Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ASPHALT SHINGLESBCIS Home 1 Log In i User Registration ; Not Topics Submit Surcharge '� stats & Facts Publications Contact Us 1 BCIS Site Map 1 Links j search Product Approval dj*r -USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL10124-R29 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany, NJ 07054 (800)766-3411 mstieh@gaf.com Authorized Signature Robert Nleminen Ireith@nemoetc.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054 (800) 766-3411 TechnicalQuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nleminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/16/2022 Validated By John W. Knezevich, PE Validation Checklist Hardcopy Received Certificate of Independence FL10124 R29 COI 2020 01 COI NIEMINEN pdf Referenced Standard and Year (of Standard) Standard year ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2019 TAS 107 2020 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/21/2020 Date Validated 12/21/2020 Date Pending FBC Approval 12/26/2020 Date Approved 02/09/2021 Date Revised 06/04/2021 Summary of Products FL* 10124,1 _ Model, Number or Name GAF Asphalt Roof Shingles Description Fiberglass reinforced 3-tab, laminated, 5-tab and hip/ridge I asphalt shingles Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER, Section S. Installation Instructions FL10124 R29 II 2020 12 21 FINAL ER GAF ASPHALT { SHINGLES FL10124-R29.pdf Verified By: Robert Nieminen PE-59166 j Created by Independent Third Party: yes ((( Evaluation Reports FL10124 R29 AE 2020 12 21 FINAL ER GAF ASPHALT SHINGLES FL10124-R29.pddf Created by Independent Third Party: Yes Contact Us :: 2§01 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. CConyd 2067-20i3 State of Florida :: Privaev Statement :: Accessibiltty_Statement :: Refund Statement Under Florida law, email addresses arepublicrecords. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(i), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may beused for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the Public. To determine if you area licensee under Chapter 455, F.S., please dick here . Product. Approval Accepts; Crediti Safe F securitV IETRICS' NEW I etc. UN Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT GAF Evaluation Report 01506.01.08-R31 1 Campus Drive NJ Parsippany, 11 FL20124-R29 (800) 766-3407054 Date of Issuance: 01/03/2008 Revision 31:12/21/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 71h Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPUANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: ttr�sccirraa, -- .t;tJ.`•• :h ?ti i'a.�.saZE Robert J.M. Nieminen, P.E. = :ti- '"R � .c r=`•^ � The facsimile seal appearing y fi • �; ppearin was authorized b Robert Florida Registration No. 59166, Florida DCA ANE1983 r`'�°�� "� s9 Nieminen, P.E. on 12 21/2020, This does not serve as an CERTIFICATION Of INDEPENDENCE"electronically signed document. 1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018 NEMO ETC, LLC ONEMO I etc ROOFING SYSTEMS EVALUATION: SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the 71h Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein Sp+•DR. Section Pro a Standard Year 1507.2.4, R905.2.3 Material standard ASTM D1970 2015 1507.2.5, R905.2.4 Material standard ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2019 1507.2.7.1, R905.2.6.1 3. REFERENCES: Wind Resistance TAS 107 2020 Entity Examination Reference 777=zy pate PRI (TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI (TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI (TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI (TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI (TST 5878) ASTM D1970 (QuickStart) GAF-340-02-01 03/13/2012 PRI (TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 PRI (TST 5878) Wind Driven Rain GAF-895-02-01 11/2012018 PRI (TST 5878) Wind Driven Rain GAF-896-02-01 11/20/2018 PRI (TST 5878) ASTM D3462 GAF-897-02-01 11/08/2018 PRI (TST 5878) ASTM D3462 GAF-898-02-01 11/08/2018 PRI (TST 5878) ASTM D3462 GAF-899-02-01 11/15/2018 UL (TST 1740) ASTM D3462 93NK6295 11/29/1993 UL (TST 1740) ASTM D3462 99NK43835 01/12/2000 UL (TST 1740) TAS 107 94NK9632 03/29/2000 UL (TST 1740) ASTM D3462 01NK06632 02/02/2001 UL (TST 1740) ASTM D3161, TAS 107 01NK9226 05/21/2001 UL (TST 1740) ASTM D3161 01NK37122 