Loading...
HomeMy WebLinkAboutEnergy Calculation Form & Manual J's FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation- Residential Performance Method Project Name: MIRANDE LEO Builder Name: Street 2311 N.44tH STREET Permit Office: City,State,Zip: FT.PIERCE,FL,34946 Permit Number. Owner. Jurisdiction: Design Location: FL,Fort Pierce County:: ST.LUCIE COUNTY(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1104.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1104.00 1`12 b.NIA R= f:2 3. Number of units,if multiple family 1 c.N/A R= ft= 4. Number of Bedrooms 2 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (10Q8.0 sgft.) Insulation Area a�Under Attic(Vented) R=30.0 1008.00 ftZ 6. Conditioned floor area above grade(ft2) 1008 b.NIA R= ftz Conditioned floor area below grade(ft) 0 c:WA R= ft2 11.Ducts R ft= 7. Windows(66.3 sgft.) Description Area a.Sup:Attic,Rat:Attic,AH:UTILITY 6 325 a. U-Factor. Dbl,U=0.40 66.30 ft2 SHGC: SHGC=0.25 b. U-Factor. NIA ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 24.0 SEER:16.00 c: U.-Factor: WA ft SHGC: 13.Heating systems kStu/hr Efficiency d..U-Factor. N/A ft2 a.Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average. SHGC: 0.250 14.Hot water systems a.Electric Cap:40 gallons 8. Floor Types (1008.0 sgft.) Insulation Area ER 0.970 a.Slab.-On-Grade Edge Insulation R=0.0 1008:00 ftZ b. Conservation features b.N/A R= ft' None c.N/A R= ft' 15.Credits. Pstat Glass/Floor Area: 0.066 Total Proposed Modified Loads: 38.88 PASS Total Baseline Loads: 39.18 I hereby certify that the plans and specifications covered by Review of the plans and .Og't S7A)�, this calculation are in compliance with the Flo' a Energy specifications covered by this �+ ,,; _ Code. calculation indicates compliance with the Florida Energy Code. PREP D BY: Before construction is completed DATE`. this building will be inspected fors•'e' compliance with Section 553.908 # I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Code. COD WE OWNERIAGENT' BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 3/6/2017 1:27 PM EnergyGaug FlaWO14 i liant Software Page 1 of 5 FORM R405-2014 PROJECT Title: MIRANDE LEO Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1008 Lot# Owner. Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 2311 N.44tH STREET Permit Office: Cross Ventilation: No County: ST.LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Single-family FL, 34946 New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1008 8064 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated. 1 MASTER BEDROO 196 1568 No 2 1 1 Yes Yes Yes 2 BATH 48 384 No 0 1 Yes Yes Yes 3 BEDROOM 2 180 1440 No 1 1 1 Yes Yes Yes 4 UTILITY 78 624 No 0 1 Yes Yes Yes 5 KITCHEN 132 1056 Yes 0 1 Yes Yes Yes 6 LIVING ROOM 342 2736 No 2 1 Yes Yes Yes 7 HALL 32 256 No 0 1 No Yes Yes FLOORS # Floor'Type Space Perimeter Perimeter R Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MASTER BEDRO 29 ft 0 196 W -- 0 1 0 2 Slab-On-Grade Edge Insulatio BATH 6 ft 0 48 ftz 0 1 0 3 Slab-On-Grade Edge Insulatio BEDROOM 2 34 ft 0 180 ft, 0 1 0 4SIab-On-Grade Edge Insulatio UTILITY 8 ft 0 78 W 0 1 0 5 Slab-On-Grade Edge Insulatio KITCHEN 24 ft 0 132IF .--- 0 1 0 6 Slab-On-Grade Edge Insulatio LIVING ROOM 37 ft 0 342 ft' 0 1 0 7 Slab-On-Grade Edge Insulatio HALL 1 ft 0 32 ft' _ 0 1 0 316120171:27 PM EnergyGaugeG USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 V FORM R405-2014 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1062 ftz 168 ftz Medium 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1008 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) MASTER BEDRO 30 Blown 196 ftz 0.1 Wood 2 Under Attic(Vented) BATH 30 Blown 48 ftz 0.1 Wood 3 Under Attic(Vented) BEDROOM 2 30 Blown 180 ftz 0.1 Wood 4 Under Attic(Vented) UTILITY 