HomeMy WebLinkAboutProduct Approval (8) 4/1W2017 Florida Building Code Online
�tt� .n¢re.ws. rr
0 0
BCIS Home Log In I User Registration Hot Topics I Submit Surcharge I Stats&Facts I Publications FBC Staff BCIS Site Map I Links I •Search
b
a r
Product Approval USER:Public User
u'ub'(n F�.4m L Pa'T:'>Tb
Product Approval Menu>Product or Application Search>Application List>Application History>Application Detail
FL# FL7630-RS
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived L!
Product Manufacturer Therma-Tru Corporation
Address/Phone/Email 118 Industrial Drive
Edgerton, OH 43517
(419) 298-1740
rickw@rwbldgconsultants.com
Authorized Signature Rick Wright
rickw@rwbldgconsultants.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
L✓ Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E.
the Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2018
Validated By Ryan J. King, P.E.
L'' Validation Checklist-Hardcopy Received
Certificate of Independence FL7630 R5 COI Certificate Of Indeoendence.pdf
Referenced Standard and Year(of Standard) Standard Year
AAMA/W DMA/101/I.S.2/A440-05 2005
ASTM E1886 2002
ASTM E1996 2002
ASTM E330 2002
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgsrGsgvbZHHs30VFES3QxSGPO17EfDkJdzZKQHXaN 6 H4JnDpxTVm IJ�. /4
s
4/18f2017 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 01/31/2015
a Date Validated 02/02/2015
Date Pending FBC Approval 02/06/2015
Date Approved 04/15/2015
Date Revised 06/13/2015
Summary of Products
FL# Model,Number or Name Description
7630.1 a. "FiberClassic", "SmoothStar", 8'0"Impact"Glazed Fiberglass Single Door-Inswing or
"ClassicCraft"and"ClassicCraft Outswing configuration (X)
Rustic"
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7630 R5 II Inst 7630.1.Ddf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 7630.1 for Design Pressure Ratings, any FL7630 RS AE EVAL 7630.1.odf
additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
7630.2 b. "FiberClassic", "SmoothStar", 8'0"Impact"Glazed Fiberglass Single Door with sidelite-
"ClassicCraft" and"ClassicCraft Inswing or Outswing configuration (OX or XO)
Rustic"
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7630 R5 II Inst 7630.2.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 7630.2 for Design Pressure Ratings, any FL7630 R5 AE EVAL 7630.2.odf
additional use limitations, installation instructions and Created by Independent Third Party:Yes
product particulars.
7630.3 c. "FiberClassic", "SmoothStar", 8'0"Impact" Glazed Fiberglass Single Door with sidelites-
"ClassicCraft"and "ClassicCraft Inswing or Outswing configuration (OXO)
Rustic"
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7630 R5 II Inst 7630.3.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 7630.3 for Design Pressure Ratings, any FL7630 R5 AE EVAL 7630.3.odf
additional use limitations, installation Instructions and Created by Independent Third Party: Yes
product particulars.
7630.4 d. "FiberClassic", "SmoothStar", 8'0"Impact"Glazed Fiberglass Double Door-Inswing or
"ClassicCraft"and "ClassicCraft Outswing configuration(XX)
Rustic"
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7630 R5 II Inst 7630.4.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 7630.4 for Design Pressure Ratings, any FL7630 R5 AE EVAL 7630.4.0f
additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
7630.5 e. "FiberClassic", "SmoothStar", 8'0"Impact"Glazed Fiberglass Double Door with sidelites-
"ClassicCraft"and "ClassicCraft Inswing or Outswing configuration (OXXO)
Rustic"
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7630 R5 II Inst 7630.5.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 7630.5 for Design Pressure Ratings, any FL7630 R5 AE EVAL 7630.5.1)df
additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
7630.6 f. "FberClassic", "SmoothStar", 8'0"Impact" Glazed Fiberglass Single Door utilizing Hoppe
"ClassicCraft"or"ClassicCraft Multi Point lock-Inswing or Outswing configuration (X)
https://www.floridabuilding.org/pr/pr app dti.aspx?param=wGEVXQwtDgsrGsgvbZHHs3OVFES3QxSGPO17EfDkJdzZKQHXaNA°/"2fPvH4JnDpxTVmcZfiJl... 214
I '
4/13/2017 Florida Building Code Online
Rustic"
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7630 R5 II Inst 7630.6.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt, P.E. 43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 7630.6 for Design Pressure Ratings, any FL7630 R5 AE EVAL 7630.6.adf
additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
7630.7 g. "FiberClassic", "SmoothStar", 8'0"Impact"Glazed Fiberglass Single Door with sidelite
"ClassicCraft"or"ClassicCraft utilizing Hoppe Multi Point lock-Inswing or Outswing
Rustic" configuration (OX or XO)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7630 R5 II Inst 7630.7.Ddf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant:Yes Created by Independent Third Party: Yes
" Design Pressure: N/A Evaluation Reports
Other:See INST 7630.7 for Design Pressure Ratings, any FL7630 R5 AE EVAL 7630.7.Ddf
additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
7630.8 h. "FiberClassic", "SmoothStar", 8'0"Impact"Glazed Fiberglass Single Door with sidelites
"ClassicCraft"or"ClassicCraft utilizing Hoppe Multi Point lock-Inswing or Outswing
Rustic" configuration (OXO)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7630 R5 II Inst 7630.8.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 7630.8 for Design Pressure Ratings, any FL7630 R5 AE EVAL 7630.8,pdf
additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
7630.9 i. "FiberClassic", "SmoothStar", 8'0 "Impact"Glazed Fiberglass Double Door utilizing Hoppe
"ClassicCraft"or"ClassicCraft Multi Point lock-Inswing or Outswing configuration (XX)
Rustic"
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7630 R5 II Inst 7630.9.Ddf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt, P.E. 43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 7630.9 for Design Pressure Ratings, any FL7630 R5 AE EVAL 7630.9.odf
additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
7630.10 j. "FiberClassic", "SmoothStar", 8'0"Impact"Glazed Fiberglass Double Door with sidelites
"ClassicCraft"or"ClassicCraft utilizing Hoppe Multi Point lock-Inswing or Outswing
Rustic" configuration (OXXO)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL7630 R5 II INST 7630.10.Ddf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 7630.10 for Design Pressure Ratings, any FL7630 R5 AE EVAL 7630.10.odf
additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. ::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app dtI.aspx?param=wGEVXQwtDgsrGs9vbZHHs3OVFES3QxSGPO17EfDkJdzZKQHXaNA%2fPvH4JnDpxTVmcZflJl... 3/4
♦♦♦ ��i
OVERALL
76.2X. �..
5"MA
FRAME WIDTH
THERMA11TRU
37.75"MAX.36.0 L WIDT FRAME WIDTH
AX
PANEL WIDTH SIDELITE
THERMA TPU D ® ® 1.S ( J
1 1 E3 INDUSTRIAL DR., EbGCRTON, OH 4351 7 �i� ................ 5♦� >°
��II♦
ZO
U N•�
"SMOOTH STAR", "FIRER CLASSIC". ��� � �rq z
"CLASSIC CRAFT" & "CLASSIC CRAFT RUSTIC" o 1`o �
E oZ
GLAZED FIBERGLASS SINGLE DOOR w/SIDELITE
INSWING/ OLITSWING
o
0
"IMPACT"
GENERAL NOTES
N
1, This product has been evaluated and is In compliance with the Sth Edition(2014J Florida Building N _
Code(FBCJ structural requirements excluding the'Vigh Velocity Hurricane Zone"(HVHZ), b y GI o w
o a O ¢ R
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base a a a
y material shall be beyond wall dressing or stucco.
16 3. When used in areas requiring wind borne debris protection this product complies with Section
1 1609.1.2 of the FBC and does not require an Impact resistant covering.This product meets missile �/ W
level"D"and Includes Wind Zone 4 as defined in ASTM E 1996 and Section 1609.1.2.2 of the FBC.
kk 4. Pot 2x stud framing construction,anchoring of these units shall be the some as that shown for 2x
buck masonry construction. o 0
U)
5. Site conditions that deviate from the details of this drawing require further engineering analysts by a
O TENCd
licensed engineer or registered architect,
d —��---0.75" W k k'
TABLE OF CONTENTS c o 0
SHEET# DESCRIPTION "SMOOTH STAR","FIBER CLASSIC"
1 Typical elevations,design pressures&general notes "CLASSIC CRAFT"&"CLASSIC CRAFT RUSTIC" ==^ P
2 Smooth Star door/sidelife panel&glazing details =
3 Fiber Classic door/sidelife panel&glazing details
4 Classic Craft/Classic Craft Rustic door/sidelife panel&glazing details OVERALL OVERALL . DESIGN PRESSURE(PSF) o
5 Horizontal cross sections SWING FRAME D.L.O.DOOR/SIDELlTE N z u
6 Vertical crosssections DIMENSION DIMENSION POSITIVE NEGATIVE DATE: 5120108 i
7 Verficol cross sections stAF. N.T.S.
8 Buck anchoring-2Xbuckmasonryconstruction INSWING 76.25"x98.00" 21.00"x78.75" +50.0 -50.0 M.Dr: AL m"
F _
9 Frame anchoring•IX buck masonry construction OU CM Dn LFS y
TSWING 76
10 Components .25"x 46.75" 21.00"x 78.75" +50.0 -50.0 d
p ORA'KIKC NO:
n II 8111ofMatedals FL-7630.2 0
SHEET OF
FJ,
C
1