Loading...
HomeMy WebLinkAbouthealth departmentSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Olianne Reyes AGENT: 011anne Reyes PROPERTY ADDRESS: 401 E Midway Rd Fort Pierce, FL 34982 LOT: 5 & 6 BLOCK: 2 APPLICATION # : AP 1609312 PERMIT #:56-SF-2216207 DOCUMENT #:F11682728 DATE PAID:12/23/2020 FEE PAID.545.00 RECEIPT #:56-PID-4835712 SUBDIVISION: Indian River Estates ID#: 3402-602-0050-000-6 CHECKED [XI ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RUDE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1090.00 [2] [ ] [271 SURFACE WATER 33 FT [ ] [02] TANK MATERIAL Polypropylene [ ] [28] DITCHES FT [ ] [03] OUTLET DEVICE [ ] [29] PRIVATE WELLS FT [ ] [041 MULTI -CHAMBERED [ Y N ] [ ] [30] PUBLIC WELLS FT [ ] (05] OUTLET FILTER PolylokPL-68 [ ] (311 IRRIGATION WELLS FT [ ] [06] LEGEND 1. 70-143-11DC4 2, [ ] [32] POTABLE WATER 35 FT [ ] [071 WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 19 FT [ ] [081 LEVEL [ ] [34] PROPERTY LINES 27 FT [ ] [09] DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 509 [2] SQFT [ ] [36] DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 8.00 2, [ ] [381 SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [39] STABILIZATION 08/20/2021 [ ] [141 DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 6.00 [ ] [40] UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [18] DOSING PUMPS [ ] (421 ALARMS [ ] [191 AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [46] FINAL SITE GRADING [ ] [22] FILL AMOUNT [ ] [47] CONTRACTOR Jason Harris (All About Septi [ ] [23] FILL TEXTURE [ ] [481 OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] (25] AREA REPLACED [ ] [49] TANK PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION I APPROVED / DISAPPROVED ]: 64 St. Lucie CHD Patthew S Vajanyi (Florida Department of He FINAL SYSTEM [ APpROVED / DISAPPROVED ]: / St. Lucie CHD Environmental Sp eci t III Brian J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DR 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP1609312 EID2216207 DATE: 07/02/2021 DATE: nRnn/7n71 Page 2 of 3 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP1609312 PERMIT #:56-SF-2216207 DOCUMENT #:F11682728 DATE PAID.12/23/2020 FEE PAID.545.00 RECEIPT # :56-PI D-4835712 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 400 apd. Vew ST, filter, and 5x6+3x5 long BED DF installed. No violations, system ok to cover. Contractor notified on site. Needs final nspection for mound system, and final site grading. =inal system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1609312 EID2216207