Loading...
HomeMy WebLinkAboutAPPROVED ENERGY LOT 29(1)FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KHOV-LELIA Builder Name: KHOVNANAIN HOMES Street: 5101 ARMINA PLACE Permit Office: City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: LELIA MODEL LOT 29 @ WATERSTONE Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 } 1. New construction or existing New (From Plans) 10. Wall Type$1844.9 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1508.90 ft2 3. Number of units, if multiple family 1 b. Frame - Wood. Adjacent R=11.0 336.00 ft2 c. NIA R= ft2 4. Number of Bedrooms 4 d. NIA R_ ft2 5. Is this a worst case? No 11. Ceiling Types (1917.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1917.00 ft2 6. Conditioned floor area above grade (ft2) 1917 b. NIA R= ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 7. Windows(201.8 sgft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.28 159.83 ft2 a. Sup: Attic, Ret: LAUNDRY, AH: LAUNDRY 6 250 SHGC: SHGC=0.30 b. U-Factor: Dbi, U=0.55 42.00 ft2 13. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.34 a. Central Unit 35.2 SEER:16.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 1.570 ft. 14. Heating systems kBtulhr Efficiency Area Weighted Average SHGC: 0.308 a. Electric Strip Heat 32.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA 9. Floor Types (1917.1 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1917.10 ft2 b. Conservation features EF: 0.950 b. NIA R= ft2 None c. NIA R= ft2 16. Credits Pstat Glass/Floor Area: 0.105 Total Proposed Modified Loads: 59.66 PASS Total Baseline Loads: 61.14 hereby certify that the plans and sp ifications covered by this Review of the plans and �R THE S�',��, calculation are in compliance wit he Florid Energy specifications covered by this Code. calculation indicates compliance! PREPARED BY: with the Florida Energy Code. Before construction is completed u '" DATE: this building will be inspected for compliance with Section 553.908 Le I hereby certify that this building, as designed, is in compliance Florida Statutes.,r� with the Florida Energy Code. G'(h) WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 7/13/2021 8:06 AM EnergyGauge D USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page I of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPO PROJECT Title: KHOV-LELIA Building Type: User Owner Name: LELIA MODEL LOT 29 @ WA # of Units: 1 Builder Name: KHOVNANAIN HOMES Permit Office: Jurisdiction: Famiiy Type: Detached New/Existing: New (From Plans) Comment: Bedrooms: 4 Conditioned Area: 1917 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No CLIMATE Address Type: Street Address Lot # Block/Subdivisiom PlatBook: Street: 5101 ARMINA PLACE County: St. Lucie City, State, Zip: FORT PIERCE, FL, Design Temp Int Design Temp Heating Design Daily Temp V design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1917 16614.7 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 EXT STE LIV PLUS 199 1765.1 No 0 4 1 No Yes Yes 2 WIC STE PLS BED 25 220 No 0 1 No Yes Yes 3 EX STE PLUS BED 132 1161.6 No 0 1 No Yes Yes 4 EX STE BATH 54 475.2 No 0 1 No Yes Yes 5 FOYER 81 712.8 No 0 1 No Yes Yes 6 HALL BATH 54 475.2 No 0 1 No Yes Yes 7 LAUNDRY 77 677.6 No 0 1 No Yes Yes 8 BED 3 126 1108.8 No 1 1 No Yes Yes 9 BED 2 126 1109 No 1 1 No Yes Yes 10 KIT GREAT RM DI 672 5644.8 No 0 1 No Yes Yes 11 M BATH 95 836 No 0 1 No Yes Yes 12 MASTER SUITE 210 1848 No 2 1 No Yes Yes 13 MASTER WIC 