HomeMy WebLinkAboutProduct Approval (4) w
4/18/2017 Florida Building Code Online
BCIS Home Log In User Registration Hot Topics I Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map I Links 'Search
Florida �e•
Product Approval
a USER: Public User
o:} i }
Product Approval Menu>Product or Application Search>Application List>Application Detail
-� FL# FL15349-R8
Application Type Revision
Code Version 2014
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived O
Product Manufacturer MI Windows and Doors
Address/Phone/Email 650 West Market Street
Gratz, PA 17030
(717) 365-3300 Ext 2560
bsitlinger@miwd.com
Authorized Signature Brent Sitlinger
bsitlinger@miwd.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Fixed
Compliance Method Certification Mark or Listing
Certification Agency American Architectural Manufacturers Association
Validated By Steven M. Urich, PE
L Validation Checklist- Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
AAMA 506 2008
AAMA/WDMA/CSA 101/I.S. 2/A440 2008
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
Date Submitted 11/18/2016
Date Validated 11/18/2016
Date Pending FBC Approval
Date Approved 12/01/2016
https://www.floridabuilding.orgtpr/pr_app dtl.aspx?param=wGEVXQwtDgtH8572gvdWlanDWDAgM3Z07v%2gz55PiLs%p2fQnO2HE8 A%3d' '� 1/3
Y
4/18/2017 Florida Building Code Online
Summary of Products
FL# Model,Number or Name Description
15349.1 185 PW 73 x 72 Insulated Glass
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15349 R8 C CAC APC 12786.odf
Approved for use outside HVHZ:Yes FL15349 R8 C CAC APC 12787.odf
Impact Resistant: No Quality Assurance Contract Expiration Date
Design Pressure: +60/-60 04/03/2018
Other: CW-PG60 Installation Instructions
FL15349 R8 II 08-02357B.odf
Verified By: Luis R. Lomas, PE 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL15349 R8 AE 513124B.pdf
Created by Independent Third Party: Yes
` 15340.2 185 PW 159 x 54 Triple CHS Insulated Glass
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15349 R8 C CAC APC 15350.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 01/24/2021
Design Pressure: +55/-55 Installation Instructions
Other: R-PG55 FL15349 R8 II 08-02949.odf
Verified By: Luis R. Lomas, PE 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL15349 R8 AE 513783.odf
Created by Independent Third Party: Yes
15349.3 185 PW Impact 72 x 72 Insulated Laminated Glass
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15349 R8 C CAC APC 15454.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 06/25/2021
Design Pressure: +55/-55 Installation Instructions
Other: FW-LC55, Missile Level D, Wind Zone 3. Glass FL15349 R8 II 08-02948.odf
consisted of 5/32"tempered exterior-spacer-5/32" Verified By: Luis R. Lomas, PE 62514
annealed/0.100 Solutia Saflex HP/5/32" annealed. Glass Created by Independent Third Party: Yes
was bedded in Pecora 896 silicone with 5/8" glass bite. Evaluation Reports
FL15349 R8 AE 513782.odf
Created by Independent Third Party: Yes
15349.4 185 PW Impact 159 x 54 Triple CHS Insulated Laminated Glass
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15349 R8 C CAC APC 8272.odf
Approved for use outside HVHZ:Yes FL15349 R8 C CAC APC 8273.odf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure: +55/-55 01/24/2021
Other: FW-R55, Missile Level D, Wind Zone 3. Glass Installation Instructions
consisted of 1/8" annealed exterior-spacer-3/32"annealed FL15349 R8 II 08-01614B.pdf
/0.090 Solutia PVB/3/32" annealed. Glass was bedded in Verified By: Luis Roberto Lomas 62514
Pecora 896 silicone with 5/8"glass bite. Created by Independent Third Party: Yes
Evaluation Reports
FLIS349 R8 AE 512278B.Ddf
Created by Independent Third Party: Yes
15349.5 185 PW Impact 96 x 60 Insulated Laminated Glass
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15349 R8 C CAC APC 7962.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/05/2020
Design Pressure: +55/-55 Installation Instructions
Other: FW-LC55, Missile Level D, Wind Zone 3. Glass FL15349 R8 II 08-01613B.pdf
consisted of 5/32"annealed exterior-spacer-5/32" Verified By: Luis Roberto Lomas 62514
annealed/0.100 Solutia Saflex HP/5/32" annealed. Glass Created by Independent Third Party: Yes
was bedded in Pecora 896 silicone with 5/8"glass bite. Evaluation Reports
FL15349 R8 AE 512277B.odf
Created by Independent Third Party: Yes
15349.6 185 PW Impact 73 x 61 Insulated Laminated Glass
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15349 R8 C CAC APC 12136.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 10/28/2017
Design Pressure: +55/-55 Installation Instructions
https://www.floridabuilding.orgtpr/pr app_dtl.aspx?param=wGEVXQwtDgtH8572gvdWianDWDAgM3ZO7v%2oz55PiLs°/"2fQnO2HE8xPA%3d%3d 2/3
1 /
4/18/2017 Florida Building Code Online
Other: FW-LC55, Missile Level D, Wind Zone 3. Glass FL15349 R8 II 08-02947.odf
consisted of 1/8" annealed exterior-spacer- 1/8"annealed/ Verified By: Luis Roberto Lomas 62514
0.090 PVB/ 1/8"annealed. Glass was bedded in Pecora 896 Created by Independent Third Party: Yes
silicone with 5/8"glass bite. Evaluation Reports
FL15349 R8 AE 513781.1)df
Created by Independent Third Party: Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:
09
Credit Card
Safe
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtH8572gvdWianDWDAgM3ZO7v%2gz55P!Ls`/`2fQnO2HE8xPA%3dp/`3d 3/3
Models 9100-5120
ASCE 7-05 ASCE 7-10
Maximum Size Approvals 3-Second Gust Basic Wind Speeds(MPH)° 3-Second Gust Basic Wind Speeds(MPH)5
Positive Negative Exposure B Exposure C Exposure C Exposure B Exposure C Exposure C Exposure D Exposure D
Design Design Revision t� _ Mean Roof Mean Roof
Mean Roof Mean Roof Mean Roof Mean Roaf Mean Roof Mean Roof
Option Code PSF PSF Width Height # m Glazing availablee Source Plant Height 5 30' Height 515' Height 5 25' Height 5 30' Height 515' Height 5 25' Height 515' Height<_25'
Max 21"Section Height
0228e 26.90 30.80 9'-0" 8'-9" P7 FL 9174 GDR-34 Standard SPILP,Impact SP/LP Mt.Hoe 130 115 110 165 150 145 135 130
0234� 43.20 49.60 9'-0" 8'-9" PS FL 9174 GDR-34 Standard SP,Impact SP/LP Mt.Hoe 165 150 140 215 190 180 175 165
0229 15.30 17.00 16'-0" 8'-9" P8 FL 9174 N/A Standard SPILP Mt.Hoe 100 90 85 125 115 110 105 100
02302 25.90 28.80 16'-0" 8'-9" P10 FL 9174 GDR-34 Standard SP/LP,Impact SP/LP Mt.Hoe 130 115 110 165 150 145 135 130
0231e 30.00 33.50 16'-0" 8'-9" P5 FL 9174 GDR-34 No Mt.Hoe 140 125 120 180 160 155 146 140.
