Loading...
HomeMy WebLinkAboutWall Sign PlansINDIVIDUAL INTERNALLY LED ILLUMINATED CHANNEL LETTERS ON RACEWAY AREI y 102 'in 4 c ait I—M, 12.75 S.F. 11 �: �y CRY �f� {C``�.��.-�+,••.��' �J ALLOWABLE SIGN AREA FRONT = 50' X 13' = 650 S.F. 650 X 20 % 130 S. F. SIGN = 12.75 S.F. 13' 2 [0S - 08 34 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY SOCC 50' BUILDING FRONT JOB TITLE CARE NET ADDRESS PSL APPROVED • N �� � 4444 S.E. COMMERCE AVE. Thie dl=, renderino t epeoe ero the exdusNe property of Reminpo NOTE: ALL ARTWORK & COLORS MUST BE SIGNED OFF BEFORE ANY WORK 15 TO BEGIN O APPROVED W/ CHANGES STUART, FL.34997 772.220.7763 Signs And may not beshow=any pereon oroorp. tlon outoWethe dh orgenizetlon. IF EXACT COLORS ARE REQUIRED OR MORE DETAILS PLEASE NOTE. CUSTOMER IS O NOT APPROVED tlamingosigns@aai.com Nrforetweytoberoprpresseinarowey,nsepe oriormwithootlhee:proseedwrlttenooneeM RESPONSIBLE FOR ANY CHANGES ONCE WORK BEGINS. RESUBMIT W/ CHANGES wf" - INDIYIDU,AL. INTEi NALLY; LED; ILL MI;NATED 'CHANNEL LETTER5 ON RACEWAY Letters to be fabricated of .063 aluminum backs «� with .040 black returns. Interior of letters to be raja gloss white. 0 Py Faces to be 3/16" 7328 white acrylic with 1" black Gemini 2025 trimcaps. Lighting to be bright white Hanley led modules attached with 3M VHB tape. Power supples to be Hanley 120 / 12 v. 1.1a premium power supplies. Letters mounted to EMS aluminum extruded raceway minimum 4 per letter #8 tech screws. Raceway fabricated of .125 aluminum to meet UL standards. Backs have inset track to accept 2" mounting clips. Clips to be spaced no more than 48" max. 1 top & 1 bottom with minimum 2 pair per raceway. 4 TOTAL Raceway painted to match wall section. UL Rated disconnect mounted to end of raceway Primary electrical feed in UL conduit connected to existing power supply to be provided. Wall section: Concrete Block Sign mounted to wall section with 3/8" hardware to be determined by wall type with minumum 2" embedment. expansion anchors (1) 20 amp 120V Circuit Req. This sign is to be installed in accordance with the requirements of Article 600 of the National Electrical Code. 1) Grounded and bonded per NEC 600.7/NEC 250 2) Existing branch circuit in compliance with NEC 600.5, not to exceed 20 amps 3) Sign is to be UL listed per NEC 600.3 4) UL disconnect switch per NEC 600.6- required per sign component before leaving manufacturer* *For multiple signs, a disconnect is permitted but not required for each section REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC �jj%IIullui/,i"/ ' 51GN TO BE INSTALLED ACCORDING .•DNS E'%ml TO 2017 NEC (N.F.P.A. 70) 600.3 &E ULTIMATE WIND VELOCITY = 170 MPH � \{ z` R15K CATEGORY II EXP05UKE C" �` 7th EDITION "2020 FBC" JOB TITLECARE NET ADDRESSr ORT ST LUCIE ©�®O 44445.E.COMMERC5i ►i, „�11;v```�� DAMES E. PAIT, P.E. REG#25497 NOTE: ALL ARTWORK & COLORS MUST BE 516NED OFF BEFORE ANY WORK 15 TO BEGIN , � STUART, FL. 84997 IF EXACT COLORS ARE REQUIRED OR MORE DETAILS PLEASE NOTE. CUSTOMER 15 772 220 7877 1963 5E PALM CITY RD 5TUART FL 34994 RESPON5113LE FOR ANY CHANGES ONCE WORK BEGINS. FAX 772 22 0 7768 PHONE 263-2677