HomeMy WebLinkAboutProduct Approval (5) 2l7/2017 Florida Building Code Online
a."t
• iness a1 1 oe .
BCIS Home I Log In User Registration Hot Topics submit Surcharge Stats&Facts Publications FBC Staff ' BCIS Site Map Links I •Search
k,
Flolitla
' Product Approval
USER:Public User
L rt Jt
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL1956-R12
Application Type Editorial Change
Code Version `2 114
Application Status Aproved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived Q
Product Manufacturer TAMKO Building Products, Inc.
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri—eden@tamko.com
Authorized Signature Kerri Eden
kerri_eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext2305
kerri_eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category -Roofing
Subcategory (Asphalt Shingles
Compliance Method Certification Mark or Listing
Certification Agency UL LLC
Validated By Robert J. M. Nieminen, PE
�✓ Validation Checklist-Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
SHOP DRAWINGS
y. REVIEWED AND APPROVED
Product Approval Method:; Metho6p1 Option A
ROSERT F.SONBERG. IECT#6280
hltps://www.floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgsp/o2fmGFoyT6raQp/o2bp/o2bCX5ulUhEUshlcmF3nE3F2ytsDnaSgA/o3dp/o3d 114
1
2l7/2017 Florida Building Code Online
Date Submitted 09/17/2015
Date Validated 10/06/2015
Date Pending FBC Approval
Date Approved 10/09/2015
Summary of Products
FL# Model,Number Description
or Name
1956.1 Elite Glass-Seal A three tab asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.odf
Approved for use outside FL1956 R12 C CAC UL certification 10-11-12.odf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 09/17/2018
Design Pressure: N/A Installation Instructions
Other:Asphalt shingles shall FL1956 R12 II Glass Seal Elite Glass Seal aoo inst.odf
be used only on roof slopes of Verified By: Robert Nieminen 59166
2:12 or greater. Nails must be Created by Independent Third Party: No
used as the method of Evaluation Reports
attachment. Created by Independent Third Party:
1956.2 Glass-Seal A three tab asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.1)df
Approved for use outside FL1956 R12 C CAC UL certification 10-11-12.odf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 09/17/2018
Design Pressure: N/A Installation Instructions
Other:Asphalt shingles shall FL1956 R12 II Glass Seal Elite Glass Seal aoo inst.odf
be used only on roof slopes of Verified By: Robert Nieminen PE 59166
2:12 or greater. Nails must be Created by Independent Third Party: No
used as the method of Evaluation Reports
attachment. Created by Independent Third Party:
1956,3 (Heritage A'.'dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015 odf
Approved for use outside FL1956 R12 C CAC UL certification 10-11-12.gdf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 09/17/2018
Design Pressure: N/A Installation Instructions
Other:Asphalt shingles shall FL19S6 R12 II Heritage D F I P ann inst.odf
be used only on roof slopes of FL1956 R12 II Heritage F aoo inst.odf
2:12 or greater. Nails must be FL1956 R12 I1 Heritage T aoo inst.odf
used as the method of Verified By: Robert]. M. Nieminen FL 59166
attachment. Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
1956.4 Heritage 30 A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.13df
Approved for use outside FL1956 R12 C CAC UL certification 10-11-12.1)df
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 09/17/2018
Design Pressure:N/A Installation Instructions
Other:Asphalt shingles shall FL1956 R12 II heritage 30 am) inst aoril 10.odf
be used only on roof slopes of FL19S6 R12 II heritage 30 arm inst f aoril 10.odf
2:12 or greater. Nails must be Verified By: Robert Nieminen PE 59166
used as the method of Created by Independent Third Party: No
attachment. Evaluation Reports
Created by Independent Third Party:
1956.5 Heritage 50 A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015 odf
Approved for use outside FL1956 R12 C CAC UL certification 10-11-12.odf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 09/17/2018
Design Pressure: N/A Installation Instructions
Other:Asphalt shingles shall FL1956 R12 II heritage 50 ago inst aoril 10.odf
be used only on roof slopes of FL1956 R12 II heritage 50 aoo inst f aoril 10.odf
2:12 or greater. Nails must be Verified By: Robert Nieminen PE 59166
' used as the method of Created by Independent Third Party: No
attachment. Evaluation Reports
Created by Independent Third Party:
