HomeMy WebLinkAboutNotice of Acceptance (3) M IAM MIAMI-DADE COUNTY
-- PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Eagle Roofing Products LLC
1575 East C.R. 470
Sumterville,FL 33585
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revolve this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Bel Air,Bel Air Double Eagle,Ponderosa,Ponderosa Double Eagle,Golden Eagle
Low Profile Concrete Tiles
LABELING: Each unit shall bear a g permanent label with the manufacturer's name or to i o, city,tY, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No.15-0223.18 and consists of pages 1 through 9. FILE
The submitted documentation was reviewed by Gaspar J Rodriguez. COPY
n`
NOA No.:16-0314.06
eiiecnui�r Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 1 of 9
r
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: Roofing Tiles
Material: Concrete
1. SCOPE:
This approves a new roofing system using "Low Profile Concrete Tile" as manufactured by Eagle Roofing
Products LLC in Sumterville, FL and described in Section 2 of this Notice of Acceptance. For use in
locations where the pressure requirements, as determined by applicable Building Code, do not exceed the
design pressure values obtained by calculations in compliance with RAS 127 using the values listed in
section 4 herein. The attachment calculations shall be done as a moment based system.
2.PRODUCT DESCRIPTION:
Manufactured by Test Product
Applicant Dimensions Specifications Description
Bel Air Lenght= 17" TAS 112 Flat profile concrete roof tile equipped with two
Concrete Tile Width= 12 '/a" Type 3a nail holes. For adhesive set, direct deck or
Thickness= %2" Class III battened nail-on applications.
Bel Air Double Eagle Lenght= 17" TAS 112 Flat profile concrete roof tile equipped with two
Concrete Tile Width= 12 1/4" Type 3a nail holes. For adhesive set, direct deck or
Thickness= '/z" Class III battened nail-on applications.
Ponderosa Lenght= 17" TAS 112 Flat profile concrete roof tile with slate finish
Concrete Tile Width= 12 1/4" Type 3a equipped with two nail holes. For adhesive set,
Thickness= '/z" Class III direct deck or battened nail-on applications.
Ponderosa Double Eagle Lenght= 17" TAS 112 Flat profile concrete roof tile with shake finish
Concrete Tile Width= 12 1/4" Type 3a equipped with two nail holes. For adhesive set,
Thickness= 1/z" Class III direct deck or battened nail-on applications.
Golden Eagle Lenght= 17" TAS 112 Flat profile concrete roof tile brushed finish
Concrete Tile Width= 12 1/4" Type 3a equipped with two nail holes. For adhesive set,
Thickness= 1/Z" Class III direct deck or battened nail-on applications.
Trim Pieces Lenght=varies TAS 112 Accessory trim, clay roof pieces for use at hips,
Width=varies rakes, ridges and valley terminations.
varying thickness Manufactured for each tile profile.
NOA No.:16-0314.06
riaecaurr Expiration Date: 10/05/21
•• :� aal
Approval Date: 06/16/16
Page 2 of 9
2.1 EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
PRI Asphalt Technologies ERPF-001-02-01 TAS 112 Aug. 2006
Redland Technologies 7161-03 Static Uplift Testing Dec. 1991
Appendix III TAS 102
Redland Technologies 7161-03 Static Uplift Testing Dec. 1991
Appendix III TAS 102(A)
Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991
Appendix II TAS 108 (Nail-On)
Redland Technologies P0402 Withdrawal Resistance Testing of screw vs. Sept. 1993
` smooth shank nails
Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994
1994 TAS 108 (Nail-On)
Redland Technologies P09647-01 Wind Tunnel Testing Aug. 1994
TAS 108 (Mortar Set)
The Center for Applied 94-084 Static Uplift Testing May 1994
Engineering,Inc. TAS 101 (Mortar Set)
The Center for Applied 25-7094-(2, 5, & 8) Static Uplift Testing Oct. 1994
Engineering,Inc. TAS 102
The Center for Applied 25-7183-(5 thru 6) Static Uplift Testing Feb. 1995
Engineering,Inc. TAS 102 .
The Center for Applied 25-7214-(1, 5 , & 8) Static Uplift Testing March, 1995
Engineering,Inc. TAS 102
The Center for Applied 25-7487-2 Static Uplift Testing
pp p sting Dec. 1995
Engineering,Inc. TAS 102
The Center for Applied 25-7496-(l &4) Static Uplift Testing Dec. 1995
Engineering,Inc. TAS 102
The Center for Applied 25-7804-6 Static Uplift Testing Sep. 1996
Engineering,Inc. TAS 102
Celotex Corporation Testing 520109-1 Static Uplift Testing Dec. 1998
Service 520111-4 TAS 101
Celotex Corporation Testing 520191-1 Static Uplift Testing March 1999
Service TAS 101
Walker Engineering,Inc. Calculations Aerodynamic Multiplier Sep. 2006
Walker Engineering,Inc. Calculations Restoring Moments Due to Gravity Sep. 2006
ATL of South Florida RT1214.01-15 TAS-112 12/17/15
--------___ _. __ NOA No.:16-0314.06
r¢i„c+suae ,❑ Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 3 of 9
3 LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 shall be
required,refer to applicable Building Code.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami-Dade County Product
Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable Building Code.
