Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number. Owner. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Type�l432.0 sgft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1224.00 ft2 b. Frame-Wood,Adjacent R=11.0 208.00 ft2 3. Number of units,if multiple family 1 c.NIA R= ft2 4. Number of Bedrooms 3 d.NIA R= ftz 5. Is this a worst case? Yes 11.Ceiling Types (1783.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1753.00 ft' 6. Conditioned floor area above grade(ftz) 1753 b.Knee Wall(Vented) R=19.0 30.00 ftz Conditioned floor area below grade(ftz) 0 c.NIA R= ftz 7. Windows(151.4 sgft.) Description Area 12.Ducts R ft2 a. U-Factor Sgl,U=1.02 111.36 ftz a.Sup:Attic,Ret:Attic,AH;Attic 6 195 SHGC: SHGC=0.29 b. U-Factor: Sgl,U=1.11 40.00 ftz 13.Cooling systems kBtulhr Efficiency SHGC: SHGC=0.27 a.Central Unit 34.8 SEER:15.00 c. U-Factor: NIA ftz SHGC: Area Weighted Average Overhang Depth: 2.850 ft. 14.Heating systems kBtulhr Efficiency Area Weighted Average SHGC: 0.285 a.Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15.Hot water systems SHGC(AVG): NIA a.Electric Cap:40 gallons 9. Floor Types (1753.0 sqft.) Insulation Area EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features b.NIA R= ft2 None c.NIA R= ft2 16.Credits None Glass/Floor Area: 0.086 Total Proposed Modified Loads: 49.38 PASS Total Baseline Loads: 50.69 PA �7 I hereby certify that the plans and specifications covered by Review of the plans and a-gBE this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Cade. !• n„rti,, ,;-r r,,� p PREPARED BY: Before construction is completed DATE: 1-12-2021 this building will be inspected for hil compliance with Section 553.908 * ¢ I hereby certify that this building, as desi n ompliance Florida Statutes. with the Florida Energy C G'p�we OWNER/A BUILDING OFFICIAL: DA?E: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Detached FL, New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft' __ 0 1 0 2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 W 0 1 0 3 Slab-On-Grade Edge Insulatio MASTER BATH 8 ft 0 56 W __ 0 1 0 4 Slab-On-Grade Edge Insulatio M.BATH 7 ft 0 61 ft' ___ 0 1 0 5 Slab-On-Grade Edge Insulatio LAUDRY 1 It 0 36 W __ 0 1 0 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC An Edition(2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab-On-Grade Edge Insulatio BEDROOM 2 12 It 0 180 ft' ___ 0 1 0 7 Slab-On-Grade Edge Insulatio DINING/GREAT 50 R 0 588 fF __ 0 1 0 8 Slab-On-Grade Edge Insulatio KITCHEN lift 0 209 ft' ___ 0 1 0 9 Slab-On-Grade Edge Insulatio BATH 5 it 0 50 ft. __ 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 it 0 25 ft' ___ 0 1 0 11Slab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft' 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 __ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 It, Light N 0.6 No 0.9 No 0 18.4 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) MASTER BEDRO 30 Blown 224 ft' 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic(Vented) MASTER BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic(Vented) M.BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic(Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic(Vented) DINING/GREAT 30 Blown 588W 0.1 Wood 8 Under Attic(Vented) KITCHEN 30 Blown 209 ft' 0.1 Wood 9 Under Attic(Vented) BATH 30 Blown 50 ft' 0.1 Wood 10 Under Attic(Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic(Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic(Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood 13 Knee Wall(Vented) DINING/GREAT 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block-Int InsMASTER BE 4.1 16 0 8 0 128.0 ft' 0 0 0.3 0 _ 2 SW=>NE Exterior Concrete Block-Int InsMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 3 NW=>SE Exterior Concrete Block-Int InsWASTER BE 4.1 14 0 8 0 112.0 ft' 0 0 0.3 0 1/12/2021 1:15 PM EnergyGaugeC USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 4 NE=>SW Exterior Concrete Block-Int InsMASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 5 NE=>SW Exterior Concrete Block-Int Insul M.BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 6 NE=>SW Exterior Concrete Block-Int InSBIEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 -7 SW=>NE Exterior Concrete Block-Int Ins(DINING(GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.3 0 8 NW=>SE Exterior Concrete Block-Int InS01INING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.3 0 9 SW=>NE Exterior Concrete Block-Int InsulKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0 _10 NE=>SW Exterior Concrete Block-Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.3 0 _11 SE=>NW Exterior Concrete Block-Int Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 _12 SW=>NE Exterior Concrete Block-Int Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 13 NE=>SW Exterior Concrete Block-Int InsSEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0 _14 SWaNE Exterior Concrete Block-IM InsBIEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 _15 N=>S Garage Frame-Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated FOYER None .39 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => chan ed to Worst Case. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.02 0.29 Y 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>SW 5 Metal Low-E Single Yes 1.02 0.29 Y 6.9 ft2 1 ft 0 in 1 It 4 in None None 3 NE=>SW 6 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft2 1 ft 0 in 1 ft 4 in None None 4 SW=>NE 7 Metal Low-E Single Yes 1.02 0.29 Y 39.8 1`12 1 It 0 in 1 ft 4 in None None 5 NW=>SE 8 Metal Low-E Single Yes 1.11 0.27 Y 40.0 ft2 8 ft 0 in 1 ft 4 in None None 6 NE�SW 13 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1168.7 64.12 120.37 .0902 5 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Duds 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Duds 1 Central Unit/ Split Sing] SEER:15 34.8 kBtu/hr dm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPM Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft' DUCTS / —Supply— —Return— Air CFM 25 CFN 25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 195 ft- Attic 55 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:N