https:/Avm.floridabuilding.org/pr/pr_ppp dtl.aspx?param=wGEVXQwtDgs%2fmGFoyTSraQ%2b%2bCX5ulUhEUsMcmF3nE3F2ytsDnaSgA%3d%3d 214
2/7/2017 Florida Building Code Online
1956.6 Heritage Premium A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.pdf
Approved for use outside FL1956 R12 C CAC UL certification 10-11-12.ndf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 09/17/2018
Design Pressure: N/A Installation Instructions
Other:Asphalt shingles shall FL1956 R12 II Heritage Premium D P aoo inst.pdf
be used only on roof slopes of FL1956 R12 II Heritage Premium F aoo inst.odf
2:12 or greater. Nails must be FL1956 R12 II Heritage Premium T aoo inst.odf
used as the method of Verified By: Robert Nieminen 59166
attachment. Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
1956.7 Heritage Vintage A heavy weight dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015 odf
Approved for use outside FL1956 R12 C CAC UL shingle matrix.pdf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 09/17/2018
Design Pressure: N/A Installation Instructions
Other:Asphalt shingles shall FL1956 R12 II Heritage Vintage aoo inst.pdf
be used only on roof slopes of Verified By: Robert J. M. Nieminen PE 59166
2:12 or greater. Nails must be Created by Independent Third Party: No
used as the method of Evaluation Reports
attachment. Created by Independent Third Party:
1956.8 Heritage Vintage Hip and ridge shingles
12 X 12 Hip and
Ridge
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015 odf
Approved for use outside FL1956 R12 C CAC UL shingle matrix odf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 09/17/2018
Design Pressure: N/A Installation Instructions
Other:Asphalt shingles shall FL1956 R12 II TAMKOCR) Heritage(g) 12 x 12 Hip and Ridge Application Instructions odf
be used only on roof slopes of Verified By: Robert 1. M. Nieminen PE 59166
2:12 or greater. Nails must be Created by Independent Third Party: No
used as the method of Evaluation Reports
attachment. Created by Independent Third Party:
1956.9 Heritage A dimensional asphalt shingle.
Woodgate
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015 odf
Approved for use outside FL1956 R12 C CAC UL certification 10-11-12 odf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 09/17/2018
Design Pressure: N/A Installation Instructions
Other:Asphalt shingles shall FL1956 R12 II Heritage Woodgate D arm inst.ndf
be used only on roof slopes of FL1956 R12 II Heritage Woodgate F ang inst odf
2:12 or greater. Nails must be Verified By: Robert Nieminen 59166
used as the method of Created by Independent Third Party: No
attachment. Evaluation Reports
Created by Independent Third Party:
1956.10 Heritage XL A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015 odf
Approved for use outside FL1956 R12 C CAC UL certification 10-11-12 odf
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 09/17/2018
Design Pressure:N/A Installation Instructions
Other:Asphalt shingles shall FL1956 R12 II heritage xl aoo inst d april 10 odf
be used only on roof slopes of FL1956 R12 II heritage xl aoo inst f april 10 odf
2:12 or greater. Nails must be Verified By: Robert Nieminen PE 59166
used as the method of Created by Independent Third Party: No
attachment. Evaluation Reports
Created by Independent Third Party:
1956.11 Hip and Ridge Hip and ridge shingles
Shingles
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015 odf
Approved for use outside FL1956 R12 C CAC UL certification 10-11-12 odf
https:/Avww.floridabuilding.org/pr/pr app dfl.aspx?param=wGEVXQwtDgs%2fmGFoyT6raQ%2b%2bCX5ulUhEUshlcmF3nE3F2ytsDnaSgA%3d%3d 34
2f7/2017 Florida Building Code Online
HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 09/17/2018
Design Pressure: N/A Installation Instructions
Other: Hip and Ridge shingles FL1956 R12 II 12.25x12 Hin and Ridge.Ddf
shall be used only on roof FL1956 R12 II 12 x 12 HiD Ridge ADolication Instructions.Ddf
slopes of 2:12 or greater. Nails FL1956 R12 II 12-1-4x12 HiDRidge Sealant Dab Illustrations.Ddf
must be used as the method of FL1956 R12 II 12x12 HiDRidge Sealant Dab Illustrations.cdf
attachment. Verified By: Robert Nieminen 59166
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
Back Next
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. ::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:
® M ZZ
-Credit Card
Safe
https:/ANww.floridabuilding.orgipr/pr_app dtl.aspx?param=wGEVXQwtDgsg/o2fmGFoyT6raQ%2bg/o2bCX5LdUhEUshicmF3nE3F2ytsDnaSgAg/o3dg/o3d 4/4
® Application Instructions for FORMERLY HERITAGE®30
TAMKO HERiTArE®
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED.
' TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM
FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS.FAILURE TO FOLLOW THESE INSTRUCTIONS WILL ADVERSELY
AFFECT COVERAGE UNDER THE LIMITED WARRANTY.SEE THE LIMITED WARRANTY FOR DETAILS.
THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER.
IN COLD WEATHER(BELOW 40"F),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES.
IMPORTANT:It is not necessary to remove the plastic strip from the back of the shingles.
1.ROOF DECK &FASTENERS
These shingles are for application to roof decks consisting of plywood WIND CAUTION: Extreme wind velocities can damage these
or sheathing boards capable of receiving and retaining fasteners,and shingles after application when proper sealing of the shingles does
to inclines of not less than 2 in.per foot.For roofs having pitches 2 in. not occur.This can especially be a problem if the shingles are applied
per foot to less than 4 in.per foot,refer to special instructions titled in cooler months or in areas on the roof that do not receive direct
"Low Slope Application".For roofs having pitches greater than 21 in. sunlight.These conditions may impede the sealing of the adhesive
per foot,refer to special instructions titled"Mansard Roof or Steep strips on the shingles.The inabilityto seal down may be compounded
Slope Roof'.Shingles must be applied properly.TAMKO assumes no by prolonged cold weather conditions and/or blowing dust.In these
responsibility for leaks or defects resulting from improper application, situations,hand sealing of the shingles is required.To insure quicker
or failure to properly prepare the surface to be roofed over. sealing, apply 4 quarter-sized dabs of TAM-PRO@ SBS Flashing
Cement,TAMKO or TAM-PRO@ Plastic Roof Cement, or TAMKO
NEW ROOF DECK CONSTRUCTION:Roof deck must be smooth, Tam-Seal Adhesive,meeting ASTM D 4586,Type 1,on the back of
dry and free from warped surfaces. It is recommended that metal the shingle 1 in.(25mm)and 13 in.(330mm)in from each side and
drip edges be installed at eaves and rakes. 1 in.(25mm)up from the bottom of the shingle.Press shingle firmly
into the adhesive.For maximum wind resistance along rakes,install
PLYWOOD: All plywood shall be exterior grade as defined by any TAMKO starter shingle including sealant or cement shingles to
APA - The Engineered Wood Association. Plywood shall be a the underlayment and each other in a 4 in.(102mm)width of TAM-
minimum of 3/8 in.thickness and applied in accordance with the PRO@ SBS Flashing Cement,TAMKO or TAM-PRO® Plastic Roof
recommendations of APA-The Engineered Wood Association. Cement,orTAMKO Tam-Seal Adhesive.Caution:Apply ONLY a thin
SHEATHING BOARDS: Boards shall be well-seasoned tongue- uniform layer of adhesive less than 1/8 in.(3mm)thick.Excessive
and-groove boards and not over 6 in.nominal width.Boards shall amounts can cause blistering of the shingles and may soften the
be a 1 in. nominal minimum thickness. Boards shall be properly asphalt in certain underlayments resulting in the asphalt flowing,
spaced and nailed. dripping and staining.Shingles must also be fastened according to
the fastening instructions described below.
