Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutAPPROVED ENERGY CALCS & MANUAL JFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE W INDSOR IMPACT
Street: THE WINDSOR
City, State, Zip: FT. PIERCE, FL,
Owner.
Design Location: FL, Fort Pierce
Builder Name: WYNNE DEVELOPMENT
Permit Office: ST. LUCIE COUNTY
Permit Number:
Jurisdiction:
County: St Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type�1432.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1224.00 ft2
3. Number of units, if multiple family i
b. Frame - Wood, Adjacent
c NIA
R=11.0 208.00 ft2
R= ft2
4. Number of Bedrooms 3
d. WA
R= ft2
5. Is this a worst case? Yes
11. Ceiling Types (1783.0 sgft.)
Insulation Area
a. Linder Attic (Vented)
R=30.0 1753.00 ft2
6. Conditioned floor area above grade (ft2) 1753
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft2
7. Windows(151.4 sgft.) Description Area
12. Ducts
R ft2
a. U-Factor. 5g1, U=1.02 111.36 ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 195
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft2
13. Cooling systems
kStulhr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: NIA ft2
SHGC:
Area Weighted Average Overhang Depth: 2.85C ft.
14. Heating systems
kBtulhr Efficiency
Area Weighted Average SHGC: 0.285
a- Electric Heat Pump
34.8 HSPF:8.50
8, Skylights Area
c. U-Factor:(AVG) NIA ft2
15. Hot water systems
SHGC(AVG): NIA
9. Floor Types (1753.0 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2
b. Conservation features
EF: 0.970
b. NIA R= ft2
None
c. NIA R= ft2
t 16. Credits
None
Glass/Floor Area. 0.086 Total Proposed Modified Loads: 49,38
PASS
Total Baseline
Loads: 50.Fi9
I hereby certify that the plans and specifications covered by
Review of the plans and
S�
this calculation are in compliance with the Florida Energy
specifications covered by this
0I-FaE
Y' ;
Code.
calculation indicates compliance
s�.
with the Florida EnergyCode.
PREPARED BY:
Before construction is completed
4
w
DATE: 1-12-2021
this building will be inspected for
,,•�'l�1��
compliance with Section 553.908
I hereby certify that this building, as design ampliance
Florida Statutes.
, ¢
with the Florida Energy C'�;
WF,
OWNERIA
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure
qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection
Checklist in accordance with R402.4.1.1
and this project requires an
envelope leakage test report with envelope leakage no greater
than 5.00 ACH50 (R402.4.1.2).
1/12/2021 1:15 PM EnergyGaugee USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE WINDSOR IMP Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1763
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180
Street
THE WINDSOR
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Detached
FL,
New/Ewsbng: New (From Plans)
Comment:
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1753 14024
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 MASTER BEDROO
224 1792 No
0
1
1
Yes
Yes
Yes
2 WIC
63 504 No
0
1
No
Yes
Yes
3 MASTER BATH
56 448 No
0
1
Yes
Yes
Yes
4 M. BATH
61 488 No
0
1
Yes
Yes
Yes
5 LAUDRY
36 288 No
0
1
No
Yes
Yes
6 BEDROOM 2
180 1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREATR
588 4704 No
2
1
Yes
Yes
Yes
8 KITCHEN
209 1672 Yes
0
1
Yes
Yes
Yes
9 BATH
5o 400 No
0
1
Yes
Yes
Yes
10 HALL
25 200 No
0
1
No
Yes
Yes
11 FOYER
92 736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3
169 1352 No
0
1
1
Yes
Yes
Yes
FLOORS
it Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
MASTER BEDRO 37 It 0
224 ft-
_
0 1
0
_ 2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ft'
_
0 1
0
3 Slab -On -Grade Edge Insulatio
MASTER BATH . 8 ft 0
56 ft'
—
0 1
0
4SIab-On-Grade Edge Insulatio
M. BATH 7 ft 0
61 ft=
-_-
0 1
0
5 Slab -On -Grade Edge Insulatio
LAUDRY 1 ft 0
36 ft=
__
0 1
0
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST RFP[ART
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
6SIab-On-Grade Edge Insulatio