66 580.8 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio EXT STE LIV PL 46 ft 0 199.3 ft2 _--- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC STE PLS BE 4.5 ft 0 25 ftZ ---- 0 1 0 3 Slab -On -Grade Edge Insulatio EX STE PLUS B 8.5 ft 0 132 W _--- 0 1 0 4 Slab -On -Grade Edge Insulatio EX STE BATH 1 ft 0 54 ftZ -___ 1 0 0 7/13/2021 8:06 AM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FUHM K4U5-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulatio FOYER 19 ft 0 81.3 ft2 --__ 1 0 0 6 Slab -On -Grade Edge Insulatio HALL BATH 1 ft 0 54 ft2 ---_ 1 0 0 7 Slab -On -Grade Edge Insulatio LAUNDRY T5 ft 0 77 ft2 1 0 __-- 0 8 Slab -On -Grade Edge Insulatio BED 3 22.5 ft 0 126 ft2 ---- 0 1 0 9SIab-On-Grade Edge Insulatio BED 2 12.5 ft 0 126 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio KIT GREAT RM 43.5 ft 0 672 ft2 ---- 1 0 0 11 Slab -On -Grad e Edge Insulatio M BATH 9 ft 0 94.5 ft2 __-- 1 0 0 12SIab-On-Grade Edge Insulatio MASTER SUITE 28 ft 0 210 ft2 ____ 0 1 0 13SIab-On-Grade Edge Insulatio MASTER WIC 6 ft 0 66 ft2 ---- 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2076 ft2 0 ft2 Medium N 0.9 No 0.9 No 0 22.6 ATTIC / v # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1917 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) EXT STE LIV PL 30 Blown 199 ft2 0.1 Wood 2 Under Attic (Vented) WIC STE PLS BE 30 Blown 25 ft2 0.1 Wood 3 Under Attic (Vented) EX STE PLUS B 30 Blown 132 ft2 0.1 Wood 4 Under Attic (Vented) EX STE BATH 30 Blown 54 ft2 0.1 Wood 5 Under Attic (Vented) FOYER 30 Blown 81 ft2 0.1 Wood 6 Under Attic (Vented) HALL BATH 30 Blown 54 ft2 0.1 Wood 7 Under Attic (Vented) LAUNDRY 30 Blown 77 ft2 0.1 Wood 8 Under Attic (Vented) BED 3 30 Blown 126 ft2 0-1 Wood 9 Under Attic (Vented) BED 2 30 Blown 126 ft2 0.1 Wood 10 Under Attic (Vented) KIT GREAT RM 30 Blown 672 ft2 0.1 Wood 11 Under Attic (Vented) M BATH 30 Blown 95 ft2 0.1 Wood 12 Under Attic (Vented) MASTER SUITE 30 Blown 210 ft2 0A Wood 13 Under Attic (Vented) MASTER WIC 30 Blown 66 ft2 0.1 Wood 7/13/2021 8:06 AM EnergyGaugeQ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below a 1 SE Exterior Concrete Block - Int InsEXT STE LIV 4.1 11 7 9 4 108.1 ft2 0 0 0.5 0 2 SW Exterior Concrete Block - Int InsEXT STE LIV 4A 15 4 10 0 153.3 ft2 0 0 0.5 0 3 SW Exterior Concrete Block - Int InsiflX STE PLU 4.1 7 8 10 0 76.7 W 0 0 0.5 0 4 SE Exterior Concrete Block - Int InsuI FOYER 4.1 6 4 9 4 59.1 ft2 0 0 0.5 0 5 SW Exterior Concrete Block - Int Insul FOYER 4.1 11 4 10 0 113.3 W 0 0 0.5 0 6 NE Exterior Concrete Block- Int Insul BEd 3 4.1 11 7 9 4 108.1 ft2 0 0 0.5 0 7 NE Exterior Concrete Block- Int Insul BEd 2 4.1 11 7 9 4 108.1 f12 0 0 0.5 0 8 SW Exterior Concrete Block - Int InsiKIT GREAT 4.1 25 2 10 0 251.7 ft2 0 0 0.5 0 9 NW Exterior Concrete Block - Int InsiKIT GREAT 4.1 15 1 9 4 140.8 ft2 0 0 0.5 0 10 NE Exterior Concrete Block - Int Insul M BATH 4A 8 9 9 4 81.7 ftz 0 0 0.5 0 11 NE Exterior Concrete Block - Int InsMASTER SUI 4.1 14 1 9 4 131.4 ft2 0 0 0.5 0 12 NW Exterior Concrete Block - Int InsMASTER SUI 4.1 13 1 9 4 122.1 ft2 0 0 0.5 0 13 NW Exterior Concrete Block - Int InsWASTER WI 4.1 5 10 9 4 54.4 ft2 0 0 0.5 0 14 NW Garage Frame - Wood KIT GREAT 11 36 0 9 4 336.0 ftZ 0 0 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SW Insulated EXT STE LIV None .39 3 2 6 8 21.1 ft2 2 SW Insulated EXT STE LIV None .39 3 2 6 8 21.1 ft2 3 NW Wood KIT GREAT None .39 3 2 6 8 21.1 