HomeMy WebLinkAboutProduct Approval; Swinging Exterior Door Assemblies.6/3012021
Florida Building Code Online .
FL # FL22513-R3
Application Type Revision
Code Version 2020
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Product Approval Method
Masonite International
1955 Powis Road
West Chicago, IL 60185
(800) 663-3667
sschreiber@masonite.com
Steve Schreiber
sschreiber@masonite.com
Exterior Doors
Swinging Exterior Door Assemblies
Certification Mark or Listing
National Accreditation & Management Institute
National Accreditation & Management Institute
Standard
TAS 201
TAS 202
TAS 203
Method 1 Option A
Year
1994
1994
1994
File COPY
Date Submitted 11/06/2020
Date Validated 11/09/2020
Date Pending FBC Approval
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46QEOwOhYDnH I%2bvKgHKCWn2W NgFPQkSTNA%3d%3d
1/3
16/30/2021 Florida Building Code Online
Date Approved 11/17/2020
Summary of Products
�FL*
Model, Number or Name
Description
22513.1
HPC Wood -edge Steel Side -Hinged
6'-8" Glazed I/S or O/S Single or Double Door w/ or w/o
{
Door Unit
Sidelites
Limits of Use
Certification Agency Certificate _
Approved for use in HVHZ: Yes
FL22513 R3 C CAC NI013747.01-R2.pdf
j Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
06/30/2025
Design Pressure: +50/-50
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22513 R3 II FL0212.pdf
Building Code, including the High Velocity Hurricane Zone, and I
Verified By: National Accreditation & Management Institute
where pressure requirements do not exceed the design
Created by Independent Third Party:
pressures listed. 12'-0" x 6'-8" max nominal size. When impact
Evaluation Reports
i resistance is required, hurricane protective system is required.
FL22513 R3 AE 514008B.pdf
Door top rails stamped "HPC". See DWG-MA-FL0212 for details. I
Created by Independent Third Party: Yes
.......... - .................
22513.2
Wood -edge Steel Side -Hinged Door
_
8'-0" Opaque I/S or O/S Single Door Unit
Unit
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22513 R3 C CAC NIO13747.04-Rl.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes 1
06/30/2025 .
Design Pressure: +70/-70 1
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22513 R3 II FL0215.pdf
Building Code, including the High Velocity Hurricane Zone, and I
Verified By: National Accreditation & Management Institute
where pressure requirements do not exceed the design
Created by Independent Third Party:
I pressures listed. 3'-0" x 8'-0" max nominal size. When impact
Evaluation Reports
i resistance is required, hurricane protective system not I
FL22513 R3 AE 514009B.pdf
required. See DWG-MA-FL0215 for details.
Created by Independent Third Party: Yes
22513.3
Wood -edge Steel Side -Hinged Door '
8'-0" Opaque I/S Single or Double Door w/ or w/o Sidelites
Unit
i
Limits of Use — — _
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22513 R3 C CAC 1\1I013747.04-Rl.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
06/30/2025
Design Pressure: +45/-50
Installation Instructions
j Other: Evaluated for use in locations adhering to the Florida
FL22513 R3 II FL0215.pdf
i Building Code, including the High Velocity Hurricane Zone, and
Verified By: National Accreditation & Management Institute
i where pressure requirements do not exceed the design
Created by Independent Third Party:
pressures listed. 12'-0" x 8'-0" max nominal size. When impact
( Evaluation Reports
resistance is required, hurricane protective system not required
I FL22513 R3 AE 514007B.pdf
on opaque panels, but is required on glazed sidelites. See
Created by Independent Third Party: Yes
DWG-MA-FL0215 for details.
_
--
22513.4
__—...... __._................. -- —
Wood -edge Steel Side -Hinged Door
-- .... __.......--... _.
8'-0" Opaque O/S Single or Double Door w/ or w/o Sidelites
Unit
i
Limits of Use - _
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22513 R3 C CAC NI013747.04-Rl.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
06/30/2025
Design Pressure: +50/-45
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22513 R3 II FL0215.pdf
1 Building Code, including the High Velocity Hurricane Zone, and
' Verified By: National Accreditation & Management Institute
i
where pressure requirements do .not exceed the design
pressures listed. 12'-0" x 8'-0" max nominal size. When impact
Created by Independent Third Party:
Evaluation Reports
resistance is required, hurricane protective system not required
FL22513 R3 AE 514007B.pd
on opaque panels, but is required on glazed sidelites. See
Created by Independent Third Party: Yes
DWG-MA-FL0215 for details.
