HomeMy WebLinkAboutstate approvalFor Department use Dnly LReceived te Received From q A, S� DOH Operating Permit# 56-60-00179 STATE OF FLORIDA DEPARTMENT OF HEALTH NOTICE OF RESURFACING OF PUBLIC SWIMMING 'S'Ptt 1. ProjectlFacility Name= Ae9ency Island Dunes County: St, Lucie Address of Pool 8640 South Ocean Drive CityJense_ n Reach Zip: 34957 2. Owner Name Regency Island Dunes regency8640@the- E-Mail: regency.com Phone:7(72) 229-0311 Mailing Address: 8640 South Ocean Drive Jensen Bch City: StateFL ZIp:34957 3. Building Depart. Name: St. Lucie County Building Dept, Mailing Address: 2300 Virginia Avenue City.Ft.pierce State: F 34949 E-Mail. _EL p Phone: (772 j 462-1553 4. Contractor Name: AquaticHSudraces of Treasure Coas �_� rCPC #: 145911 0 E-Mail: dh.a uatic@ ail.com Phone: (72) 225-4389 5. Public Pool Resurfacing Building Code Compliance Check List: �— Lip of the gutter leveled to within 114 inch (6.4 mm) between the highest and lowest point and the downward slope from the lip to the drain must be maintained as originaify designed ar increased, net to exceed new construction standards. (Florida Building Code (FBC) section 454. 1.10. 1-1) Tile step markings installed per requirements of Section 454.1.2.5.3. (FBC 454.1.10.1.2) Note: when markings are specified by Code to be dark,. the four. Must be slip resistant [oo, term dark" shall mean a Wnsell color value from zero to Where applicable, the slope brsak marking must be installed meeting the requirements of Section 454 1.2.2.3.2 and a safety line installed 2 feet (610 mm) before the marking. (FBC 454.1.10.1.3) Depth markers and NO DIVING markers installed in accordance with Section 464.1 2 3. (FBC 454 1, 10.1.4) The pool ladder must have a 3 to 6-Inch (76 to 152 mm) clearance from the pool wall. New cross -braced ladder(s) shall be installed in place of non -crass -braced ladders) in Conformance with Section 464.1.2 5 1. (FBC 454. 1. 10. 1.6) Note: Ensure Florida Building Code 454. 1. 10.4-2 Equipotenbal bonding has been inspected and Veered by jurisdictional building authority. - Should resurfacing works affect the step riser heights, no riser shall exceed 12 Inches 1305 mm) for pools and for spas, and the intermediate risers shall be made uniform. (FBC 464. 1. 10. 1,6) NDTE: the i2-inch ailowance for pool step riser is a code modification the Building Commission has approved for the -inc FBC revision. 7e edition.2020 Step treads that protrude from the pool wall shall be removed and replaced with a cross -braced ladder or reconstructed to meet the requirements of Section 454.1.2.5.1 or 454.1.2.5.2. (FBC 454.1.10.1.7) Note Ensure Florida Building Code 454.1 10.4.2 Equipotentiel bonding has been inspected and vented by jurisdictional building authority. lH Resurfacing NotMloation Form. 12/30/2019. RVI9 84E-0.001, F.A.0 Page 1 Of 2 6. Note Florida Building Code section 454.1.2.4 Color. Pool floors and webs shall be white or light pastel in color and shall have the characteristic of reflecting rather than absorbing light. The interior finish coating floors and walls shall be comprised of a nonpigmented white oementitious binder component together with a sandleggregate component. The finish coating she# have a dry lightness level (CIE C value) of 80. 0 or greater and a wet luminous reflectance value (CIE Y value) of 50.0 or greater, as determined by test results provided by the manufacturer. utilizing testing methodology from American Standard ASTM 04086, ASTM El477, ASTM E1347, pools constructed of flbelglass, thermoplastic, or stainless steel shall be subject to the same interior finish color requirements. Pool Interior Finish Color Selection (print or type on line below). Sky Blue Replacement Tile Color Set®coon (print or type on line below) -- N/A Note. If suction outlet drain covers, sumps or other an&entrapment safety features are replaced, provide DON with completed D144 f 57 form finders. 514.0315, Florida Statutes. Notes if deck alterations are in the scope of work. the wet deck must be maintained as onginally approved or meet current Florida Building Code ADA requirements. REMARKS: Install FL Gem Finish "— "thick Bring all Main Drain Covers to Code CERTIFICATION OF OWNER The undersigned owner, or owner's representative, hereby agrees to operate the pool described in this notification in accordance with the requirements of Chapter 514 of the Florida Statutes, and Chapter 64E-9 of the Florida Administrative Code (F.A.C.), and maintain the original or the resurfaced construction compliant with the Florida Building Code (FBC), Building, Chapter 4, section 454.1 that is approved or accepted by the Jurisdictional building department. The undersigned owner, or owner's representative, further agrees to comply with the requirements of the FRC Chapter 4 Section 454.1,10.1 when undertaking the resurfacing project herein described. Sign: l An JL � -- Date: Gn e, Name: l .i�55�'Q I YSIJi� Tine W—I (Q m t1fA ' Q Y IPnnt or typal (vrint ortypel H net owner, attach Authorization From Owner THIS SECTION FOR DOH USE ONLY: It is recommenced that the above resurfacing notification be( �APPROVED( )DENIED, subject to rovislons of the F.A.C. and the faC Signatu �jOH Engineered Staff Dale Print or [yPe Name DH Resurfacing NotReation Form, f2)3012019. Rule edE-a.001, F,A.G. Page 2 of 2