Loading...
HomeMy WebLinkAboutProduct Approval (4) w 4/18/2017 Florida Building Code Online BCIS Home Log In User Registration Hot Topics I Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map I Links 'Search Florida �e• Product Approval a USER: Public User o:} i } Product Approval Menu>Product or Application Search>Application List>Application Detail -� FL# FL15349-R8 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived O Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 (717) 365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Fixed Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Steven M. Urich, PE L Validation Checklist- Hardcopy Received Referenced Standard and Year(of Standard) Standard Year AAMA 506 2008 AAMA/WDMA/CSA 101/I.S. 2/A440 2008 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 11/18/2016 Date Validated 11/18/2016 Date Pending FBC Approval Date Approved 12/01/2016 https://www.floridabuilding.orgtpr/pr_app dtl.aspx?param=wGEVXQwtDgtH8572gvdWlanDWDAgM3Z07v%2gz55PiLs%p2fQnO2HE8 A%3d' '� 1/3 Y 4/18/2017 Florida Building Code Online Summary of Products FL# Model,Number or Name Description 15349.1 185 PW 73 x 72 Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15349 R8 C CAC APC 12786.odf Approved for use outside HVHZ:Yes FL15349 R8 C CAC APC 12787.odf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +60/-60 04/03/2018 Other: CW-PG60 Installation Instructions FL15349 R8 II 08-02357B.odf Verified By: Luis R. Lomas, PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL15349 R8 AE 513124B.pdf Created by Independent Third Party: Yes ` 15340.2 185 PW 159 x 54 Triple CHS Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15349 R8 C CAC APC 15350.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 01/24/2021 Design Pressure: +55/-55 Installation Instructions Other: R-PG55 FL15349 R8 II 08-02949.odf Verified By: Luis R. Lomas, PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL15349 R8 AE 513783.odf Created by Independent Third Party: Yes 15349.3 185 PW Impact 72 x 72 Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15349 R8 C CAC APC 15454.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/25/2021 Design Pressure: +55/-55 Installation Instructions Other: FW-LC55, Missile Level D, Wind Zone 3. Glass FL15349 R8 II 08-02948.odf consisted of 5/32"tempered exterior-spacer-5/32" Verified By: Luis R. Lomas, PE 62514 annealed/0.100 Solutia Saflex HP/5/32" annealed. Glass Created by Independent Third Party: Yes was bedded in Pecora 896 silicone with 5/8" glass bite. Evaluation Reports FL15349 R8 AE 513782.odf Created by Independent Third Party: Yes 15349.4 185 PW Impact 159 x 54 Triple CHS Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15349 R8 C CAC APC 8272.odf Approved for use outside HVHZ:Yes FL15349 R8 C CAC APC 8273.odf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +55/-55 01/24/2021 Other: FW-R55, Missile Level D, Wind Zone 3. Glass Installation Instructions consisted of 1/8" annealed exterior-spacer-3/32"annealed FL15349 R8 II 08-01614B.pdf /0.090 Solutia PVB/3/32" annealed. Glass was bedded in Verified By: Luis Roberto Lomas 62514 Pecora 896 silicone with 5/8"glass bite. Created by Independent Third Party: Yes Evaluation Reports FLIS349 R8 AE 512278B.Ddf Created by Independent Third Party: Yes 15349.5 185 PW Impact 96 x 60 Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15349 R8 C CAC APC 7962.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/05/2020 Design Pressure: +55/-55 Installation Instructions Other: FW-LC55, Missile Level D, Wind Zone 3. Glass FL15349 R8 II 08-01613B.pdf consisted of 5/32"annealed exterior-spacer-5/32" Verified By: Luis Roberto Lomas 62514 annealed/0.100 Solutia Saflex HP/5/32" annealed. Glass Created by Independent Third Party: Yes was bedded in Pecora 896 silicone with 5/8"glass bite. Evaluation Reports FL15349 R8 AE 512277B.odf Created by Independent Third Party: Yes 15349.6 185 PW Impact 73 x 61 Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15349 R8 C CAC APC 12136.