HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE WINDSOR IMPACT
Street: THE WINDSOR
City, State, Zip: FT. PIERCE, FL,
Owner:
Design Location: FL, Fort Pierce
Builder Name: WYNNE DEVELOPMENT
Permit Office: ST. LUCIE COUNTY
Permit Number:
Jurisdiction:
County: St. Lucie (Florida Climate Zone 2 }
1. New construction or existing New (From Plans)
10. Wall Type$1432.0 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1224.00 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
c. NIA
R=11.0 208.00 ft
R= ftz
4. Number of Bedrooms 3
d. NIA
R= ft2
5. Is this a worst case. Yes
11. Ceiling Types (1783.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1753,00 ft2
6. Conditioned floor area above grade (W) 1753
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft2
7. Windows(151.4 sgft.) Description Area
12. Ducts
R ftz
a. U-Factor: Sgl, U=1.02 111.36 ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 195
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ftz
13. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: NIA ftz
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
14. Heating systems
kBtulhr Efficiency
Area Weighted Average SHGC: 0.285
a. Electric Meat Pump
34.8 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) NIA ft2
15. Hot water systems
SHGC(AVG): NIA
a. Electric
Cap: 40 gallons
9. Floor Types (1753.0 sgft.) Insulation Area
a. Slab -Ors -Grade Edge Insulation R=0.0 1753.00 ft2
b. Conservation features
EF: 0.970
b. NIA R= ft2
None
c. NIA R= ft2
16. Credits
None
Total Proposed Modified Loads: 49.38
Glass/Floor Area: 0.086
ASS
Total Baseline Loads: 50.69
I,1
I hereby certify that the plans and specifications covered by
Review of the plans and
O-flaE
this calculation are in compliance with the Florida Energy
specifications covered by this
p
Code.
calculation indicates compliance
the Florida Energy
y�4' `�' = � 10.
with Code.
� rrrr :•. '�, ,;_r �, �` O
PREPARED BY:
Before construction is completed
w 0
DATE: 1-12-2021
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as desi n ompliance
Florida Statutes.
with the Florida Energy C
,+
G'��WS
OWNER'
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure
qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection
Checklist in accordance with R402.4.1.1
and this project requires an
envelope leakage test report with envelope leakage no greater
than 5.00 ACH50 (R402.4.1.2).
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE WINDSOR IMP Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1753
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT
Rotate Angle: 180
Street:
THE WINDSOR
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Detached
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1753 14024
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 MASTER BEDROO
224 1792 No
0
1
1
Yes
Yes
Yes
2 WIC
63 504 No
0
1
No
Yes
Yes
3 MASTER BATH
56 448 No
0
1
Yes
Yes
Yes
4 M. BATH
61 488 No
0
1
Yes
Yes
Yes
5 LAUDRY
36 288 No
0
1
No
Yes
Yes
6 BEDROOM 2
180 1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREAT R
588 4704 No
2
1
Yes
Yes
Yes
8 KITCHEN
209 1672 Yes
0
1
Yes
Yes
Yes
9 BATH
50 400 No
0
1
Yes
Yes
Yes
10 HALL
25 200 No
0
1
No
Yes
Yes
11 FOYER
92 736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3
169 1352 No
0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
MASTER BEDRO 37 ft 0
224 ft2
___
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ft2
0 1
0
3 Slab -On -Grade Edge Insulatio
MASTER BATH 8 ft 0
56 ft2
_-
0 1
0
4 Slab -On -Grade Edge Insulatio
M. BATH 7 ft 0
61 ft2
0 1
0
5 Slab -On -Grade Edge Insulatio
LAUDRY 1 ft 0
36 ft2
__
0 1
0
1/12/2021 1:15 PM EnergyGauge© USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
6SIab-On-Grade Edge Insulatio
BEDROOM 2 12 ft
0
180 W
—
0 1
0
7 Slab -On -Grade Edge Insulatio
DINING/GREAT 50 It
0
588 ft.
_
0 1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN 11 ft
0
209 ft-
___
0 1
0
9 Slab -On -Grade Edge Insulatio
BATH 5 ft
0
50 ft.