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SE 1 Metal Double (Tinted) Yes 0.28 0.3 N 22.9 ft2 1 ft 0 in 1 ft 0 in None None 2 SW 3 Metal Double (Tinted) Yes 0.28 0.3 N 23.0 ft2 6 ft 0 in 1 ft 0 in None None 3 SW 5 Metal Double (Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 4 NE 6 Metal Double (Tinted) Yes 0.28 0.3 N 15.0 W 1 ft 0 in 1 ft 0 in None None 5 NE 7 Metal Double (Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 6 SW 8 Metal Double (Tinted) Yes 0.28 0.3 N 23.0 ftz 1 ft 0 in 1 ft 0 in None None 7 NW 9 Metal Double (Tinted) Yes 0.28 0.3 N 23.0 ft2 1 ft0 in 1 ft 0 in None None 8 NW 9 Metal Double (Tinted) Yes 0.55 0.34 N 42.0 ft2 1 ft 0 in 1 ft 0 in None None 9 NW 12 Metal Double (Tinted) Yes 0.28 0.3 N 22.9 ft2 1 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wali Perimeter Avg. Wall Height Exposed Wall Insulation 1 380 ft2 380 ft2 64 ft 8 ft 1 7/13/2021 8:06 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000385 1938A 106.35 199.65 .1304 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPI 32 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitl Split Singl SEER: 16 35.2 kBtulhr cfm 0.81 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # 1/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Coon 1 Attic 6 250 ft2 LAUNDRY 1 ft2 Default Leakage LAUNDRY (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Heating Jan �Xj Jan Feb Feb Mar X� Mar�Xj A r ArMayJun Ma Jul Jul Jun rl rl Au �xjAu�Xj Se Oct Sep Oct Nov Nov ki j Dec Xj Dec Venting Jan [ Feb t X Mar Apr [ May Jun Jul Aug Se [ Oct Nov [ ] Dec 7/13/2021 8:06 AM EnergyGauge@ USA 7.0.00 - FiaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHFCKLIST RFPOPT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 58 68 68 68 68 68 68 68 66 66 Heating (VVFH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibslsq.ft. 0 ft2 Oft 0.3 BED 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC BED 2 Default(8 Ibslsq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN DINING Default(8 Ibslsq.ft. ft2 ft 0.3 GREAT ROOM Default(8 Ibslsq.ft. ft2 ft 0.3 FOYER Default(8 Ibslsq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibslsq.ft. ft2 ft 0.3 M WIG Default(8 Ibslsq.ft. ft2 ft 0.3 M TIOLET Default(8 Ibs/sq.ft, ft2 ft 0.3 M BATH Default 8 Ibsls .ft. ft2 ft 0.3 MASTER SUITE 7/13/2021 8:06 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Dbl, U=0.28 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.34 c. U-Factor: NIA SHGC: d. U-Factor: NIA SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): NIA SHGC(AVG): NIA 9. Floor Types a. Slab -On -Grade Edge Insulation b. NIA c. NIA 5101 ARMINA PLACE, FORT PIERCE, FL, New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 1508.90 ft2 b. Frame - Wood; Adjacent R=11.0 336.00 ft2 1 c. NIA R= ft2 4 d. NIA R= ft2 No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1917.00 ft2 1917 b. NIA R= ft2 Area c. NIA R= ft2 159.83 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: LAUNDRY, AH: LAUNDRY 6 250 42.00 ft2 13. Cooling systems kBtuthr Efficiency ft2 a. Central Unit 35.2 SEER:16.00 ft2 1.570 ft. 0.308 Area ft2 Insulation Area R=0.0 1917.10ft2 R= ft2 R= ft2 14. Heating systems a. Electric Strip Heat 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: kBtu/hr Efficiency 32.0 COP:1.00 Cap: 50 gallons EF: 0,95 Pstat �0,>TA�� VA {� drr7r`"�s�w"n'' OD *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/13/2021 8:05 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1