Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEET-► i L7 , s 1 ST. LUCIE WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below —� Low Slope Application A, B, C 1= a,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,S,6,7 4 Asphaltic Shingles A, B, D t 2,4S,g.7 A, B, D, E 1,2,3,4,5,6,7 A, B, D 1,2 3.4,5,fi 7 Concrete or Clay Tile Metal Roofs Wood Shingles and ;Shakes A, B, D 1,2,4,5,6,7 Other As Applicable 1,2,g,4.5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval. !i ! Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4, Other Component of Product Approval 5, Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing only) 7. Any Required Roof Testing/Calculation Documentation Form Rooflnfofeb21 Rev Feb 16, 2021 ST. LUCIE WORKS Section A (General Information) Master Permit No. Contractors Name Collins Roofing Inc, —> Job Address Ss 0 g cas&l-De— Process No. License # CCC-058011 ROOF CATEGORY w Slope ❑ Mechanically Fastened Tile C] Mortar/Adhesive Set Tiles As phalticc Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE ❑ New roof ❑ Repair ❑ Maintenance % Reroofing ❑ Recovering ROOF SYSTEM INFORMATI 4 Low Slope Roof Area (SF)Sop Steep Sloped Roof Area (SF) 'MM—> Total (SF) MOO Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ST. LUCIE Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer. Polyglass Product Approval No FL 1654 Design Wind Pressures, From RAS 128 Or Calculations. 53 Z -53 3 -74 4 -95 8 Zone 1' one L Zone 2 Zone 3 Max Design Pressure, from the specific product approval system Deck. Type Plywood Gauge Thickness 5/8" Slope. 1-1/2 / 12 Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer. Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material, Top Insulation Layer: Top Insulation Size and Thickness Top Insulation Fastener/Bonding Material Base Sheet(s) & No. of Ply(s): Polyglass SA-V & 1 Base Sheet Fastener/Bonding Material, Self -Adhesive Ply Sheet(s)' & No. of Ply(s). Ply Sheet Fastener/Bonding Material: Top Ply: Polyglass SA-P Top Ply Fastener/Bonding Material: Self -Adhesive White Granular Surfaces Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment. Zone 1':_" oc @ Lap, # Rows— @ ; oc Zone 1:_.." oc @ Lap, # Rows — @ �" ac Zone 2:—" oc @ Lap, # Rows— ®�" oc Zone 3:—" oc @ Lap, # Rows— @ �" oc Number of Fasteners Per Insulation Board. Zone 1': Zone 1-.—Zone 2: Zone 3:. Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc. Indicate; Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. ST. LUCIE WORKS Section D (Steep Slope Roof System) Roof System Manufacturer Notice of Acceptance Number FL Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): 813 —> Zone 1„124Zone 2e:.2aZone 2nly5one 2r_l�one 3e Zane 3r- Deck Type: 518" Plywaod Type Underlayment: ' Self Adhesive Underlayment • T Y1 ?-,Ai ft S� ,_11(� Rojof,�5bpe: -- Insulation; I NIA Fire Barrier: N/A _> RidgeVe "It n7 Fastener Type &Spacing: 6 Nails PerShingle - 1 1/4" Coil N Is Adhesive Type: Brtuman Tar Type Cap Sheet NIA Mean Roall Height: 15 ft Roof Covering: Dimensional Asphault Shingles Type & Size Drip 2"x2" Galy. Steel Edge: