Loading...
HomeMy WebLinkAboutAPPROVED SGD(1)6/2/2021 Florida Building Code Online u Professional Regulation BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links I Search I b a k r 1I I— -product Approval I,,USER: Public User Product Aooroval Menu > Product or Application Search > Application List > Application Detail FL # FL14605-R11 Application Type Editorial Change Code Version 2020 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Eastern Architectural Systems Address/Phone/Email 16341 Domestic Ave. Ft. Myers, FL 33912 (800)432-2204 Ext4305 jflesher@easternmetal.com Authorized Signature James Flesher jflesher@easternmetal.com Technical Representative Jim Flesher Address/Phone/Email 10030 Bavaria Rpad Fort Myers, FL 33913 (800)432-2204 jflesher@easternmetal.com Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sliding Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2011 ASTM E1886 2012 ASTM E1996 2012 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL14605 R11 Equiv FL14605 AAMA EQ_pdf FL14605 R11 Equiv FL14605 ASTM EQ.pcf hUps://www.floridabuilding.org/prlpr app_dti.aspx?param=wGEVXQwtDgsw8ZVNfe8A7UJNIxUeoVLg8PZOCwjUExwuV°/a2fcmrlCVtA%3d°/a3d 1/5 6/2l2021 Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option A O5/19/2021 O5/19/2021 05/21/2021 FL # Model, Number or Name Description 14605.1 Series 623 Impact Vinyl SGD Series 623 Impact Vinyl SGD Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14605 Rll C CAC NI011134-R3.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes O5/31/2024 Design Pressure: +50.0/-50.0 Installation Instructions Other: Maximum Size: 144" x 96" 3 Panel Bypass, 2-Track. FL14605 Rii II 08-01671B.pdf FRAME MATERIAL TO BE RIGID PVC FROM DECEUNINCK Verified By: Luis R. Lomas, P.E. 62514 NORTH AMERICA AAMA CERTIFIED (DEP-1) Created by Independent Third Party: Yes Evaluation Reports FL14605 R11 AE 5123516.pdf Created by Independent Third Party: Yes 14605.2 Series 623 Impact Vinyl SGD Series 623 Impact Vinyl SGD Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14605 Ril C CAC NI011134.01-R2.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes O5/31/2025 Design Pressure: +50.0/-50.0 Installation Instructions Other: Maximum Size: 192" x 96" 4 Panel Bypass, 2- FL14605 Ril II 08-01670A.Ddf Track.FRAME MATERIAL TO BE RIGID PVC FROM DECEUNINCK Verified By: Luis R, lomas, P.E. 62514 NORTH AMERICA AAMA CERTIFIED (DEP-1) Created by Independent Third Party: Yes Evaluation Reports FL14605 R11 AE 512350B.pdf Created by Independent Third Party: Yes 14605.3 � Series 623 Non -Impact Vinyl SGD Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50.0/-50.0 Other: Maximum Size: 144" x 96" 3 Panel Bypass, 2-Track. FRAME MATERIAL TO BE RIGID PVC FROM DECEUNINCK NORTH AMERICA AAMA CERTIFIED (DEP-1) 14605.4 (Series 623 Non -Impact Vinyl SGD Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50.0/-50.0 Other: Maximum Size: 192" x 96" 4 Panel Bypass, 2-Track. FRAME MATERIAL TO BE RIGID PVC FROM DECEUNINCK NORTH AMERICA AAMA CERTIFIED (DEP-1) 14605.5 Series FD8100 Impact Aluminum SGD Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See drawing for Design Pressures. Maximum 4 Panels, Multi -Track, Bypass. GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE FOR EASTMAN INTERLAYERS Series 623 Non -Impact Vinyl SGD Certification Agency Certificate FL14605 Rll C CAC NI011134.02-R2.pdf Quality Assurance Contract Expiration Date 04/30/2024 Installation Instructions FL14605 Ril II 08-01673A.