BEDROOM 2 12 ft
0
180 ft2
—
0 1
0
7 Slab -On -Grade Edge Insulatio
DINING/GREAT 50 ft
0
588 ft-
_
0 1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN lift
0
209 ft2
__
0 1
0
9 Slab -On -Grade Edge Insulatio
BATH 5 ft
0
50 ft2
_
0 1
0
10Slab-On-Grade Edge Insulatio
HALL 1 ft
0
25 ft2
0 1
0
11SIab-On-Grade Edge Insulatio
FOYER 9It
0
92 ft2
_
0 1
0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 1411
0
169 ft2
_
0 1
0
ROOF
_ /
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
1/
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Metal 1847 ft2
0 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Fmc
Truss Type
1 Under Attic (Vented)
MASTER BEDRO
30
Blown
224 ft2
0.1
Wood
2 Under Attic(Vented)
WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 ft2
0.1
Wood
6 Under Attic (Vented)
BEDROOM 2
30
Blown
180 ft2
0.1
Wood
7 Under Attic (Vented)
DINING/GREAT
30
Blown
588 ft2
0.1
Wood
8 Under Attic (Vented)
KITCHEN
30
Blown
209ft-
.1
Wood
9 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
10 Under Attic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11 Under Attic(Vented)
FOYER
30
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3
30
Blown
169 ft2
0.1
Wood
13 Knee Wall (Vented)
DINING/GREAT
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent
Space Cavity Width
Height
Sheathing Framing Solar Below
_ 1
NE=>SW Exterior Concrete Block
- Int InsOIASTER BE 4.1 16
0 8
0
128.0 ft2
0 0
0.3
0
2
SW=>NE Exterior Concrete Block
- Int InsWASTER BE 4.1
7
0 8
0
56.0 ft2
0 0
0.3
0
3
NW=>SE Exterior Concrete Block
- Int InsUASTER BE 4.1
14
0 8
0
112.0 112
0 0
0.3
0
1 /12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INP11T RI IMMGRY rW;:r lI ICT RIPOnMT
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing
Solar Below
4 NE=>SW Exterior Concrete Block - Int InsUASTER BA 4.1 8
0
8 0
64.0 ft2
0
0
0.3 0
-5 NE=>SW Exterior Concrete Block - Int Insul M. BATH 4.1 7
0
8 0
56.0 ft2
0
0
0.3 0
6 NE=>SW Exterior Concrete Block - Int InsBEDROOM 2 4.1 12
0
8 0
96.0 ft2
0
0
0.3 0
7 SW=>NE Exterior Concrete Block - Int InsGINING/GRE 4.1 30
0
8 0
240.0 ft2
0
0
0.3 0
8 NW=>SE Exterior Concrete Block - Int InsMINING(GRE 4.1 20
0
8 0
160.0 ft2
0
0
0.3 0
9 SW=>NE Exterior Concrete Block - Int InsuIKITCHEN 4.1 11
0
8 0
88.0 ft2
0
0
0.3 0
_10 NE=>SW Exterior Concrete Block- Int Insul BATH 4.1 5
0
8 0
40.0 ft2
0
0
0.3 0
11 SE=>NW Exterior Concrete Block - Int Insul FOYER 4.1 8
0
8 0
64.0 ft-
0
0.3 0
12 SW=>NE Exterior Concrete Block- Int Insul FOYER 4.1 1
0
8 0
8.0 ft2
0
0
0.3 0
13 NE=>SW Exterior Concrete Block - Int InstiEDROOM 3 4.1 13
0
8 0
104.0 ft2
0
0
0.3 0
14 SW=>NE Exterior Concrete Block - Int InSBEDROOM 3 4.1 1
0
8 0
8.0 ft2
0
0
0.3 0
_15 N=>S Garage Frame - Wood BEDROOM 3 11 26
8
208.0 ft2
0.23
0.3 0
DOORS
Omt Door Type Space Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>NW Insulated FOYER None
.39
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/ Wall
Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 NW�SE 3 Metal Low-E Single Yes 1.02 0.29
Y
32.4 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds Exterior 5
2 NE=>SW 5 Metal Low-E Single Yes 1.02 0.29
Y
6.9 ft2
1 ft 0 in
1 ft 4 in
None
None
3 NE=>SW 6 Metal Low-E Single Yes 1.02 0.29
Y
162 ft2
1 ft 0 in
1 ft 4 in
None
None
4 SW=>NE 7 Metal Low-E Single Yes 1.02 0.29
Y
39.8 ft2
1 ft 0 in
1 ft 4 in
None
None
5 NW=>SE 8 Metal Low-E Single Yes 1.11 0.27
Y
40.0 ft2
8 ft 0 in
1 ft 4 in
None
None
6 NE=>SW 13 Metal Low-E Single Yes 1.02 029
Y
16.2 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wail Insulation
1 806 ft2 806 ft2 26 ft
8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000254 1168.7 64.12
120.37
.0902
5
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 34.8 kBtu/hr chm 0.85 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector
Model
# Area Volume
FEF
None None
ft2
DUCTS
/ — Supply—
— Return--
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 195 ft.
