Loading...
HomeMy WebLinkAboutEnergy Calculation Form & Manual J's a• FORM R405-2014 NFLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: BISCAYNE GRAN DE_eCLASSIC_MDW 44 Builder Name: GHO Homes Street: 2694 Conifer Dr Permit Office: City,State,Zip: Ft Pierce, FL, 34951 Permit Number: Owner: GHO Homes Jurisdiction: Design Location: FL,VERO_BEACH_MUNICIPAL ARPT County:: Indian River(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1975.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1748.40 ft2 b. Frame-Steel,Adjacent R=11.0 227.11 ft2 i3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 2 • d. N/A R= ft2 10.Ceiling Types (1954.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic(Vented) R=30.0 1954.00 ft2 t6. Conditioned floor area above grade(ft2) 1954 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. N/A R= ft2 11.Ducts R ft2 7. Windows(255.3 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 394.2 a. U-Factor: Dbl, U=0.49 164.31 ft2 SHGC: SHGC=0.24 b. U-Factor: Dbl, U=0.50 72.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a.Central Unit 36.0 SEER:16.00 c. U-Factor: Dbl, U=0.46 19.00 ft2 SHGC: SHGC=0.26 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Strip Heat 36.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 5.962 ft. Area Weighted Average SHGC: 0.244 14.Hot water systems 8. Floor Types (1954.0 sqft.) Insulation Area a. Electric Cap:50 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1954.00 ft2 b. Conservation features b. N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.131 Total Proposed Modified Loads: 60.30 PASS Total Baseline Loads: 63.13 I hereby certify that the plans and specifications covered by Review of the plans and 0 'EKE STATE this calculation are in compliance with the Florida Energy specifications covered by this 0 Code. calculation indicates compliance with the Florida Energy Code. ti rrrur•�, , l:�•;-' PREPARED Y: C Before construction is completed DATE: this building will be inspected for - compliance with Section 553.908 * G I hereby certify that this- d n as i ned, is in com liance Florida Statutes. t with the Florida Energy Co . g g p COD Wm�� y OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. P 3/29/2017 4:10 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 0 o arY Page 1 of 5 FORM R405-2014 PROJECT Title: BISCAYNE GRANDE_eCLAS Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1954 Lot# Owner: GHO Homes Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: GHO Homes Rotate Angle: 180 Street: 2694 Conifer Dr Permit Office: Cross Ventilation: County: Indian River Jurisdiction: Whole House Fan: City,State,Zip: Ft Pierce, Family Type: Single-family FL, 34951 NewlEAsting: New(From Plans) Comment: CLIMATE } / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,VERO BEACH_MUN FL VERO_BEACH_MUNI 2 45 90 70 75 299 64 Medium BLOCKS Number Name Area Volume 1 Blockl 1954 18230.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1954 18230.8 Yes 3 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 211.66 ft 0 1954 ft2 0.6 0 0.4 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Flat tile/slate 2185 ft2 0 ft2 Medium 0.75 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1954 ft2- N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1954 ft2 0.11 Wood 3/29/2017 4:10 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 S=>N Garage Frame-Steel Main 11 22 4 9 4 208.4 ft2 0.23 0.01 0 1+ 2 W=>E Garage Frame-Steel Main 11 2 0 9 4 18.7 ft2 0.23 