0 1
0
10SIab-On-Grade Edge Insulatio
HALL 1 It
0
25 ft'
___
0 1
0
11SIab-On-Grade Edge Insulatio
FOYER 9 It
0
92 ft'
0 1
0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 ft
0
169 ft-
__
0 1
0
ROOF
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
1/
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Metal 1847 ft-
0 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft'
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area -
Framing Frac Truss Type
1 Under Attic (Vented)
MASTER BEDRO
30
Blown
224 ft-
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63 ft'
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 ft-
0.1
Wood
6 Under Attic (Vented)
BEDROOM 2
30
Blown
180 ft'
0.1
Wood
7 Under Attic (Vented)
DINING/GREAT
30
Blown
588 ft'
0.1
Wood
8 Under Attic (Vented)
KITCHEN
30
Blown
209 ft2
0.1
Wood
9 Under Attic (Vented)
BATH
30
Blown
50 fI2
0.1
Wood
10 Under Attic (Vented)
HALL
30
Blown
25 ft'
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
92 ft'
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3
30
Blown
169 ft'
0.1
Wood
13 Knee Wall (Vented)
DINING/GREAT
19
Blown
30 ft'
0.11
Wood
WALLS
Adjacent
Space Cavity Width
Height
Sheathing Framing Solar Below
1
NE=>SW Exterior Concrete Block
- Int InsMASTER BE 4.1 16
0 8
0
128.0 ft2
0
0 0.3
0
_ 2
SW=>NE Exterior Concrete Block-
Int InsMASTER BE 4.1
7
0 8
0
56.0 ft2
0
0 0.3
0
3
NW=>SE Exterior Concrete Block
- Int InS09ASTER BE 4.1
14
0 8
0
112.0 W
0
0 0.3
0
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
urr�rrT cr rwnwllAOV !`LIC(`I[I ICT RF0111RT
rUKNI R4V�-4V4V
u.r v . vv nu..rv. •
- - -
- -
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
BGiVW
S%AWR Typepace
°
NE=>SW Exterior
Concrete Block- Int InsMASTER SA
4.1 8 0
8 0
64.0 ft2
0
0 0.3
0
-4
NE=>SW Exterior
Concrete Block - Int Insul M. BATH
4.1 7 0
8 0
56.0 ft2
0
0 0.3
0
-5
_ 6 NE=>SW Exterior
Concrete Block - Int In$aEDROOM 2
4.1 12 0
8 0
96.0 ft2
0
0 0.3
0
7 SW=>NE Exterior
Concrete Block- Int InsQNING/GRE
4.1 30 0
8 0
240.0 ff
0
0 0.3
0
8 NW=>SE Exterior
Concrete Block - Int Ins0INING/GRE
4.1 20 0
8 0
160.0 ft2
0
0 0.3
0
9 SW=>NE Exterior
Concrete Block- Int InsuIKiTCHEN
4.1 11 0
8 0
88.0 ft2
0
0 0.3
0
_
10 NE=>SW Exterior
Concrete Block- Int Insul BATH
4.1 5 0
8 0
40.0 ft2
0
0 0.3
0
_ 11 SE=>NW Exterior
Concrete Block - Int Insul FOYER
4.1 8 0
8 0
64.0 ft-
0
0 0.3
0
12 SW=>NE Exterior
Concrete Block - Int Insul FOYER
4.1 1 0
8 0
8.0 ft2
0
0 0.3
0
13 NE=>SW Exterior
Concrete Block - lnt InsBEDROOM 3
4.1 13 0
8 0
104.0 ft2
0
0 0.3
0
_
14 SW=>NE Exterior
Concrete Block - Int InsBEDROOM 3
4.1 1 0
8 0
8.0 ft-
0
0 0.3
0
15 N=>S Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft2
0.23 0.3
0
DOORS
# Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>NW Insulated FOYER
None
.39
3
3
6 a 21.7 ft2
WINDOWS
Orientation shown is the entered orientation => chan ed to Worst Case.
Overhang
JWall
# Omt ID
Frame Panes NFRC U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
_ 1 NW=>SE 3
Metal Low-E Single Yes
1.02 0.29 Y
32.4 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2 NE=>SW 5
Metal Low-E Single Yes
1.02 0.29 Y
6.9 ft2
1 ft 0 in
1 ft 4 in
None
None
_ 3 NE=>SW 6
Metal Low-E Single Yes
1.02 0.29 Y
16.2 ft2
1 ft 0 in
1 ft 4 in
None
None
4 SW=>NE 7
Metal Low-E Single Yes
1.02 0.29 Y
39.8 ft2
1 ft 0 in
1 ft 4 in
None
None
_ 5 NW=>SE 8
Metal Low-E Single Yes
1.11 0.27 Y
40.0 ft2
8 ft 0 in
1 ft 4 in
None
None
6 NE=>SW 13
Metal Low-E Single Yes
1.02 0.29 Y
16.2 ft2
1 R 0 in
1 ft4 in
Drapes/blinds
Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 806 ft2 806 ft,
26 It
8 It
11
INFILTRATION
# Scope Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000254 1168.7 64.12
120.37
.0902
5
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Sing[ HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR Block
Ducts
1 Central Unit/
Split
Sing] SEER: 15 34.8 kBtu/hr cfm 0.85 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System Model # Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
/ -- Supply —
— Return --
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT ON RLF
Heat Cool
1 Attic 6 195 ft2
Attic
55 ft2 Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programablrj, Thermostat: N
Ceiling Fans:
Cooling Jan Feb Mar
b Mar
Venting
Ap
Apr
Ju
May Jun
Jun Jul
Aug
rjXj�
Nov
OctNov
rjX,j
Dec
[ ]Jan Feb X Mar
May
Aug
[ ] Sep
[ ]X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7
8
9 10 11
12
Cooling (WD) AM 78
PM 78
78 78
78 78
78 78 78
78 78 78
78
78
78 78 78
78
78
78
78 78 78
78
Cooling (WEH) AM 78
78 78
78 78 78
78
78
78 78 78
78
PM 78
78 78
78 78 78
78
78
78 78 78
78
Heating (WD) AM 68
68 68
68 68 68
68
68
68 68 68
68
PM 68
68 68
68 68 68
68
68
68 68 68
68
Heating (WEH) AM 68
68 68
68 68 68
68
68
68 68 68
68
PM 68
68 68
68 68 68
68
68
68 68 68
68
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 ]bs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(81bs/sq.ft.