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 10/28/2017 Design Pressure: +55/-55 Installation Instructions https://www.floridabuilding.orgtpr/pr app_dtl.aspx?param=wGEVXQwtDgtH8572gvdWianDWDAgM3ZO7v%2oz55PiLs°/"2fQnO2HE8xPA%3d%3d 2/3 1 / 4/18/2017 Florida Building Code Online Other: FW-LC55, Missile Level D, Wind Zone 3. Glass FL15349 R8 II 08-02947.odf consisted of 1/8" annealed exterior-spacer- 1/8"annealed/ Verified By: Luis Roberto Lomas 62514 0.090 PVB/ 1/8"annealed. Glass was bedded in Pecora 896 Created by Independent Third Party: Yes silicone with 5/8"glass bite. Evaluation Reports FL15349 R8 AE 513781.1)df Created by Independent Third Party: Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: 09 Credit Card Safe https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtH8572gvdWianDWDAgM3ZO7v%2gz55P!Ls`/`2fQnO2HE8xPA%3dp/`3d 3/3 Models 9100-5120 ASCE 7-05 ASCE 7-10 Maximum Size Approvals 3-Second Gust Basic Wind Speeds(MPH)° 3-Second Gust Basic Wind Speeds(MPH)5 Positive Negative Exposure B Exposure C Exposure C Exposure B Exposure C Exposure C Exposure D Exposure D Design Design Revision t� _ Mean Roof Mean Roof Mean Roof Mean Roof Mean Roof Mean Roaf Mean Roof Mean Roof Option Code PSF PSF Width Height # m Glazing availablee Source Plant Height 5 30' Height 515' Height 5 25' Height 5 30' Height 515' Height 5 25' Height 515' Height<_25' Max 21"Section Height 0228e 26.90 30.80 9'-0" 8'-9" P7 FL 9174 GDR-34 Standard SPILP,Impact SP/LP Mt.Hoe 130 115 110 165 150 145 135 130 0234� 43.20 49.60 9'-0" 8'-9" PS FL 9174 GDR-34 Standard SP,Impact SP/LP Mt.Hoe 165 150 140 215 190 180 175 165 0229 15.30 17.00 16'-0" 8'-9" P8 FL 9174 N/A Standard SPILP Mt.Hoe 100 90 85 125 115 110 105 100 02302 25.90 28.80 16'-0" 8'-9" P10 FL 9174 GDR-34 Standard SP/LP,Impact SP/LP Mt.Hoe 130 115 110 165 150 145 135 130 0231e 30.00 33.50 16'-0" 8'-9" P5 FL 9174 GDR-34 No Mt.Hoe 140 125 120 180 160 155 146 140. 0235 Poste 39.20 43.70 16'-0" 8'-0" P6 FL 9174 GDR-34 Standard SP,Impact SP/LP Mt.Hoe 160 146 135 205 185 175 170 160 0232 12.40 13.80 18'-0" 8'-9" P5 FL 9174 N/A Standard SP/LP Mt.Hoe 90 80 75 115 105 100 95 90 0233 18.50 20.70 18'-0" 8'-9" P5 FL 9174 GDR-34 Standard SP Mt.Hoe 110 100 95 140 125 120 115 110 0236 Poste 30.00 33.50 18'-0" 8'-0" P6 FL 9174 GDR-34 Standard SP,Im act SPILP Mt.Hoe 140 125 120 180 160 155 146 140 0237 Poste 39.20 43.70 18'-0" 8'-0" P6 I FL 9174 1 GDR-341 Standard SP,Impact SP/LP Mt.Hoe 160 146 135 205 185 175 170 160 Max 24"Section Height 0600 26.90 30.80 9'-0" 9'-0" P4 FL 9174 GDR-34 Standard SP/LP Mt.Hoe 130 115 110 165 150 145 135 130 0601 41.00 46.30 9'-0" 9'-0" P4 FL 9174 GDR-34 Impact SP/LP Mt.Hoe 160 146 135 205 185 175 170 160 0602 15.30 17.00 16'-0" 9'-0" P5 FL 9174 N/A Standard SP/LP Mt.Hoe 100 90 85 125 115 110 105 100 0603 23.00 25.00 16'4' 9'-0" P5 FL 9174 GDR-34 Standard SP Mt.Hoe 120 110 105 155 140 135 125 120 0604 Pos 39.20 43.70 16'4' 8'-0" P5 FL 9174 GDR-34 Impact SP/LP Mt.Hoe 160 146 135 205 185 175 170 160 0605 15.30 17.00 18'-0" 9'-0" P4 FL 9174 N/A Standard SPILP Mt.Hoe 100 90 85 125 115 110 105 100 0606 Post 30.00 33.50 18'-0" 8'-0" P6 FL 9174 GDR-34 Standard SP/LP Mt.Hoe 140 125 120 180 160 155 146 140 0609 Poste 39.20 43.70 18'-0" 8'-0" P5 FL 9174 GDR-34 No Mt.Hoe 160 146 135 205 185 175 170 160 0356 15.90 18.20 9'-0" 12'-0" P3 NIA N/A Standard SP/LP Mt.Hoe 100 90 85 130 115 110 105 100 Post Installation Instructions Jamb Connection Suoolement Track Suoolement Chart 1. Al doors tested for uniform static air pressure per ANSI/DASMA 108 to test pressure of 1.5 x design pressure 2. Also tested for large missile impact and cyclic wind pressure per ANSI/DASMA 115 3. FBC-Florida Building Commission,TDI-Texas Department of Insurance 4. Above wind speeds based on ASCE 7 are applicable for enclosed structures with an importance factor of 1.0 and assume a maximum of 2'of the door is located within the end zone of a structure. Consult a registered Architect or Structural Engineer for applicability for other project specific conditions. 5. Above wind speeds based on ASCE 10 Category II structure with a maximum of 2'of the door is located within the end zone of a structure. Consult a registered Architect or Structural Engineer for applicability for other project specific conditions. 6.Standard SP/LP-Short(Single Colonial,Single Sonoma)and long(Double Sonoma,Ranch)panel glazing is not impact resistant and does not meet the requirements for Wind-Borne Debris Regions. Standard SP-Short(Single Colonial,Single Sonoma)panel glazing is not impact resistant and does not meet the requirements for Wind-Borne Debris Regions. Impact SP/LP-Short(Single Colonial,Single Sonoma)and long(Double Sonoma,Ranch)is impact resistant and does meet the requirements for Wind-Rome Debris Regions. 7. Doors only available in greater than 7'heights. 8. Low Head Room track is available. 9. Al panel stiles available. Models 5120-9100 Page 1 of 1 4 . Latest Revision 07.17.2015