Z.VENTILATION Correct placement of the fasteners is critical to the performance of
the shingle.If the fasteners are not placed as shown in the diagram
Inadequate ventilation of attic spaces can cause accumulation of and described below,this will result in the termination of TAMKO's
moisture in winter months and a build up of heat in the summer. liabilities under the Limited Warranty.TAMKO will not be responsible
These conditions can lead to: for damage to shingles caused by winds in excess of the applicable
1.Vapor Condensation mph as stated in the Limited Warranty.See Limited Warranty on the
2.Buckling of shingles due to deck movement. wrapper or tamko.com for details.
3.Rotting of wood members. FASTENING PATTERNS:Fasteners must be placed 6-1/8 in.from
4.Premature failure of roof. the bottom edge of the shingle,penetrating through the common
bond,and located horizontally as follows:
To insure adequate ventilation and circulation of air,the ventilation 1)Standard Fastening Pattern.(For use on decks with slopes 2
system must include inlets and outlets.This may be accomplished with in.per foot to 21 in.per foot.)One fastener 1 in.from each end and
a combination of ridge and soffit vents or by using gable end vents. one 13-1/2 in.from each end of the shingle for a total of 4 fasteners.
FHA minimum property standards require one square foot of net free (See Standard Fastening Pattern illustrated below).
ventilation area to each 150 square feet of space to be vented.This
may be reduced to one square foot of ventilation area per 300 square STANDARD FASTENING PATTERN
feet if at least 40%and not more than 50% of venting is provided FASTENERS MAIL ZONE
not more than 3 feet below the ridge or if a Class I or II vapor barrier COMMON
is installed on the warm in winter side of the ceiling in climate zones BOND
6,7,and 8 as recommended by the 2012 International Residential 6-1/8
[EXPOSURE 5-5/8"
Code.For more information consult your design professional.If the
ventilation openings are screened,the total area should be doubled. 1 12-1/2"—+�-12 3/8" — 12-1/2„� h 1"
IT IS PARTICULARLY IMPORTANT TO PROVIDE
ADEQUATE VENTILATION. (Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 1
® (CONTINUED from page 1) FORMERLY HERITAGE®30
TAMKO HEmAn"'
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
2) Mansard Fastening Pattern. (For use on decks with slopes be a minimum of 1-1/4 in.for new construction and 1-1/2 in.for
greater than 21 in.per foot.)One fastener 1 in.from each end and reroofing thus allowing a minimum deck penetration of 3/4 in.The
one fastener 8-1/2 in.from each end and one fastener 16 in.from
each end for a total of 6 fasteners per shingle.(See Mansard and Properly Driven Improperly Driven
undeNdven overdridvv en crooked
High Wind Fastening Pattern illustrated below.) H Asphalt
MANSARD AND HIGH WIND WARRANTY FASTENING PATTERN Shin" I _�Q
gles
FASTENERS NAILZONE "E '--Decking
COMMON
BOND
s�B" [EXKPOSURES 5/8" crown of the staple must be parallel to the length of the shingle.
The staple crown should be driven flush with the shingle surface.
tg•I Ira-irz'l.h -�rz"►�. -ys'+I. -trz^►�r�-uz"+� �.—+° Staples that are crooked,underdriven or overdriven are considered
3)High Wind Warranty Fastening Pattern.(For High Wind Warranty improperly applied.