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14605 Rll AE 5123538.pdf Created by Independent Third Party: Yes Series 623 Non -Impact Vinyl SGD Certification Agency Certificate FL14605 Rll C CAC NI011134.03-R4.pdf Quality Assurance Contract Expiration Date 04/30/2024 Installation Instructions FL14605 Rll II 08-01672A.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14605 Rll AE 5123526.pdf Created by Independent Third Party: Yes Series FD8100 Impact Aluminum SGD Certification Agency Certificate FL14605 Rll C CAC NI009416.02-R3.pdf FL14605 Rll C CAC NI009416.03-R3.pdf Quality Assurance Contract Expiration Date 06/30/2024 Installation Instructions FL14605 Rll II 08-026736.pdf Verified By: luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A7UJNIxUeoVLg8PZOCwjUExwuV%2fcmrlCVtA%3d%3d 2/5 6/2/2021 Florida Building Code Online Evaluation Reports FL14605 R11 AE 513448C.pdf Created by Independent Third Party: Yes 14605.6 Series FD8100 Impact Aluminum Series FD8100 Impact Aluminum SGD SGD Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14605 R11 C CAC NI009021.01-R3.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 05/31/2024 Design Pressure: +90/-90 Installation Instructions Other: Maximum 5 Panels, Multi -Track, Bypass, with and FL14605 R11 II 08-02674A .pdf without Pockets. GLASS INTERLAYER COMPLIES WITH THE Verified By: Luis R. Lomas, P.E. 62514 REQUIREMENTS OF THE FLORIDA BUILDING CODE Created by Independent Third Party: Yes ACCORDING TO MIAMI-DADE FOR EASTMAN INTERLAYERS Evaluation Reports FL14605 R11 AE 513449B.pdf Created by Independent Third Party: Yes 14605.7 Series FD8100 Impact Aluminum Series FD8100 Impact Aluminum SGD 135deg SGD 135deg Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14605 R11 C CAC NI010632-R5.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 10/31/2024 Design Pressure: +50/-50 Installation Instructions Other: Maximum 8 Panels, Multi -Track, Bypass, 135deg. FL14605 R11 II 08-02669A .pdf Corner, with and without pockets. GLASS INTERLAYER Verified By: Luis R. Lomas, P.E. 62514 COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA Created by Independent Third Party: Yes BUILDING CODE ACCORDING TO MIAMI-DADE FOR EASTMAN Evaluation Reports INTERLAYERS FL14605 R11 AE 513444B.pdf Created by Independent Third Party: Yes 14605.8 Series FD8100 Impact Aluminum Series FD8100 Impact Aluminum SGD 135deg or 90deg SGD 135deg or 90deg Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14605 R11 C CAC NI009044.01-117.pdf Approved for use outside HVHZ: Yes FL14605 R11 C CAC NI009044.02-R2.pdf Impact Resistant: Yes FL14605 R11 C CAC NI009044.03-112.pdf Design Pressure: N/A FL14605 R11 C CAC NI010632.01-113.pdf Other: See Drawing for Design Pressures. Maximum 8 Panels, FL14605 R11 C CAC NI010632.02-R2.pdf Multi -Track, Bypass, 135deg Corner, 90deg. Corner with and FL14605 R11 C CAC NI010632-RS.pdf without Pockets. Insulated Impact or Impact Only Glass. Quality Assurance Contract Expiration Date GLAZING "B" WHEN INSTALLED IN THE HVHZ TO BE 05/31/2024 INSTALLED AT 30' OR LESS ABOVE GROUND LEVEL. GLASS Installation Instructions INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE FL14605 R11 II 08-02732A .pdf FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE FOR Verified By: Luis R. Lomas, P.E. 62514 EASTMAN INTERLAYERS Created by Independent Third Party: Yes Evaluation Reports FL14605 R11 AE 513516B.pdf Created by Independent Third Party: Yes 14605.9 Series FD8100 Impact Aluminum Series FD8100 Impact Aluminum SGD 90deg SGD 90deg Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14605 R11 C CAC NI009044.01-R7.p,df Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 05/31/2024 Design Pressure: +60/-60 Installation Instructions Other: Maximum 8 Panels, Multi -Track, Bypass, 90deg. FL14605 R11 II 08-02670A .pdf Corner, with and without pockets. GLASS INTERLAYER Verified By: Luis R. Lomas, P.E. 62514 COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA Created by Independent Third Party: Yes BUILDING CODE ACCORDING TO MIAMI-DADE FOR EASTMAN Evaluation Reports INTERLAYERS FL14605 R11 AE 513445B.pdf Created by Independent Third Party: Yes 14605.10 Series FD8100 Impact Aluminum Series FD8100 Impact Aluminum SGD with 5'0 Panels SGD with 5'0 Panels Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14605 R11 C CAC NI009416.04-R3.pdf Approved for use outside HVHZ: Yes FL14605 R11 C CAC NI009416.05-R3.pdf Impact Resistant: Yes FL14605 R11 C CAC NI009416.06-R4.pdf Design Pressure: N/A Quality Assurance Contract Expiration Date Other: See drawing for Design Pressure. Maximum 4 Panels, 05/31/2024 Multi -Track, Bypass with 5'0 Panels. GLAZING "C" WHEN Installation Instructions INSTALLED IN THE HVHZ TO BE INSTALLED AT 30' OR LESS FL14605 R11 II 08-02672A .pdf ABOVE GROUND LEVEL. GLASS INTERLAYER COMPLIES WITH Verified By: Luis R. Lomas, P.E. 62514 THE REQUIREMENTS OF THE FLORIDA BUILDING CODE Created by Independent Third Party: Yes ACCORDING TO MIAMI-DADE FOR EASTMAN INTERLAYERS Evaluation Reports https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A7UJNIxUeoVLg8PZOCwjUExwuV°/a2fcmriCVtA%3d%3d 3/5 6/2/2021 Florida Building Code Online FL14605 Rll AE 5134478.Ddf Created by Independent Third Party: Yes 14605.11 Series FD8100 Non -Impact Series FD8100 Non -Impact Aluminum SGD Aluminum SGD Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14605 Rll C CAC NI009021.02-RS.pdf Approved for use outside HVHZ: Yes FL14605 Ril C CAC NI009021.03-RS.pdf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +70/-70 O5/31/2024 Other: Maximum 5 Panels, Multi -Track, Bypass, with and Installation Instructions without Pockets. FL14605 R31 II 08-02671.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14605 Rll AE 513446A.Ddf Created by Independent Third Party: Yes 14605.12 Series FD8100 Non -Impact Series FD8100 Non -Impact Aluminum SGD 135deg Aluminum SGD 135deg Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14605 R11 C CAC NI010633.01-R2.pdf Approved for use outside HVHZ: Yes FL14605 R11 C CAC NI010633-R3.pdf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +50/-50 12/31/2024 Other: Maximum 8 Panels, Multi -Track, Bypass, 135deg Installation Instructions Corner, with and without Pockets. FL14605 R11 II 08-02668.odf Verified By: Uis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14605 Rll AE 513443A.odp Created by Independent Third Party: Yes 14605.13 Series FWI 6000 Impact Aluminum Series FWI 6000 Impact Aluminum SGD SGD Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14605 Rll C CAC NI006179.01-R3.