HomeMy WebLinkAboutAPPROVED, REGULATOR SPECS - 8-17-21Bulletin LP-T R122H March 2010 Type R122H First -Stage Regulatcj' Introduction The Type R122H is an Underwriters Laboratories listed regulator designed for Two -Stage LP -Gas systems. The unit is designed to reduce the tank pressure to an outlet pressure of 10 psig. The compact size makes it ideal for small domestic applications and underground tanks. The outlet pressure setting is nonadjustable and is factory set at a nominal 10 psig. Screened drip - lip vents are oriented over the outlet as standard. Features • 20 Year Recommended Replacement Life - The R122H is designed using rugged time proven design concepts and constructed of corrosion resistant materials, both internally and externally. With proper installation and periodic inspection and maintenance the R122H regulator will meet a 20 Year Recommended Replacement Life. • Dual Gauge Taps - Built-in 1/8 inch NPT gauge taps orificed to a number 54 drill size on both the inlet and outlet side of the regulator allow for easy testing. • Durability - A fluorocarbon valve disc is utilized to improve lockup performance in systems with contaminated gas. • Improved Regulation - A large fabric -reinforced diaphragm and stabilizer clip deliver accurate and stable regulation. • Easy Installation - The units compact size and easily accessible inlet and outlet wrench flats make installation easy even in the tightest installations. FISHER Figure 1. Type R 122H Amf-Stage Regurafor Superior Overpressure Protection - The combination of a high capacity relief valve and large vent provide overpressure protection that exceeds UL standards. When used in conjunction with a R622 or R652, the two -stage system will limit the downstream pressure from the second -stage to 2 psig even in a double failure situation. Corrosion -Resistant - Added corrosion resistance from an internal and external coating process for all castings prior to painting, stainless steel relief valve spring and retainer and a corrosion resistant relief valve seat. • Positive Draining Spring Case - When installed property with the spring case vent pointed down, the design allows moisture formed in the spring case to drain out limiting the problems with corrosion and freezing water in the spring case. EMERSON. Process Management Bulletin LP-7: R122H fable t. Ordering Informalron TYPE NUMBER CAPACITY 9TUIMR CONNECTIONS NOMINAL OUTLET SETTING PROPANWI INLET x OUTLET R122H-AA J 1.100.0m 114-etch a 12-IMt1 NPT 10 ps:g (0.69 bar) I Cavacrlq * based on 30 PSIG f2.07 bur) weld w utd 20% droop 1XIB OF Figure 2. Type R 122H Dlmensrons ��s LP4as Equipment Etmwww Process Management Regutator Technotogtes. tnc. USA - Headquarters MdQuwy. Texas 75069.1872 USA Telepttexle: l (800) 56SZ653 Tek*tww: 1 (972) 548-W4 For Wrdw aftmodon visit www fisherreguUms.con0p ltle Ememw htpp is a ovdaMartt w d smveoo marts erl Emerson Eluffle Co. AS add m2 tts are ft properly of Mw Pm3PQ Me awnebs. RMW es a Math awned W Father Coldrofs. Inc.. a MOM of Erne= Process i grtspeM OM The F M I 1 is d Skis putiftom ate Dm5w= fbr vdwmabonw wapom ", sM wnda every e1IbA etas beset Meade to ensure roar aeztaaW, MW are riot b be aanauea as MarranDes Cr e> a: freP�4iegmUbg 1W pro*= or savrees deserted low a Cteu use of spPGeaW". YYa Mlscrve = r4M ro mWft or ut prove ft dealpzte ar at stoat Pe+odtroti at any tntre wtSlloet etob�. Emerson PMCM 1002pemera dot eel assume resPeR09" ror tea selemoM. use or enaasteoance of any praftm Pzspwmww fbr proper lew m . we and enanlist naseo 4 of &W Fsrtor I Peeress hilwap ffdam pMdw mm2ft solarfr VAM dro owe rm" EM ERSON . Process Management Bulletin 71.1:R622 Type R622 Pressure Reducing Regulator • Comp"+ Mori" • Protet Scree 1.11, ,,' �,: Hinh Cnnacity • Inlet and Outlet Pressure Gauge Taps Figure 1 rvpe Re22 Ae.