Application requirements) One fastener 1 in.from each end. One CAUTION: ALL FASTENERS MUST BE DRIVEN INTO THE
fastener 8-1/2 in.from each end and one fastener 16 in.from each NAIL ZONE COMMON BOND AS SHOWN IN THE FASTENING
end for a total of six(6)fasteners per shingle. In addition to this PATTERN DIAGRAMS.
shingle fastening pattern requirement for High Wind Application,
TAMKO also requires the use of TAMKO starter shingles including 4.UNDER16AYMENT
sealant strip at eaves and rakes.Alternatively,along rakes,cement UNDERLAYMENT: An underlayment must be applied over the
shingles to the underlayment and each other in a 4 in. (102 mm) entire deck before the installation of TAMKO shingles.Failure to add
width of TAM-PRO®SBS Flashing Cement,TAMKO or TAM-PRO@ underlayment can cause premature failure of the shingles which is
Plastic Roof Cement,or TAMKO Tam-Seal Adhesive.Caution:Apply not covered by TAMKO's Limited Warranty.
ONLY a thin uniform layer of adhesive less than 1/8 in.(3mm)thick.
Excessive amounts can cause blistering of the shingles and may Products which are acceptable for use as underlayment are:
soften the asphalt in certain underlayments resulting in the asphalt Asphalt Saturated Felt Underlayments:
flowing,dripping and staining.
• SuperX 30TM Underlayment
High Wind Application is offered on new construction or complete • TAMKO No.15 Asphalt Saturated Organic Felt
tear-off applications only.It is not offered for recover applications. • Any TAMKO non-perforated asphalt saturated organic felt
If High Wind Application requirements are not followed, the High • A non-perforated asphalt saturated organic felt which meets
Wind Application Warranty MPH,as stated on Table I in the Limited ASTM:D226,Type I or II or ASTM D4869
Warranty,reverts to the Standard Application Wind Warranty MPH
limit. (See Mansard and High Wind Fastening Pattern illustrated Specialty Underlayments:
above.) • Tam-Shield® Synthetic Underlayment or Synthetic Shield
Underlayment
NAILS:TAMKO recommends the use of nails as the preferred method . TAMKO TW Metal and Tile Underlayment,TW Underlayment
of application. Standard type roofing nails should be used. Nail and Moisture Guard Plus® (additional ventilation may be
shanks should be made of minimum 12 gauge wire,and a minimum required. Contact TAMKO's Technical Services Department
head diameter of 3/8 in.Nails should be long enough to penetrate for more information.)
3/4 in.into the roof deck.Where the deck is less than 3/4 in.thick, . A self-adhesive underlayment designed for use with asphalt
the nails should be long enough to penetrate completely through shingles which meets ASTM D1970.
plywood decking and extend at least 1/8 in.through the roof deck.
Drive nail head flush with the shingle surface. For Asphalt Saturated Felt Underlayments:
Apply the felt when the deck is dry.On roof decks with slopes
properly Driven Improperly Driven 4 in. per foot and greater apply the felt parallel to the eaves
Z Nil'min diameter underdrlven overdriven —ked lapping each course of the felt over the lower course at least
,Asphalt 2 in.Where ends join,lap the felt 4 in.If left exposed,the felt
PEW Shingles
E} } ��ng
1/4'nominal may be adversely affected by moisture and weathering.Laying
1 } of the felt and the shingle application must be done together.
straight,good penetration. Inadequate too deep,cute inadequate For All Other Specialty Underlayments:
and gush with shingle aurf— panatrade. into shingle anchorage On roof decks with slopes 4 in. per foot and greater apply
the underlayment parallel to the eaves in accordance
STAPLES:If staples are used in the attaching process,follow the with underlayment written application instructions. The
above instructions for placement.All staples must be driven with underlayment should not be left exposed for a longer period of
pneumatic staplers.The staple must meet the following minimum time than is specified in the underlayments written application
dimensional requirements.Staples must be made from a minimum instructions.The final roof covering must be installed before
16 gauge galvanized wire.Crown width must be at least 15/16 in. the structure is exposed to adverse weather conditions,such
(staple crown width is measured outside the legs).Leg length should as wind driven rain,high wind,hail,ice storms,etc. (Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19n4
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.Com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 2
® (CONTINUED from page 2) FORMERLY HERITAGE®30
ffTA:IIWKOA HERITAGE®
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Dallas,TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
In areas where ice builds up along the eaves or a back-up of water of shingle to start the fourth course and use the remaining 10-3/8
from frozen or clogged gutters is a potential problem,TAMKO's in.piece to begin the fifth course.Continue up the rake in as many
Moisture Guard Plus®, TW Metal and Tile Underlayment or TW rows as necessary using the same formula as outlined above.