Ceiling Fans: Conlin [rX'�Jan [rX']Feb [[JC1J Mar r Apr r[ May I[X]I Jun I[X]]Jul [�0]Aug (n Se r Oct [N Nov [H Dec Venting [ ]Jan [ ]Feb [XJ Mar Apr [ May [ }Jun [ ]Jul [ ]Aug [ ]Seep Oct Nov [XJ Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) PM 68 8 8 8 68 8 68 68 68 68 68 68 Heating(WEH) PM 68 68 68 68 8 8 8 8 8 8 8 8 MASS Mass Type Area Thickness Furniture Fraction Space Default(81bs/sq.fL 0 ft- Oft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ffl ft 0.3 WIC Defauft(8 lbs/sq-ft. ft' ft 0.3 MASTER BATH Defautt(8 Wsq.ft. ft' ft 0.3 M.BATH Default(81bs/sq.ft. ft' ft 0.3 LAUDRY Defauft(8lbs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(B lbs/sq-ft. ft' ft 0.3 DININGlGREAT R Default(8 lbs/sq.ft. IF fl 0.3 KITCHEN 1/12/2021 1:15 PM EnergyGaugeO USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(81bs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft- ft 0.3 HALL Default(S lbs/sq.ft. ft' ft 0.3 FOYER Default 8lbs/s .ft. ft' ft 0.3 BEDROOM 3 1/1212021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 6 of 6 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 a AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: cYJ Owner: Jurisdiction: _ Design Location: FL,Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceilingisoffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed, shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extenel hphinrl pining and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition,inspection of log walls shall be in accordance with the provisions of]CC-400. 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index,the more efficient the home. THE WINDSOR, FT. PIERCE, FL, 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4.1 1224.00 R' b.Frame-Wood,Adjacent R=11.0 208.00 ft 3. Number of units,if multiple family 1 c.N/A R= ft- 4. Number of Bedrooms 3 d.N/A R= ft' 11.Ceiling Type and insulation level Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1753.00 ft' 6. Conditioned Floor area(ft') 1753 b.Knee Wall(Vented) R=19.0 30.00 H' c. R= f 7. Windows" Description Area ft a. U-Factor. Sgl,U=1.02 111.36 ft' 12. Ducts,location&insulation level R a.Sup:Attic,Ret:Attic,AH:Attic 6 19595 SHGC: SHGC=0.29 b. U-Factor: Sgl,U=1.11 40.00 ft2 SHGC: SHGC=0.27 13.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft' a.Central Unit 34.8 SEER:15A0 SHGC: d. U-Factor: N/A ft' 14.Heating systems kStu/hr Efficiency SHGC: a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.285 8. Skylights Description Area 15.Hot water systems a. U-Factof(AVG): N/A ft� a.Electric Cap:40 gallons EF:0.97 SHGC(AVG): NIA b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft' Credits(Performance method) None J.N/A R= ft' c.N/A R= ft' I certify that this home has complied with the Florida Energy Efficiency Cade for Building JJJI3 gp Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed ,,,°`based on installed Code compliant features.. +... Builder Signature: Date: �D � � � iyl", a x Address of New Home: 'S k� t\RZ�d City/FL Zip: WE 3�q sa *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. --Labe(required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1 WI ightsoft® Project Summary Job: Entire House By QUICK CALCS, INC. 317 ST.LUCIE UN.,Fr..PIERCE,9-$4946 Phor :772466-6799 Fax 772466£796 Email:QUICKCALCS@40LCOM Promect Information For. WYNNE DEVELOPMENT THE W INDSOR,FT.PIERCE,FL Notes: Design Information Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21542 Btuh Structure 16420 Btuh Duds 6191 Btuh Duds 9337 Btuh Central vent(0 cm) 0 Btuh Central vent(0 cfm) 0 Btuh none Humidification 0 Btuh Slower 0 Btuh Piping 0 Btuh Equipment load 27734 Btuh Use manufacturer's data In Rate/swing multiplier 0.95 Infiltration Equipment sensible load 24470 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2495 Btuh Duds 2546 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft') 1759 17 Equipment latent load 5041 Btuh Volume(ft') 16478 16478 Airchanges/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 29511 Btuh Equiv.AVF(cfin) 104 55 Req.total capacity at0.7 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIRCONDITIONING Trade CARRIERAIRCONDITIONING Model 25HBC536XO30 Cond 25HBC536A O30 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating input Sensiblecooling 24360 Btuh Heating output 34600 Btuh @47-F Latentcooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual airflow 1160 cfin Actual airflow 1160 dm Airflowfactor 0.042 cfin/Btuh Airflowfactor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point=36 OF Backup: Input=7 kW, Output=23009 Btuh,100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrghLsotY.4 P� •�^ w^—+*-^� Rigtt-Sute0Un 2021 JaM 213:18:18 versa1201919.021 RSU08101 Pagel ...Do rtslWdgHbot HVAMWYNNE-hIEWINDSORnp Calc=M18 Frorlr!DDOrfaces:N rI-wrightsofr Right-l®Worksheet o . Entire House By. QUICK CALCS, INC. 317 ST.LUCIE LN.,Fr..PIERCE,FL 34946 Ptnre:772-466-6799 Fax 772466.6796 Emaii:QUICKCA.LCS@AOL.COM Tname ENre Hone BEDROOM E)postlwall 207.E ft ED ft height 9.4 t d 9.4 ft heakfcool dimensions 14.0 x 20.0 ft area 1753.0 ft' 280.0 1F Ty Construction U-value Or HTM Area Load Area (M Load number (BWhj22F) (BfuhM or penmefer (ft) (BWh) or perimeter (it) (BWh) Heat Cool Gros N/P/9 Heat Cool Gross N/P/S Heat Cool 6 y/ 13A-0as 0.143 n 4.00 2.55 649 596 2386 1517 66 66 263 167 II--CG 1Aclom 1270 n 35.56 34.77 15 0 533 522 0 0 0 0 4A5-2om 0.770 n 2156 19.31 38 0 815 730 0 0 0 0 W 13AAo s 0.143 ne 4.00 255 27 27 106 68 0 0 0 0 11 W 13A4= 0.143 a 4A0 2.55 141 100 400 255 0 0 0 0 ---GD to-clam 1270 a 3556 87.06 20 1 711 1741 0 0 0 0 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W 13A4ocs 0.143 se 4.00 2.55 27 27 106 68 0 0 0 0 y 13AAo 0.1 s 4.00 255 536 530 2121 1349 188 188 753 479 L-G 1Ac1an 1270 s 3556 34.77 6 6 213 209 0 0 0 0 yy// 134-4ors 0.143 w 4.00 2,55 320 255 1022 w 132 108 432 275 'r--G 1Aoiom 127 w 3556 54M 12 1 415 636 12 1 415 636 IL--GG 1Ac1om 1270 w 3556 64.53 12 1 427 654 12 1 427 654 445-2om 0.770 w 21.56 45.63 41 2 880 1862 0 0 0 0 P 12C-Nw O.091 - 255 128 254 254 647 326 0 0 0 0 C 16A-30md 0.032 0.90 2.32 1753 1753 1571 4067 280 280 251 650 F 22A-WI 0.989 27.69 0.00 1753 208 5748 0 280 41 1135 0 6 c)AED emursion 397 488 Envelope lossgain 1 183311 15285 3676 3349 12 a) Infiltration 3211 905 729 205 b) Room Ventlation 0 0 0 0 13 lntemal gain Ooalpants@ 230 1 230 0 0 Applonrns/other 0 0 Subtotal(lines6to13) 21542 16420 4405 3554 LeseWemalload 0 0 0 0 bulam 0 0451/. 