0.01 0 _3 S=>N Exterior Concrete Block-Int Insul Main 4.1 15 4 9 4 143.1 ft2 0 0.600000 0 4 E=>W Exterior Concrete Block-Int Insul Main 4.1 6 8 9 4 62.2 ft2 0 0.600000 0 5 S=>N Exterior Concrete Block-Int Insul Main 4.1 7 4 9 4 68.4 ft2 0 0.600000 0 _ 6 E=>W Exterior Concrete Block-Int Insul Main 4.1 44 10 9 4 418.4 11:2 0 0.600000 0 7 N=>S Exterior Concrete Block-Int Insul Main 4.1 14 2 9 4 132.2 ft2 0 0.600000 0 - 8 W=>E Exterior Concrete Block-Int Insul Main 4.1 8 4 9 4 77.8 ft2 0 0.600000 0 9 NW=>SE Exterior Concrete Block-Int Insul Main 4.1 2 10 9 4 26.4 ft2 0 0.600000 0 10 N=>S Exterior Concrete Block-Int Insul Main 4.1 12 8 9 4 118.2 ft2 0 0.600000 0 _11 E=>W Exterior Concrete Block-Int Insul Main 4.1 11 2 9 4 104.2 ft2 0 0.600000 0 a 12 N=>S Exterior Concrete Block-Int Insul Main 4.1 15 4 9 4 143.1 ft2 0 0.600000 0 _13 W=>E Exterior Concrete Block-Int Insul Main 4.1 48 8 9 4 454.2 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S=>N Wood Main None .14 2 8 8 21.3 ft2 2 S=>N Insulated Main None .14 3 8 24 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 180 degrees). / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E=>W 4 Metal Low-E Double Yes 0.49 0.24 8.3 ft2 2 ft 0 in 1 ft 6 in Drapes/blinds ' None 2 S=>N 3 Metal Low-E Double Yes 0.49 0.24 30.0 ft2 1 ft 0 in 1 ft 6 in Drapes/blinds None 3 S=>N 5 Metal Low-E Double Yes 0.46 0.26 7.0 ft2 7 ft 8 in 1 ft 3 in Drapes/blinds None 4 E=>W 6 Metal Low-E Double Yes 0.49 0.24 30.0 ft2 2 ft 0 in 1 ft 6 in Drapes/blinds None 5 N=>S 7 Metal Low-E Double Yes 0.49 0.24 20.0 ft2 2 It 0 in 1 It 6 in Drapes/blinds None 6 W=>E 8 Metal Low-E Double Yes 0.49 0.24 20.0 ft2 15 ft 6 in 1 It 6 in Drapes/blinds None 7 N=>S 10 Metal Low-E Double Yes 0.5 0.25 72.0 ft2 12 ft 2 in 1 It 7 in Drapes/blinds None 8 N=>S 12 Metal Low-E Double Yes 0.49 0.24 36.0 ft2 2 It 0 in 1 ft 5 in Drapes/blinds None 9 W=>E 13 Metal. Low-E Double Yes 0.46 0.26 12.0 ft2 2 It 0 in 1 ft 6 in Drapes/blinds None 10 W=>E 13 Metal Low-E Double Yes 0.49 0.24 20.0 ft2 2 ft 0 in 1 ft 6 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wail Height Exposed Wall Insulation 1 534.8035 ft2 534.8035 ft2 69 It 9.33 ft 0 3/29/2017 4:10 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 L1 Wholehouse Proposed ACH(50) .000296 1519.2 83.4 156.85 .2223 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 36 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts ` 1 Central Unit Split SEER: 16 36 kBtu/hr 1080 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 394.2 ft Attic 98.55 ft Proposed Qn Main —cfm 117.2 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: N He Nov Dec ating Jan Feb f X�Mar �j Apr May J I IM r] u r ay n ri Jul rl Aug Sep La Oct Oct Nov Dec Venting Jan Feb [X Mar Jun Jul Aug Sep lxl 3/29/2017 4:10 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(VVEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM .78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 3/29/2017 4:10 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. 2694 Conifer Dr, Ft Pierce, FL, 34951 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1748.40 ft2 b. Frame-Steel,Adjacent R=11.0 227.11 ft2 J. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a. Under Attic(Vented) R=30.0 1954.00 ft2 '6. Conditioned floor area(ft2) 1954 b. N/A R= ft2 7. Windows** Description Area c. A R= ft2 a. U-Factor: Dbl,U=0.49 164.31 ft2 11.Ducts R ft2 a.Sup:Attic, Ret:Attic,AH:Main 6 394.2 SHGC: SHGC=0.24 b. U-Factor: Dbl,U=0.50 72.00 ft2 SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.46 19.00 ft2 a.Central Unit 36.0 SEER:16.00 SHGC: SHGC=0.26 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 36.0 COP:1.00 Area Weighted Average Overhang Depth: 5.962 ft. Area Weighted Average SHGC: 0.244 8. Floor Types Insulation Area 14.Hot water systems a. Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1954.00 ft2EF:0.95 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Tg>L sT Construction through the above y`ergy saving features which will be installed (or exceeded) -,oin this home before final inspecti Otherwise, a new EPL Display Card will be completed �wQ' `'''�i' r based on installed Code complia atures. o Builder Signature: A Date: j0 -;')� o �a Address of New Home: City/FL Zip: i c �- OD wr-1 .3`1�FS- *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/29/2017 4:20 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Building Analysis Job: Biscayne Grande Lot44 Date: 3-14-17 Entire House By: Skyetec Project Information For: GHO Homes 2694 Conifer Dr, Fort Pierce, FL 34951 Design Conditions Location: Indoor: Heating Cooling Vero Beach, FL, US Indoor temperature(°F) 70 75 Elevation: 26 ft Design TD (°F) 27 15 Latitude: 28°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 22.0 61.5 Dry bulb(°F) 43 90 Infiltration: Daily range�°F) - 16 ( L ) Method Simplified Wet bulb(°F - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heating Component Btuh/ft2 Btuh % of load Walls 3.8 6582 22.3 Glazing 13.2 3428 11.6 -� Doors 10.5 491 1.7 Ceilings 0.9 1689 5.7 Floors 3.1 6075 20.5 Infiltration 2.0 3554 12.0 Ducts 5739 19.4 Piping 0 0 Humidification 0 0 - Ventilation 2003 6.8 Adjustments 0 Total 29561 100.0 Cooling Component Btuh/ftz Btuh % of load Walls 2.4 4214 16.3 Glazing 14.8 3835 14.8 Doors 11.2 521 2.0 Ceilings 1.0 2011 7.8 Floors 0 0 0 Infiltration 0.6 1039 4.0 Ducts 7247 28.0 Ventilation 1113 4.3 Internal gains 5895 22.8 Blower 0 0 Adjustments 0 Total 25875 100.0 Latent Cooling Load= 9024 Btuh Overall U-value= 0.114 Btuh/ftz-°F Data entries checked. - wrightsoft" _ _ _ 2017-Mar-2815:42:59 RightSuite®Universal 2017 17.0.04 RS000268 Page 1 ...ulations\Skytec\Biscayne Grande Lot 44 GL N.rup Calc=MJ8 Front Door faces: N P . o LE c F I Component Constructions Job: Biscayne Grande Lot 44 Date: 3-14-17 Entire House By: Skyetec Project Information For: GHO Homes 2694 Conifer Dr, Fort Pierce, FL 34951 Qesign Conditions Location: Indoor: Heating Cooling 1 Vero Beach, FL, US Indoor temperature(T) 70 75 Elevation: 26 ft Design TD (T) 27 15 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr1lb) 22.0 61.5 Dry bulb(T) 43 90 Infiltration: Daily range(T) - 16 ( L ) Method Simplified Wet bulb( F) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/ft?°F ft?"F/Btuh BLOW Btu MOM Btuh Walls 13A-4ocs:Blk wall,stucco ext,r-4 ext bd ins,8"thk,1/2"gypsum n 148 0.143 4.0 3.86 572 2.50 370 board intfnsh a 492 0.143 4.0 3.86 1901 2.50 1229 se 40 0.143 .4.0 3.86 154 2.50 100 s 290 0.143 4.0 3.86 1121 2.50 724 w 557 0.143 4.0 3.86 2150 2.50 1390 all 1528 0.143 4.0 3.86 5898 2.50 3812 Partitions 126-0sm:Frm wall,stucco ext,r-11 cav ins,1/2"gypsum board int 208 0.122 11.0 3.29 684 1.93 402 fnsh,2"x4"metal frm,16"o.c.stud Windows 2 glazing,clr low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,1/4" n 8 0.460 0 12.4 99 9.93 79 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);50%blinds 45°,medium;50% outdoor insect screen;4 ft overhang(8 ft window ht,3 