Underlayment (or any specialty eaves flashing product) may be The butt of the shingle should be aligned with the top edge of the
applied to eaves,rakes,ridges,valleys,around chimneys,skylights sawtooth of the underlying shingle for a 5-5/8 in. exposure (see
or dormers to help prevent water damage. Contact TAMKO's shingle application drawing illustrated on this panel). When you
Technical Services Department for more information. make your final cut at the roof's edge,flip any pieces that are 8 in.or
Substitute products as shingle underlayment should not be used. longer back onto the roof.These pieces can be worked in anywhere
without creating zippers or color variations.
S.APPLICATION INSTRUCTIONS NOTE:Do not align joints of shingle courses when working in cut
STARTER COURSE:Astarter course may consist of TAMKO Shingle pieces.Joints should be no closer than 4 in.from one another.
Starter,TAMKO 10-inch Starter or self-sealing 3-tab shingles.If self-
sealing 3-tab shingles are used,remove the exposed tab portion and
install with the factory applied adhesive adjacent to the eaves.Attach Cut your first coarse shingle to make 29'and a 10 318"
length.Cut a second shingle to make a 23"and
the starter course with approved fasteners along a line parallel to a1e318"length. y
and 1.5 in.to 3 in.above the eaves edge.The starter course should 29' 110 3/8'
overhang both the eaves and rake edges 1/4 in.to 3/8 in.if drip edge
flashing is not used along the eaves or rakes.If drip edge flashing 23. iB 3r8'
is present,install shingles even with the drip edge.
For maximum wind resistance slong rakes.Install any _ a
TAMKO starter shingle including sealant or cement shingles _
toundedeymem and each other in a 4'(102 rare)width of -
TAM-PROD SBS Flashing Cement,TAMKO or TAM-PROS UndedayrtxmI Deck
Plastic Roof Cement,er TAMKO TemSeal Adhesive. ( gasmng w
( asphalt seN,ated fell
Dripad e Begin appllcatien with a NII length shingle.
_______________________________________________ .Then laY Your 29".23°,183/8°and 103/8°lengths
Rake As You can see,face shingles with two cuts
- C make fare courses.
Fasteners \
totaled 1-IFZ to 3'
from rake edge Continue working your way across the rm,.When you make your
___ ------ 3.final at at the hours edge,IOp any pieces Nat are 8-or longer
back onto the rs r These riabo can be worketl In anywhere without
\ NOTE: o notaorcobi variations.
NINE:Do not ellgn joints of shingle courses when working in
Start first shin with 12 shingle Stores,std Eave Dd edge cut places.Joints should be no closer than 4"Imm one another,
p win ul trips overhang adh sealing ]..led C 9
m ships
In then follow offs with NII eaves and rakes adeesne 1-ire t
snips In rider lo offset with the flash to 3ra'it se drip edge aOsidomd 1-12'to 3'
lust shingle course, flashing sh present 11 adap along ee from cave edge
install nge-with °rake°°g° B.LOW SLOPE APPLICATION
drip edge.
SHINGLE APPLICATION:Start the first course with afull size shingle On pitches 2 in.per foot to 4 in.per foot cover the deck with two
and overhang the rake edge 1/4 in.if drip edge is not present.If layers of underlayment. Begin by applying the underlayment in a
drip edge is present,align shingle edge with drip edge flashing.Cut 1/2-sheet width along the eaves and overhanging the drip edge
10-3/8 in.from a full shingle to form a shingle 29 in.long.Use this by 1/4 to 3/4 in.Place a full-sheet width over the 1/2-sheet width
to start the second course(see diagram below).Cut a 23 in.long starter piece,completely overlapping it.All succeeding courses will
shingle to start the third course.Use the remaining 16-3/8 in.piece be positioned to overlap the preceding course by 1/2-sheet width.
