HomeMy WebLinkAboutGate Operator DetailGENERAL NOTES: 1) DESIGN AND CONSTRUCTION SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: - FLORIDA BUILDING CODE (FBC) 7TH EDITION (2020) - ASCE 7-16 - THE 2015 ALUMINUM DESIGN MANUAL - DESIGN WIND PRESSURES DERIVED FROM ASCE 7-16 AND PER FBC SECTION 1609 - ULTIMATE WIND SPEED: 170 MPH - RISK CATEGORY: II - EXPOSURE CATEGORY: D - ASTM F2200: STANDARD SPECIFICATION FOR AUTOMATED VEHICULAR GATE CONSTRUCTION. 2) EXPANSION BOLTS SHALL BE GALVANIZED HILTI KWIK BOLTS OR APPROVED EQUAL W/ 4-1/2- MINIMUM EMBED 3) INSULATE ALUMINUM MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. 4) CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3.000 PSI AFTER 28 DAYS. 5) SOIL BEARING CAPACITY FOR FOUNDATIONS: EXISTING, ASSUMED TO BE WELL COMPACTED AT 2,000 PSF 6) FOOTING HAS BEEN DESIGNED PER FBC 1819.7. 7) ENGINEER HAS NOT VISITED THE JOB SITE AND SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANYWAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS THAT HAVE BEEN PROVIDED BY THE CONTRACTOR. WORK SHALL BE FIELD VERIFIED BY THE CONTRACTOR AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. MINIMUM (4) 1/2"0 GLAV. EXPANSION ANCHOR W/ 4-1/2" EMBED EXIST. G t2" 3,000 PSI CONC: 2 �v5'03p7 FOOTING REVIEWED FOR CODE COMPLIANCE ST. L.UCIE COUNTY socc DATE: 06/10/2021 DSGN: E. KENNEDY IKENNEDY DRWN: E. KENNEDY ENGINEERING, LLC 332 SW 7TH TERRACE CHKD: E. KENNEDY BOCA RATON, FL 33486 SCALE: N.T.S. CA / 29980 �j 0 1 PH: (561) 573-1679 DWG. No. of EWAII: evankennedylOgmall.com MEGA ARM GATE OPERATOR _ I ATE ARM (12' MAX LENGTH) •dam • I A A e e a a °A 24" MIN. A O e.. G a' .a d MIN. 24" X 24" MaNAL91,120 L (� -g THIS REM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY EVAN KENNEDY. L :{pl -. ;01 P.E.ON 06-16Q1 USING A DIGITAL SIGNATURE V PRINTEDCOPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND - SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. No 69895 TLANTIS B Y THE SEA ST�T 2F REMOTE ACCESS MEGA ARM GATE OPERATOR � SALES HF/ CONCRETE PAD v e) jusvw-) 1) DESIGN AND CONSTRUCTION SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: - FLORIDA BUILDING CODE (FBC) 7TH EDITION (2020). - ASCE 7-16 - THE ALUMINUM DESIGN MANUAL, 2015 EDITION. - DESIGN WIND PRESSURES DERIVED FROM ASCE 7-16 AND PER FBC SECTION 1609 - ULTIMATE WIND SPEED: 170 MPH - RISK CATEGORY: II - EXPOSURE CATEGORY: D 2) ALUMINUM MATERIAL SHEET METAL IS 5D52-H32 UNDER ASTM B209, EXTRUSIONS ARE 6063-T5 UNDER ASTM 8221, STRUCTURAL IS 6061-T6 UNDER ASTM B211 WITH FIY=35KSI AND FTU=38KSI, UNLESS OTHERWISE STATED. ALUMINUM WELDS WILL USE 5356 ALLOY WITH MINIMUM SHEAR STRENGTH OF 17KSL ALL WELDING TO CONFORM TO AWS STANDARDS. ALL BOLTS AND SCREWS IN CONTACT WITH ALUMINUM ARE STAINLESS STEEL A304/A316 GRADE STAINLESS STEEL 3,000 PSI CONC. SEE CAMERA/RFID OPTIONS 3) ALL MEMBERS SHALL BE WELDED W/ MINIMUM 3/16' FILLET WELD, UNLESS NOTED OTHERWISE. ALL WELDING SHALL CONFORM TO AISC STEEL CONSTRUCTION MANUAL 13TH EDITION. 4) INSULATE ALUMINUM MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. 5) CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI AFTER 28 DAYS. 6) SOIL BEARING CAPACITY FOR FOUNDATIONS: EXISTING, ASSUMED TO BE WELL COMPACTED AT 2000 PSF 7) ENGINEER HAS NOT VISITED THE JOB SITE AND SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANYWAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS THAT HAVE BEEN PROVIDED BY THE CONTRACTOR. WORK SHALL BE FIELD VERIFIED BY THE CONTRACTOR AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 210 5 `�3 REVIEWED F R CODE COMPLIANCE ST• LUCIE COUNTY SOCC Recram" Permitting pepad"'Ont St. Lucte County 4°X4'XO.125' ALUM. POST e z A G n mom 12' DIAL MIN. FINISH GRADE CAMERA/RFID POLE SEQM11;:.KENiji'' SCALE: N.T.S. �� •�••�� C E N S -: •N No 69895 CAMERA *4EEP CAMERA DETAIL SCALE: N.T.S. IA"'X6' ALUM. PLATE UU/ I° THRU BOLTS TO POLE 3'X3'XO.125' ALUM. TUBE 2'0 X 0.125' ALUM. TUBE RFID READER MAX. 2 SF EFFECTIVE WIND AREA ATTACHED TO POLE RFID DETAIL SCALE: N.T.S. �MOV aK,88,r8D00311000NfEc. Evan Kennel i THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY EVAN KENNEDY. P.E. ON 06•10-21 USINGA DIGITAL SIGNATURE PRINTED COPIES OF TMS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. DATE: 06/10/2021 DSGN: E. KENNEDY �■ : ,� • : hLAiVTIS BY THE SEA L�%IKENNEDY DRWN: E KENNEDY E. KENNEDY ENGINEERING, NG, LLC . • • • 3N TERRACE i� : STET QF CHKD: SCALE: N.T.S. _ BO RCA AT ON, FL 33486 j S UOO-- 2ll i CA 0 29900 �j� p•0 REMOTE ACCESS CAMERA/RFID c 1 PH: (561) 573-1679 s SALES POLE DETAIL S�.SY���� c DWG. No. of EMAIL evenkennedylOgman.com �� RECEIVED MAY 11 2021 r1qrMittiz,,g Department St. Lucie County ATLANTIS SOUTH GATE ENTRY SYSTEM Proposed gate entry motors (typical of 2) 24v/dc fractional HP 4 Existing 125v/20a x branch circuit