Loading...
HomeMy WebLinkAboutEngineering E1NG0 E1_r_—RNQ) Design Wind Pressure(PMAX+, PMAX-): Ewa EF r�' h560 ft. h>60 ft: . CORPORATE OFFICE: Max Positive Pressure(PMAX+) PMAX+ = gh(6c GCppos+ GCpi) PMAX+ = gh(9e GCppos + GCpi) 160 SW 12th AVE, SUITE 106 DEERFIELD BEACH, FL 33442 Max Negative Pressure(PMAx-) PMAx-= gh(9c GCpneg-GCpi) PMAx-= gh(Ac GCpneg-GCpi) (954) 354-0660 1 (866)396-9999 TENGINEEI INGE PRIES .CO M Device Calculations:ASCE 7-16, Chapter30,All Subsections ENGINEERINGEXPRESS.COM Wind Load Calculation Size Elevation Area AreaT Pmax+.' Pmax- # Zone K= q= "GCP+ GCp- ASCE7-16Ch30 Wind Loads-Components&Cladding (W x H) (ft) (ft2) (ft2) (lb/ft2) (lb/ft2) 7th Edition(2020)Florida Building Code 3 204 x 94 I nt 7 133.17 96.33 0.70 44.06 0.7 -0.8 1 26.2 -37.8 Site Information File Como, owner: EDWARD L PARKER Wind Speed(vut.T): 170 MPH REVIEWED FOR�+COMPLIANCE Exposure Category: B CODE COMPL9ANCE Velocity Pressure Coef.(Kh): 1.04 ST. LUCIE COUNTY Directionality Factor(Kd): 0.85 ®�� Topographical Factor(Kzr): 1.0 Structure Information M e.ow* 't0 e Zone Risk Category: II Building Classification: Enclosed Int.Pressure Coef.(GCpi): 0.18 Mean Roof Height(h): 120 ft. Roof Slope(0): Flat �, 1 Roof Slope Coefficient(9c): 0.9 Min.Building Dim.(L): 75 ft. End Zone Distance(a): 7.5 ft. Prepared In accordance with:ASCE7-I6. 1. HNNON °mHEowRSD sFERm� EALmTION PNY NAS SE VIDED By Richard Neet, P.E.[FL PE 86488]OTERSCERRTFEATTUNHERESEDORMLoFFERnsTOTHVDoRAICABLrrYOPROFOSMSYSfFMORCOMMPPOENTTUnuoGWffHTH PSESSRE.ALLPRODUCTSSHALLSENSTALLMNURCTALCORDMCEWRHVADFORDAPRODUCTAROVALSMDMUSTMEUTHEMPRESSURESFORTEGMNSMECh30.Wind Loads-Components&Cladding 7th Edition(2020)Florida Building Code 2.NOCEATFDATDNORREVEWSOFFMEDTHATTHEMOPOSEDUNRSMEETANYEGRESSREOUMEMENTSALLEORESSSSUESMETOSEMDRESSEDBYTHEPEIMTrMOCONTRACTOR AND THELOCAL SULONG OFFC VL. _ Design Pressure ASD(allowable stress design) S BYANElGNEEAUOPRECORDEOR)TTHECONTRUACTOP.BULDNGOFFrKSHALLVF THATTHE�BSmATERTOSEDDUNNDOWORKESOUNDrONNSTALLANN FTHESMTFM YSTB&F Wind VelocityIs V ultimate DEFCIENCESMEFOUND INTHEExSTNGHOSTSTRUCTURETHSENGNEER OR THEEOR SHALLSENOTFED B60RECONTNUNGCONSMUCTDN AND RESERVESTHEFUGHTTO RE OLT(ultimate) NSPECTMDREEVALUATEDESIGN.NOWMRANTY,Em1EAE ESSEDORMFLED,SCONTANEDHMM. VASD=S rt O.6*VOLT 4.DMENSIGNSMESHOWN TOLLUSTRATEDESIGN FORCESAND OTHER DESIGN ORITBRLATHEYMAYVMYSLIGHTLY.MO EEXrEITTHATTHEOF NGMR ENOTS LM THAN 5%OF 9 ( ) THEENGNEiRED OESIGN.CONTRACTOR ETDVERFYALL FIELD DMENSIONSPRDR TO INSTALLATION. 