ft2
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
M. BATH
Defau]t(81bs/sq.ft.
ft'
ft
0.3
LAUDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(81bs/sq.ft.
ft2
ft
0.3
DINING/GREAT R
Default(81bs/sq.ft.
ft2
ft
0.3
KITCHEN
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area Thickness Furniture Fraction
Space
Default(8 lbs/sq.ft.
ft' ft 0.3
BATH
Default(8 lbs/sq.ft.
ft' ft 0.3
HALL
Default(8 lbslsq.ft.
ft' ft 0.3
FOYER
Default 8 Ibs/s .ft.
ft' ft 0.3
BEDROOM 3
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY
City, Slate, Zip: Ff. PIERCE, FL Permit Number.
Y
w
Owner: Jurisdiction:
_
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceilinglsoffit shall be aligned with
The insulation in any dropped ceiling/soffit
Ceiling/attic
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
Walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace wall
.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
Narrow cavities
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box o
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, watt covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
betN n fire siaunkler cover plates and wails or ceifilWs.
I
a. In addition, inspection of log walls snail be in accorcance win me pruvrsiuus ui iw vv.
111212021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
T Windows" Description
a. U-Factor. Sgl, U=1.02
SHGC: SHGC=0.29
b. U-Factor. Sgl, U=1.11
SHGC: SHGC=0.27
c. U-Factor: N/A
SHGC:
d. U-Factor. N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
6. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
THE WINDSOR, FT. PIERCE, FL,
New (From Plans)
10, Wall Type and Insulation
Insulation
Area
a. Concrete Block - Int Insul, Exterior
R=4.1
1224.00 ft
Detached
b. Frame - Wood, Adjacent
R=11.0
208.00 ft'
1
c. N/A
R=
fF
3
d. NIA
R=
ft'
11. Ceiling Type and insulation level
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1753.00 ft2
1753
b. Knee Wall (Vented)
R=19.0
30.00 ft2
c. NIA
R=
ft2
Area
12, Ducts, location & insulation level
R ft2
111.36 ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 195
40.00 ft'
13, Cooling systems
kBtu/hr
Efficiency
ft'
a. Central Unit
34.8
SEER:15.00
ft2
Z850 ft.
0.285
Area
W
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2
b. N/A R= ft'
c. N/A R= ft
14, Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant 2
Builder Signature: � Date:
Address of New Home: City/FL Zip: -
-7-kQi5 l
`Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
kBtulhr Efficiency
34.8 HSPF:8.50
Cap: 40 gallons
EF: 0.97
None
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/12/2021 1:15 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
wrightsoft° Pro ect Summary '�Job:Ent re House Da
QUICK CALCS, INC.