12/18/2001 UL (TST 1740) ASTM D3462 01NK37122 12/19/2001 UL (TST 1740) ASTM D3161, TAS 107 02NK12980 04/10/2002 UL (TST 1740) ASTM D3161, TAS 107 02NK30871 09/09/2002 UL (TST 1740) ASTM D3161 03CA5367 03/11/2003 UL (TST 1740) ASTM D3462 03NK26444 10/17/2003 UL (TST 1740) ASTM D3462 04NK13850 06/07/2004 UL (TST 1740) ASTM D3161 04NK13850 06/23/2004 UL (TST 1740) ASTM D3161 04NK30546 03/10/2005 UL (TST 1740) ASTM D3462 04NK22009 05/06/2005 UL (TST 1740) ASTM D3161 04NK22009 05/09/2005 UL (TST 1740) ASTM 03462 05NK27924 02/10/2006 UL (TST 1740) ASTM D3161 05NK27924 02/11/2006 UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL (TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006 UL (TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL (TST 1740) ASTM D3462 06CA31603 12/01/2006 UL (TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006 UL (TST 1740) ASTM D3161 07NK05228 03/13/2007 NEMO ETC, LLC Evaluation Report 01506.01.08-1131 Certificate ofAuthorization #32455 7TH EDITION (2020) FBC NON-HVH2 EVALUATION F1.10124-1129 GAF Asphalt Roof Shingles Revision 31: 12/21/2020 Page 2 of 8 TABLE 1; ASPHALT SHINGLE COMPONENTS NNEMO etc. Type Product Description Material Standard Plant(s) color -coordinated starter strips for use with StarterMatch" Starter Strip Grand Canyon" and Grand Sequoia" series Shingles asphalt shingles. StarterMatch" are installed ASTM D3462 CA-F Accessory as the second starter for Grand Canyon" and Starter Grand Sequoia® series installations Strips WeatherBlockerT"' Premium Starter Strip Shingles (fka, WeatherBlocker- Premium starter strips for asphalt roof shingles ASTM D3462 IN-MV Eave/Rake Starter Strip Shingles) Marquis WeatherMax" IN-MV *FortitudeQD eign" fiberglass reinforced 3-tab asphalt roof AL, CA-F, FL, GA, IN- _ shingles ASTM D3462 MV, PA, TX-D GA, IN-MV, TX_-D IN-MV Glenwood" PA WCanyon"anyon" IN-MV equoia" CA-F, IN-MV equoia" IR CA-F, IN-MV equoia" ArmorShield" CA-F, IN-MV quoia" AS CA-F ne" American Harvest" CA-F ne" AH AL, CA-F, iN-MC, PA ne" ArmorShield" 11 AL, CA-F, IN -MC, PA merine" AS it TX-E Timberline" Cool Series TX-E Asphalt Timberline" CS CA-F Shingles fiberglass reinforced, laminated asphalt CA-F Timberline HD" roof shingles ASTM D3462 AL, CA-S, CA-F, FL, IN - MC, MD, MN, PA, TX- D, TX-E Timberline" HDZT1 AL, CA-F, CA-S, FL, IN - MC, MD, MN, PA, TX- D, TX-E Timberline" Natural Shadow" AL, CA-S, IN -MC, MD, MN, PA, TX-D, TX-E Timberline" NS AL, CA-S, FL, IN -MC, MD, MN, PA, TX-D, TX- )' Timberline Ultra HD" AL, CA-S, IN -MC, PA, TX-E Timberline" UHD AL, CA-S, IN -MC, PA, Woodland" TX-E IN-MV SlatelineT" fiberglass reinforced 5-tab asphalt roof shingle ASTM D3462 IN-MV Seal -A -Ridge" ArmorShield" Hip & Seal -A -Ridge" AS GA Ridge Seal -A -Ridge® Ridge Cap Shingles fiberglass reinforced, hip and ridge GA Shingles Timbertex" Premium Ridge Cap asphalt roof shingles ASTM D3462 GA Shingles IN-MV NEW ETC, LLC Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION GAF Asphalt Roof Shingles Evaluation Report 01506.01.08-R31 FL10124-R29 Revision 31: 12/21/2020 Page 4 of 8 (NNEMOJetc. 5.1 This is a building code evaluation. Neither MEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES Product FBC Table 1507.2.7.1 or R905.2.6.1 Marquis WeatherMax" ASTM D3161(F) & ASTM D7158(H) Royal Sovereign" ASTM D3161(F) & ASTM D7158(H) Sentinel" ASTM D3161(F) & ASTM D7158(H) Camelot" 11 ASTM D3161(F) & ASTM D7158(H) Fortitude® ASTM D3161(F) & ASTM D7158(H) Glenwood® ASTM D3161(F) & ASTM D7158(H) Grand Canyons ASTM D3161(F) & ASTM D7158(H) Grand Sequoia" ASTM D3161(F) & ASTM D7158(H) Grand Sequoia® IR ASTM D3161(F) & ASTM D7158(H) Grand Sequoia® ArmorShieid" ASTM D3161(F) & ASTM D7158(H) Grand Sequoia" AS ASTM D3161(F) & ASTM D7158(H) Timberline" American Harvests ASTM D3161(F) & ASTM D7158(H) Timberline® AH ASTM D3161(F) & ASTM D7158(H) Timberline® ArmorShieid® II ASTM D3161(F) & ASTM D7158(H) Timberline" AS II ASTM D3161(F) & ASTM D7158(H) Timberline® Cool Series ASTM D3161(F) & ASTM D7158(H) Timberline® CS ASTM D3161(F) & ASTM D7158(H) Timberline HD" ASTM D3161(F) & ASTM D7158(H) Timberline® HDZTM ASTM D3161(F) & ASTM D7158(H) Ttmberlinee Natural Shadow" ASTM D3161(F) & ASTM D7158(H) Timberline® NS ASTM D3161(F) & ASTM D7158(H) Timberline Ultra HD" ASTM D3161(F) & ASTM D7158(H) Timberline" UHD ASTM D3161(F) & ASTM D7158(H) Woodland" ASTM