w � I I I I I I I I I I I I I I N 00 N L L 71 ----- 1' R �I , - - - ELECTRICAL PANEL NICHE AT CMU BLOCK WALL SCALE: 1/2" = 1'-O" FOUNDATION PER STRUCTURAL DRAWINGS GARAGE DOOR 12 SEE ROOF PLAN MOISTURE RESISTANT DRYWALL CEILING SEE STRUCTURAL PLANS SLOPE TYP. CMU COLUMN SCALE: 1/2" = 1'-O" NOTE: THESE DETAILS DEPICT ARCHITECTURAL SPECIFICATIONS AND FINISHES ONLY. REFER TO STRUCTURAL DRAWINGS FOR STRUCTURAL INFORMATION ROOF SHINGLES OVER TWO LAYERS OF ASTM D226 TYPE II OR SYNTHETIC UNDERLAYMENT COMPLYING WITH ASTM D226 TYPE II INSTALLED PER R905.1.1.1 (SEE SHEET CS2) PRE-ENGINEERED ROOF TRUSSES AT TYP. 24" O.C. BOTTOM CHORD VARIES. REFER TO TRUSS MFGR. DRAWINGS. HURRICANE STRAP EACH END OF TRUSS - REFER TO STRUCTURAL. TOP OF C.M.U. (REFER TO ELEV.) 2x6 ALUM WRAPPED FASCIA BD. w/ALUM DRIP EDGE SOFFIT INSTALLED PER MANUF. SPECS 2X PT BLOCKING 8" CMU BLOCK W/ CEMENTITIOUS FINISH SLOPE GRADE AWAY FROM HOUSE 0'-0" FIN. FL. FOUNDATION PER STRUCTURAL DRAWINGS LANAI/PORCH Y Q Q � W a m Ir EL O o H w U-)O °o 0 ( cc U O Q Z uj Q Lu =ZcQa za Ir Q U C) Q LJ _j rn D Q z O 1� o cz'rool cz z� Qo . Z z w O ��U)z O Q U w Q O _ Ir w z z t� Q Vl Ir Ir O z Ir 0 w z Q z 0 M u w 1_l U 0 a_ Vl Ir w Ir j co V O j 0 z z w Q In �I � W O z N j Q 0 = 0 W U z Q J O cn ICI w aw 0 0 z Q w 0 W z Q J w W w Z O z IL _ rx _ U U 0 Ir w _ O _ Ir w = Z O O_ 4 cn c Q y aQ0 Awl _ AP�•oGGiO ko � o G%� �6j' :sue �: AR94880 Comm : WATERSTONE PLAN # 6076 RELEASED: 7/30/21 SHEET A5.22 J U) U) w _ _ x w w O z Q z Q z > O _ z Cn T "L" FLASHING SCALE: N.T.S. WOOD SHEATHING 60 MIN. GRADE D PAPER BACKED LATH OVER BARRICADE PLUS WRB (OR APPROVED EQUAL) 8" THICK, 3 COAT CEMENT PLASTER METAL LATH LAP WRB & TAPE OVER ROOF/WALL SCREED 5X5 "L" TYPE CONTINUOUS GALV. METAL FLASHING (NAIL TO ROOF DECK, NOT WALL SHEATHING) ICE AND WATER SHIELD 15" VERTICAL AND 15" DOWN ROOF CAP SHINGLE - DO NOT NAIL, INSTALL WITH ROOF CEMENT ROOF CEMENT SHINGLE ROOFING 4) INSTALL WINDOW OR DOOR. FASTEN PER PRODUCT APPROVALS AND SEAL WINDOW OR DOOR FRAME TO P.T. WOOD BUCK AND MASONRY SEAL EDGE OF P.T. WOOG BUCK TO MASONRY 2) SET P.T. WOOD BUCK OVER CMU WATERPROOFING IN URETHANE SEALANT. FASTEN PER PRODUCT APPROVALS. 3) APPLY LIQUID WATERPROOFING MEMBRANE OVER THE TO AND EXTERIOR FACE OF BUCK AND SILL CMU OPENING WATERPROOFING SCALE: N.T.S. 8" THICK, 3 COAT CEMENT PLASTER 60 MIN. GRADE D PAPER BACKED LATH BARRICADE PLUS WRB (OR APPROVED EQUAL) WRAP LAYERS OF BUILDING WRAP OVER NAILING FLANGE, STOP WRB APPROX. 1-1/2" ABOVE SHINGLES ROOF/WALL SCREED 5X5 WALL FLASHING KICK -OUT FLASHING (SEE DTL. BELOW) FELT UNDERLAYMENT SHINGLE ROOFING FASCIA WRAP DRIP EDGE: OVERLAP 3", EXTEND BELOW SHEATHING, MECH. FASTEN 4" O.C. MAX. KICKOUT SCALE: N.T.S. DETAIL z I;39:11ak 0 FOLD FOLD INWARD @a PT. A 649:11m VAM LQ 641r:11m FOLD @a 45° 770 FOLD INWARD @ PT CREASE @a PT. B CREASE @a PT. C EXTERIOR CMU WALL 1) PROTECTO WRAP LWM200 OR SIMILAR ON WINDOW SILL, JAMBS AND HEAD. APPLY AROUND CORNER AND EXTEND 6" ALL AROUND THE EDGES OF THE WALL PRECAST SILL