HomeMy WebLinkAboutEnergy Code-70
FORM R405-2020 7- C ®- 0 Lf
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 3407 Bent Pine Drive
Builder Name: Zabitosky Construction
Street: 3407 Bent Pine Drive
Permit Office:
City, State, Zip: Ft. Pierce, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie(Florida Climate Zone 2)
1. New construction or existing New (From Plans)
10. Wall Types(200.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior R=4.1 200.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 1
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types(153.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 153.00 ftZ
6. Conditioned floor area above grade (ftZ) 153
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(30.0 sqft.) Description Area
12. Ducts, location & insulation level R ft2
a. U-Factor: Dbl, U=0.33 30.00 ft2
a. a. Sup: Attic, Ret: Attic, AH:
Garage 6 31
SHGC: SHGC=0.22
b.
b. U-Factor: N/A ft2
C.
SHGC:
13. Cooling Systems
kBtu/hr Efficiency
c. U-Factor: N/A ft2
a. Central Unit
45.0 SEER:14.00
SHGC:
Area Weighted Average Overhang Depth: 0.000 ft
Area Weighted Average SHGC: 0.220
14. Heating Systems
kBtu/hr Efficiency
8. Skylights Description Area
a. Electric Strip Heat
34.1 COP:1.00
U-Factor:(AVG) N/A N/A ft2
SHGC(AVG): N/A
15. Hot Water Systems
9. Floor Types Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R= 0.0 152.30 ft2
EF: 0.950
b. N/A R= ft2
b. Conservation features
c. N/A R= ft2
None
16. Credits
CF, CV
Glass/Floor Area: 0.196 Total Proposed Modified Loads: 12.53
PASS
Total Baseline
Loads: 13.67
hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
pSeZ UE Sr`t?t�
Code.
calculation indicates compliance
/
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
this building will be inspected for"+
r - re i1
lr" ".,..
DATE: Jute 11, 2021
compliance with Section 553.908
l
hereby certify that this building, as designed, is in compliance
Florida Statutes.
*
we
with the Florida Energy Code.
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct
leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 Qn for whole house.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
6/11/2021 1:29:19 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) om i t S re
�� P • hs:u�' e? r4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: 3407 Bent Pine Drive
Address type:
Street Address
Building Type: User
Bedrooms: 1
Lot #:
--
Owner:
Conditioned Area: 153
Block/SubDivision: —
Total Stories: 1
PlatBook:
—
Builder Name: Zabitosky Construction
Worst Case: No
Street:
3407 Bent Pine Drive
Permit Office:
Rotate Angle: 0
County:
St. Lucie
Jurisdiction:
Cross Ventilation: Yes
City, State, Zip:
Ft. Pierce,
Family Type: Detached
Whole House Fan: No
FL,
New/Existing: New (From Plans)
Terrain: Suburban
Year Construct:
Shielding: Suburban
Comment:
CLIMATE
Design
Design Temp
Int Design Temp
Heating
Design
Daily temp
Location
Tmy Site
97.5% 2.5%
Winter Summer
Degree Days
Moisture
Range
_ FL, ST—LUCIE_CO_INTL FL VERO—BEACH_MUNICIPA 39 90
70 75
299
58
Medium
BLOCKS
Number Name
Area
Volume
1 Entire House
153
1224
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms
Finished
Cooled
Heated
_ 1 Bedroom
135
1080 No 0
1
Yes
Yes
Yes
2 clst
18
140 No 0
Yes
Yes
Yes
FLOORS
(Total Exposed Area = 152 sq.ft.)
# Floor Type
Space
Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value
Tile Wood Carpet
_ 1 Slab -On -Grade Edge Ins
Bedroom
22.5
134.8 ft 0.710
—
1.00
0.00 0.00
2 Slab -On -Grade Edge Ins
clst
2.5
17.5 ft 0.710
—
1.00
0.00 0.00
ROOF
Roof Gable Roof
Rad Solar
SA Emitt
Emitt
Deck Pitch
✓# Type
Materials
Area Area Color
Barr Absor.
Tested
Tested
Insul. (deg)
1 Gable or Shed
Metal
160 ft2 26 ft2 Light
N 0.55
No 0.9
No
0 18.43
ATTIC
# Type
Ventilation
Vent Ratio (1 in)
Area RBS
IRCC
1 Full attic
Vented
300
152 ft2 N
N
6/11/2021 1:29:19 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
(Total Exposed Area = 153 sq.ft.)
#
Ceiling Type
Space R-Value Ins. Type
Area U-Factor Framing Frac. Truss Type
_ 1
2
Under Attic(Vented)
Under Attic(Vented)
Bedroom 30.0 Blown
clst 30.0 Blown
135.0ft2 0.053 0.10 Wood
18.0ft2 0.053 0.10 Wood
WALLS
(Total Exposed Area = 200 sq.ft.)