Attic
55 ft2 Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programablee
Ceiling Fans:
1Thermostaf[t:7]N
Heating EX1 Jan IJt1 Feb
f ]1
tX] Mar
[ ]
L J Apr JIM
(7(�
May Jun [ 1 Jul
�0
[ t Aug
D0
[ ] Sep
]
L 1 Oct Nov
OctNov
Dec
Venting [ ]j Jan [[ ]j Feb
L(�a77 Mar
lXl
Jun I 1 Jul
I 1 Aug
I 1 Sep
LXl X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9 10 11
12
Cooling(WD) AM
PM
78
78
78 78
78 78
78 78 78
78 78 78
78
78
78 78 78
78
78
78
78 78 78
78
Cooling (WEH) AM
PM
78
78
78 78
78 78
78 78 78
78 78
78
78
78 78 78
78
78
78
78
78 78 78
78
Heating(WD) AM
PM
68
68
68 68
68 68
68 68 68
68 68
68
68
68 68 68
68
68
68
68
68 68 68
68
Heating (WEH) AM
PM
68
68 68
68 68 68
68
68
68 68 68
68
68
68 68
68 68 68
68
68
68 68 68
68
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8 lbs/sq.ft.
ft2
ft
0.3
MASTER BATH
Defauft(81bs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUDRY
Default(81bs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
DINING/GREAT R
Default(8 lbs/sq.ft.
ft,
ft
0.3
KITCHEN
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area Thickness Furniture Fraction
Space
Default(8 lbs/sq.ft.
ft2 ft 0.3
BATH
Default(8 lbs/sq.ft.
ft2 it 0.3
HALL
Default(8 lbs/sq.ft.
ft2 It 0.3
FOYER
Default(8 lbs/sq.ft-
ft2 it 0.3
BEDROOM 3
1/12/2021 1:15 PM EnergyGauge@ USA 7.0.00 - RaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number.
x
Owner: Jurisdiction:
w
Design Location: FL, Fort Pierce
Z:
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air banner in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
Knee walls shall be sealed.
with a material having a thermal resistance of R-3
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
(including
The air barrier shall be installed at any exposed edge of
insulation.
Floor framing cavity insulation shall be installed to
above -garage
maintain permanent contact with the underside of
and cantilevered
9 b' subfloor decking, or floorframing cavity Insulation
floors)
shall be permitted to be in contact with the top side
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace wall
.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
on exterior
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box oi
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a In additinn ineneMinn
of Inn ,unlle cbell Fe :. .. ...d........ ..
• '-,------� •••.••.. ..••�•• �. u•iuu, uu„Vc vvlu, u,c IJI V VIJIVIIJ VI Ilili-4UU.
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (W)
7. Windows*
Description
a. U-Factor:
S91, U=1.02
SHGC:
SHGC=0.29
b. U-Factor.
Sgl, U=1.11
SHGC:
SHGC=0.27
c. U-Factor.
N/A
SHGC:
d. U-Factor.
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights
Description
a. U-FactogAVG):
N/A
SHGC(AVG):
N/A
THE WINDSOR, FT. PIERCE, FL,
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1224.00 it-
b. Frame - Wood, Adjacent
R=11.0
208.00 ft'
1
c. N/A
R=
ft-
3
d. WA
R=
ft
Yes
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1753.00 ft
1753
b. Knee Wall (Vented)
R=19.0
30.00 ttz
Area
c. N/A
R=
ft'
111.36 ft'
12. Ducts, location & insulation level
R ft'
a. Sup: Attic, Ret: Attic, AH: Attic
6 195
40.00 ft'
13. Cooling systems
kBtu/hr
Efficiency
ft'
a. Central Unit
34.8 SEER15.00
ft'
2.850 ft.
0.285
Area
ft'
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft'
b. N/A R= ft'
c. WA R= ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. -
Builder Signature:- Date:
Address of New Home: �3 q City/FL Zip:
14. Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
kBtu/hr Efficiency
34.8 HSPF:8.50
Cap: 40 gallons
EF: 0.97
None
'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, Contact the Florida Building Commission's support staff.
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
wrigh#soft° Project Summary ate:
Entire House By.
QUICK CALCS, INC.