0Lesstransfer 0 00 0 Redlstri 0 14 Subtotal 21542 164204405 3554 loads 15 Duct 29% 57% 6191 9337 29% 1266 2021 Total room load 1 27734 25757 5671 5575 Airrequired(dm) 1160 116D 237 251 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed._ vrrAM rll-71 o7Y" 2021-Jan1213: e I RigttSule®Unversa1201919.021 RSU08101 Page ...Dod itstWngtwflHUAQWYNNE-THEWINDSORnp Calc=MJS Fror¢Doorfams:N icir vvrightsow Right-®Worksheet Date: Entire House BY By. QUICK CALCS, INC. 317 ST.LUCIE LN.,F..PIERCE,FL 34946 Prore:772-466-6799 Fac 772+166-6796 Email:OUICKCALCS@AOL.00M 1 Room name WIC MASTER BATH 2 EpoSedvsll 0 It 9.0 It 3 Room height 9.4 ft he-acoa 9.4 ft haaecDol 4 Room dimensons 7.0 x 9.0 ft 7.0 x 9.0 ft 5 Room area 63.0 T 63.0 iF Ty Construction U-value Or HTM Area (T) Load Area (� Load number (Bluh4F-°F) (BNh4f0 or perimeter (ft) (Bluh) or perimeter (ft) (Buh) Hea[ Cool Gross N/P/S Heat Cool Gros NIPS Heat Cool 6 V�1 13A-4ocs 0.143 n 4.00 2S5 0 0 0 0 0 0 0 0 I-G 1A-cian 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 L-G 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 W 13A4ar 0.143 ne 4.00 2S5 0 0 0 0 0 0 0 0 17 y/ 13A-0ws 0.143 a 4A0 2.55 0 0 0 0 0 0 0 0 ----GD 1Ao1om 1270 a 3556 87.06 0 0 0 0 0 0 0 0 IL 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 1M-4= 0.143 se 4A0 255 0 0 0 0 0 0 0 0 Uy 13A4= 0.143 s 4.00255 0 0 0 0 85 85 339 216 L--G 1A-dom 1270 s 35.66 34.77 0 0 0 0 0 0 0 0 13A-4= 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 tAclam 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 to-c1om 1270 w 3556 54.63 0 0 0 0 0 0 0 0 4A5-20m 0.770 w 2t 56 45.63 0 0 0 0 0 0 0 0 P 12C-0sw 0.091 - 2.55 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 090 2.32 63 63 56 146 63 63 56 146 F 22A-tpI 0.989 27.69 0.00 63 0 0 0 63 9 249 0 6 c)AED ex ursim -10 -28 Envelope losstgain 56 136 644 334 12 a) Infiltration 0 0 160 45 b) Roomeentilation 0 0 0 0 13 Inkmal gains O=pan5@ 230 0 0 0 0 Apploicesrolher 0 0 Subtofal(Ilnes6to 13) 56 136 804 379 Lesse)laml load 0 0 0 0 Le tansfer 0 0 0 0 RedLstitxfion 0 0 0 0 14 SuMotal 56 136 804 379 16 Dudloads 29% 57% 16 77 29% 57% 231 216 Total rcom load 73 214 1036 595 Air required(dm) 3 10 43 27 Calculabons approved bVACCAto meet all requirements of Manual J 8th Ed. , �9tiLy�.. 2021-Jarr1213:18:18 e9 PogttSuh4Uriversa1201919.021 RSUO8101 Page 2 ...CaarrertslW69�ftHVAaWYNNE-THEWINDSORnp COI.=MI6 Frond Doortame N t i vurightsW Right4@ Worksheet Job Entire House Date: By. QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE.FL 34946 Phone:772-466-6799 Faz 772466.6796 Emil:OUICKCALCS@AOL.COM 1 Room name IABATH KITCHEN 2 Esposfdvall 8D ft 8.0 It 3 Room heGht 94 It hea=l 9.4 ft heaVmol 4 Room dimensions 7.0 x 8.0 ft 1.0 x 172.0 It 5 Room area 56.0 IF 172D fe Ty Consmxtion U-value Or HTM Area OF) Load Area (fe) Load number (Btuh/V--7) (BIuh" or perimeter (ft) (BUh) or perimeter (ft) (Btuh) Heat Cool Gross NIPS Heat Cool Gros; N/P/S Heat Cool 6 4t/ 13q�; 0.143 n 4.00 255 0 0 0 0 0 0 0 0 {L.