30 Blown 78 ft2 0.1 Wood 5 Under Attic(Vented) KITCHEN 30 Blown 132 ftz 0.1 Wood 6 Under Attic(Vented) LIVING ROOM 30 Blown 342 ft2 0.1 Wood 7 Under Attic(Vented) HALL 30 Blown 32 ftz 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing framing Solar Below _1 N Exterior Concrete Block-Ext InsMASTER BE 4.1 12 0 8 0 96.0 ftz 0 0 0.6 0 _2 W Exterior Concrete Block-Ext IndUASTER BE 4.1 17 0 8 0 136.0 ft2 0 0 0.6 0 _3 W Exterior Concrete Block-Ext Insul BATH 4.1 6 0 8 0 48.0 ftz 0 0 0.6 0 4 E Exterior Concrete Block-Ext InfiEDROOM 2 4.1 7 0 8 0 56.0 ftz 0 0 0.6 0 5 S Exterior Concrete Block-Ext InGEDROOM 2 4.1 12 0 8 0 960 ftz 0 0 0.6 0 +_6 W Exterior Concrete Block-Ext InfiEDROOM 2 4A 15 0 8 0 120A ftz 0 0 0.6 0 _7 N Exterior Concrete Block-Ext InsulUT1LITY 4.1 7 0 8 0 66.0 ftz 0 0 0.6 0 _8 E Exterior Concrete Block-Ext Insu1UTILITY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 _9 N Exterior Concrete Block-Ext lnsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 _10 E Exterior Concrete Block-Ext InsuKITCHEN 4.1 12 0 8 0 96.0 ftz 0 0 0.6 0 11 W Exterior Concrete Block-Ext InsuK1TCHEN 4.1 1 0 8 0 8.0 ff2 0 0 0.6 0 _12 E Exterior Concrete Block-Ext InWVING ROO 4.1 19 0 8 0 152.0 ftz 0 0 0.6 0 13 S Exterior Concrete Block-Ext InddVING ROO 4.1 18 0 8 0 144.0 ftz 0 0 0.6 0 DOORS # Omt Door Type Space Storms U Value Width Height Area Ft In Ft In 1 N Insulated UTILITY None .39 3 6 8 20 ftz 2 S Insulated LIVING ROO None .39 3 6 8 20 ftz 316/20171:27 PM EnergyGauge®USA.-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang v # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.4. 0.25 16.4 W 2 It 0 in 1 114 in None None 2 S 5 Vinyl Low-E Double Yes 0A 0.25 16.4 ft2 2 ft 0 in 1 ft 4 in None None 3 E 12 Vinyl Low-E Double Yes 0.4 0.25 16.7 ft2 2 it 0 in 1 ft 4 in None None 4 S 13 Vinyl Low-E Double Yes 0.4 0.25 16:7 ft2 2 It 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 940.8 51.65 97.13 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 17 k8tulhr 1 sys#1 COOLING-SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:16 24 kBtuthr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None UTILITY 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER,SYSTEM' FSEC Collector Storage Cert# Company Name System Model# Collector Model# Area Volume FEF None None ft= DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# 1/ # Location R Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 325 ftz Attic 95 ft2 Default Leakage UTILITY (Default) (Default) 1 1 316120171:27 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 c FORM R405-2014 TEMPERATURES Programable,Thermostat:Y Ceiling Fans: Cooling Jan [ Feb ar A r Ma X Jun Jul AugSep, Oct Nov Dec Heating Jan [X]Feb Mar E P$ f May 4 Jun Jul rI.Aurl Sep Oct Nov Dec Venting Jan [ 1 Feb MM Mar [X] r [ May [ Jun Jul Aug Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 3/6/2017 1:27 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 I FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: MIRANDE LEO Builder Name: Street: 2311 N.44tH STREET Permit Office: City,State,Zip: FT.PIERCE,FL,34946 Permit Number. Owner. Jurisdiction: Design Location: FL,Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal.barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Comers and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim foists Rim joists are insulated and include an air barrier.. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors of subfloordeckin . 9 The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped: Shafts, penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed'. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled. by insulation that on installation readily conforms to the available cavity spaces. ' Garage separation Air sealing shall be provided.between the aces.and conditioned s garage P Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight,IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or Insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls.Fireplaces shall have gasketed doors 316120171:27 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page.1 of 1 FORM R405-2014 ENERGY PERFORMANCE. LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index,the more efficient the home. 2311 N. 44tH STREET, FT. PIERCE, FL, 34946 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1104.00 ft2 b.N/A R= ft' 3. Number of units,if multiple family 1 c.N/A R= ft' 4. Number of Bedrooms 2 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30:0 1008.00 ft2 6. Conditioned floor area(ft 1008 b.N/A R= W 7. Windows" Description Area c.N/A R= ft2 a. U-Factor. Dbl,U=0.40 66.30 f:2 11.Ducts R ft= SHGC: SHGC=0.2$ a.Sup:Attic,Ret:Attic,AH:UTILITY 6 325 b. U-Factor. N/A { SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 24.0 SEER:16.00 SHGC: d. U-Factor. NIA ft2 SHGC: 13.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang.Depth: 2.000 ft. a.Electrie Strip Heat 17.0 COPA.00 Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems 0 gallons a.Slab-On-Grade Edge Insulation R=0.0 1008:00 ft2 a.Electric Cap:4EF:0.97 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building D -tBr ST.q�� Construction through the above energy saving features which will be installed(or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant ,:: ,a Lures. ,,,,, ' U ; Builder Signature: Date: Address of New Home: 2?j(( N. f- Sfi City/FL Zip: �L } ,co o �y � D w1r *Note: This is not a.Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation; contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 316/20171:2.7 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Project Summary Job: -�- wrightsoft � � Date: Mar O6,zon Entire House By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:T72466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM Project • • For. MIRANDE LEO RESIDENCE 2311 N. 44tH STREET, FT. PIERCE, FL 34946 Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 11902 Btuh Structure 8615 Btuh Ducts 3525 Btuh Ducts 5374 Btuh Central vent(69 cfm) 2126 Btuh Central vent(69 cfm) 1139 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 17554 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment'sensible load 14371 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2291 Btuh Ducts 1449 Btuh Central vent(69 cfm) 2886 Btuh Heating Cooling Outside air Area 1008 1008 Equipment latent load 6626 Btuh Volumee(ft3) 8064 8064 Air changes/hour 0.45 0.23 Equipment total load 20998 Btuh Equiv.AVF(cfm) 60 31 Req. total capacity at 0.70 SHR 1.7 ton Heating.Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR40251-1 AHRI ref Coil TEM6AOB3OH21++TDR AHRI ref 7567541 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 5.1 kW Sensible cooling 16800 Btuh Heating output 17448 Btuh Latent cooling 7200 Btuh Temperature rise 20 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.052 cfm/Btuh Air flow factor 0.057 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.70 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. . wrightsoft- Ri ht-Suite®Universal 2017 17.0.14 RSU08101 2017-Mar-06 13: ge 1 9 Page 1 ACCK C:\Users\Quick Calcs\Documents\MI RAND E LEO.rup Calc=MJ8 Front Door faces: S wrightsoft- Right-M Worksheet Job: Entire House Date: Mar 06,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772466-6796 Email:QUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 Exposed wall 138.0 ft 29.0 ft 3 Room height 8.0 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 196.0 ft 5 Room area 1008.0 ft' 196.0 ftz Ty Construction U-value Or HTM Area (ft') Load Area (ft) Load number (Btuh/ft?