317 ST. LUCIE LN.,FT.PIERCE, FL 34946 Plore: 772-466-6799 F. T2-466-6796 Emil: QUICKC4LCS@AOL.COM
Project Information
For. WYNNE DEVELOPMENT
THE W INDSOR, FT. PIERCE, FL
Notes:
Design Information
Fort Fierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outsidedb 42
OF
Outsidedb
90
OF
Insidedb 70
OF
Insidedb
75
OF
Design TD 28
OF
Design TD
15
OF
Daily range
L
Relative humidity
50
%
Moisture difference
61
gr4b
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 21542
Btuh
Structure
16420
Btuh
Ducts 6191
Btuh
Duds
9337
Btuh
Central vent (0 cfin) 0
Btuh
Central vent (0 cfm)
0
Btuh
none
(none)
Humidification 0
Btuh
Blower
0
Btuh
Piping 0
Btuh
Equipment load 27734
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
24470
Btuh
Method Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
2495
Btuh
Ducts
2546
Btuh
Central vent (0 cfm)
0
Btuh
Heatingg
Area(ft-)
Coolingg
(none)
1753
1753
Equipment latent load
5041
Btuh
Volume (fta) 16478
16478
Airchanges/hour 0.38
0.20
Equipment Total Load (Sen+Lat)
29511
Btuh
Equiv.AVF(cfrn) 104
55
Req. totalcapacity at0.70SHR
2.9
ton
Heating Equipment Summary
Cooling Equipment Summary
Make Carrier
Make Carrier
Trade CARRIERAIR CONDITIONING
Trade CARRIERAIR CONDITIONING
Model 25HBC536XO30
Cond 25HBC53WO30
AHRI ref 7914585
Coil FX4DN(B,F)037
AHRI ref 7914585
Efficiency 8.5 HSPF
Efficiency 12.0 EER,15
SEER
Heating input
Sensible cooling
24360
Btuh
Heating output 34600
Stun @ 47°F
Latentcooling
10440
Btuh
Temperature rise 27
OF
Total cooling
34800
Btuh
Actual air flow 1160
cfm
Actual airflow
1160
clim
Air flow factor 0.042
cfm/Btuh
Airflowfador
0.045
dm/Btuh
Static pressure 0
in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.84
Capacity balance point = 36 OF
Backup:
Input=7 kW, Output=23009 Btuh, 100AFUE
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wrighrsoft' 2021-Jarv1213:18:18
.QCCA RigN-Sutce@U`ivemI201919.021 RSU08101 Pagel
...Do rls\WngtLsoftFNAC1WYNNE-THEWINDSORnp Calc=MJ8 FrortDoorfaces:IN
wrightsofr Right-M Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE UN., Fr. PIERCE, FL 34W Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKC4LCS@AOL.COM
1
Room name
Enfire House
BEDROOM
2
Evosedwall
207.6 it
41.0 ft
3
Room height
9A ft d
9.4 ft hea%ol
4
Room dimensions
74.0 x 20.0 It
5
Room area
17530 ft'
280A fl'
Ty
Construction
U-value
Or
HTM
Area
Load
Area
Load
number
I
(BWh/ft�°�
(BNhW)
or penm�r (ft)
(B1uh)
or perimeter (ft)
(Binh)
Heat
Cool
Gros
N/P/S
Heat
Cool
Gros
N/P,S
Heat
Cool
6
Y/
13A-4=
0.143
n
4.00
2.55
649
596
2386
1517
fib
66
263
167
{L—GC
1Ac1om
1270
n
35.56
34.77
15
0 533
522
0
0 0
0
4A5-20m
0.770
n
2156
1931
38
0 815
730
0
0 0
0
W
13A-4ocs
0.143
ne
4.00
2.55
27
27
106
68
0
0 0
0
11
4)/
13A-4=
0.143
a
4A0
255
141
100
400
255
0
0 0
0
IL ---DC
1Aa1om
1270
a
35.56
$7.06
20
1
711
1741
0
0 0
0
1100
0.390
a
10.92
11.31
21
21
229
238
0
0 0
0
W
13A-4os
0.143
se
4.00
255
27
27
106
68
0
0 0
0
13A4a -
0.143
s
4.00
2-55
536
53C
2121
1349
188
188
753
479
1A,1om
1270
s
3556
34.77
6
6
213
209
0
0
0
0
13A4ocs
0.143
w
4.00
2.55
320
255
1022
649
132
108
432
275
1Aclom
1270
w
3556
54.53
12
1
415
636
12
1
415
636
1Aclom
1270
w
3556
54.53
12
1
427
654
12
1
427
654
4A5-2om
0.770
w
21.56
45.63
41
2
880
1862
0
0
0
0
P
12C4)w
0.091
2.55
128
254
254
647
326
0
0
0
0
C
16A30md
0.032
-
0.90
2.32
1753
1753
1571
4067
280
280
251
650
F
22A-tpl
0.989
-
27.69
0.00
1753
208
5748
0
280
41
1135
0
6
c)AEDe m.on
397
488
Envelope loss/gain
18331
15285
3676
3349
12
a) Indiltiation
3211
905
729
205
b) Roomventilation
0
0
0
0
13
Internal gains Omrpants@ 230
1
230
0
0
Applianoas(other
0
0
Sub411al(linss61o13)
21542
16420
4405
3554
Les ssoemalload
0
0
0
0
Lestransfer
0
0
0
0
Redislnbuton
0
0
0
14
Subtotal
21542
16420
4400
E
3554
15
Dud loads
29%
57%
6191
9337
29%
5]%
1266
2021
Total room load
27734
25757
5671
5575
Air required(cfm)
1160
1160
97
2s1
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
-P}f wrlgMtsolt- 2021-Jan1213:18:18
PogltSdte(DUdveml 20l9 l9.021 RSU08101 Page 1
...Dodmer6\Wn9Iboft VAaWYNNE-THEWINDSORnp Calc=M18 Fronk Doorfaces:N
1 wrightsoW RighW@ Worksheet Job:
Entire House Date:
QUICK CALLS, INC. By.
