HomeMy WebLinkAboutProduct Review AffidavitPlanning & Development Services Department
Building & Regulations Division
Product Review Affidavit
Building Permit # _ i 70 y — Qb/8 Owners Name 6#0 & 2adycJvo� �oro. Applicant:
O N
RECEI"-,O A =Z114A40
Product
Opening Design
Pressures
Product Rated
Design Pressure
Manufacturer
Model Number
Product Approval
Number
Glass
Type
Method of Attachment u. 6 U)
Z
Z -j
Windows
+31.9/ -34.7
+/-55
MI WINDOWS
FL 17499.6
NON IMPACT
3/16" TAPCONS W/ 1-1/4" MIN. EM apil 1, C
Mullions
37.7
+/-54
MI WINDOWS
FL 15353
NONIMPACT
1/4" TAPCONS W/ 1-1/4" M10-EDBE15 �t
Fixed Glass
+33.4 / -36.3
+/- 55
MI WINDOWS
FL 15349.1 R-8
NONIMPACT
3/16" TAPCONS W/ 1-1/4" MIN. EMBED @ 12"
Block Glass
Skylights
—B
Sliding Glass Doors
+28.4 / -31.3
+/-
MI WINDOWS
12080
FL 15332.3 R-3
NONIMPACT
3/16" TAPCONS W/ 1-1/4" EMBED C
Swing Type Doors
+29.9 / -32.7
+/-50
THERMA TRU
2880
FL-7630.2 R-5
SGL. IMPACT
1/4" TAPCONS W/ 1-1/4" MIN.
French Doors
Garage Doors
+28.4 / -34.7
+39.2 / -43.7
WAYNE DALTON
9100
FL-9174.10 R11
N/A
5/16" x 1-5/8" LAG SCREW EA. BRACKET
Hurricane Protection
37.7
+49.0 / -56.0
"URRICANE=1MPANELMAI
16293-Rl
N/A
1/4"-20x3/4" S.S. KNURLED STUDS 12-112" O.C. TOP & BTM
Roof Ventilation
Roofing Material
-83.4 PSF
-172 PSF
EAGLERCOPINGPRGDUCTS
BEL-AIR CONC. TILE
NOA NO. 16-0314.06
N/A
(2) 10d RING SHANK NAILS
Revised 07/22/2014
I have reviewed the above components or cladding and I have approved their use in this structure. These products provide
wind loads and forces specified by current code provisions.
Name: ��(3 4jj/(��/j Signature:
Design Prof: 00/v 4L.D : /VV gz� Cert. No. 3-2d le [o • Date: L/ /7-9
C
4 k
0