4 INSTALLATION:
4.1 Eagle Roofing Products LLC Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle
Flat Concrete Roof Tiles and its components shall be installed in strict compliance with Roofing Application
Standard RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile Weight-W(Ibf) Length-I (ft) Width-w (ft)
Bel Air, Bel Air Double Eagle, Ponderosa, Golden 11.4 1.42 1.03
,Eagle, Ponderosa Double Eagle Flat Tile
Table 2: Aerodynamic Multipliers - (ft3)
Tile Profile A (ft3) A (ft3)
Batten Application Direct Deck Application
Bel Air, Bel Air Double Eagle, Ponderosa, Golden 0.301 0.278
Eagle, Ponderosa Double Eagle Flat Tile
Table 3: Restoring Moments due to Gravity - M9 (ft-Ibf)
Tile 3":12" 4":12" 5":12" 6":12" Greater than
Profile 7":12"
Bel Air, Bel Air Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct
Double Eagle, Deck Deck Deck Deck Deck
Ponderosa, 7.48 7.71 7.37 7.59 7.22 7.44 7.05 7.27 6.86 7.07
Golden Eagle,
Ponderosa
Double Eagle Flat
Tile
NOA No.:16-0314.06
raniaeO� Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 4 of 9
Table 4: Attachment Resistance Expressed as a Moment- Mf(ft-Ibf)
for Nail-On Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (min 15/32" plywood) (min. 19/32" plywood)
Bel Air, Bel 2-10d Ring Shank Nails 30.9 38.1 17.2
Air Double 1-10d Smooth or Screw 7.3 9.8 4.9
Eagle, Shank Nail
Ponderosa, 2-10d Smooth or Screw 14.0 18.8 7.4
Golden Shank Nails
Eagle, 1 #8 Screw 30.8 30.8 18.2
Ponderosa 2#8 Screw 51.7 51.7 24.4
Double 1-10d Smooth or Screw 24.3 24.3 24.2
Eagle Flat Shank Nail Field Clip)
Tile 1-10d Smooth or Screw 19.0 19.0 22.1
Shank Nail Eave Clip)
2-10d Smooth or Screw 35.5 35.5 34.8
Shank Nails Field Clip)
2-10d Smooth or Screw 31.9 31.9 32.2
Shank Nails Eave Clip)
2-10d Ring Shank Nails' 50.3 65.5 48.3
1. Installation with a 4" the headlap and fasteners are located a min. of 2Y2" from head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf)
for Two Patty Adhesive Set Systems
Tile Profile Tile Application Attachment Resistance
Bel Air, Bel Air Double Eagle, Ponderosa, Golden Adhesive' 31.32
Eagle, Ponderosa Double Eagle Flat Tile
1 See manufactures component approval for installation requirements.
2 The Dow Chemical Company TileBond Average weight per patty 13.9 grams.
ICP Adhesives Polyset®AH-160 Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf)
for Single Patty Adhesive Set Systems
Tile Profile Tile Application Attachment Resistance
Bel Air, Bel Air Double Eagle, Ponderosa, Golden ICP Adhesives Polyset®AH-160 118.93
Eagle, Ponderosa Double Eagle Flat Tile ICP Adhesives Polyset®AH-160 40.44
3 Large paddy placement of 45 grams of Pol ProTM
4 Medium paddy placement of 24 grams of Pol ProTM
Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf)
for Mortar Set Systems
Tile Profile Tile Application Attachment Resistance
Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Mortar Set' 43.9
Ponderosa Double Eagle Flat Tile
5 Tile-Tite Roof Tile Mortar.
_____ NOA No.:16-0314.06
4iCa[-91 P .Df.DE CUQUTl f
Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 5 of 9
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See
Detail Below), or following statement: "Miami-Dade County Product Control Approved".
EAGLE1,
FLORIDA
(LOCATED ON UNDERSIDE OF TILE)
OR
EAGLE FL
(LOCATED ON FRONTSIDE OF TILE)
BEL AIR,BEL AIR DOUBLE EAGLE,PONDEROSA,GOLDEN EAGLE,PONDEROSA DOUBLE EAGLE
CONCRETE ROOF TILE LABEL,SUMTERVILLE PLANT
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by AHJ or applicable Building Code in order to properly evaluate the
installation of this system.
NOA No.:16-0314.06
CAM
Expiration Date: 10/05/21
MM
Approval Date: 06/16/16
Page 6 of 9
PROFILE DRAWING
S.
= -
- !
- - j
i
�@ 91 t,r
4
yd4
BEL AIR
17
12- 56
BEL AIR DOUBLE EAGLE
NOA No.:16-0314.06
rfa,�reiwrae cauiurr Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 7 of 9
ti• -
7BI
PONDEROSA
d
g -
1
w�{wry• :.����
PONDEROSA DOUBLE EAGLE
_ NOA No.:16-0314.06
MEN
� QU Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 8 of 9
i
s
GOLDEN EAGLE
END OF THIS ACCEPTANCE
_ NOA No.:16-0314.06
�Ea' �`°wl jw Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 9 of 9