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,1/4" n 36 0.490 0 13.2 476 10.1 362 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45°,medium;50% outdoor insect screen;1.5 ft overhang(6 ft window ht,1 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,1/4" a 12 0.460 0 12.4 149 23.9 286 thk:2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);50%blinds 45°,medium;50% outdoor insect screen;1.5 ft overhang(2 ft window ht,1 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap,1/4" a 20 0.490 0 13.2 265 24.0 480 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, s 30 0.490 0 13.2 397 10.1 302 1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45°,medium;50% s 20 0.490 0 13.2 265 10.1 201 outdoor insect screen;1.5 ft overhang(5 ft window ht,1 ft sep.);6.67 ft head ht w 30 0.490 0 13.2 397 24.0 720 all 100 0.490 0 13.2 1323 17.0 1702 1 �{� htsoft®I'1 2017-Mar-28 15:43:00 W 1 9 Right-Suite®Universal 2017 17.0.04 RS000268 Page 1 ...ulations\Skytec\Biscayne Grande Lot 44 GL N.rup Calc=MJ8 Front Door faces: N 2 glazing,cir low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap,1/4" a 21 0.490 0 13.2 276 20.3 424 thk:2 glazing,clr low-e outr,argon gas,vni frm mat,clr innr, 1/4"gap, 1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45°,medium;50% outdoor insect screen;3 ft overhang(5 ft window ht,1 ft sep.);6.67 ft head ht 2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,1/4" s 72 0.500 0 13.5 972 10.3 744 ► thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);50%blinds 45°,medium;50% outdoor insect screen;12.5 ft overhang(8 ft window ht,1 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,1/4" w 10 0.490 0 13.2 132 23.8 238 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45°,medium;50% outdoor insect screen;4 ft overhang(5 ft window ht,3 ft sep.);6.67 ft head ht Doors 11 DO:Door,wd sc type n 24 0.390 0 10.5 253 11.2 268 n 23 0.390 0 10.5 239 11.2 253 all 47 0.390 0 10.5 491 11.2 521 a Ceilings 16D-30td:Attic ceiling,tile,slate,concrete roof mat,r-30 ceil ins,1/2" 1955 0.032 30.0 0.86 1689 1.03 2011 gypsum board intfnsh Floors 22A-cpm:Bg floor,heavy dry or light damp soil,on grade depth,carpet 92 1.180 0 31.9 2915 0 0 fir fnsh 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth,tile fir 99 1.180 0 31.9 3159 0 0 fnsh •: htsoft® 2017-Mar-2815:43:00 WCI 9 Right-Suite®Universal 2017 17.0.04 RS000268 Page 2 ...ulations%Skytec\Biscayne Grande Lot 44 GL N.rup Calc=MJ8 Front Door faces: N Project Summary Job: Biscayne Grande Lot44 Date: 3-14-17 Entire House By: Skyetec ;r Project Information For: GHO Homes 2694 Conifer Dr, Fort Pierce, FL 34951 Notes: r Design • • Weather: Vero Beach, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 27 °F Design TD 15 °F Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23822 Btuh Structure 18628 Btuh Ducts 5739 Btuh Ducts 7247 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 29561 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 24582 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 6753 Btuh Ducts 2270 Btuh Heating Coolingg� Central vent (0 cfm) 0 Btuh Area(ft2 1955 1955 Equipment latent load 9024 Btuh Volume(ft') 18912 18912 Air changes/hour 0.38 0.20 Equipment total load 33605 Btuh Equiv.AVF(cfm) 120 63 Req. total capacity at 0.80 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM; RUUD Model Cond RA1636AJ1 AHRI ref Coil RH1T3621MTAN AHRI ref 7942208 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 12.3 kW Sensible cooling 28800 Btuh Heating