1 5.MONEER SEALMFD®HERETO VALDATESSMUCTURALDESDNASSHOWN ONLY.USEOFTHSSPECFCATDN BYCONTRACMR,etaLNDEMNFES&MVESHMMLESSTHSBRGNEMR FOR �- © eS 2021E-Tern I ALLCOST&DAMAOM`N LUDNGLEGALFES&APPBLATEFE3SRFSULTNGFROMMATBAIFABRCATDN,SYSFhHECTCN,eCONSTRUCTDNPRACTCESBEYONDTHATWHCHE p .COm CALLED FOR SYLOCAL,STATEBFEDM&CODES&FROMDEVMTIDNSOFT ORM. \ S.ENGNEERNGF ESSHMNOTVSREDTHSJOBSfENFORMATCNCONTANEDHERL3d SBASEDONCONTRACMRSUPPLEDOATAANDMEASURWEnSBJGNEERNGFJDRESSSHALL ID:allamericanwpb-P8899 NOT BEHELD RESPONSELEOR LNBLEN ANYWAYFOR ERRONBDUSOR NACCURATEDATAOR MEASURBAENTSWORKSHALLBEFELD VERIFIED PRIOR TOCONSTRUCTIDN.ENGNEERNG ExPRESSSHALL BENOTFED AND GMEN/N OPPORTUNITYTO RE-EVALUATEOUR WORKUPON DSCOVERYOFANYNACCURATENFORMATDN PRIOR TO MODFCATDN OFE WTNG FIELD CONDMONSANDFABRIC N/NDNSTALLATCNOFMATERIAS Cert of'Aut[I 1i3005;WISH ENGINEER SEAL 07/13/2021 Page 1 of 1 7.IXCE ASEIP M%YPROVDEDHEREN.NOMDrMNALCERTFCATDNSRWMMATDNSMENTMDM. VALID FOR(1)JOB ONLY •ALTERATIONS ADDTtONS,OR OTHER MARKNGSTOTHED000MENTARENOTPBRWrrED AND NVALDATEOUR CEITFCATDN LEVI NSO N B U jLT0'P-';" ©aMN ALL-AMERICAN STORM IDEFENSE !R R T T R R f L O L A f Property Information Building Information Owner: EDWARD L PARKER Wind Zone: 170 MPH. Address: 10044 S OCEAN DR#808 Exposure Category: B JENSEN BEACH,FL 34957 Minimum Building Dimension: 75 ft. Mean Roof Height: 120 ftL— . Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive JL�ax�se ive Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) essf) ILIF 1 Int 7 0.0 0.0 2 Int 7 0.0 0.0 3 Int 204 94 7 26.2 -37.8 Prepared in accordance with:ASCE 7-16,Chapter 30. Wind Loads-Components and Cladding. 7th Edition(2020)Florida Building Code. Page 1 of 1 Identification Schedule for Opening Protective Device or System (The following minimum information shall be provided to facilitate plan review and inspection of the proposed installation,opening,protective device or system) Address: 10044 S OCEAN DR# 808, JENSEN BEACH, FL 34957 Type of Structure: PERMIT#: Dev. Device Device Opening Opening Shutter Shutter #Storm Anchor Header # Type Manufacturer Approval Width Height Width Height Bars Re . Spacing Reinf.Re 1. NOT COVERED NOT COVERED No. 2. NOT 'COVERED NOT COVERED No 3. Accordion Town & Country FBC 13757 189 94 204 94 N/A 12 No rr� NZ