317 ST. LUCIE LN., F.. PIERCE, FL 34946 Phone: 772-066-6799 Fax 77246M796 Email: OUICKCALCS0,AOLDOM
1
Room name
WIC
MASTERBATH
2
Epo:etl v511
0 R
9.09.0 R
3
Room height
9.4 ItheaV=l
9A ItheaVcod
4
Room dimensions
7.0 x 9.0 R
7.0 x 9.0 ft
5
Room area
63.0 ft•
63.0 ft`
Ty
Construction
U-value
Or
HTM
Area
Load
Load
number
(BWh&-°F)
(BWh"
or perimeter (ft)
(BWh)
or�Perimeetten
(BWh)
Heat
Cool
Gross
NiPS
Heat
Cool
Gross
Heat
Cool
6
13A4ocs
0.143
n
4.00
255
0
0
0
0
00
1A-dom
1270
n
3556
34.77
0
0
0
0
00
0
0
4AS2om
0.770
n
2156
19.31
0
0
0
0
00
0
W
13A-0as
0.143
re
4A0
2.55
0
0
0
0
00
0
11
V��---G
13AAocs
0.143
e
4.00
255
0
0
0
0
00
IA-dom
1270
a
3556
87.06
0
0
0
0
00
0
�G
III---DDD
11 D0
0.390
a
1092
11.31
0
0
0 0
00
0
0
W
13A-0oa
0.143
se
4.00
2.55
0
0
0 0
00
0
VN
134Aocs
0.143
s
4.00
255
0
0
0 0
85339
2151AcNam
127o
s
3556
3a.77
0
0
0 0
00
013AAoc
0.143
w
4.00
255
0
0
0
0
00
01Aclom
1270
w
35.56
54.53
0
0
0
0
00
0tAcMom
1270
w
35.56
54.53
0
0
0
0
00
0.770
w
21-%
45.63
0
0
0
0
00
04AS2om
P
12C-0sw
0.097
2.65
128
0
0
0
0
00
0
16A30md
0.032
-
090
2.32
63
63
56
146
6356
0C
146
F
22A-tPI
0989
-
27.69
0.00
63
0
0
0
63249
0
6
c)AED exarsion
-10
-28
Envelope los4gain
56
136
644
334
12
a) Infiltration
0
0
160
45
b) Roomcendlalion
0
0
1
0
0
13
Inbamal gains: Omipants@ 230
0
0
0
0
Applianoes(other
0
0
Subt3tal(lines6t313)
56
136
1
804
379
Lesse'demal load
0
0
0
0
Lesstransrer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
56
136
W4
379
15
Dud loads
29%
57%
16
77
29°h
57%
231
216
Total room load
73
214
1036
595
Air required(dm)
3
10
43
27
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
i&A Rgte1 .021 RS2021.1arv1213:18:18
...pomrls\WrgNRM/ApWYNNE-THEWINDSORp Calc=MB FrontDoorfces: IN Page
-� wrightsoft Right--J@ Worksheet ��
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax ]72466-6796 Email: QUICKCALCS AOL.COM
1 Room name
9EA7H
KrrCHEJ
2 Fvoredwall
8.0 ft
8.0 ft
3 Room height
9.4 ft heaVcool
9.4 ft heaticool
4 Room dimensions
7.0 x 8.0 ft
1.0 x 172.0 ft
5 Room area
56.0 {(=
172A ft=
Ty
Conetructon
U-value
Or
HTM
Area
Load
number
(BUhAN-°F)
(BWhM')
or pedme�far (ft)
((�)
orAperime�ter (ft)
(Btuh)
Heat
Cool
Gros
N/P/S
Heat
Cool
/S
Heat
Cool
6
v(/ _
13A-0ocs
0.143
n
4.00
2.55
0
0
0
00
0
I---lc�'
1A-c1om
1270
n
35.56
34.77
0
0
0
00
0
0 a
4A5-2om
0.770
n
2156
19.31
0
0
0
00
0 0
W
13A-4=
0.143
ne
4.00
255
0
0
0
00
0 0
11
y/
13A-4ors
0.143
a
4A0
2S5
0
0
0
00
0 0
IF-----DG
1Aciom
1270
a
3s.5G
87.06
0
0
0
00
0 0
11D0
0.390
a
10.92
11.31
0
0
0
00
0 0
W
13A-0ocs
0.143
s
4.00
2.55
0
0
0 00
0
0
\M
�—('
13A-0ots
o.143
s
a.00
zS5
7s
ss
277
17s0
0
0
1Ac1om
1270
s
3556
34.77
6
6 213
2090
7222
0
0
13A-4oG5
0.143
w
a.ao
z.ss
o 0
0 00
0
tAc1om
1270
w
3556
54.53
0 0
0
00
0
0
G
1Ac1cm
1270
w
3556
5453
0 0
0
00
0
4A5-2om
0.770
w
21.55
45.63
0
0
0
00
0
0
0
0
P
12C-Osv
0.091
-