^sure Reducing Repw, r., Introduction Type R622 direct -operated. spring -loaded regulators provide economical pressure reducing control in a variety of residential. commercial, and industrial FISHER - Relief /eight applications. These regulators can be used Both natural. manufactured. or propane gases and have the same inlet and outlet pressure capabilities. e 'e EMERSON. Bulletin 71.1: R622 Specifications 1 Body Size and End Connection Style( I 1 /2 NPT inlet and outlet Maximum Allowable Inlet PressureM Operating: 125 psig (8,6 bar) Emergency: 125 psig (8,6 bar) Except 1.8 to 2.2-inches w.c. (4 to 5 mbar) spring range which has operating and emergency pressures of 60 psig (4,1 bar) Maximum Allowable Outlet (Casing) PressureM Operating to Avoid Internal Part Damage: 3 psid (0.21 bar d) above outlet pressure setting Emergency: 20 psi (1 A bar) Outlet Pressure Ranges See Table 1 Orifice Size 1/84nch (3,2 mm) orifice Flow Coefficients Wide -Open C. for Relief Sizing: 12.5 Wide -Open Cv for Relief Sizing: 0.36 Cl: 35 IEC Sizing Coefficients Xs 0.78 Fo: 0.82 FL: 0.89 Flow Capacities See Table 2 Pressure Registration Internal Relief Performance See Figure 4 Internal Relief Performance Start -to -Discharge is 8 to 22-inches w.c. (20 to 55 mbar) for setpoints from 1.8 to 20-inches w.c. (4 to 50 mbar) Start -to -Discharge is 140 to 200% over setpoint from 20-inches w.c. to 2.2 psig (50 to 152 mbar) Spring Case Vent Connections 3/4 NPT with removable screen Temperature Capabilities(') -200 to 160°F (-29* to 71 °C) Approximate Weight 2.35 pounds (1 kg) Construction Materials Body, Spring Case, Diaphragm Plate, and Orifice: Aluminum Diaphragm, Disk, and O-ring: Nitrile (NBR) Adjusting Screw and Pushpost: Deldn® Closing Cap: ASA Thermoplastic (UV -Ray Resistant) Control Spring: Zinc -plated steel Machine Screw, Spring Seat, and Lever: Zinc -plated steel Valve Stem: Zinc Relief Valve Spring, Relief Spring Retainer, Lever Pin, and Vent Screen: Stainless steel 1. Te � Oft M ozoWtnsBata9pnno be emeoed - Dan* Is a awk owned by E 1. Qu Para de Nwnan and Co In addition, Type R622 regulators have internal relief across the diaphragm to help minimize overpressure. Any outlet pressure above the start -to -discharge point of the non-adjustable relief valve spring moves the diaphragm off of the relief valve seat, allowing excess pressure to bleed out through the screened spring case vent. Table 1. Owlet Pressure Ranges Specifications The Spedficat ons section Bats specifications for Type R822 Pressure Reducing Regulators. As it originally comes from the factory, specifications for a given regulator are stamped on the spring case nameplate. OUTLET PRESSURE RANGE CONTROL SPRING PART NUMBER CONTROL SPRING COLOR CODE SPRING WIRE DIAMETER INCHES (mm) SPRING FREE LENGTH. INCHES (man) 1.8 to 2.24lt M w.c. (4 to S mbar) T 144S3T0012 ftq* 0.051 (1.30) 3.40 (86.4) 5 to 7-tndm w.c. (12 to 17 mbar) T 14398MO12 Orange 0.062 (1.58) 3.40 (86.4) 6.5 to 94penes w.0 (16 to 22 mbar) T 14399T00t2 Yettow 0.067 (1.70) 3.61 (91.7) 9 to 134d1es w.c. (22 to 32 mbar) T 14400T0012 S11M 0.072 (1.83) 4.10 (104) 13 to 204ndtes w.c. (32 to 50 mbar) T t4401 T0012 Gray 0 060 (7-03) 3.60 (91.4) 16 to 354nches w.c. (40 to 87 mbar) T 14402T0012 Pat11 0.093 (2.36) 3.S2 (89.4) 1 to 2.2 psig (69 t0 152 mbar) Tt4403T0012 LkPI Bare 0 105 (2.67) 3.66 (93.0)