If winter temperatures average 25°F or less, thoroughly cement
taste the laps of the entire underlayment to each other with TAM-PRO
or TAMKO Plastic Roof Cement from eaves and rakes to a point
* of a least 24 in. inside the interior wall line of the building.As an
eo89 Isle"repeat 10-3!e^ alternative,TAMKO's Moisture Guard Plus®,TW Metal and Tile
23"IFS Underlayment, or TW Underlayment self-adhering underlayment
W'Amay be used in lieu of the cemented felts.
WM�29"..
rake F " 1 23" 7.MANSARD ROOF OR STEEP SLOPE ROOF
11»!e If the slope exceeds 21 in.per foot(60),each shingle must be sealed
sth coarse with TAM-PRO® SBS Flashing Cement, TAMKO or TAM-PRO®
d'h course
1s a" W 16-3!e^ Plastic Roof Cement, or TAMKO Tam-Seal Adhesive immediately
y upon installation.Quarter-sized dabs of cement or adhesive must
3rd coarse ., 'Yy uy ,. be applied to shingles with a 5-5/8 in.exposure,use 6 fasteners per
zna cearsa 29� 2e° shingle.See Section 3 for the Mansard Fastening Pattern.
1st course Fo))' 10-318"
eave (Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.eom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
' Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 3
® (CONTINUED from page 3) FORMERLY HERITAGE®30
TEA IM: K O 1 HERITAGE®
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Dallas,TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
a.m-ROOFING 9.VA1666Y APPLICATION
Before re-roofing,be certain to inspect the roof decks.All plywood shall Over the shingle underlayment,center a minimum 36 in.wide sheet of
meet the requirements listed in Section 1. Moisture Guard Plus®,TW Metal&Tile Underlayment,or a minimum
It is not recommended to install laminated asphalt shingles directly 50 lb. roll roofing in the valley. Nail the underlayment only where
over existing laminated shingles due to the unevenness of the existing necessary to hold it in place and then only nail the outside edges.
multi-layered shingles.The performance of the sealant feature may be IMPORTANT:PRIOR TO INSTALLATION WARM SHINGLES TO
compromised,preventing the shingles from sealing properly.It is PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING
acceptable to install laminated shingles over existing three-tab strip SHINGLES TO FORM VALLEY.
shingles which are flat and essentially intact.Nail down or remove curled
or broken shingles from the existing roof.Replace all missing shingles After valley flashing is in place:
with new ones to provide a smooth base.Shingles that are buckled Apply the first course of shingles along the eaves of one of the
usually indicate warped decking or protruding nails.Hammer down all intersecting roof planes and across the valley.
protruding nails or remove them and refasten in a new location.Remove
all drip edge metal and replace with new. Note:For properflow of water overthe trimmed shingle,always
If re-roofing over an existing roof where new flashing is required to start applying the shingles on the roof plane that has the lower
protect against ice dams(freeze/thaw cycle of water and/orthe backup slope or less height.
of water in frozen or clogged gutters),remove the old roofing to a point . Extend the end shingle at least 12 in.onto the adjoining roof.
at least 24 in.beyond the interior wall line and apply TAMKO's Moisture Apply succeeding courses in the same manner,extending them
Guard Plus® TW Metal and Tile Underlayment,or TW Underayment. across the valley and onto the adjoining roof.
Contact TAMKO's Technical Services Department for more information.
Measurements will vary when nesting over an existing 5 in.exposure • Press the shingles tightly into the valley.
single roof:Call TAMKO Technical Services for further information. • Use normal shingle fastening methods.
The nesting procedure described below is the preferred method for Note:No fastener should be within 6 in.of the valley centerline,
reroofing over existing metric size shingles with a 5-5/8 in.exposure. and two fasteners should be placed at the end of each shingle
See description below: crossing the valley.
Starter Course:Remove the tabs and an additional portion from the . To the adjoining roof plane,apply one row of shingles vertically
head of a full size shingle so that its height is equal to the exposure of facing the valley and 2 in.back from the valley centerline.
the existing shingles.Position the resulting strip over the existing roof
edge(with the factory-applied adhesive strip along the eaves). Cut Note: For a neater installation, snap a chalkline over the
approximately 6 in.from the rake end and apply the remaining portion at shingles for guidance.
the eaves.Continue the starter strip by applying full length shingle strips To complete the valley, apply shingles on the adjoining roof
cut to height as above,evenly along the existing roof at the eaves.The plane by positioning the tip of the first shingle of each row at
existing roof should overhang the eaves far enough to carry water the 2 in.point from the centerline where the edge of the vertical
off into the gutter.If this is not the case,curt and apply the starter shingle has been applied,covering the vertical shingle.
strip so that it will provide sufficient overhang for proper drainage.
Exisgng shingles
Minimum 36°wide sheet valley centerline
5 Ma• of Moisture Guard Plus, +
TW Metal& Extra nail in
131/4• 1 /d" Tile or 50 lb.or end of shingle
/4• heavier roll roofing
Extend end shingle
12'-18'beyond
Drip edge valley centerline
/ Drip edge
New shingles Undedayment No fasteners within
6'of centerline
5 SM' 3 5/a•exposure /
expowre
First Course:Remove an amount from the butt edge of afull-size shingle
so that the remaining portion of the shingle fits between the butts of the
existing third course.This course must also be applied evenly along the
eaves edge of the new starter strip. Place tip of shingle on the edge of
the vertical shingle,2 inches back
Second and Succeeding Courses:Remove 10-3/8 in.from the rake from valley centerline and covering
end of the first shingle in the second course,and continue with full the vertical shingle.
width shingles for the remainder of the course,placing the top edge of
each new shingle against the butt edge of the old shingle in the course FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE
above.This method should create an exposure of 5-5/8 in.afterthe first CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT
course.When beginning the succeeding courses continue to follow the 800-641-4691.
Heritage application instructions.(See section 5).
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 4
® (CONTINUED from page 4) FORMERLY HERITAGE®30
TAMKO HER mum
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
10.HIP AND RIDGE FASTENING DETAIL
Apply the shingles with a 5-1/8 in.exposure beginning at the bottom
of the hip or from the end of the ridge opposite the direction of the
prevailing winds.Secure each shingle with one fastener on each side,
5-5/8 in.back from the exposed end and 1 in.up from the edge.
TAMKO recommends the use of TAMKO Hip & Ridge shingle
products.Where matching colors are available,it is acceptable to
use TAMKO's Elite Glass-Seal shingles cut down to 12 in.pieces.
Fasteners should be 1/4 in.longer than the one used for shingles
IMPORTANT: PRIOR TO INSTALLATION, CARE NEEDS TO BE
TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE
BENDING SHINGLE IN COLD WEATHER.
Direction of prevailing wind
Start 5-1/8"exposure
here-
1"
Fastener
II r`5 5/8u
Start
here 5-118"exposure
THESE ARE THE MANUFACTURER'S APPLICATION
INSTRUCTIONS FOR THE ROOFING CONDITIONS
DESCRIBED.TAMKO BUILDING PRODUCTS, INC.ASSUMES
NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
DEFECTS RESULTING FROM FAILURE TO FOLLOW THE
MANUFACTURER'S INSTRUCTIONS. FAILURE TO FOLLOW
THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE
UNDER THE LIMITED WARRANTY. SEE THE LIMITED
WARRANTY FOR DETAILS. IF YOU HAVE ANY QUESTIONS
REGARDING THESE APPLICATION INSTRUCTIONS, PLEASE
CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT
800-641-4691.
Information included in these application instructions was current at time of printing.To
obtain a copy of the most current version of these application instructions,visit us online
at tamko.com or call us at 800-641-4691.
TAMK00,Moisture Guard Plus@,Tam-Shield0,TAM-PRO®and Heritage®are registered
trademarks and SuperX 30 is a trademark of TAMKO Building Products,Inc.
I
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.Com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 5
JP69909