FOLD INWARD @a PT. A CREASE @a PT. B E,39:llm WATERTIGHT SEAL. FOLD. DO NOT CUT. BOTTOM FLANGE A FOLD INWARD C PT. A CREASE @a PT. B CREASE @a PT. C FOLD PT. C OVER PT. B TILL PT. C TOUCHES BOTTOM FLANGE Comm : WATERSTONE PLAN # 6076 RELEASED: 7/30/21 SHEET GYP i z J cn z O 0 z W Ir D O _ Ir W z z a 2 Ir O 2 rr O z a z 0 w 0 D 0 O _ w Ir w m O O z w a O z_ a 0 06 z a J n w cn w _ c� z a 0 06 U) z a J a_ w w _ z cn V rr w a_ O w _ O 0 z a 0 J w m m x w w O _ z a z a z 0 EA CONC. STOOP LELIA LOAD CALCULATIONS PANEL "A" DESCRIPTION LOAD KVA GENERAL LTG. 3Wx1917 S.F. 5751 SMALL APPLIANCE 1500 SMALL APPLIANCE 1500 REFRIGERATOR 1200 DISHWASHER 2400 DISPOSAL 850 MICROWAVE 1200 RANGE 8000 WATER HEATER 4500 DRYER 5000 WASHER 1500 LAUNDRY 1500 EXTERIOR GFI 1500 IRRIGATION 800 GDO 900 TOTAL KVA 38101 AHU #1 HEAT 10000 KWx.65 6500 FIRST 10KW 10000 BALANCE @ 40% 11240 AC LOAD 6500 TOTAL LOAD 27740 KVA/240V 116 AMPS LOAD CALCULATIONS SCALE: N.T.S. WIRE POLE TRIP DESCRIPTION CKT CKT DESCRIPTION TRIP POLE WIRE #10 2P 30A AIR COMPRESSOR 1 2 RANGE 50A 2P #6 3 4 #6 2P 60A AIR HANDLER 5 6 WATER HEATER 25A 2P #10 7 8 #12 1 P 20A DISHWASHER (AF/GFI) 9 10 DRYER 30A 2P #10 #12 1 P 20A DISPOSAL (AF/GFI) 11 12 #12 1 P 20A WASHER (AF/GFI) 13 14 MICROWAVE (AF) 20A 1 P #12 #12 1 P 20A REFRIGERATOR (AF) 15 16 GENERAL LTG. (AF) 15A 1 P #14 #12 1 P 20A SMALL APPLIANCE (AF/GFI) 17 18 GENERAL LTG. (AF) 15A 1 P #14 #12 1 P 20A SMALL APPLIANCE (AF/GFI) 19 20 GENERAL LTG. (AF) 15A 1 P #14 #12 1 P 20A BATH (GFI) 21 22 GENERAL LTG. (AF) 15A 1 P #14 #12 1 P 20A GARAGE DR. OPENER (GFI) 23 24 GENERAL LTG. (AF) 15A 1 P #14 #12 1 P 20A GARAGE (GFCI) 25 26 GENERAL LTG. (AF) 15A 1 P #14 #12 1 P 20A SPRINKLER SOLENOID 27 28 SPACE #12 1 P 20A EXTERIOR (GFI) 29 30 SPACE SPACE 31 32 SPACE SPACE 33 34 SPACE SPACE 35 36 SPACE SPACE 37 38 SPACE SPACE 39 40 SPACE 150 A METER COMBO 120/240V 1 ph. N3R 22K AIC d150A/2P 2" PVC STUB DOWN FOR FLORIDA POWER & LIGHT #4 GROUND WIRE PANEL SCHEDULE SCALE: N.T.S. 150 A MLO PANEL 42 CIRCUITS N1 3#3/0 AL, 1 #6G 1 %" C 2 GROUND ROD 5%"x8' GALV. ELECT. RISER DIAGRAM SCALE: N.T.S. P.B. FOR .i CHIMES ADD BLOCKING AS REQUIRED GREAT ROOM DINING ADD AREA BLOCKING 9Z AS REQUIRED 5'-1 0" I. ---------r-- ADD'BLOCKING AS REQUIRED VP ENTRY 60" A.F.F. WITH STRUCTURAL BACKING FOR TV WP/ CAT 5 n ' ADD BLOCKING AS REQUIRED OS OWNER'S WIC CAT 5 SUITE E 3-BULB SD FIXTURE m o cs -, REF. VP I I ° CH GFI - - GF UNDER -SINK O 0 SWITCH FOR L BATH DISPOSAL w J 0 n Q U I KITCHEN cHGh BEDROOM 2 Im M I 3 IC7 ---- `D - I IF " I I I EX S HALL ADD BLOCKING 7 BATS BATH P SD AS REQUIRED L 3-BULB FIX O HALL CM CL „ .,, CL EX STE PLUS BEDROOM ADD'BLOCKING AS REQUIRED EX STE PLUS WIC SD W/D SPACE CNDY>> C L 2201V L---- OCMi �o� L WET BAR ADD BLOCKING AS REQUIRED ;AT 5 EX STE PLUS LIVING ROOM D of I I I I SCONNECT ,AUNDRY O co ADD BLOCKING AS REQUIRED STRUCTURED WIRE PANEL BEDROOM 3 (SWP) VERIFY LOCATION IN FIELD 3 T T GFI 48" AFF r ATTIC LIGHT I I - LOCATE MIC OUTLET IN UPP CABS. 69' AFF p PREWIRE FOR GARAGE