HomeMy WebLinkAboutAPPROVED ENERGY LOT 29(1)FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KHOV-LELIA
Builder Name: KHOVNANAIN HOMES
Street: 5101 ARMINA PLACE
Permit Office:
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: LELIA MODEL LOT 29 @ WATERSTONE
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 }
1. New construction or existing New (From Plans)
10. Wall Type$1844.9 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1508.90 ft2
3. Number of units, if multiple family 1
b. Frame - Wood. Adjacent
R=11.0 336.00 ft2
c. NIA
R= ft2
4. Number of Bedrooms 4
d. NIA
R_ ft2
5. Is this a worst case? No
11. Ceiling Types (1917.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1917.00 ft2
6. Conditioned floor area above grade (ft2) 1917
b. NIA
R= ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft2
7. Windows(201.8 sgft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.28 159.83 ft2
a. Sup: Attic, Ret: LAUNDRY, AH: LAUNDRY 6 250
SHGC: SHGC=0.30
b. U-Factor: Dbi, U=0.55 42.00 ft2
13. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=0.34
a. Central Unit
35.2 SEER:16.00
c. U-Factor: NIA ft2
SHGC:
Area Weighted Average Overhang Depth: 1.570 ft.
14. Heating systems
kBtulhr Efficiency
Area Weighted Average SHGC: 0.308
a. Electric Strip Heat
32.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) NIA ft2
15. Hot water systems
SHGC(AVG): NIA
9. Floor Types (1917.1 sqft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1917.10 ft2
b. Conservation features
EF: 0.950
b. NIA R= ft2
None
c. NIA R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.105 Total Proposed Modified Loads: 59.66
PASS
Total Baseline Loads: 61.14
hereby certify that the plans and sp ifications covered by
this
Review of the plans and
�R THE S�',��,
calculation are in compliance wit he Florid Energy
specifications covered by this
Code.
calculation indicates compliance!
PREPARED BY:
with the Florida Energy Code.
Before construction is completed
u '"
DATE:
this building will be inspected for
compliance with Section 553.908
Le
I hereby certify that this building, as designed, is in compliance
Florida Statutes.,r�
with the Florida Energy Code.
G'(h) WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection
Checklist in accordance with R402.4.1.1
and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
7/13/2021 8:06 AM EnergyGauge D USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page I of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPO
PROJECT
Title:
KHOV-LELIA
Building Type:
User
Owner Name:
LELIA MODEL LOT 29 @ WA
# of Units:
1
Builder Name:
KHOVNANAIN HOMES
Permit Office:
Jurisdiction:
Famiiy Type:
Detached
New/Existing:
New (From Plans)
Comment:
Bedrooms:
4
Conditioned Area:
1917
Total Stories:
1
Worst Case:
No
Rotate Angle:
0
Cross Ventilation:
No
Whole House Fan:
No
CLIMATE
Address Type:
Street Address
Lot #
Block/Subdivisiom
PlatBook:
Street:
5101 ARMINA PLACE
County:
St. Lucie
City, State, Zip:
FORT PIERCE,
FL,
Design Temp
Int Design Temp
Heating
Design Daily Temp
V
design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days
Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area Volume
1
Entire House
1917 16614.7
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
1
EXT STE LIV PLUS
199 1765.1
No
0
4
1
No
Yes
Yes
2
WIC STE PLS BED
25 220
No
0
1
No
Yes
Yes
3
EX STE PLUS BED
132 1161.6
No
0
1
No
Yes
Yes
4
EX STE BATH
54 475.2
No
0
1
No
Yes
Yes
5
FOYER
81 712.8
No
0
1
No
Yes
Yes
6
HALL BATH
54 475.2
No
0
1
No
Yes
Yes
7
LAUNDRY
77 677.6
No
0
1
No
Yes
Yes
8
BED 3
126 1108.8
No
1
1
No
Yes
Yes
9
BED 2
126 1109
No
1
1
No
Yes
Yes
10
KIT GREAT RM DI
672 5644.8
No
0
1
No
Yes
Yes
11
M BATH
95 836
No
0
1
No
Yes
Yes
12
