Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Leo Residence Demo/Re-build Project Address: 406 N. 40th Street, Fort Pierce, FL 34947 Permit #: Occupancy Type: R3 Construction Type: VB INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure.' * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2014 Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: _I ^ II III • IV Exposure Category: B � C D 4. Design Wind Velocity 124 mph X ASD LRFD End Zone Width: 4 ft 5. Mean Roof Height 15 ft Roof Pitch: 5 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +13.6/-27.8 Zone 2: +17.7/-43.1 Zone 3: +19.31-79.0 Zone 4: +29.4i-31.3 Zone 5: +30.0i-37.9 Garage: N/A 7. Design Loads: Floor: 40 PSF Roof/Dead: 17 PSF Roof/Live: 20 Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these njan.� provide adequate resistance to the design forces specified: ��' ry. ,' :-' ,.,6Jr ROBE RT1=ONB.,c.R RA0006280 Print Names,. a Cert # & Co. Cert Auth. Robert IFSonberg D,t,: 2017.03.151R1:50: 0-04'00 _, ' Signature, Date, and Seal RFS ARCHITECTS,113_BE P. Company Name,& Address.: 4 Revised 07/25/2014 - .'