DOOR N OPENER 0 Fl------------- ------------------------�-1 E I T I ' ELECTRICAL 2 CAR GARAGE PANEL ON \I 2X4 WALL FIRST FLOOR ELECTRICAL PLAN SCALE: 1 /4"=1'-0" WPI GFI A/C DISCONNECT GFI FIELD VERIFY METER WH DISCONNECT IRRIGATION TIMER LOCATION VARIES PER MAIN WATER SERVICE CONNECTION ELECTRICAL KEY DUPLEX CONVENIENCE OUTLET WEATHERPROOF DUPLEX OUTLET F GROUND FAULT INTERRUPTER DUPLEX OUTLET 220 VOLT OUTLET USB COMBO OUTLET WALL SWITCH 3 THREE-WAY SWITCH 14 FOUR-WAY SWITCH KEYLESS LIGHT FIXTURE CEILING MOUNTED LED LIGHT FIXTURE WALL MOUNTED INCANDESCENT LIGHT FIXTURE i0w VAPOR PROOF LIGHT FIXTURE LIGHT FIXTURE WITH PULL CHAIN FLUORESCENT LIGHT FIXTURE (� EXHAUST FAN EXHAUST FAN/LIGHT COMBINATION CH CHIMES (OPTIONAL) p PUSHBUTTON SWITCH (OPTIONAL) COMBINATION SMOKE / CO2 DETECTOR ® SMOKE DETECTOR IQ TELEPHONE (OPTIONAL) TELEVISION (OPTIONAL) DI ELECTRIC METER ELECTRIC PANEL DISCONNECT SWITCH Q JUNCTION BOX /I-- STANDARD ELECTRICAL LINE NOTES: 1. PROVIDE AND INSTALL GROUND FAULT CIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUIT INTERRUPTERS (AFCI) PER 2017 NEC 210.12 2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH FLOOR: SWITCHES ........... 42" OUTLETS.............14" ABOVE COUNTER OUTLETS ...... 46" TELEPHONE ......... 14" TELEVISION .......... 14" 3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS. 4. OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, AND GARAGES, SHALL REQUIRE AFCI PROTECTION. 5. IT IS THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN TO INSURE THAT ALL ELECTRICAL WORK IS IN FULL COMPLIANCE WITH 2O17 NFPA 70, FLORIDA RESIDENTIAL CODE 2020, AND ALL APPLICABLE LOCAL STANDARDS, CODES, AND ORDINANCES. 6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC 406.12. 7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. 8. LUMINIAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED PER THE PROVISIONS OF 2017 NEC 410.16(A) & (B) 9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED 10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS 11. GFCI DEVICES SHALL BE READILY ACCESSIBLE 12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL INFORMATION. 13. PROVIDE THE REQUIRED CLEARANCES AROUND PANELS AND DISCONNECTS IN COMPLIANCE WITH NEC 110.26. 14. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE 0 w z Y a Q � W ¢ m J O Y o~ c� O� 0 rn C)(QZ =z�a F- z¢ ¢ cc Q U o G Q0-1rn W O cN <o 0 gH Z W z rn W COMM : WATERSTONE PLAN # 6076 RELEASED: 7/30/21 SHEET E • J W U) w x w U) w O z ¢ z a z 0 PA 3' 2� PLUMBING RISER DIAGRAM SCALE: N.T.S. 2"VTR JI` AAV SHR CONC_ STOOP SLAB PENETRATION PLAN SCALE: 1 /4"=1'-0" LV V/"111V1V V/"1111LV PER MAIN WATER SERVICE CONNECTION t- 0 z w z ¢ Y Q Q � J ¢ W g m J O Y = o _ Lo 00 O °o 0 iD rn UQ¢z ui 2z(¢ C 3:za ¢ � Q U o (7 Qo-jo) z o o � d � o H J m W n z N I-- m o d a J U) J W J U) z O w m w d 0 z ¢ cc 0 06 z ¢ J n W U) w z_ (D rr w CL rr CL O 0 z F- 13. � v� 0 0 - :�. GOMM WATERSTONE PLAN # 6076 RELEASED: 7/30/21 SHEET pI,I J U) U) w CL x w'^ VJ w 2 O z z Q z O EA