Loading...
HomeMy WebLinkAboutEnergy Code-70 FORM R405-2020 7- C ®- 0 Lf FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 3407 Bent Pine Drive Builder Name: Zabitosky Construction Street: 3407 Bent Pine Drive Permit Office: City, State, Zip: Ft. Pierce, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 10. Wall Types(200.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 200.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 1 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types(153.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 153.00 ftZ 6. Conditioned floor area above grade (ftZ) 153 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(30.0 sqft.) Description Area 12. Ducts, location & insulation level R ft2 a. U-Factor: Dbl, U=0.33 30.00 ft2 a. a. Sup: Attic, Ret: Attic, AH: Garage 6 31 SHGC: SHGC=0.22 b. b. U-Factor: N/A ft2 C. SHGC: 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 45.0 SEER:14.00 SHGC: Area Weighted Average Overhang Depth: 0.000 ft Area Weighted Average SHGC: 0.220 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Strip Heat 34.1 COP:1.00 U-Factor:(AVG) N/A N/A ft2 SHGC(AVG): N/A 15. Hot Water Systems 9. Floor Types Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R= 0.0 152.30 ft2 EF: 0.950 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 16. Credits CF, CV Glass/Floor Area: 0.196 Total Proposed Modified Loads: 12.53 PASS Total Baseline Loads: 13.67 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this pSeZ UE Sr`t?t� Code. calculation indicates compliance / with the Florida Energy Code. PREPARED BY: Before construction is completed this building will be inspected for"+ r - re i1 lr" ".,.. DATE: Jute 11, 2021 compliance with Section 553.908 l hereby certify that this building, as designed, is in compliance Florida Statutes. * we with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 Qn for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/11/2021 1:29:19 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) om i t S re �� P • hs:u�' e? r4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 3407 Bent Pine Drive Address type: Street Address Building Type: User Bedrooms: 1 Lot #: -- Owner: Conditioned Area: 153 Block/SubDivision: — Total Stories: 1 PlatBook: — Builder Name: Zabitosky Construction Worst Case: No Street: 3407 Bent Pine Drive Permit Office: Rotate Angle: 0 County: St. Lucie Jurisdiction: Cross Ventilation: Yes City, State, Zip: Ft. Pierce, Family Type: Detached Whole House Fan: No FL, New/Existing: New (From Plans) Terrain: Suburban Year Construct: Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range _ FL, ST—LUCIE_CO_INTL FL VERO—BEACH_MUNICIPA 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Entire House 153 1224 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _ 1 Bedroom 135 1080 No 0 1 Yes Yes Yes 2 clst 18 140 No 0 Yes Yes Yes FLOORS (Total Exposed Area = 152 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Ins Bedroom 22.5 134.8 ft 0.710 — 1.00 0.00 0.00 2 Slab -On -Grade Edge Ins clst 2.5 17.5 ft 0.710 — 1.00 0.00 0.00 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch ✓# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 160 ft2 26 ft2 Light N 0.55 No 0.9 No 0 18.43 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 152 ft2 N N 6/11/2021 1:29:19 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING (Total Exposed Area = 153 sq.ft.) # Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac. Truss Type _ 1 2 Under Attic(Vented) Under Attic(Vented) Bedroom 30.0 Blown clst 30.0 Blown 135.0ft2 0.053 0.10 Wood 18.0ft2 0.053 0.10 Wood WALLS (Total Exposed Area = 200 sq.ft.) VAdjacent # Ornt To Wall Type Cavity Width Space R-Value Ft In Height Area U- Sheath Frm. Solar Below Ft In sq.ft. Factor R-Value Frac. Absor. Grade -1 _ 2 3 N Exterior Conc. Blk - Int Ins E Exterior Conc. Blk - Int Ins N Exterior Conc. Blk - Int Ins Bedroom 4.1 12.0 0 Bedroom 4.1 10.0 6 Gist 4.1 2.0 6 8.0 0 96.0 0.149 0 0 0.50 0 % 8.0 0 84.0 0.149 0 0 0.50 0 % 8.0 0 20.0 0.149 0 0 0.50 0 % DOORS (Total Exposed Area = 0 sq.ft.) ✓# Ornt Adjacent To Door Type Space Storms Width Height U-Value Ft In Ft In Area 1 N Exterior Wood Bedroom None 0.20 0.10 0 0.10 0 0.1ft2 WINDOWS (Total Exposed Area = 30 sq.ft.) # Wall --Overhang- Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening 1 E 2 None Double (Clear) Yes 0.33 0.22 Y N 30.0ft2 0.0 ft 0 in 0.0 ft 0 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00035 142 7.81 14.66 0.1262 7.0 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 383 ft2 383 ft2 64 ft 8 ft 1 MASS # Mass Type Area Thickness Furniture Fraction Space _ 1 2 Default(8 Ibs/sq.ft.) 0 ft2 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0 ft 0.30 Bedroom 0.30 clst HEATING SYSTEM # System Type Subtype AHRI # Efficiency Capacity --Geothermal HeatPump-- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Strip Heat None COP: 1.00 34.1 0.00 0.00 0.00 sys#1 1 6/11/2021 1:29:19 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm 1 Central Unit Split/Single SEER:14.0 45.0 0 0.70 sys#1 1 HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length 1 Electric None Garage 0.95 (0.93) 40.00 gal 61 gal 120 deg Standard None 35 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS ----Supply-- ---Return-- Air CFM 25 CFM 25 HVAC # VDuct # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6.0 31 ftz Attic 6.0 8 ftz Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: N Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec Venting [ ] Jan [ ] Feb [X] Mar [X] Apr [ ] May (] Jun [ ] Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 _ Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 _ Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 _ Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 6/11/2021 1:29:19 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4