317ST. LUCIE LN., Fi PIERCE, FL 34946 PIore: 772-466.6799 Fax T2-466-6796 Emil: QUICKCALCS@AOL.CQM
For. WYNNE DEVELOPMENT
THE WINDSOR, FT. PIERCE, FL
Notes:
Design
Weather: Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42
OF
Outside db
90
OF
Inside db 70
OF
Inside db
75
OF
Design TD 28
OF
Design TD
15
OF
Daily range
L
Relative humidity
50
%
Moisture difference
61
gr/lb
Heating Summary
Sensible Cooling Equipment Load
Sizing
Structure 21542
Btuh
Structure
16420
Btuh
Ducts 6191
Btuh
Duds
9337
Btuh
Central vent (0 dm) 0
Btuh
Central vent (0 cfm)
0
Btuh
none
(none)
Humidification 0
Btuh
Blower
0
Btuh
Piping 0
Btuh
Equipmentload 27734
Btuh
Use manufacturers data
n
Rate/swing multiplier
Equipment
0.95
Infiltration
sensible
load
24470
Btuh
Method Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
2495
Btuh
Ducts
2646
Btuh
Central vent (0 cfm)
0
Btuh
Heatingg
Coolingg
(none)
Area (ft) 1753
1753
Equipment latent load
5041
Btuh
Volume (ft3) 16478
16478
Airchanges/hour 0.38
020
Equipment Total Load (Sen+Lat)
29511
Btuh
Equiv.AVF (cfm) 104
55
Req. total capacity at 0.70 SHR
2.9
ton
Heating Equipment Summary
Cooling Equipment Summary
Make Carrier
Make Carrier
Trade CARRIERAIR CONDITIONING
Trade CARRIERAIR CONDITIONING
Model 25HBC536A 030
Cond 25HBC536A 030
AHRI ref 7914585
Coil FX4DN(B,F)037
AHRI ref
Efficiency 8.5 HSPF
Efficiency7914585 12.0 EER,15
SEER
Heating input
Sensible cooling
24360
Btuh
Heating output 34600
Btuh @47°F
Latentcooling
10440
Btuh
Temperature rise 27
OF
Total cooling
34800
Btuh
Actual airflow 1160
cfm
Actual airflow
1160
cfm
Airflowfador 0.042
dm/Btuh
Airflowfador
0.045
cfm/Btuh
Static pressure 0
in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.84
Capacity balance point = 36 OF
Backup:
Input=7kW, Output= 23009 Btuh, 100 AFUE
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wriigntsof - 2021-Jan1213:18:18
RgitSULS Uriversal 201919.021 RSU08101 Page1
...DIa rls\WrigFtsot HVAC\WYNNE-THEWINDSORnp Calc=Uk Fmft Doortams:IN
-FkF,,,,r;ghtsoft Right-J® Worksheet Job.'
:
Entire House By.
QUICK CALCS, INC.
v17 cT I r..IP IN FT PIFRCE FL 34946 Prom: 7724666799 Fax 772466-6796 Email: DUICKGALCS AOL.COM
1
Room name
Erdre House
BEDROOM
2
E1posed well
207.6 it
41.0 It
3
Room helgM
9.4 ft d
9.4 it r*3vco l
4
5
Room dimensions
Roomarea
1753.0 ft�
14.0 x 20.0 it
280.0 fF
Ty
Construction
U-value
Or
HTM
Area (fl
Load
Area (IM
(it)
Load
(BWh)
number
(BWhflP--T)
(SWhAM
or perimeter (it)
(BWh)
or perimeter
Cool
Gross
N/PS
Heat
Cool
Gross
N/P5
Heat
Cool
6
13A4ocs
0.143
n
2.55
649
596
2386
1617
66
66
263
167
tAclom
1270
n
34.77
15
0
533
522
0
0
0
0
0
4Arr2om
0.770
n
19.31
38
0
815
730
0
0
0
W
13A 4oz
0.143
ne
r2l.56
2.55
27
27
106
68
0
0
0
0
0
1
13AAocs
0.143
a
2.55
141
100
400
255
0
0
0
tAc'lam
1270
a
87.06
20
1711
1741
0
0
0
0
0
LLLL��..DDDD1100
Omit
a
11.31
21
21
229
238
0
0
0
W
13A4o s
0.143
se
2.55
27
27
106
68
0
0
0
0
W13PA=
0.1
s
2.55
536
5?!J
2121
1349
188
1
753
479
0
L—G
lgtlom
1270
s
3556
34.77
6
6
213
209
0
0
0
13A4os
0.143
w
4.00
2S5
320
255
1022
649
132
108
432
275
1"I m
1270
w
3555
54.53
12
1
415
636
12
1
415
636
1A 1=
1270
w
3556
5453
12
1
427
654
12
1
427
654
4A5-2om
0.770
w
2156
45.63
41
2
880
1862
0
0
0
0
0
P
12C11ev
0.091
-
255
128
264
254
647
326
0
0
0
C
16A30md
0.032
-
0.9D
2.32
1753
1753
1571
4067
280
280
251
650
F
22A-tpl
0.969
-
27.69
0.D0
1753
208
5748
0
280
41
1135
0
6
c)AED elusion
397
488
Ernelopelossrgain
18331
15285
1
36761
3349
12
a) hrfiltradon
3211
905
729
0
2D5
0
b) Roameentrlabon
0
0
13
Internal gains OmrpanM@ 230
1
230
0
0
0
0
Appliarxes(other
Subtotal (lire ft 13)
21542
16420
4405
3554
Leaswdamalload
0
0
0
0
0
0
0
Lesstransfer
0
0
0
0
0
Redistribulim
26191
19337
4405
3554
14
Subtotal
29°h
57%
6197
9337
29%
57%
7266
.1
202t
15
Dudloads
Total room load
27734
1160
25757
1160
5671
237
5575
257
Air required(dn)
wrl�ghtso7�t'
RIgrtStile®Udversa1207919.027 RSU08101
...Doameri,\W6gasofWACAWYNNE-THEWINDSOR P Caic=W8 Froo Doorf3Ws:N
2021-Jan-12131818
Page 1
wrightsoft° Right-M Worksheet Job.'