°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�J - 13A-0ocs 0.143 n--4.00 2.55 240 203 811 516 96 80- 319 203 I�-GD 4A5.20v 0.470 n 13.16 13.55 16 0 215 221 16 0 215 221 11DO 0.390 n 10.92 11.31 21 21 229_ 238 0 0 0 0 V�/ 13A-4ocs 0.143 a 4.00 2.55 312 295 1182 752 0 0 0 0 11 L-1' 4A5-2ov 0.470 a 13.16 34.79 17_ 1_ 220 583_ 0 0_ 0 0 13A-4ocs 0.143 s 4.00 2.55 240 186 744 473 0 0 0 0 4A5-2ov 0.470 s 13.16 13.55 17 17 220 227 0 0 0 0 4A5-2ov 0.470 s 13.16 13.55 16 16 215 221 0 0 0 0 11D.0 0.3-90__s 10.92.- 11.31_ 21 21_ 229__ 238- 0 0__ 0 __0 W 13A-05cs 0.143 w 4.00 2.55 312 312 1249 794 136 136 545 346 _C 1_61330ad__ 0.032.__ 0.90_- 1.68_ _1008 1008 903 1693-_ 190 190 176 329 F 22A-tpl 0.989_ 27.69 0.00_ 1008 1383821 0- 196_ 29 803 0- 6- c)AED excursion 0 0 Envelope loss gain 10041 5955 2057 1100 12 a) Infiltration 1861 510 391 107 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 2 460 Appliances/other 1000 0 Subtotal(lines 6 to 13) 1 11902 8615 2448 1667 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 7 13 14 Subtotal 11902 8615 2456 1680 15 Duct loads 30% 62% 3525 5374 30% 62% 727 1048 Total room load 15428 13989 3183 2728 / Air required(cfm) 800 800 165 156 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .�CGP. wrigF�tsoft- Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Mar-06 1 Page 1 C:\Users\Quick Calcs\Documents\M I RAND E LEO.rup Calc=MJ8 Front Door faces: S g wrightsoft' Right-M Worksheet Job: Entire House Date: Mar06,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BATH BEDROOM 2 2 Exposed wall 6.0 ft 34.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 8.0 x 6.0 ft 12.0 x 15.0 ft 5 Room area 48.0 W 180.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (W) Load number (Btuh/ft'°F) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V+✓j 13A-4ocs 0.143 n 4.00 2.56 0 0 0 0 0 0 0 0 4A5-2ov 0.470 n 13.16' 13.55 0 0 0 0 0 0 0 0 11DO 0390 n %92 11.31 0 0 0 0 0 0 0 0 y/ 13AAocs 0.143 a 4.00 2.55 0- 0 - 0 0 56 56 224 143 11 I G 4A5-2ov _ 0.470 a 13.16 34.79 0_ 0 _ 0 0 0 0 0 0 h13AAor-s 0.143 s 4.00 2.55 0 0 0 0 96 80 319 203 4A5-2ov 0.470 s 13.16 13.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 s 13.16 13.55 0 0 0 0 16 16 215 221 11_D0 __ 0 390 s 10 92_-11 31_ _-0 0 0'_ 0.__-----0-. 0_ 0- __ 0 w 13A-4ocs 0.143 w 4.00 2.55 48 48 192 122 120 120 480 305 - -- -- ---------- - ----- - - - C 16B30ad_ _ 0.032_ 0,90___ 1.68 48 48 43 81. 180 180_ 161 302 F 22A-tpl 0_989 27.69 0.00_ 48_ 6-- 166 0 180 34 942 0 6 c)AED excursion 0 0 Envelope loss/gain 401 203 2342 1175 12 a) Infiltration 81 22 459 126 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 482 225 2800 1530 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 7 13 5 9 14 Subtotal 489 238 2805 1539 15 Duct loads 30% 621/6 145 149 30% 62% 831 960 Total room load 634 187 3636 2499 Air required(cfm) 33 V 22 189 143 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. . A wrightsoft' 2017-Mar-06 1 Right-Suite®Universal 2017 17.0.14 RSU08101 Page ae 2 C:\Users\Quick Calcs\Documents\MI RAND E LEO.rup Calc=MJ8 Front Door faces: S g wrightsoft Right-JO Worksheet Job: Entire House Date: Mar06,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name UTILrrY KITCHEN 2 Exposed wall 8.0 ft 24.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 78.0 ft 11.0 x 12.0 ft 5 Room area 78.0 ft2 132.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V1J - 13A-0ocs 0.143 n 4.00 2.55 - 56 -- --35 140----89 - 88- 88--- 352 - --224 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 11D0 0.390 n 10.92 11.31_ 21 _ 21 229_ 238_ 0 0 0 0 V�J 13A-0ocs 0.143 a 4.00 2.55 8 8 32 20 96 96^ 384 244 11 �G 4A5.2ov 0.470 a 13.16 ___ 34.79__-0_ 0 0 0____ 0_ 0_ 0 0 13A4ocs 0. s 4. 