2S5
128
0
0
0
075
192
96
C
F
16A30md
22A-q1I
OA32
0.989
-
0.90
27.69
2.32
0.00
56
56
50
130172
154
399
56
8
222
08
222
0
6
c)AED exnrrsion
-38
-34
Envelope loss(gain
762
477
567
462
12
a) Infiltration
142
40
0
0
b) Room ventlation
0
0
0
0
13
Internal gains: Ooarpants@ 230
p
0
p
Appliancesbilw
p
p
0
Subtotal (iines6to 13)
904
517
1
567
462
Lesexamal load
0
0
0
0
Lestransfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
904
517
567
462
15
Ductloads
29%
57%
260
294
2H
57°/
163
263
Total room load
1164
811
730,31
25
733
Air required(clim)
49
37
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
2021-Jan1213:18:18
AftA RighrTFiEWINDSOsa1 Cal9.021 RSront 01
Do Page ...Caairer6\WrighSoft HUAC\WYNNE-111E WINDSORnp CaIc=M18 Frord Doorfaces:N 9
AJL wrghtsofr Right-M Worksheet Job:
Entire House Date:
QUICK CALCS, INC. BY
317 ST. LUCIE LN., FT.. PIERCE, FL 34946 Phore: 712466-6799 Fax 712466.6796 Email: OUICKCALCS@AOL.COM
1
Room name
BATH
BEDROOM2
2
Elgrosedwall
5.0 ft
42.6 ft
3
Room height
- 9.4 ft heaV000l
9A ft heaticool
4
Room dimensions
9.0 x 5.0 ft
1.0 x 204.0 ft
5
Room area
45.0 iF
204.0 tt'
Ty
Conshudon
U-value
Or
HTM
Area
Load
number
(BWh4F-'h�
(BWh@n
or penmetar (ft)
(Bhih)
or�perimeekr (ft)
(BWh)
Heat
Cool
Gras
NIPS
Heat
Cool
Gross
WPS
Heat
Cool
6
V[Lill''
13A-4ors
0.143
n
4.00
2,55
47
47
188
120
132
132
527
335
1Aa1om
1270
n
3556
34.77
0
0 0
0
0
0 0
0
4A5-2om
0.770
n
2156
1931
0 0
0
0
0 0
0
0
W
13A-4ors
0.143
ne
4.00
2.5E
0
0
0
0
27
27
106
68
11
13A-4=
0.143
a
4.00
2,55
0
0
0
0
85
65
259
164
tActcm
1270
a
3556
87.06
0
0
0
0
20
1
711
1741
11DO
0.390
a
10.92
11.31
0
0
0
0
0 0
0
0
W
13A4c s
0.143
se
4.00
2.55
0
0
0
0
27
27
106
68
13A4=
0.143
s
4.00
2S5
0
0
0
0
132
132
527
335
1Ac1om
1270
s
3556
34.77
0
0
0
0
0
0
0
0
13A4ocs
0.143
w
4.00
2.55
0
0
0
0
0
0
0
0
1Aciom
1270
w
35M
54.53
0
0
0
0
0
0
0
0
G
1Aclom
1270
w
3556
54.53
0
0
0
0
0
0
0
0
4A5-2om
0.770
w
2156
45.63
0
0
0
0
0
0
0
0
P
12c-om
0.091
2.55
128
0
0
0
0
0
0
0
0
C
16A30md
OA32
-
0.90
2.32
45
45
40
104
204
204
183
473
F
22A-tpl
0-%9
-
27.69
0.00
45
5
138
0
204
43
1179
0
6
c)AED exursim
-17
1
1
-99
Envelope iciW9ain
367
207
3599
3085
12
a) Infilfiafion
89
25
758
214
b) Rcomsenfilauon
0
0
0
0
13
Intemalgaias: Oaupants@ 230
0
1
0
0
0
Applianoasbther
0
0
Subtotal(lines64r13)
456
232
4357
3299
Leseaymaiload
0
0
0
0
Lessbanser
0
0
0
0
Redisbibutoistribufion
0
0
0
0
14
SubtYal
456
232
4357
3299
15
Durtloads
29%
579/6
131
132
29%
579%
1252
1876
Total room bad
587
364
5609
5175
Air required(dm)
25
t6
235
233
Calculations approved bVACCAto meet all requirements of Manual J 8th Ed
Ad-
�n!�ig►�t`o!t- �9CGA ^"• RigRSuc 2021Jarv1213:18:18@Uriwmi201919.021RSU08101 Page ...DownerkkWngttsDftHVAQWVNNE-THEWINDSORnp Calc=NU8 Frorit Worlaces:N
wrightsoftRight-J@ Worksheet Job;
Entire House Dot
QUICK CALCS, INC. By.