Entire House Dale:
QUICK CALCS, INC. By.
317ST. LUCIE LN.,Fr.PIERCE, FL 34946 Phore: 772466-679917c7724666796 Email: QUICKCALCS@AOL.COM
1
Raom name
WIC
MASTER BATH
2
Eayosedvtall
0 it
9.0 a
3
Room height
9.4 It heaV=l
9A It heatb5d
4
Room dimerx9ons
7.0 x 9.0 it
7.0 x 9.0 ft
5
Room area
63.0 R
63.0 T
Ty
Construction
U-value
Or
HTM
Area (
Load
Area RD
Load
number
I
or perimeter (It)
(BWh)
or perimeter (ft)
(BWh)
Heat
Cool
Gross
NrPS
Heat
Cool
Gross
N/P/S
Heat
Ccol
6
13A-4ors
0.143
n
4.00
2.5E
0
0
0 0
0
0
—G
T-
1A-dw
1270
n
3556
34.77
0
0
0 0
0
0
0
0
0
0
G
4A5-2om
0.770
n
2156
19.31
0
0
0 0
0
0
0
0
W
13A4ors
0.143
ne
4.00
2.55
0
0
0
0
0
0
0
0
11
13A4as
0.143
a
4A0
255
0
0
0
0
0
0
0
0
1Ao1om
1270
a
3556
87.06
0
0
0
0
0
0
0
0
11DO
0"
a
10.92
11.31
0
0
0
0
0
0
0
0
W
13A4ors
0.143
se
4.00
255
0
0
0
0
0
0
0
0
13A4ors
0.143
s
4A0
2.55
0
0
0
0
85
85
339
215
1A-dom
1270
5
35.56
34.77
0
0
0
0
0
0
0
0
13A4ocs
0.143
w
4.00
2.55
0
0
0
0
0
0
0
0
1Ac1om
1270
w
35,56
54.53
0
0
0
0
0
0
0
0
tAolom
1270
w
3556
5453
0
0
0
0
0
0
0
0
4A5.2om
0.770
w
21.56
45.63
0
0
0
0
0
0
0
0
P
12C-Ow
OD91
255
128
0
0
0
0
0
0
0
0
C
16A30md
0.032
-
090
2.32
63
63
56
146
63
63
56
146
F
22A-lpl
0.989
-
27.69
0.00
63
0
0
0
63
9
249
0
6
c)AED e=rsim
-10
-28
Emelopeloss/gain
56
136
644
334
12
a) Infiltration
0
0
160
45
b) Roornwntilation
0
0
0
0
13
Intemalgaine: OmrpaM@ 23D
0
0
0
0
Appliaricesbther
0
0
Subbtal(lines6b13)
56
136
8D4
379
Lmademalload
0
0
0
0
Lesstransrer
0
0
0
0
Redishibubon
0
0
0
0
14
Subbllal
55
136
804
379
15
Dudloads
29°h
57%
16
77
29%
57%
231
216
Total room load
73
214
7036
59E
Airrequired(dm)
3
10
43
27
Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed
wr;gpvea, - 2021-JarN213:18:18
Aft RigHSdte@ UriwmJ 201919.021 RSU08101 Page 2
...DorsmertslWrigFtmftHVAC\WYNNE-THEWINDSORnp Calc=NJ6 FrokDDorfares:N g
}l- wrightslafC Right-J® WorksheetJOIN
Dates
Entire House By.
QUICK CALCS, INC.