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/30/2024 Design Pressure: +80/-80 Other: Maximum 4 Panels, Multi -Track, Bypass. GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE Installation Instructions FL14605 Rll II 08-02676A .pdf Verified By: Luis R. Lomas, P.E. 62514 FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE FOR EASTMAN INTERLAYERS Created by Independent Third Party: Yes Evaluation Reports FL14605 Ril AE 513451B.pdf Created by Independent Third Party: Yes 14605.14 Series FWI 6000 Impact Aluminum Series FWI 6000 Impact Aluminum SGD SGD Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14605 RS1 C CAC NI009448.02-Rl.pdf Approved for use outside HVHZ: Yes. Quality Assurance Contract Expiration Date Impact Resistant: Yes 10/31/2024 Design Pressure: +45/-45 Installation Instructions Other: Maximum 3 Panels, Multi -Track, Bypass, with and FL14605 Rll II 08-02734.Ddf without Pockets. Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL14605 Rll AE 513518A.Ddf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32394 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Cop�ght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, FS. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click ere . https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A7UJNIxUeoVLg8PZOCwjUExwuV%2fcmr1CVtA%3d%3d 4/5 6/2/2021 Florida Building Code Online Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A7UJNIxUeoVLg8PZOCwjUExwuV%2fcmr1CVtA%3d%3d 5/5 L. Roberto Lomas P.E. 1432 Woodford Rd. Lewisville, NC 27023 434-688-0609 Manufacturer: Eastern Architectural Systems 16341 Domestic Ave. Fort Myers, FL 33912 Engineering Evaluation Report Product Line: Series FD8100 Aluminum Sliding Glass Door 2 Track- Impact Report No.: 513449B Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a). The product listed herein complies with requirements of the Florida Building Code. Supporting Technical Documenfation: 1. Approval document: drawing number 08-02674, revision A, prepared, signed and sealed by Luis Roberto Lomas P.E. 2. Test Report No.: NCTL 210-3407-1A signed and sealed by Gerard J. Ferrara, P.E. National Certified Testing Laboratories, Orlando, FL AAMA/W DMA/CSA 101 /I.S.2/A440 Design pressure: ±90.Opsf Water resistance: With 1.675" Sill Riser = 6.Opsf With 2.675" Sill Riser = 10.45psf With 3.675" Sill Riser = 15.Opsf ASTM E1886/ E1996 Large Missile Impact, Level D, Wind Zone 4 Cyclic Load Test, ±90.0psf design pressure 3. Test report No.: NCTL 210-3407-1 signed and sealed by Gerard J. Ferrara, P.E. National Certified Testing Laboratories, Orlando, FL TAS 201 Large Missile Impact Test, Level D, Wind Zone 4 TAS 202 Uniform Static Air Pressure, ±90.Opsf design pressure, 15.0psf water penetration. Water resistance: With 1.675" Sill Riser = 6.Opsf With 2.675" Sill Riser = 10.45psf With 3.675" Sill Riser = 15.Opsf TAS 203 Cyclic Pressure loading ±90.0.Opsf design pressure 4. Anchor calculations, report number 513448-1A, prepared, signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: • Maximum design pressure: ±90.Opsf • Maximum panel size: 49 • Units must be glazed per ASTM E1300 according to glazing details in approval drawing. • This product is rated to be used in the HVHZ. • This product is impact resistant and does not require impact protection in wind borne debris regions. • Frame material to be extruded Aluminum 6063-T6. Installation: Units must be installed in accordance with manufacturer's installation instructions and approval document 08-02674, revision Al Certification of Independence: Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the products) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other entity involved in the approval process of the listed product(s). 2/ �`�,� •�,�c E N %Y cps 0000 4*�TA7 4F s�ONA��E����� Luis R. Lomas, P.E. FL No.: 62514 10/19/2020 NOTICE OF PRODUCT CERTIFICATION CERTfgCgTi x N M 1 �9nAEo PFOpJG CERTIFICATION NO: DATE: CERTIFICATION PROGRAM: COMPANY: CODE: REVISION DATE: NI009021.01-R3 04/13/2011 Structural Eastern 1783-1 08/05/2020 To verify that the "Notice of Product Certification" is valid, please visit www.NAMICertification.com to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Eastern Architectural Systems Series "FD-8100" Aluminum 16341 Domestic Avenue Impact Rated Sliding Glass Door Ft. Myers, FL 33912 Configuration: OXXXX Glazing: Laminate-3/16"Heat Strengthened Glass/0.100 "So lutia/3/16"Heat Strengthened Glass Frame: W-5994mm(236") H-3048nnn(120") Panel: W-12571n1n(49.5") H-2998mm(118") SPECIFICATION PRODUCT RATING AAMA/WDMA/CSA 101/1*S.2/A440-05 SD-C90 5994 x 3048 (236 x 120) TAS201/202/203-94 Design Pressure: +90/-90 psf ASTM E1886-02/E1996-02 Large Missile Impact Rated Wind Zone 4-Missile Level D Product Tested By: National Certified Testing Laboratories Report No: NCTL-210-3407-1 & 210-3407-1A Expiration Date: May 31, 2024 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 4. ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 5. FRAME MATERIAL: EXTRUDED ALUMINUM 6063—T6. 6. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 2 FOR GLASS DETAILS. 7. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. S. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #14 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 7/16" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 10. FOR ANCHORING INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 11. FOR ANCHORING TROUGH FRAME INTO METAL STRUCTURE USE #14 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SHEET NO. NOTES ELEVATION 3 — 1 TABLE OF CONTENTS DESCRIPTION REVISIONS DESCRIPTION DATE APPROVED REVISED PER NEW REQUIREMENTS 01/09/18 R.L. 12. ALL FASTENERS TO BE CORROSION RESISTANT. 13. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3.192 PSI. C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 5063—T5 .062" THICK MINIMUM EASTERN ARC Easetern FISION OF RM& NRSANLPPSL 1-1CMSCAVE■ a=.....o...n un.. DCRM— F1 DiN-mYSTEMS SERIES FD8100 ALUMINUM IMPACT RATED SLIDING GLASS DOOR — 2 TRACK NOTES DRAWN: DWG NO. I REV V.L. 08-02674 A SCALE NTS IDATE 03/30/15 1 SHEET 1 OF 6 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NO 27023 434-688-0609 rl/omas@lrlomaspe.com SIGNED: 0110912018 P.