317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Prnre: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS AOL.COM
1
Room name
ENTRY
LAUNDRY
2
6yosdxall
18.0 ft
13.0 ft
3
Room height
9.4 ft heaHmol
9A ft heaV=l
4
Room dimensions
1.0 x 92A It
7.0 x 6.0 ft
5
Room area
92A fF
42.0 1F
Ty
Consirudon
U-value
Or
HTM
Area (IF)
Load
Area (M
Load
number
(Bluh4F°r7
(BWh4F)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Bluh)
Heat
Cool
Gros
N/P/S
Heat
Cool
Gross
N,P/S
Heat
Cool
6
Vrl
13A-4ors
0.143
n
4.00
2.55
0
0
0 0
0
0
0
0
1Actom
1270
n
3556
34.77
0
0
0 0
0
0
0
0
`EGG
4A5-2om
0.770
n
2156
1921
0
0
0
0
0
0
0
0
W
13A-4=
0.143
ne
4A0
2.55
0
0
0
0
0
0
0
0
11
y!
13A-4=
0.143
a
4A0
2.55
56
35
142
90
0
0
0
0
1Aclom
1270
a
35.56
87.06
0
0
0
0
0
0
0
0
IL---DG
11D0
0.390
a
10.92
11.31
21
21
229
238
0
0
0
0
W
13A-4ocs
0.143
se
4.00
2.55
0
0
0
0
0
0
0
0
13A4ors
0.143
s
4.00
2.55
0
0
0
0
56
56
226
144
1Aaiom
1270
s
35.56
34.77
0
0
0
0
0
0
0
0
13A-4ocs
0.143
w
4.01)
2.55
0
0
0
0
0
0
0
0
�G
1Aclom
1270
w
3556
54.53
0
0
0
0
0
0
0
0
IA-clom
1270
w
35.56
54M
0
0
0
0
0
0
0
0
4A5,2om
0.770
w
21M
45.63
0
0
0
0
0
0
0
0
P
12C-Ow
O.091
-
2.55
128
113
113
287
145
66
66
168
84
C
16A30md
OA32
-
090
2.32
92
92
82
213
42
42
38
97
F
22A-tpI
0.989
-
27.69
0.00
92
18
498
0
42
13
360
0
6
c)AEOe son
-49
-24
Ern lopeloss(gain
1239
637
791
301
12
a) IMtltabon
107
30
107
30
b) Roomsenfilatlon
0
0
0
0
13
Internal gains Oovpants@ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines6to 13)
1346
667
898
331
Lesseademal load
-
0
0
0
0
Lesbansfer
0
0
0
0
Redisbibuton
0
0
0
0
14
Subtotal
1346
667
898
331
15
Ductloads
29%
57%
387
379
29%
57%
258
188
Total room load
1733
1047
1156
520
Air required(Urn)
72
47
48
23
23
Calculations approved byACCAto meet all requirements of Manual J 8th Ed
_ w Ian+ cwt- 2021-Jan-1213:18:18
RigrtSutaOUnvers1201919.021 RSU08101
�� ...Doa rtAWdg%DftHVAC\WYNNE-THE WINDSORnp Calc=MIS Front Doorfaces: N Page5
�-wrightsoft° Right-l®Worksheet Job.
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LN., Fr. PIERCE, FL 34946 PFnre: 772-466-6799 Fax 772466.6795
1
Room name
GREAT/DINING
Room7
2
Bposed wall
50.0 ft
13.0 It
3
Room height
9.4 ft heaVmol
9.4 ft heaticvol
4
Room dimensom
1.0 x 567.0 ft
13.0 x 13.0 ft
5
Room area
567.0 ft-
169.0 F
Ty
Consructon
U-value
Or
HTM
Area (T)
Load
Area (fte)
Load
number
(BWhfi6--q
(Btjw
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gras
NIPS
Heat
Cool
Gross
N/P5
Heat
Cool
6VLI:S13A-4=
0.143
n
4.00
255
282
244
978
622
122
107
429
273.