-_- to-clom 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 21.56 1931 0 0 0 0 0 0 0 0 W 13A4ocs 0.143 ne 4.00 255 0 0 0 0 0 0 0 0 11 13A4oas 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1270 a 35b6 87.06 0 0 0 0 0 0 0 0 11D0 0390 a 1092 11.31 0 0 0 0 0 0 0 0 w 13A4o s 0.143 s: 4.00 2.55 0 0 0 0 0 0 0 0 13A4ocs 0.143 a 4A0 255 76 69 277 176 0 0 0 0 t-G 1Ac1om 1270 a 35.% 34.77 6 6 213 209 0 0 0 0 la44cs 0.143 w 4.00 2S5 0 0 0 0 0 0 0 0 tAcIom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 1Ac1cm 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 4A5-20m 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P 12C-Ow DA91 2.55 128 0 0 0 0 75 75 192 96 C 164-30md 0.032 - 0.90 2.32 56 56 50 130 172 172 154 399 F 2244pl 0.989 - 27.69 0.00 56 8 222 0 172 8 222 0 6 c)AE D rsion -38 -34 Envelope loss/gam 762 4T7 567 462 12 a) Infiltration 142 40 0 0 b) Rcomventilation 0 0 0 0 13 Intemalgains Omipants@ 230 0 0 0 0 Appliannestother 0 0 Subtot3l(lins;6h113) 904 517 567 462 Lesextemalload 0 0 0 0 Lestrans(er 0 0 0 0 Redishibution 0 0 0 0 14 Subtotal 904 517 567 462 15 Duct loads 29% 57% 260 294 29%. 57% 163 263 Total room load 1164 811 730 725 fJrrequired(dm) 49 37 31 33 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrigMlSOTC' 2021-Jan.1213:18:18 ^^ RigitSULOUnversal 201919.021 RSU08101 Page -.DoamertAWrigO-roft HUAOWVNNE-THEWINDSORnp Calc=Ml8 Front Deorfaws:N -tAi-wrightrofr Right-JO Worksheet Job` Entire House Date: By. QUICK CALCS, INC. 317 ST.LUCIE LN.,Fr..PIERCE,R 34946 Prone:712-466-6799 F.712466-6796 Email:OUICKCALCS AOL.COM 1 Room name BATH BEOROOM2 2 E>prlsedwall 6.0 It 42.6 It 3 Room height 9.4 It heaV000l 9.4 It heaV000l 4 Room dimensions 9.0 x 5.0 It 1.0 x 204.0 ft 5 Room area 45.0 1F 204A ft' Ty Coneru[4on U-value Or HTM Area (ft) Load Area If?) Load number (BWhflF-7) (BV1w or penmeter (ft) (Btuh) or perimeter (ft) (BWh) Heat Cool Gross NiP)S Heat Cool Gros NNS Heat Cool 6 V�1 13k4ots 0.143 n 4.00 2.55 47 47 188 121) 132 132 527 335 F---G 1Actcm 1270 n 3556 34.77 0 0 0 0 0 0 0 0 �--G 4A5-2wn 0770 n 2156 1931 0 0 0 0 0 0 0 0 w� 13A4ors 0.143 ne 4.DD 2.55 0 0 0 0 2727 106 68 V 11 � -D 13A-4ors 0.143 a 4.00 2S5 0 0 0 0 8.5 65 259 164 IA-dom 1270 a 3556 87.06 0 0 0 0 20 1 711 1741 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A4ors 0.143 se 4.00 2.55 0 0 0 0 27 27 106 68 14/ 13A-4ous 0.143 s 4.00 2.55 0 0 0 0 132 132 527 335 I-G to-dom 1270 s 3556 3477 0 0 0 0 0 0 0 0 13A-4ors 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 w 3556 5453 0 0 0 0 0 0 0 0 G 1Aclom - 1270 w 35.56 64.53 0 0 0 0 0 0 0 0 4A5-2om 0.M w 2156 45.63 0 0 0 0 0 0 0 0 P 12c-om OA91 - 2.55 129 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 020 Z32 45 45 40 104 204 204 183 473 F 22A-tp1 0.989 - 27.69 0.00 45 5 138 0 204 43 1179 0 6 c)AED exwrsion -17 -99 Envelope loss/gain 1 367 207 