- i IL/o����i, 'ljq i Luis R. Lomas P.E. FL No.: 62514 236" MAX FRAME WIDTH 6" MAX � 13" MAX O.C. 6" MAX REVISIONS DESCRIPTION DATE I APPROVED REVISED PER NEW REQUIREMENTS 01/09/18 1 R.L 6" MAX ll L_ 15" MAX 7/16" O.C. 3/16" HS �— X X X X 100 PVB BY EASTMAN 120" MAX MAX � �—I/ => � � 3/16" HS FRAME EXTERIOR INTERIOR HEIGHT BULB GASKET WEDGE GASKET 3C10 BY MPI 2541 BY MPI FPVC FPVC 65 DUROMETER 75 DUROMETER STRUCTURAL SEALANT SIKAFLEX 552 1 SETTING BLOCK (30096) BITE 85 DUROMETER Allj Al CENTRAL RUBBER L ZEXTRUSIONS GLAZING DETAIL 6" MAX SERIES FD8100 N12 TRACK ALUMINUM ALUMINUM SLIDING GLASS DOOR EXTERIOR VIEW UNITS UP TO 5 PANELS IN UNLIMITED CONFIGURATIONS ARE APPROVED AS LONG AS INDIVIDUAL PANEL AREA DOES NOT EXCEED 40.56 P72 WITH 1.675" SILL RISER WITH 2.675" SILL RISER WITH 3.675" SILL RISER DESIGN PRESSURE RATING IMPACT RATING +40.0%90.OPSF LARGEANDSMALL MISSILE IMPACT MISSILE LEVEL D, WIND ZONE 4 & HVHZ DESIGN PRESSURE RATING IMPACT RATING f7O.O/ 9O.OPSF LARGE AND SMALL MISSILE IMPACT MISSILE LEVEL D, WIND ZONE 4 & HVHZ NOTES: 1. (1) 1" X 3/16" WEEP SLOT 6" FROM EACH END, AND 48" ON CENTER THROUGH VERTICAL SILL LEG EXCEPT MOST INTERIOR SILL LEG. 2. PANEL SIZE: 49 1/2" X 115" 3. D.L.O.: 40 7/8" X 109 1/4" DESIGN PRESSURE RATING IMPACT RATING +90.OPSF LARGEANDSMALL MISSILE IMPACT MISSILE LEVEL D, WIND ZONE 4 & HVHZ EASTERN MCRITECTIIRAL SYSTEMS �4 I Eastern EASTERN —AL SUPPLY .e. 1E]I1 DOMESTIC— �L FORT MYERS. F-12 ,_._ _.." "e.. Eoo4xz SERIES FD8100 ALUMINUM IMPACT RATED SLIDING GLASS DOOR — 2 TRACK ELEVATION V.L. 08-02674 SCALE NTS I 1— 03/30/15 SHE-2 OF 6 L ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NO 27023 434-666-0609 rllomas@lrlomaspe.com SIGNED: 0110912018 STAT 5E OF •�� ���'c�t► 0R10P• NA 11E�C���\ Luis R. Lomas P.E. FL No.: 62514 REVISIONS REV DESCRIPTION DATE APPROVED EDGE DrIS MI EDGE DIISTIANCE IN A REVISED PER NEW REQUIREMENTS 01/09/16 R.L WOOD FRAMING OR 2X BUCK BY OTHERS 1 7/16" MIN, 1/4" MAX. BACKER ROD 1 7/16" MIN. EMBEDMENT r SHIM SPACE & A LLAANTT EMBEDMENT SEA5/8" MIN. EDGE DISTANCE 1/4" MAX. SHIM SPACE INTERIOR #14 WOOD #14SCREW SCR WOOD sa n _ n SCREW 5/8" MIN. EDGE DISTANCE EXTERIOR INTERIOR EXTERIOR WOOD FRAMING BACKER ROD OR 2X BUCK & APPROVED BY OTHERS SEALANT #14 WOOD JAMB INSTALLATION DETAIL BACKER ROD SCREW WOOD FRAMING OR 2X BUCK INSTALLATION & APPROVED SEALANT 1/4" MAX. WOOD FRAMING SHIM SPACE OR 2X BUCK BY OTHERS 1 7/16" MIN. NOTES: EMBEDMENT Y. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY, 2, PERIMETER AND JOINT SEALANT BY OTHERS TO BE 5/8" MIN. 5/8" MIN, DESIGNED IN ACCORDANCE WITH ASTM E2112 EDGE DISTANCE EDGE no VERTICAL CROSS SECTION SIGNED: 0110912018 WOOD FRAMING OR 2X BUCK INSTALLATION F.ASiF.RN PADIVISION DHNECNOF EMS 11111 1p EasternTLSIIPPLY `�\;� R• LONFORT NYM, R=12 � J pEN • 44 /ter - 1_.-e. wi..ee... _"M �.,e.. eaw2z-zzw ` �,•�\ SF .� i SERIES FD8100 ALUMINUM IMPACT RATED 41TAT 0151SLIDING GLASS DOOR — 2 TRACKMIN CM4 INSTALLATION DETAILS �0 OFto . DRAWN: DWG NO, REV �i�t`S �COR10P VALE DATE 08 502674 A /�/�S*/ONA 11 �\\�` NTS 03/30/15 3 OF 6 L ROBERTO LOMAS P.E. LUIS R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE, NO 27023 FL No.: 62514 434-MB-0609 r1lomas@Irlomaspe.com 5/8" MIN EDGE DISTANCE METAL STRUCTURE BY OTHERS DISTANCEEDGE � SHIM SPACE \7 OR BACKER ROD J rllj u & APPROVED Sul SEALANT #14 SMS OR ILAXLJ H SELF DRILLING SCREWS EXTERIOR i I � INTERIOR lIIIIS�11117 � � • - F�JI BACKER ROD SCREWS & APPROVED SEALANT 1/4 MAX, SHIM SPACE METAL STRUCTUR BY I I 61 OTHERS •� • • • DISTANCE VERTICAL •IMETAL STRUCTURE INSTALLATION I METAL STRUCTURE BY OTHERS 5/8" MIN. EDGE DISTANCE #14 SMS OR SELF DRILLING SCREWS 5/8" MIN. EDGE DISTANCE REVISIONS REV DESCRIPTION DATE APPROVED A REVISED PER NEW REQUIREMENTS 1 01/09/16 1 R.L r SHIM SPACE INTERIOR EXTERIOR BACKER ROD & APPROVED SEAIANIT TAI JAMB INSTALLATION DE METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 01/09/20i8 EASTERN ARONm ION OF SYSTEMS '• Eastern 1Sat OOMES'LINCIU SUPPLY \`\`�;� 1R IIC 0/, . w._.. wwe..._.. _..n o.+a.. FORT MYERS,R=12 ` Q •E •--•/999,9 �i �4 \'Mao NSF ,cP SERIES FD8100 ALUMINUM IMPACT RATED*• 0 61 k� SLIDING GLASS DOOR 2 TRACK — �� INSTALLATION DETAILS ��0 , TAT OF DRAWN: DWG N0. REV �i��'cFs'clpR►OQ' SCALE DATE 08 sOEE674 A//�j&/ONAL1�?\\\� NTS 03/30/15 4 OF 6 L. ROBERTO LOMAS P.E. LUIS R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE, NO 27023 FL No.: 62514 434-666-0609 rllomas@Irlomaspe.com 1 1/2" MIN. EDGE DISTANCE CONCRETE/MASONRY BY OTHERS OPTIONAL 1X BUCK TO BE PROPERLY SECURED SEE NOTE 3 SHEET 1 BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT OPTIONAL 1 X BUCK TO BE PROPERLY SECURED SEE NOTE 3 SHEET 1 CONCRETE/MASONRY BY OTHERS 2 1/2" SEPARATION 1 1/2" MIN. EDGE DISTANCE 1 1/4" MIN. �',:4• EMBEDMENT ^ � ^ 1/4" MAX. SHIM SPACE 1/4" TAPCON INTERIOR 1/4" TAPCON " "�� �� L�" " 1/ 1 /4" MAX. N II I � SHIM SPACE . . a' . ,; � 1 1/4" MIN. a:' . � EMBEDMENT 1 1/2" MIN. 1 1/2" MIN. EDGE DISTANCE EDGE DISTANCE 2 1 /2" SEPARATION VERTICAL CROSS SECTION CONCRETE/MASONRVINSTALLATIQN REVISIONS REV DESCRIPTION DATE APPROVED A REVISED PER NEW REQUIREMENTS 01/09/18 R.L 1 1/4" MIN. EMBEDMENT CONCRETE/MASONRY BY OTHERS 1 1/2" v• MIN. ,.'.,,':; EDGE DISTANCE 1 �; �.: 2 1/2" ' SEPARATION .' ' 1 •b �:e '. 1 1/2" MIN. EDGE DISTANCE OPTIONAL 1X BUCK TO BE PROPERLY SECURED SEE NOTE 3 SHEET 1 1 /4" MAX. SHIM SPACE 1/4" TAPCON INTERIOR �- BACKER ROD & APPROVED SEALANT JAMB INSTALLATION DETAIL CONCRETE/MASONRYINSTALLATIQN NOTES: 1. INTERIORAND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 EASTERN MCNRECTURRL SYSTEMS �� Eastern EASTERN METK SUPPLY �ea�i ooMEsricnvE FORT MYERS. FL Yt013 ,...w. w�wew..,�� oam.. BOPN]2-]20/ SERIES FD6100 ALUMINUM IMPACT RATED SLIDING GLASS DOOR - 2 TRACK INSTALLATION DETAILS DRAWN: DWG NO. V.L. 08-02674 SCALE NTS D^TE 03/30/15 SHEEP cJ OF 6 L. ROBERTD LOMAS P.E 1432 WOODFORD RD LEW/SVILLE, NC 27023 434-683-0609 rllomasOa lrlomaspe.com SIGNED: 01/09/2018 �\\\JCS 1R I ILIC'�,����i v,.���ENSF'9s''i S(TVyA�T°fE OF �_i� REv i�jFs,cpRlv'. G\�� Luis R. Lomas P.E. FL No.: 62514 IA/TFRI/lR FYTFR!/l R #10 WOOD SCREW 1 1/4" MIN. EMBEDMENT 1i�L�Z�I�y:7_151PLN OR 2X BUCK BY OTHERS 1/4" MAX 1/2" MIN . SHIM SPACE EDGE DISTANCE HOOK INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION REVISIONS REV DESCRIPTION DATE APPROVED INTERIOR A REVISED PER NEW REQUIREMENTS 01/09/18 R.L. #10 SMS OR SELF DRILLING SCREWS EXTERIOR \_ M t I AL STRUCTURE BY OTHERS 1/4" MAX 1/2" MIN, SHIM SPACE EDGE DISTANCE HOOK INSTALLATION DETAIL METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 01/09/2018 FA5IERN MCNIDIVISION OF SYSTEMS 1j111 I'1 a� 1 Eastern mczcm=10M1 ooMERN METAL AVE MYE20912 SUPPLY \\\\`\\\V\ R, LIO//' ` F P <. FORTRS,FL�N J �• GEN •o 49 4! i...... w......... ..... ova.. S064SZ.yrDl \/••\\ S•� i SERIES FD8100 ALUMINUM IMPACT RATED*• 0,�6 b1 k= SLIDING GLASS DOOR — 2 TRACK =,� INSTALLATION DETAILS TAT OF DRAWN: DWG NO, JA cPs'c�OR1�Q: SCALE DATE 08 02674 ///,s/ONA 11�?\\\\ NTS 03/30/15 1 SHEET 6 OF 6 L. ROBERTO LOMAS P.E LUIS R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE, NC27023 FL No.: 62514 434-688-0609 r/lomas@Irlomaspe.com