MASTER SUITE
210 1848
No
2
1
No
Yes
Yes
13
MASTER WIC
66 580.8
No
0
1
No
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
EXT STE LIV PL 46 ft
0
199.3 ft2
_---
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC STE PLS BE 4.5 ft
0
25 ftZ
----
0 1
0
3 Slab -On -Grade Edge Insulatio
EX STE PLUS B 8.5 ft
0
132 W
_---
0 1
0
4 Slab -On -Grade Edge Insulatio
EX STE BATH 1 ft
0
54 ftZ
-___
1 0
0
7/13/2021 8:06 AM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
FUHM K4U5-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulatio
FOYER 19 ft
0
81.3 ft2
--__
1
0
0
6 Slab -On -Grade Edge Insulatio
HALL BATH 1 ft
0
54 ft2
---_
1
0
0
7 Slab -On -Grade Edge Insulatio
LAUNDRY T5 ft
0
77 ft2
1
0
__--
0
8 Slab -On -Grade Edge Insulatio
BED 3 22.5 ft
0
126 ft2
----
0
1
0
9SIab-On-Grade Edge Insulatio
BED 2 12.5 ft
0
126 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio
KIT GREAT RM 43.5 ft
0
672 ft2
----
1
0
0
11 Slab -On -Grad e Edge Insulatio
M BATH 9 ft
0
94.5 ft2
__--
1
0
0
12SIab-On-Grade Edge Insulatio
MASTER SUITE 28 ft
0
210 ft2
____
0
1
0
13SIab-On-Grade Edge Insulatio
MASTER WIC 6 ft
0
66 ft2
----
0
1
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Composition shingles 2076 ft2
0 ft2 Medium
N
0.9
No 0.9
No 0
22.6
ATTIC
/
v
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1917 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
EXT STE LIV PL
30
Blown
199 ft2
0.1
Wood
2 Under Attic (Vented)
WIC STE PLS BE
30
Blown
25 ft2
0.1
Wood
3 Under Attic (Vented)
EX STE PLUS B
30
Blown
132 ft2
0.1
Wood
4 Under Attic (Vented)
EX STE BATH
30
Blown
54 ft2
0.1
Wood
5 Under Attic (Vented)
FOYER
30
Blown
81 ft2
0.1
Wood
6 Under Attic (Vented)
HALL BATH
30
Blown
54 ft2
0.1
Wood
7 Under Attic (Vented)
LAUNDRY
30
Blown
77 ft2
0.1
Wood
8 Under Attic (Vented)
BED 3
30
Blown
126 ft2
0-1
Wood
9 Under Attic (Vented)
BED 2
30
Blown
126 ft2
0.1
Wood
10 Under Attic (Vented)
KIT GREAT RM
30
Blown
672 ft2
0.1
Wood
11 Under Attic (Vented)
M BATH
30
Blown
95 ft2
0.1
Wood
12 Under Attic (Vented)
MASTER SUITE
30
Blown
210 ft2
0A
Wood
13 Under Attic (Vented)
MASTER WIC
30
Blown
66 ft2
0.1
Wood
7/13/2021 8:06 AM EnergyGaugeQ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing
Solar Below
a
1
SE
Exterior
Concrete Block - Int InsEXT STE LIV
4.1 11
7
9
4
108.1 ft2
0
0
0.5
0
2
SW
Exterior
Concrete Block - Int InsEXT STE LIV
4A 15
4
10
0
153.3 ft2
0
0
0.5
0
3
SW
Exterior
Concrete Block - Int InsiflX STE PLU
4.1 7
8
10
0
76.7 W
0
0
0.5
0
4
SE
Exterior
Concrete Block - Int InsuI FOYER
4.1 6
4
9
4
59.1 ft2
0
0
0.5
0
5
SW
Exterior
Concrete Block - Int Insul FOYER
4.1 11
4
10
0
113.3 W
0
0
0.5
0
6
NE
Exterior
Concrete Block- Int Insul BEd 3
4.1 11
7
9
4
108.1 ft2
0
0
0.5
0
7
NE
Exterior
Concrete Block- Int Insul BEd 2
4.1 11
7
9
4
108.1 f12
0
0
0.5
0
8
SW
Exterior
Concrete Block - Int InsiKIT GREAT
4.1 25
2
10
0
251.7 ft2
0
0
0.5
0
9
NW
Exterior
Concrete Block - Int InsiKIT GREAT
4.1 15
1
9
4
140.8 ft2
0
0
0.5
0
10
NE
Exterior
Concrete Block - Int Insul M BATH
4A 8
9
9
4
81.7 ftz
0
0
0.5
0
11
NE
Exterior
Concrete Block - Int InsMASTER SUI
4.1 14
1
9
4
131.4 ft2
0
0
0.5
0
12
NW
Exterior
Concrete Block - Int InsMASTER SUI
4.1 13
1
9
4
122.1 ft2
0
0
0.5
0
13
NW
Exterior
Concrete Block - Int InsWASTER WI
4.1 5
10
9
4
54.4 ft2
0
0
0.5
0
14
NW
Garage
Frame - Wood KIT GREAT
11 36
0
9
4
336.0 ftZ
0
0
0.5
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
SW
Insulated EXT STE LIV
None
.39
3
2
6 8
21.1 ft2
2
SW
Insulated EXT STE LIV
None
.39
3
2
6 8
21.1 ft2
3
NW
Wood KIT GREAT
None
.39
3
2
6 8
21.1 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
SE 1
Metal Double (Tinted) Yes
0.28 0.3
N
22.9 ft2
1 ft 0 in
1 ft 0 in
None
None
2
SW 3
Metal Double (Tinted) Yes