VAdjacent
#
Ornt To Wall Type
Cavity Width
Space R-Value Ft In
Height Area U- Sheath Frm. Solar Below
Ft In sq.ft. Factor R-Value Frac. Absor. Grade
-1
_ 2
3
N Exterior Conc. Blk - Int Ins
E Exterior Conc. Blk - Int Ins
N Exterior Conc. Blk - Int Ins
Bedroom 4.1 12.0 0
Bedroom 4.1 10.0 6
Gist 4.1 2.0 6
8.0 0 96.0 0.149 0 0 0.50 0 %
8.0 0 84.0 0.149 0 0 0.50 0 %
8.0 0 20.0 0.149 0 0 0.50 0 %
DOORS
(Total Exposed Area = 0 sq.ft.)
✓#
Ornt Adjacent To Door Type
Space Storms
Width Height
U-Value Ft In Ft In Area
1
N Exterior Wood
Bedroom None
0.20 0.10 0 0.10 0 0.1ft2
WINDOWS
(Total Exposed Area = 30 sq.ft.)
#
Wall --Overhang-
Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening
1 E 2 None Double (Clear) Yes
0.33 0.22 Y N 30.0ft2 0.0 ft 0 in 0.0 ft 0 in None None
INFILTRATION
#
Scope Method SLA
CFM50 ELA EgLA
ACH ACH50 Space(s)
1
Wholehouse Proposed ACH(50) 0.00035 142 7.81 14.66
0.1262 7.0 All
GARAGE
#
Floor Area Roof Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1
383 ft2 383 ft2
64 ft
8 ft 1
MASS
#
Mass Type Area
Thickness
Furniture Fraction Space
_ 1
2
Default(8 Ibs/sq.ft.) 0 ft2
Default(8 Ibs/sq.ft.) 0 ft2
0 ft
0 ft
0.30 Bedroom
0.30 clst
HEATING SYSTEM
#
System Type Subtype
AHRI # Efficiency Capacity --Geothermal HeatPump-- Ducts Block
kBtu/hr Entry Power Volt Current
1
Electric Strip Heat None
COP: 1.00
34.1 0.00 0.00 0.00 sys#1 1
6/11/2021 1:29:19 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype/Speed AHRI # Efficiency
Capacity
Air Flow
SHR
Duct
Block
kBtu/hr
cfm
1 Central Unit
Split/Single SEER:14.0 45.0
0
0.70
sys#1
1
HOT WATER SYSTEM
# System Type
Subtype
Location
EF(UEF) Cap Use
SetPnt
Fixture Flow Pipe Ins.
Pipe length
1 Electric
None
Garage
0.95 (0.93) 40.00 gal 61 gal
120 deg
Standard
None
35
Recirculation
Recirc Control
Loop Branch Pump DWHR
Facilities Equal DWHR
Other Credits
System
Type
length length power
Connected Flow
Eff
1 No
NA NA NA No
NA
NA NA
None
DUCTS
----Supply--
---Return--
Air
CFM 25 CFM 25
HVAC #
VDuct
# Location
R-Value Area Location R-Value Area Leakage Type
Handler
TOT OUT
QN
RLF Heat Cool
1 Attic
6.0 31 ftz
Attic
6.0 8 ftz Default Leakage
Garage
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans: N
Cooling [ ] Jan
[ ] Feb
[ ] Mar
[ ] Apr
[ ] May [X] Jun [X] Jul
[X] Aug
[X] Sep [ ] Oct
[ ]
Nov
[ ] Dec
Heating [X] Jan
[X] Feb
[X] Mar
[ ] Apr
[ ] May [ ] Jun [ ] Jul
[ ] Aug
[ ] Sep [ ] Oct
[X] Nov
[X] Dec
Venting [ ] Jan
[ ] Feb
[X] Mar
[X] Apr
[ ] May (] Jun [ ] Jul
[ ] Aug
[ ] Sep [X] Oct
[X] Nov
[ ] Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3 4 5 6
7
8 9
10
11
12
Cooling (WD)
AM
78
78
78 78 78 78
78
78 80
80
80
80
PM
80
80
80 80 78 78
78
78 78
78
78
78
_ Cooling (WEH)
AM
78
78
78 78 78 78
78
78 80
80
80
80
PM
80
80
80 80 78 78
78
78 78
78
78
78
_ Heating (WD)
AM
65
65
65 65 65 65
65
68 68
68
68
68
PM
68
68
68 68 68 68
68
68 68
68
68
68
_ Heating (WEH)
AM
65
65
65 65 65 65
65
68 68
68
68
68
PM
68
68
68 68 68 68
68
68 68
68
68
68
6/11/2021 1:29:19 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4