1A-clom
1270
n
3556
34.77
0
0
0 0
15
0 533
522
4A5-2om
0.770
n
2156
1931
38
0 $15
730
0
0 0
0
W
13A-4os
0.143
m
4.00
2.55
0
0 0
0
0 0
0
0
11
W
13A4=
0.143
a
4.00
255
0 0
0
0
0
0
0
0
1Aclom
1270
a
35.56
87.06
0
0
0
0
0
0
0
0
I{--DG
11D0
0.390
a
10.92
11.31
0
0
0
0
0
0
0
0
w
13A-4ols
0.143
se
4.00
2,55
0
0
0
0
0
0
0
0
13A4ors
0.143
s
4.00
2,55
0
0
0
0
0
0
0
0
1Aciom
1270
a
3556
34.77
0
0
0
0
0
0
0
- 0
13A-4ocs
0.143
w
4.00
2.55
188
147
589
375
0
0
0
0
1Aclom
1270
w
3556
54.53
0
0
0
0
0
0
0
0
G
tAclon
1270
w
3556
54.53
0
0
0
0
0
0
0
0
4A5-2cm
0.770
w
2156
45.63
41
2
880
1862
0
0
0
0
P
12C-Ow
OD91
-
2.55
128
0
0
0
0
0
0
0
0
C
16A-30md
OA32
-
0.90
2.32
567
567
508
1315
169
169
151
392
F
22A-tpl
0.989
27.69
0.00
567
50
1385
0
169
13
360
0
6
c)AM examFon
307
-100
Envelope loWgain
15154
5210
1474
1086
12
a) Infiltralion
889
251
231
65
b) Roomeentilation
0
0
0
0
13
Intemal gains: Oozpants@ 230
p
0
1
230
Appiiancesrother
0
0
Subtotal(lines6to13)
6w
5461
1705
1381
Lessebemalload
0
0
0
0
Lesstransfer
0
0
0loads
03811
Redistribution
0
0
14
Subtotal
6043
5461
1705
1
15
Duct
29%
57%
1737
3105
29%
57%
490
785
Total room load
7780
8566
2195
2767
Airnquired (dm)
325
386
92
98
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
w~9~���� 2021-Jan1213:18:18
Aft Rgtt-SUtev UriWrW1201919.021RSU08101 Page
...Doa rfslWdgltDft HVADWYNNE-THEWINDSOR.np Calc=W8 FrordDoorfao?s IN
-- wrightsoft® Duct System Summary o:
Entire House BY
QUICK CALCS, INC.
317 ST. LUCIE LN., Fr. PIERCE, FL 34946 PFore:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOLCOM
Project• •
For. WYNNE DEVELOPMENT
THE W INDSOR, FT. PIERCE, FL
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0
in H2O
0
in H2O
0
in H2O
0.000/0.000
in H2O
0
in/100ft
1160
cfm
Supply Branch Detail Table
Cooling
0
in H2O
0
in H2O
0
in H2O
0.000 / 0.000
in H2O
0
in/100ft
1160
cfm
Name
Design
(Btuh)
Htg
(dim
Clg
(dm)
Design
FR
Diam
(in)
H x W
(in)
Dud
Mat
Actual
Ln (ft)
Ftq.Egv
Ln (ft)
Trunk
BATH
h 364
25
16
0
0
Ox0
ShMt
0
0
BEDROOM
c 2788
119
126
0
0
OXO
ShMt
0
0
BEDROOM2
h 2587
117
117
0
0
Ox0
ShMt
0
0
BEDROOM2-A
h 2587
117
117
0
0
Ox0
ShMt
0
0
BEDROOM -A
C 2788
119
126
0
0
OX 0
ShMt
0
0
ENTRY
h 1047
72
47
0
0
Ox0
ShMt
0
0
GREAT/DINING
c 2855
108
129
0
0
Ox0
ShMt
0
0
GREAT/DINING-A
C 2855
108
129
0
0
OXO
ShMt
0
0
GREAT/DINING-B
C 2855
108
129
0
0
Ox 0
ShMt
0
0
KrrCHEN
c 725
31
33
0
0
Ox0
ShMt
0
0
LAUNDRY
h 520
48
23
0
0
Ox0
ShMt
0
0
K BATH
h 811
49
37
0
0
Ox 0
ShMt
0
0
MASTERSATH
h 595
43
27
0
0
0x0
ShMt
0
0
Rovrt7
C 2167
92
98
0
0
Ox0
ShMt
0
0
wic
c 214
3
10
0
0
Ox0
ShMt
0
0
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cim)
Clg
(I
TEL
(ft)
Design
FR
Veloc
(fpm)
Dian
(in)
HxW
(in)
Stud/Joist
Opening (in)
Dud
Mat
Trunk
rb1
OxO
1160
1160
0
1 0
0
0
Ox 0
ShMt
Wright"soit' 2021Ja 1213:1e:19
+.�-� «..•m—,w•o., RigN-SUte®Umer51201919.021RSU08101 Pagei
...Doamertr\WrigFYsoft FNAQWYNNE-TFiEWINDSOR.np Calt=M18 Fmit Doorfaces:N