0.28 0.3
N
23.0 ft2
6 ft 0 in
1 ft 0 in
None
None
3
SW 5
Metal Double (Tinted) Yes
0.28 0.3
N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
4
NE 6
Metal Double (Tinted) Yes
0.28 0.3
N
15.0 W
1 ft 0 in
1 ft 0 in
None
None
5
NE 7
Metal Double (Tinted) Yes
0.28 0.3
N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
6
SW 8
Metal Double (Tinted) Yes
0.28 0.3
N
23.0 ftz
1 ft 0 in
1 ft 0 in
None
None
7
NW 9
Metal Double (Tinted) Yes
0.28 0.3
N
23.0 ft2
1 ft0 in
1 ft 0 in
None
None
8
NW 9
Metal Double (Tinted) Yes
0.55 0.34
N
42.0 ft2
1 ft 0 in
1 ft 0 in
None
None
9
NW 12
Metal Double (Tinted) Yes
0.28 0.3
N
22.9 ft2
1 ft 0 in
1 ft 0 in
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wali Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
380 ft2 380 ft2
64 ft
8 ft
1
7/13/2021 8:06 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000385
1938A 106.35 199.65 .1304
7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity
Block Ducts
1
Electric Strip Heat/
None
COPI 32 kBtulhr
1 sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block Ducts
1
Central Unitl
Split
Singl SEER: 16 35.2 kBtulhr cfm
0.81 1 sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt
Conservation
1
Electric None
Garage
0.95 50 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model # Area
Volume FEF
None
None
ft2
DUCTS
/ ---- Supply ----
---- Return ----
Air
CFM 25 CFM25
HVAC #
1/ # Location R-Value Area
Location Area
Leakage Type
Handler
TOT OUT QN
RLF
Heat Coon
1 Attic 6 250 ft2
LAUNDRY 1 ft2
Default Leakage
LAUNDRY
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling
Heating
Jan
�Xj Jan
Feb
Feb
Mar
X� Mar�Xj
A r
ArMayJun
Ma
Jul
Jul
Jun rl
rl
Au
�xjAu�Xj
Se Oct
Sep Oct
Nov
Nov
ki
j Dec
Xj Dec
Venting
Jan
[ Feb
t
X Mar
Apr
[ May
Jun
Jul
Aug
Se
[ Oct
Nov
[ ] Dec
7/13/2021 8:06 AM EnergyGauge@ USA 7.0.00 - FiaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHFCKLIST RFPOPT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
58
68
68
68
68
68
68
68
66
66
Heating (VVFH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibslsq.ft.
0 ft2
Oft
0.3
BED 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC BED 2
Default(8 Ibslsq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
DINING
Default(8 Ibslsq.ft.
ft2
ft
0.3
GREAT ROOM
Default(8 Ibslsq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibslsq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibslsq.ft.
ft2
ft
0.3
M WIG
Default(8 Ibslsq.ft.
ft2
ft
0.3
M TIOLET
Default(8 Ibs/sq.ft,
ft2
ft
0.3
M BATH
Default 8 Ibsls .ft.
ft2
ft
0.3
MASTER SUITE
7/13/2021 8:06 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows" Description
a. U-Factor: Dbl, U=0.28
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.34
c. U-Factor: NIA
SHGC:
d. U-Factor: NIA
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): NIA
SHGC(AVG): NIA
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. NIA
c. NIA
5101 ARMINA PLACE, FORT PIERCE, FL,
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1508.90 ft2
b. Frame - Wood; Adjacent
R=11.0
336.00 ft2
1
c. NIA
R=
ft2
4
d. NIA
R=
ft2
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1917.00 ft2
1917
b. NIA
R=
ft2
Area
c. NIA
R=
ft2
159.83 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: LAUNDRY, AH: LAUNDRY
6 250
42.00 ft2
13. Cooling systems
kBtuthr
Efficiency
ft2
a. Central Unit
35.2 SEER:16.00
ft2
1.570 ft.
0.308
Area
ft2
Insulation Area
R=0.0 1917.10ft2
R= ft2
R= ft2
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
kBtu/hr Efficiency
32.0 COP:1.00
Cap: 50 gallons
EF: 0,95
Pstat
�0,>TA��
VA
{� drr7r`"�s�w"n''
OD
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/13/2021 8:05 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1