output 41975 Btuh Latent cooling 7200 Btuh Temperature rise 32 °F Total cooling 36000 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.041 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.74 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. C - - wrightsoft- 2017-Mar-2815:43:00 ACCp. Right-Suite®Universal 2017 17.0.04 RS000268 Page 1 ...ulations\Skytec\Biscayne Grande Lot 44 GL N.rup Calc=MJ8 Front Door faces: N N First Floor IGtchen q 12 x 12 Master BR 289 � Ey�10',18.7 f1 11.8 ft 6 x 6 CFM 1ox1U a•,zsn 1ox10 3 CFM T T 93 CFM 7°.8.9 ft Schedule 18 x 18 Her 10',6.5 ft O Exhaust Fan 99 CFM 6 x 6 8 x 8 OR Range Vent 15 CFM 4' 8 3 ft � Living i /6',2.9 ft \ 183 Dining 6,6 �W 1000 g D Dryer Vent 48 CFM d " B",7.3 ft Rheem Equipment 5',8.8 ft M Ba CF AHu 3.0 Ton 16 SEER RH1 T36 O 6x6 8",9.4ft 4•,4.7 ft - 12',12.4 ft _•-- • - 10 x 10 Cond 3.0 Ton 16 SEER RA1636 4•,7.0 ft y 88 CFM 4•,5.2 ft C2 6x68 4",10.7ft CFM 14•, ).Oft 7",4.1 ft Foyer 6 x 6 Den Id 1 CFM 99pp 148 Hal 120b1CFM BR 2 16z'10 F D 16•,3.5 ft- 16-,30.7ft r. 6",7.4 ft 8x8 12 x 12- tility 103 CFM 18 17.0 ft 10',6.3 ft 3.0 Ton Garage Job#: Biscayne Grande Lot 44 Scale: 1 : 133 Performed by Skyetec for: Page 1 GHO Homes Right-Suite®Universal 2017 2694 Conifer Dr 17.0.04 RSU00268 Fort Pierce,FL 34951 2017-Mar-28 15:43:03 ...\Biscayne Grande Lot 44 GL N.rup Duct System Summary Job: Biscayne Grande Lot44 Date: 3-14-17 ' Entire House By: Skyetec Project Information For: GHO Homes 2694 Conifer Dr, Fort Pierce, FL 34951 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.18 in H2O 0.18 in H2O Available static pressure 0.32 in H2O 0.32 in H2O Supply/return available pressure 0.231 /0.089 in H2O 0.231 /0.089 in H2O Lowest friction rate 0.108 in/100ft 0.108 in/100ft Actual air flow 1200 cfm 1200 cfm Total effective length (TEL) 296 ft • • Branch-Detail • Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln(ft) Ln (ft) Trunk BR 2 c 3192 123 148 0.181 7.0 Ox 0 VIFx 7.6 120.0 st2 Bath 2 c 84 3 4 0.177 4.0 Ox 0 VIFx 10.5 120.0 st2 Den h 3890 158 88 0.130 8.0 Ox 0 VIFx 37.4 140.0 SO Dining c 2135 79 99 0.139 6.0 Ox 0 VIFX 30.9 135.0 st1 Foyer h 997 40 31 0.133 4.0 Ox0 VIFx 38.7 135.0 st1 Hers c 58 2 3 0.116 4.0 Ox 0 VIFx 24.9 175.0 st4 His h 794 32 15 0.112 4.0 Ox 0 VIFx 30.8 175.0 st4 Kitchen c 6230 248 289 0.127 10.0 Ox O VIFx 46.7 135.0 st1 Living-B c 3949 132 183 0.134 8.0 Ox0 VIFX 23.3 150.0 st3 M Bath h 1466 59 48 0.132 5.0 Ox0 VIFx 24.7 150.0 st3 Master BR h 2967 120 93 0.108 7.0 OX 0 VIFx 34.3 180.0 st4 Master BR-A h 2967 120 93 0.110 7.0 OX 0 VIFX 31.3 180.0 st4 Utility c 2222 80 103 0.177 6.0 Ox0 VIFx 11.0 120.0 st2 Vic c 29 1 1 0.136 4.0 Ox0 VIFx 20.7 150.0 st3 WIC 2 c 49 2 2 0.180 4.0 Ox0 VIFx 8.7 120.0 st2 Supply • Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 275 203 0.108 504 10.0 0 x 0 VinlFlx st3 st1 Peak AVF 526 507 0.127 492 14.0 0 x 0 VinlFlx st3 Peak AVF 467 436 0.108 594 12.0 0 x 0 VinlFlx st2 st2 Peak AVF 674 693 0.108 496 16.0 0 x 0 VinlFlx Bold/italic values have been manually overridden wri htsoft' 2017-Mar-2815:43:00 9 Right-Suite®Universal 2017 17.0.04 RS000268 ...ulations\Skytec\Biscayne Grande Lot 44 GL N.rup Calc=MJ8 Front Door faces: N Page 1 I TableRetUrn Branch Detail • Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox0 1200 1200 82.0 0.108 679 18.0 Ox 0 VIFx it htsoft® 2017-Mar-28 15:43:00 —AL WCI 9 RightSuite®Universal 2017 17.0.04 RS000268 Page 2 ...ulations\Skytec\Biscayne Grande Lot 44 GL N.rup Calc=MJ8 Front Door faces: N I