1 3599 3085 12 a) Infiltabon 89 25 758 214 b) RoomveMla6on 0 0 0 0 13 Internal0= O-pants@ 230 0 0 0 0 Appliwoes(other 0 0 SubllNal(lines6to 13) 456 232 4357 3299 Less e)lemal load 0 0 0 0 Lesstansfer 0 0 0 0 Redishbufion 0 0 0 0 14 Subtotal 456 232 1252 1876 15 Ductloads 29% 57% 131 132 29% 57% 1252 1876 Total room load 587 364 5609 5175 Air required(dm) 25 16 235 233 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. wrl9hMal'[' 2021Jar�1213.18.18 R1grtSulea Uri.e 1201919.021RSUDal01 Page ...Doomerts\WrigWt ftHUAC\WYNNE-THEWINDSORnp Calc=WS Fror¢DoorfaceSN wdghtsoftr Right-M Worksheet J«1: Entire House Date: QUICK CALCS, INC. By. 317 ST.LUCIE LN,FL PIERCE,FL 34946 Phore:772-466.6799 Fax T72-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name ENTRY LAUNDRY R 18A ft 13.0 ft Room height 9.4 It heatbool 9.4 It 3 R heatlwol 4 Room dimensions 1.0 x 92.0 ft 7.0 x 6.0 It 5 Room area 92.0 IF 42.0 iF Ty I Construction U-value Or HTM Area Load (fF) Load number (BWh/(F--°F) (BWhAF) or perimeter (ft) (BNh) oorperimeter (ft) Efuh) Hea[ Cool Gross N/Pr. Heat C401 Gras N/P/S Heat Cool 6 Yr/ 13A-4ors 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 11--GG 1Ac1om 1270 n 3556 34.77 0 0 0 0 0 0 0 0 4A5-2om O.T70 n 2156 1931 0 0 0 0 0 0 0 0 W 13A-4ors 0.143 ne 4.00 255 0 0 0 0 0 0 0 0 11 13A-4= 0.143 a 4.00 2.55 56 35 142 90 0 0 0 0 Ac1om 1270 a 35.56 87.06 0 0 0 0 0 0 0 0 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W 13A-4= 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 13A4as 0.143 s 4.00 2.55 0 0 0 0 56 56 226 144 1Ac1om 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A4o 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 w 3556 54.53 0 0 0 0 0 0 0 0 tActom 1270 w 3556 5453 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 2156 46.63 0 0 0 0 0 0 0 0 P 12C-0w+ 0.091 255 128 113 113 287 145 66 66 168 84 C 16A30md 0.032 - 0.90 2.32 92 92 82 213 42 42 38 97 F 22A-tpI 0.989 - 27.69 ODD 92 18 498 0 42 13 360 0 6 c)AED e=rson -09 24 Ernelope losfgain 1239 637 791 301 12 a) Infiltration 107 30 107 30 b) Roomvenfilation 0 0 0 0 13 htemal gaire: Oaupanls@ 230 0 0 0 0 Applianw.4other 0 0 Subtotal(lines6to 13) 1346 667 898 331 Les exemal load 0 0 0 0 Less transfer 0 0 0 0 Redistibuton 0 0 0 0 14 Subtotal 1346 667 898 331 15 Dudloads 299% 57% 387 379 29% 57% 258 188 Total room load 1733 1047 1156 520 Airrequired(dm) 72 47 48 23 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wWxoft s - 2021-JarF1213:18:18 Right-Sute@Uriverm1201919.021 RSU08101-.DDo rts\Wngtboft HUADWYNNE-THEWINDSORnp CaIc=MJ8 Frort Doorfacer N Pag e5 wrightsoR- Right-l)Worksheet Jab: Entire House Date: QUICK CALCS, INC. BY 317 ST.LUCIE LN,Fr.PIERCE,FL 34946 Phore:772-466-6799 Fax 772-466-6796 Email:QUICKC4LCS@4OL.COM 1 Room name GREATAYNiNG Room7 2 Fposed vrall 50.0 It 130 ft 3 Room height 9.4 1t heaV=l 9.4 It heaf(=l 4 Room dimensions 1.0 x 567.0 It 13.0 x 130 ft 5 Room area 567.0 IF 16910 R Ty Construction U-value Or HTM Area Area (1t=) Load number (BIUMF 9 (BWhAF) or perimeter (ft) (BMh) or perimeter (ft) (BWh) Hea[ Cool Gros N/P/S Heat Cool