Loading...
HomeMy WebLinkAboutReview Comments ffffffM JEERINGWSM"W. PROFESSIONAL STRUCTURAL CONSULTANTS 850 NW Federal Hwy-Suite 172,Stuart,FL 34994 Voice:(772)223-9883 October 28, 2017 Mr. Ed Roseberry Plans Examiner c/o St. Lucie County Building& Code Regulation Division 2300 Virginia Ave. Fort Pierce, FL 34982 Re: Permit No. 1704-0270, 260 Nettles Blvd,Jensen Beach, FL 34957,Review Comments 4/14/2017 Dear Mr. Roseberry; I have been retained to certify the issues noted in your review dated 4/17/2017 for the above referenced site. I am providing the following report for your use. The new Hardiplank siding is installed properly per manufacturer's specifications with 8d stainless steel ring shanks over a 6 mil weatherproof barrier over existing 5/8" CDX plywood over the existing wall studs. The negative gravity load structural effects of the Hardiplank installation are non-existent. The gravity load from Hardiplank is 2.3 PSF. This is equivalent to one layer of 5/8" sheetrock and slightly more than %2" wood lap siding (2.15 PSF). The substitution of Hardiplank siding to this structural system can be made without concern to the structural integrity of this building. The Hardiplank installation at the above reference site meets or exceeds the requirements of the Florida Building Code, 2014 Edition and ASCE 7-10 and all have been approved by me. If you have any questions or concerns, or if I can be of any future service, please do not hesitate to� htty./// j%j_ES Pe ..• Stib%W �FP.$t� C:\PROJECTS\2017\17-086 260 NETTLES ISLAND\17-086 260 NETTLES ISLAND CERT:doc 1