Loading...
HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONS"Building Our Quality Reputation One Customer At ATime" Information Owner: DONALD & SANDRA BETHEL Address: 7904 LAKELAND BLVD FORT PIERCE, FL 34951 SCC131150472 ildin2 Information Wind Zone: 170 MPH, Exposure Category: C Minimum Building Dimension: 27 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening IFLocation Number Zone 1[7Width Device (in) IFHeight Device (in) Device Elevation (M Max Positive Pressure (psI) Max Negative Pressure (psi) 1 Int 24 12 7 37.8 -41.0 2 Int 24 49 7 37,8 -41.0 3 Int --- 51 _ 27 7 37.8 -41.0 _.._ 4 Int_._.__._ _ 51 36 7 37.2 -40.4WW 5.. Int 24 12 7 37.8 -41.0 6 Int 24 49 7 37.8 -41,0 7 Int 24_ _. 61 7 37.8 -41.0 uu` S Int 24 61 7 37.8 -41.0 9 End 35 61 7 36.8 -48.7 10 End 35 61 7 36.8 -48.7 11 End 51 bl 7 35.9 -46.8 Prepared in accordance with: ASCE 7-16, Chaplet- 30. Wind Loads - Components and Cladding. 71h Edition (2020) Florida Building Code, Page I of I