Gros NP5 Heat Cool 6 V/ 13A4= 0.143 n 4.00 2.55 282 244 978 622 122 107 429 273 I�-CC 1Ac1om 1270 n 3656 34.77 0 0 0 0 15 0 533 522 4A5-2om 0.770 n 2156 1931 38 0 815 730 0 0 0 0 w 13A4as 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 13A4= 0.143 a 4.00 2.55 0 0 0 D 0 0 0 0 1Ac1om 1270 a 35.56 87.06 0 0 0 0 0 0 0 0 III--DDD 11D0 0.3W a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A4= 0.143 se 4.00 2.55 0 0 0 0 0 0 D 0 13A4= 0.143 s 4.00 255 0 0 0 0 0 0 0 0 t-C 1Aciom 1270 s 35M 34.77 0 0 0 0 0 0 0 0 13A4os 0.143 w 4.00 2.55 188 147 589 375 0 0 0 0 1A-clom 1270 w 3556 5453 0 0 0 0 0 0 0 0 tActom 1270 w 35.56 5453 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 41 2 880 1862 0 0 0 0 P 12C.Ow 0A91 2,55 128 0 0 0 0 0 0 0 0 C 16AJOmd 0.032 - 020 2.32 567 567 508 1315 169 169 151 392 F 22A-tpl 0989 - 27.69 0.00 567 50 1385 0 169 13 360 0 6 c)AED exarrsion 307 -100 Envelope loss/gain 5154 5210 1474 1086 12 a) Infiltration 889 251 231 65 b) Room ventilation D 0 0 0 13 Intemal gal Omlpants@ 230 0 0 1 230 Applianos/other 01 0 Subtotal(lines 6 to 13) 6043 5461 1705 1381 Lesexemalload 0 0 Lestransfer 0 0 0 0 Redistribution 0 0 0 0 0 0 14 Subtotal 6043 5461 1705 1381 15 Duriloads 29% 57% 1737 3105 29% 67016 490 785 Total room load 7780 85% 2195 2167 Airreauired(Um) 325 386 92 98 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed wr�9►+tvoTe- RgttSute�J UrivErsa1201919.021 RSU08101 2021-Jao-121 Page 6 .9C�R -.Doamer6lWrignmft HUADWYNNE-THEWINDSORAp Calc=MIB Fr01QDoOrfares:N age -� wrightsoft® Duct System Summary o te1 Entire House By. QUICK CALCS, INC. 317 ST.LUCIE UN,Fr.PIERCE,FL 34946 PInre:772-466-6799 Fac 772A66-6796 Email:QUICKCALCS@AOL.COM Project • • For. WYNNE DEVELOPMENT THE W INDSOR,FT.PIERCE,FL Heating Cooling 6demal static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0 in H2O Supply/return available pressure 0.000/0.000 in H2O 0.000/0.000 in H2O Lowestfriction rate 0 ini10011 0 in(10Oft Actual airflow 1160 cfm 1160 cim Total effective length(TEL) 0 ft SupplyDetail Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Bluh) (Cfm) (Cfm) FR (In) (in) Mat Ln(it) Ln(ft) Trunk BATH. h 364 25 16 0 0 Ox 0 ShMt 0 0 BEDROOM C 2788 119 126 0 0 Ox0 ShMt 0 0 BEDROOM2 h 2587 117 117 0 0 0x0 ShMt 0 0 BEDROOM2-A h 2587 117 117 0 0 Ox0 ShMt 0 0 BEOROOM-A C 2788 119 126 0 0 Ox0 ShMt 0 0 ENTRY h 1047 72 47 0 0 Ox0 ShMt 0 0 GREATmwING C 2855 108 129 0 0 Ox0 ShMt 0 0 GREAVOINING-A C 2855 108 129 0 0 OX 0 ShMt 0 0 GREAT0NING-8 c 2855 108 129 0 0 Ox0 ShMt 0 0 KITCHEN C 725 31 33 0 0 OxO ShMt 0 0 LAUNDRY h 520 48 23 0 0 Ox 0 ShMt 0 0 M.BATH h 811 49 37 0 0 Ox 0 ShMt 0 0 MASTERSATH h 595 43 27 0 0 Ox0 ShMt 0 0 Room? C 2167 92 98 0 0 Ox 0 ShMt 0 0 wIc C 214 3 10 0 0 Ox0 ShMt 0 0 Return Branch Detail Table Hlg Clg TEL Design Veloc Dam H x W SturllJoist Duct Name Size(in (drn (Cfm) (ft) FR (fpm) (In) (in) Opening(in) Mat Trunk rb1 Ox 0 1 1160 1160 0 1 0 0 0 Ox 0 ShMt Ai- wrightsoft' 2021-J 1213:18:19 �� ....-, ..m...,�..„ RigH-SUbaOUriwrsa1201919.021RSU08101 Paget ...Dom r&Wdgttsoft HVAC,WYNNE-THE WINDSOR.np Calc=W8 PmMDoorfaws:N