D3161(F) & ASTM D7158(H) Slateline TI ASTM D3161(F) & ASTM D7158(H) 5.5.1 Classification by ASTM D7158: ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. MEMO ETC, LLC Evaluation Report 01506.01.0E-R31 Certificote ofAuthorizotion #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10124R29 GAF Asphalt Roof Shingles Revision 31:12/21/2020 Page 5 of 8 V TABLE 2B: WIND CLASSIFICATIONS, STARTER STRIPS AND HIP & RIDGE Type Product a FBC Table 1507.2.7.1 or R905.2.6.1 Pro -Start® Starter Strip Shingles (fka, Pro-Starto Eave/Rake Starter Strips Starter Strip Shingles) ASTM D3161, Class F WeatherBlockerW Premium Starter Strip Shingles (fka, WeatherBlockerT"" Premium Eave/Rake Starter Strip Shingles) ASTM D3161, Class F Seal -A -Ridge® ArmorShield® ASTiVI D3161, Class F Hip & Ridge Seat -A -Ridge® AS ASTM D3161, Class F Shingles Seal -A -Ridge® Ridge Cap Shingles ASTM D3161, Class F Timbertex° Premium Ridge Cap Shingles ASTM D3161, Class F (sealant required, See Section 6) 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report, 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 GAF asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and GAF published installation instructions. 6.2 STARTER SHINGLES OR STARTER STRIP: 6.2.1 Installation of Pro -Start® Starter Strip Shingles (fka, Pro -Start® Eave/Rake Starter Strip Shingles), WeatherBlockerT" Premium Starter Strip Shingles (fka, WeatherBiockerT"I Premium Eave/Rake Starter Strip Shingles) and QuickStartO Peel & Stick Starter Roll shall comply with the GAF current published instructions. 6.3 AspmALTSHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1S07.2.7 or R905.2.6, with the following exceptions: ➢ Camelot® 11, Grand Canyon', Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShieid', and Woodland® require minimum five (5) nails per shingle. ➢ Slatelinel requires minimum six (6) nails per shingle. NEIVIO ETC, LLC Certifrrnte ofAtithorization #32455 rN Evaluation Report 01506.01.08-R31 7 EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R29 GAF Asphalt Roof Shingles Revision 31: 12/21/2020 Page 6 of 8 ONEMO I etc® 6.3.2 Fastening for Fortitiirips Timharlina® AW 39-3/8" (1m) 14.9B' (295mm - 372mm) 11-50-14-5lg' 1295mm - 372mm) V2'- 2-W 03mm - @4mm1 1,2-2-112' (13mm -94mm) f8'1/4^ tr TARGET NAIL ZONE ZONA OBJETIVO DE CLAVADO 6 7/8" s tsrls°-?-sre° I1asmR - isammp amm> 1 STANDARD NAILING PATTERN: Nail shingles approximately 6 7/8' (174 mm) from bottom of shingle, in nailing area, as shown. Nails must not be exposed. Not for use on Mansard roofs (21:12 slope and above). o.5.:5 wnere tne root slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required, Contact the GAF for details. FasteningfnrFnrtitnrfaQb TimharH-4DAu-r:....L__:__� 6.4 Hip & RIDGE SHINGLES: 6.4.1 Installation of Seal -A -Ridge® Ridge Cap Shingles shall comply with the GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter located 6-7/8- inch back from the exposed end and 0.5-inch from the edge. Claw Clouer NEMO ETC, LLC Evaluation Report 01506.o1.o8-R31 Certificote ofAuthorirotion #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10124•R23 GAF Asphalt Roof Shingles Revision 31:12121/2020 Page 7 of 8 6.4.2 Installation of Seal -A -Ridge® ArmorShield® and Seal -A -Ridge® AS shall comply with the GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle located 5.25-inch back -from the exposed end and 1-inch from the edge. 6.4.3 Installation of TimbertexO Premium Ridge Cap Shingles shall comply with GAF current Published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads ofSonneborn "NP1 Gun Grade Polyurethane Sealant" or Henkel "PL Roofing and Flashing Sealant, , UN i I etc, t; (292 mtn) Sealant i" (25 Min) Sellante mm) Enduit d'etancheitds .r s Nail Ciavo t2" Clouer (305 mm) g,. (229 min) 12° (305 MM) As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product, Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 611320.3 QA requirements, Refer to Section 4 herein for products and production locations having met codified material standards. UL LLC— QUA9625; (414) 248-6409; karen.buchmann ul com - END OF EVALUATION REPORT - NEMO ETC, LLC certificate ofAutharizatian #32455 7T" EDITION (2020) FBC NON-HVHZ EVAWATION Evaluation Report 01506.01.08•R31 GAF Asphalt Roof Shingles FL10124-1129 Revision 31:12/21/2020 Page 8 of 8