6 4A5-2ov 0.470470 s 13.116 133.55 0 0 0 0 0 0 0 0 .55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 s 13.16 13.55 0 0 0 0 0 0 0 0 h _ 0.390 s_ 10.92. 11.31 0. 0 0 0- 0_____ 0___ 0 W _13A-0ocs 0.143 w 4.00 Z55_ 0 _ 0 0 0 8 8 32 20 _C -_1613_30ad - 0_032 0.90_ 1_.68 78 78 -- 70_ 131__ 132 132. 118 F 22A-tl) _ 0_989 - 27.69 0 00 78__ 8-___222 0 132 24-__ 665_ 0 6 c)AED excursion 0 0 Envelope loss/gain 693 478 1552 710 12 a) Infiltration 108 30 324 89 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1000 Subtotal(lines 6 to 13) 801 508 11875 1799 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 801 508 1875 1799 15 Duct loads 30% 62% 237 317 30% 62% 555 1122 Total room load 1038 824 2431 2921 Air required(cfm) 54 ✓ 47 126 0( 167 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2017-Mar-06 13:28:17 Right-Suite@ Universal 2017 17.0.14 RSU08101 Page 3 C:\Users\Quick Calcs\Docunents\MI RAND E LEO.rup Cale=MJ8 Front Door faces: S 1 wrightsoft, RighW@ Worksheet Job: Entire House Date: Mar 06,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name LIVING ROOM HALL 2 Exposed wall 37.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 18.0 x 19.0 ft 4.0 x 8.0 ft 5 Room area 342.0 ft2 32.0 ft2 Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft2-OF) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool V+/ 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 !L-Cp 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 6 11D0 0.390 n 10.92_ 11.31 0 0 0 0 0 0 0 0 yJ 13AAocs 0.143 a 4.00 2.55 152 135 542 344 0 0 0 0 11 �G 4A5-2ov _ 0.470 a 13.16 34.79 17 1 220 583 0 0_ 0 _ 0 UlJ 13AAocs 0.143 s 4.00 2.55 144 106 425 270 0 0 0 0 4A5-2ov 0.470 s 13.16 13.55 17 17 220 227 0 0 0 0 4A5-2ov 0.470 s 13.16 13.55 0 0 0 0 0 0 0 0 ._ 11Dl0 _0.3-90_s 10 92-____11 31___21.__ 21- 229__238 0__0_ 0- 0 w 13AAocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 LF�C22A-tol 16B30ad _ __ 0.032 0.90 1.68342 342 306 575. 32 32 __29_-_54 0,989. 27.69 0,00 _342 37 _1025 0 32_ 0_ 0 0 6 c)AED excursion 0 0 Envelope loss/gain 2968 2236 29 54 12 a) Infiltration 499 137 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 3467 2833 29 54 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 10 18 -29 -54 14 Subtotal 3477 2851 0 0 15 1 Duct loads 30% 62% 1030 1778 30% 62% 0 0 Total room load 4506 4629 0 0 Air required(cfm) 234 265 0 0 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. AWK wrrfg~ � 2017-Mar-06 1 Right-Suite@ Universal 2017 17.0.14 RSU08101 Page ae 4 C:\Users\Quick Calcs\Documents\MI RAND E LEO.rup Calc=MJ8 Front Door faces: S g Duct System Summary Job: 1- wrightsoft® Date: Mar06,2017 Entire House By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466.6796 Email:QUICKCALCS AOL.COM Project • • For. MIRANDE LEO RESIDENCE 2311 N. 44tH STREET, FT. PIERCE, FL 34946 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.363 in/100ft 0.363 in/100ft Actual air flow 800 cfm 800 cfm Total effective length(TEL) 138 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (Cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk BATH h 634 33 222 0.365 4:0 Ox0 VIFx 22.0 115.0 st1 BEDROOM 2 h 3636 189 143 0.363 f Q. Ox0 VIFx 22.8 115.0 st1 KITCHEN c 2921 126 167 0.489 lzz�7-.0 Ox 0 VIFx 7.2 95.0 LIVING ROOM c 2314 117 132 0.397 7.0 Ox 0 VIFx 10.8 115.0 st1 LIVING ROOM-A c 2314 117 132® 0.381 7._0_ Ox0 VIFx 16.2 115.0 st1 MASTER BEDROOM h 3183 165 156 0.471 c--8:0 Ox 0 VIFx 11.0 95.0 UTILITY h 1038 54 47 0.493 40 Ox 0 VIFx 6.4 95.0 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 455 430 0.363 579 12.0 0 x 0 VinlFlx Return Branch, • Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb1 Ox0 800 800 0 0 0 0 Ox 0 VIFx 2017-Mar-06 13:28:18 wrightsoft Right-Suite®Universal 2017 17.0.14 RSU08101 Pagel �'� C:\Users\Quick Calcs\Documents\M I RAND E LEO.rup Cale=MJ8 Front Door faces: S