HomeMy WebLinkAboutAPPROVED, engineer 10044_s_ocean_drive_digitally_signed_report.pdf DATE: 7/13/21 JOB ORDER #: 21-4182 CLIENT: Onshore Roofing ADDRESS: 4401 S.E. Commerce Avenue Stuart, Florida 34997 PROJECT: Seawinds Condo. Pool Clubhouse SnapMax Aluminum Roof Panels ADDRESS: 10044 S. Ocean Drive Jensen Beach, FL 2020 FBC/ASCE 7-16 DESIGN PRESSURE CALCULATIONS Project Information: Mean Roof Heights = 12' Exposure: D Basic/Ultimate Wind Speed: Vult=170 mph Length = 30' Category: II Nominal Wind Speed: Vasd=Vult*√0.6 Width = 20' Slope: 6/12 = 26.6° (asd = allowable strength design) Hip Roof For multiple deck condition, the most conservative dimensions were utilized for design calcs. Width of Pressure Coefficient: 0.1(20') = 2.0' or 0.4(12') = 4.8' } use: 3'0" Proposed Roof Replacement Load Table Per Product Approval Roof Zones for Generic Bld. Per Product Approval Page 2, 7/13/21; Job Order # 21-4182 Onshore Roofing - SnapMax Aluminum Roof Panels Seawinds Condo. Pool Clubhouse 10044 S. Ocean Drive; Jensen Beach, FL: Attachment Requirements: Based on the requirements of Florida Product Approval # FL25621.08-R1, Load Table for Structures in Exposure D, Hip Roofs with Max. Slope of 12/12 and Max. Mean Roof Height of 30', with Maximum Design Pressure of -175PSF; the following are the recommended fastening method to attach the Extreme Metal Fabricators' Snap Max Roof Panels to the minimum 15/32" plywood or 3/4" thick wood plank deck: Roof Zones Zone 1 (1 & 1') Zone 2 (2e, 2r, & 2n) Zone 3 (3e and 3r) Max. Design Pressure -175psf -175psf -175psf Attachment Method A A A Fastener #10 x 1" Fasteners #10 x 1" Fasteners #10 x 1" Fasteners Fastener Spacing 6" o.c. along nail strip 6" o.c. along nail strip 6" o.c. along nail strip Method A – Per Product Approval Notes: • Corners and perimeter (edge, hip, & ridge) area dimension shall not be less than a = 3'0" (Zone 2: Perimeter is a 3'0" wide strip, Zone 3: Corners are 3'0" x 3'0") • Our engineering attachment analysis is limited to uplift resistance only, therefore, it does t0 include waterproofing or aesthetic concerns as applicable. • Contractor to verify that the fastening patterns meet manufacturer’s requirements for issuance of a warranty (as applicable). • All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2020 Edition. • Wind load calculations based on ASCE 7-16, 2020 FBC, and information provided by client. Client is responsible for verifying existing/proposed conditions/decks as it pertains to the above provided product approval. • All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Sincerely, ______________________________ Reza Javidan, P.E. Florida Engineering & Testing, Inc. Florida Reg. No. 60223 Certificate of Authorization No. 6923