¢,7 cT It R:IP IN F7 PIFRCE. R 34946 Phare:772-466-6799 Far 772466-6796 Email: QUICKCALCS AOL.COM
1
Room name
MBATH
KITCHEN
2
Expos°dvall
8.0 It
8.0 It
3
Room height
9.4 It heatkool
9.4 ft heaVood
4
Room dimensions
7.0 x 8.0 It
56.0 fF
1.0 X 172A ft
172.0 f
5
Room area
Ty
Construction
U-value
Or
HTM
Area OF)
Load
(Stun)
Area (T)
or (ft)
Load
(Bluh)
number
(BWhfe-'9
(BWh4P)
or penmeter (ft)
perimeter
Cool
Gras
NIPS
Heat
Cool
Gros
NIPS
Heat
Cool
6
13A4ors
0.143
n
2.55
0
0
0
0
0
0
0
0
0
0
0
0
1Aclom
1270
n
34.77
0
0
0
0
0
0
4AS2om
0.770
n
19.31
0
0
0
0
0
0
W
13A-0ors
0.143
ne
r35,506
2.55
0
0
0
0
0
00
0
0
0
11
13PAocs
0.143
a
2.55
0
0
0
0
0
0
IGtAc1om
1270
a
67.06
0
0
0
0
0
0
0
0
0
L-D11D0
0.390
a
11.31
0
0
0
0
0
0
0
0
W
1344o1s
0.143
se
2.55
0
0
0
0
0
0
0
lM13A-4ocs
0.143
5
255
75
69
277
176
0
0
0
0
0
I—f
1Aciom
1270
s
3556
34.77
6
6
213
209
0
0
0
13A-4ocs
0.143
w
4.00
2.55
0
0
0
0
0
0
a
0
tAclom
1270
w
35.56
54.53
0
0
0
0
0
0
0
0
G
1Aclom
1270
w
35.56
5453
0
0
0
0
0
0
0
0
4A5-2om
0.770
w
21 S8
45.63
0
0
0
0
0
0
0
75
0
75
0
192
0
96
P
12COw
0.D91
-
2.55
128
0
0
C
164-30md
0.032
0M
2.32
56
56
50
130
172
172
154
399
F
22A-Ipl
0.989
-
27.69
0.00
56
8
222
0
172
8
222
0
6
c)AEDexoura,n
-38
-S4
Envelope lossrgam
762
477
567
462
12
a) Infiltiaton
142
40
0
0
0
0
b) Roomvenfilation
0
0
13
Intemal gains O=pants@ 230
0
0
0
0
0
Applianxstother
0
Subtotal (Mes6to 13)
904
517
567
462
Less emmal load
0
0
0
0
0
0
Lesstrander
0
0
0
0
0
0
Redistribution
904
517
567
462
14
Subtotal
1 29%1
57°/,
260
294
29%
57%
163
263
15
Dud loads
1164
811
730
725
Total room load
49
37
31
33
Airrequired(dm)
Calculations approved bvACCAtO meet all requirements of Manual J_M Ed.
wr19n>��` 2021-Jan1213.
Page
3
�• Ii�gttSUte®Uriversa12019 t9.021 RSU08101 3
...DocmarZ\WnghWRHVALYWYNNE-THEWINDSORnp Calc=M78 FroNDoorta=N
XLL rfrwrightsofr Right-& Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 P1ore: 772-466-6799 Fax 7724666796 Email: QUICKCALCS@AOL.COM
1
Room name
BATH
BEDROOM2
2
Fposedwall
5.0 It
42.6 It
3
Room height
- 9.4 ft heaV=l
9.4 ft heaVcool
4
Room dirreru.
9.0 x 5.0 ft
1.0 x 204.0 it
5
Room area
45.0 IF
204A I
Ty
Construction
U-value
Or
HTM
Area
Load
�(fe)
Load
number
(BWhAtLn
(BWh4F)
or perimeter (ft)
(BWh)
or perimeter M
(BWh)
Heat
Cool
Gros
NIPS
Heat
Cool
Gros
NIPIS
Heat
Cool
6
1�/
13A4=
0.143
n
4.00
2.55
47
47
188
120
132
132
527
335
1Aclom
1270
n
35.56
34.77
0
0
0
0
0
0
0
0
LLj
4A5-2om
0.770
n
2156
1931
0
0
0
0
0
0
0
0
W
13A4as
0.143
ne
4.00
255
0
0
0
0
27
27
106
68
11
13A4=
0.143
a
4A0
2.55
0
0
0
0
85
65
259
164
1Ac1om
1270
a
35.56
87.06
0
0
0
0
20
1
711
1741
11DO
0.390
a
10.92
11.31
0
0
0
0
0
0
0
0
W
13A4=
0.143
se
4.00
255
0
0
0
0
27
27
106
68
13A4ors
0.143
s
4A0
2.55
0
0
0
0
132
132
527
335
1Aclom
1270
s