0235 Poste 39.20 43.70 16'-0" 8'-0" P6 FL 9174 GDR-34 Standard SP,Impact SP/LP Mt.Hoe 160 146 135 205 185 175 170 160
0232 12.40 13.80 18'-0" 8'-9" P5 FL 9174 N/A Standard SP/LP Mt.Hoe 90 80 75 115 105 100 95 90
0233 18.50 20.70 18'-0" 8'-9" P5 FL 9174 GDR-34 Standard SP Mt.Hoe 110 100 95 140 125 120 115 110
0236 Poste 30.00 33.50 18'-0" 8'-0" P6 FL 9174 GDR-34 Standard SP,Im act SPILP Mt.Hoe 140 125 120 180 160 155 146 140
0237 Poste 39.20 43.70 18'-0" 8'-0" P6 I FL 9174 1 GDR-341 Standard SP,Impact SP/LP Mt.Hoe 160 146 135 205 185 175 170 160
Max 24"Section Height
0600 26.90 30.80 9'-0" 9'-0" P4 FL 9174 GDR-34 Standard SP/LP Mt.Hoe 130 115 110 165 150 145 135 130
0601 41.00 46.30 9'-0" 9'-0" P4 FL 9174 GDR-34 Impact SP/LP Mt.Hoe 160 146 135 205 185 175 170 160
0602 15.30 17.00 16'-0" 9'-0" P5 FL 9174 N/A Standard SP/LP Mt.Hoe 100 90 85 125 115 110 105 100
0603 23.00 25.00 16'4' 9'-0" P5 FL 9174 GDR-34 Standard SP Mt.Hoe 120 110 105 155 140 135 125 120
0604 Pos 39.20 43.70 16'4' 8'-0" P5 FL 9174 GDR-34 Impact SP/LP Mt.Hoe 160 146 135 205 185 175 170 160
0605 15.30 17.00 18'-0" 9'-0" P4 FL 9174 N/A Standard SPILP Mt.Hoe 100 90 85 125 115 110 105 100
0606 Post 30.00 33.50 18'-0" 8'-0" P6 FL 9174 GDR-34 Standard SP/LP Mt.Hoe 140 125 120 180 160 155 146 140
0609 Poste 39.20 43.70 18'-0" 8'-0" P5 FL 9174 GDR-34 No Mt.Hoe 160 146 135 205 185 175 170 160
0356 15.90 18.20 9'-0" 12'-0" P3 NIA N/A Standard SP/LP Mt.Hoe 100 90 85 130 115 110 105 100
Post Installation Instructions
Jamb Connection Suoolement
Track Suoolement Chart
1. Al doors tested for uniform static air pressure per ANSI/DASMA 108 to test pressure of 1.5 x design pressure
2. Also tested for large missile impact and cyclic wind pressure per ANSI/DASMA 115
3. FBC-Florida Building Commission,TDI-Texas Department of Insurance
4. Above wind speeds based on ASCE 7 are applicable for enclosed structures with an importance factor of 1.0 and assume a maximum of 2'of the door is located within the end zone of a structure. Consult a registered Architect or
Structural Engineer for applicability for other project specific conditions.
5. Above wind speeds based on ASCE 10 Category II structure with a maximum of 2'of the door is located within the end zone of a structure. Consult a registered Architect or Structural Engineer for applicability for other project specific
conditions.
6.Standard SP/LP-Short(Single Colonial,Single Sonoma)and long(Double Sonoma,Ranch)panel glazing is not impact resistant and does not meet the requirements for Wind-Borne Debris Regions.
Standard SP-Short(Single Colonial,Single Sonoma)panel glazing is not impact resistant and does not meet the requirements for Wind-Borne Debris Regions.
Impact SP/LP-Short(Single Colonial,Single Sonoma)and long(Double Sonoma,Ranch)is impact resistant and does meet the requirements for Wind-Rome Debris Regions.
7. Doors only available in greater than 7'heights.
8. Low Head Room track is available.
9. Al panel stiles available.
Models 5120-9100
Page 1 of 1
4 . Latest Revision 07.17.2015