35.56
34.7
0
0
0
0
0
0
0
0
13A-4=
0.143
w
4.00
2.55
0
0
0
0
0
0
0
0
1A-clom
1270
w
3556
54.53
0
0
0
0
0
0
0
0
G
1Aclom
1270
w
35.56
54.53
0
0
0
0
0
0
0
0
4A5-20m
0.770
w
2156
45.63
0
0
0
0
0
0
0
0
P
12C-Ow
0.091
2.55
128
0
0
0
0
0
0
0
0
C
16A30md
0.032
-
0.90
2.32
45
45
40
104
204
204
183
473
F
22A-tp1
0.989
-
27.69
0.00
45
5
136
0
204
43
1179
0
6
0)AED e=rslon
-17
.99
Envelope los/;ain
367
207
1
3599
3085
12
a) Infiltration
89
25
758
214
b) Roomvenfilaton
0
0
0
0
13
Intemal gains: O=panls@ 230
0
0
0
0
Applianceslother
0
0
Subtotal(Ilrles6to 13)
456
232
4357
3299
Leseztmalload
0
0
0
0
Lestransfer
0
0
0
0
Redistribution
0
0
0
0
14
Subbbl
456
232
4357
3299
15
Oudloads
29%
57%
131
132
29%
57%
1252
1876
Total room lead
587
364
5609
5175
Air required(dm)
25
16
1
235
233
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
wrlct2v oft- 20214an1213:18:18
RigkSute@Uriw=1201919.021 RSU08101
.4CCh ...Dor r6iWdgFE ftHVAC\WVNNE-THE WINDSORl Calc=KW Frort Ooorfaoee: N Page
wrightsoft- RighW@ Worksheet Job:
Entire House Date:
QUICK CALCS, INC. BY
317 ST. LUCIE UN., Fr. PIERCE, FL 34946 P1ore: 772-466-6799 Fax T72-466£796 Email: QUICKCALCS@AOL.COM
1
Room name
ENTRY
LAUNDRY
2
E)posd wall
18.0 ft
13.0 It
3
Room height
9.4 ft heaV=l
9.4 ft heaV=l
4
Room dimensons
1.0 x 92.0 ft
7.0 x 6.0 ft
5
Room area
92.0 ft'
42.0 IF
Ty
Construction
U-value
Or
HTM
Area
Load
number
(BWhft-*F)
(BWhd')
or perimeter (ft)
(BWh)
cr�perimeter M
(BWh)
Heat
Cool
Gros
N/P/S
Heat
Cool
Gros
N/P/S
Heat
Cool
6
lM
13A-4=
0.143
n
4.00
2.55
0
0
0
0
0
0
0
0
IA-clom
1270
n
35.56
34.77
0
0
0
0
0
0
0
0
II---GG
4A5-2om
0.770
n
21.56
1931
0
0
0
0
0
0
0
0
w
13A-4ors
0.143
ne
4.00
255
0
0
0
0
0
0
0
0
11
13A-0Cr_s
0.143
a
4.00
255
56
35
142
90
0
0
0
0
1Ac1om
1270
a
35.56
87.06
0
0
0
0
0
0
0
0
11DO
0.390
a
10.92
11.31
21
21
229
238
0
0
0
0
W
13A4a
0.143
se
4.00
2.55
0
0
0
0
0
0
0
0
13A4a
0.143
s
4.00
255
0
0
0
0
56
56
226
144
1Ac1am
1270
s
35.56
34.77
0
0
0
0
0
0
0
0
13A-4=
0.143
w
4.00
255
0
0
0
0
0
0
0
0
1Atlom
1270
w
3556
54.53
0
0
0
0
0
0
0
0
1A.clom
1270
w
35S
54.53
0
0
0
0
0
0
0
0
4A5-2om
0.70
w
21M
45.63
0
0
0
0
0
0
0
0
P
12C-0sv
0.091
-
255
128
113
113
287
145
66
66
168
84
C
16A30md
0-032
-
0.90
2.32
92
92
82
213
42
42
38
97
F
22Xtpl
0369
-
27.69
0.00
92
18
498
0
42
13
360
0
6
C) AM e=t son
qg
-Y4
EnselopeloWgain
1239
637
1
791
301
12
a) IMilbWon
107
30
107
30
b) Roomsentilation
0
0
0
0
13
Internal gains Oovpants@ 230
0
0
0
0
Appliancadotier
0
0
Subtolal(lines6to 13)
1346
667
898
331
Les exemal load
0
0
0
0
Lesstanser
0
0
0
0
Rediseibulion
0
0
0
0
14
Subtotal
1346
667
898
331
15
Ductloads
29%
SPA
387
379
29%
57%
258
188
Total mom load
1733
1047
1
1156
520
Air required(dm)
72
47
48
23
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed.
M!10ntsoft-
Rigd-Sute®Uriversal 201919.021 RSU08101 2021 Jan121 Page 5
...Doa rts\WdglmftFNAC\WYNNE-THEWINDSORxw Calc=M18 FrontDoorfaces: IN9
wrightsofr Right-JO Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phme: 772466-6799 FaK 772466-6796 Email: QUICKCALCS a@4OL.COM
1
Room name
GREATZINWG
Room7
2
3
Bposedwall
Room height
50.0 ft
9.4 ft heattmol
13.0 ft
9.4 ft heaVcool
4
5
Room dimensions
Room area
1.0 x 567.0 ft
567.0 IF
13.0 x 13D ft
169.0 P
Ty
Conslmclim
number
U-value
(BWhAPL-F)
Or
HTM
(BWhffl�
Area (fl
or perimeter (ft)
Load
(Btuh)
Area (tle)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gros
NIPS
Heat
Cool
Gros
NIPS
Heat
Cool
6
13A4ocs
1Ac1om
4A5-2om
0.143
1270
0.770
n
n
n
4.00
35M
2156
2.55
34.TI
19,31
282
0
38
244
0
0
978
0
815
622
0
730
122
15
0
107
0
0
429
533
0
273
522
0
11
W
lq/
13A4o s
13A4s
o
0.143
0.143
ne
a
4.00
4A 0
2.55
2S5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
II--DG
1Ac1om
11DO
13A4os
1270
0.390
0.143
a
a
w
3556
10.92
4.00
87.06
11.31
2.55
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
W
W
--G
1344o s
1Ac1om
0.143
1270
s
s
4.00
3556
2.55
34.77
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
13A4os
1Ac1om
1A-c1on
0.143
1270
1270
w
w
w
4.00
3556
3556
2.55
54.53
54.53
188
0
0
147
0
0
589
0
0
375
0
0
0
0
0
0
0
0
0
0
0
0
0
0
P
4A5.2om
12C41sv
O- 70
OD91
w
2156
255
45.63
128
41
0
2
0
880
0
1862
0
0
0
0
0
0
0
0
0
C
F
16A30md
22A-tpl
0.032
0-%9
-
-
0.90
27.69
2.32
0.00
567
567
567
50
508
1385
1315
0
169
169
169
13
151
360
392
0
6
c)AED e=rson
307
-100
Envelope loss/gain
15154
5210
1474
1086
12
a) Infiltration
b) Roomverltilation
889
0
251
0
231
0
65
0
13
Intemal gaim: Ooalpanls@ 230
Appliancesbther
0
0
0
1
230
0
Subotal(Ilnes6to 13)
6043
5461
1705
1381
Lese*rnalload
0
0
0
0
14
15
Lesstransfer
Redistibudon
Subtltal
Ductloads
29%
57%
0
0
6043
1737
0
0
5461
3105
29%
57%
0
0
1705
490
0
0
1381
785
Total room load
Air required(drr)
T780
3251
8566
386
2195
92
2167
98
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
'41- w��9h=sot'[` 2021-Jarv1213.18.18
.4C'LA RigrtSute®Uriversal 201919.021 RSU08101 Page 6
...Doamer WdghsDft HVAC,WVNNE-THEWINDSORnp Calc=MIB Front Doorfar.Es:N
wrightsoft Duct System Summary �1
Entire House By.
QUICK CALCS, INC.
317 ST. LUCIE LN„ FT. PIERCE, FL 34946 Prone: 772-466-6799 Fax 772466.6796 Email: QUICKC4LCS@4OL.COM
Project Information
For. WYNNE DEVELOPMENT
THE WINDSOR, FT. PIERCE, FL
EXtemal static pressure
Pressure losses
Available static pressure
Supply/return available pressure
Lowe"don rate
Actual airflow
Total effective length (TEL)
Heating
0
in H2O
0
in H2O
0
in H2O
0.000/0.000
in H2O
0
in/100ft
1160
cfm
M
Supply Branch Detail Table
Cooling
0
in H2O
0
in H2O
0
in H2O
0.000 / 0.000
in H2O
0
in/100ft
1160
cfm
Name
Design
(Btuh)
Htg
(drn)
Clg
((*m)
Design
FR
Diam
(in)
H x W
(in)
Duct
mat
Actual
Ln (it)
Ftg.Egv
Ln (it)
Trunk
BATH
h 364
25
16
0
0
Ox0
ShMt
0
0
BEDROOM
Q 2788
119
126
0
0
OXO
ShMt
0
0
BEDROOM2
h 2587
117
117
0
0
OxO
ShMt
0
0
BEDROOM2-A
h 2587
117
117
0
0
0x0
ShMt
0
0
BEOROOM-A
C 2788
119
126
0
0
Ox0
ShMt
0
0
ENTRY
h 1047
72
47
0
0
0x0
ShMt
0
0
GREAMOINM
C 2855
108
129
0
0
Ox 0
ShMt
0
0
GREADDINING-A
C 2855
108
129
0
0
0x0
ShMt
0
0
GREATIDNING-B
C 2855
108
129
0
0
Ox 0
ShMt
0
0
KITCHEN
C 725
31
33
0
0
Ox0
ShMt
0
0
LAUNDRY
h 520
48
23
0
0
Ox0
ShMt
0
0
M. BATH
h 811
49
37
0
0
Ox 0
ShMt
0
0
MASTE2BATH
In 595
43
27
0
0
OxO
ShMt
0
0
Room7
C 2167
92
98
0
0
OX O
ShMt
0
0
wrl
C 214
3
10
0
0
0x0
ShMt
0
0
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(Cirri)
Clg
(Cfm)
TEL
(It)
Design
FR
Veloc
(fpm)
Diam
(in)
HxW
(in)
Stud/Joist
Opening (in)
Duct
Mat
Trunk
rb1
0x0
1160
1160
0
0
0
0
Ox 0
ShMt
'Fp' WrighlsoR' 2021-Jan1213:18:19
r soot, Riga-SWF&Uriversel 201919,021 RSU08101 Pagel
_Dla rtslWdgHsoRHVACIWYNNE-THEWINDSOR� CaIc=MI8 Fror DoorfacesN