I
...... ...... ---
f 22513.5
Wood -edge Steel Side -Hinged Door
._-._..._...._._._
j 8'-0" 3/4-Lite Glazed I/S or O/S Single or Double Door w/ or
Unit
j w/o Sidelites
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22513 R3 C CAC NI013747.06-Rl.pdf
j Approved for use outside HVHZ: Yes
I Quality Assurance Contract Expiration Date
I Impact Resistant: No
i 06/30/2025
f Design Pressure: +40/-40
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22513 R3 II FL0217.pdf
Building Code, including the High Velocity Hurricane Zone, and
Verified By: National Accreditation & Management Institute
where pressure requirements do not exceed the design
Created by Independent Third Party:
pressures listed. 12'-0" x 8'-0" max nominal size. When impact
Evaluation Reports
resistance is required, hurricane protective system is required.
FL22513 R3 AE 514007B.pdf
See DWG-MA-FL0217 for details.
Created by Independent Third Party: Yes
_--- — —
22513.6
Wood -edge Steel Side -Hinged Door 6-8" Opaque I/S or O/S Single Door
hftps://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46QEOwOhYDnHI%2bvKgHKCWn2WNgFPQkSTNA%3d%3d 2/3
6/30/2021
Florida Building Code Online
lUnit
Limits of. Use
Certification Agency Certificate'
Approved for use in HVHZ: Yes
, FL22513 0 C CAC NI013747-R2.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
Design Pressure: +70/-70
06/30/2025
Installation Instructions,
Other: Evaluated for use in locations adhering to the Florida
FL22513 R3 II FL0211.pdf
Building Code, including the High Velocity Hurricane Zone, and
's Verified By: National Accreditation & Management Institute
where pressure requirements do not exceed the design
j Created by Independent Third Party:
pressures listed. 3'-0" x 6'-8" max nominal size. When impact
I Evaluation Reports
resistance is required, hurricane protective system not
FL22513 R3 AE 514010B.pdf
required. See DWG-MA-FLO211 for details.
Created by Independent Third Party: Yes
22513.7 Wood -edge Steel Side -Hinged Door
16'-8" Opaque I/S or O/S Single or Double Door w/ or w/o
Unit
I Sidelites
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22513 R3 C CAC NIO13747-R2.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
06/30/2025
i Design Pressure: +55/-55
Other: Evaluated for use in locations adhering to the Florida
Installation Instructions
FL22513 R3 II FL0211.pdf
Building Code, including the High Velocity Hurricane Zone, and
Verified By: National Accreditation & Management Institute
where pressure requirements do not exceed the design
Created by Independent Third Party:
pressures listed. 12'-0" x 6-8" max nominal size. When impact
I Evaluation Reports
j resistance is required, hurricane protective system not required
FL22513 R3 AE 514008B.pdf
on opaque panels, but is required on glazed sidelites. See
I Created by Independent Third Party: Yes
1 DWG-MA-FL0211 for details.
22513.8
Wood -edge Steel Side -Hinged Door
i 6'-8" 3/4-Lite Glazed I/S or O/S Single or Double Door w/ or
Unit
w/o Sidelites
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
I FL22513 R3 C CAC NI013747,03-R2,pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
Design Pressure: +50/-50
06/30/2025
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22513 R3 II FL0214.pdf
Building Code, including the High Velocity Hurricane Zone, and
i Verified By: National Accreditation & Management Institute
where pressure requirements do not exceed the design
Created by Independent Third Party:
pressures listed. 12'-0" x 6-8" max nominal size. When impact
i Evaluation Reports
resistance is required, hurricane protective system is required.
FL22513 R3 AE 514008B.pdf
See DWG-MA-FL0214 for details.
Created by Independent Third Party: Yes
Back EE
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Priva Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
Crodit Card
Safe
hfps://www.floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgtdytNblepz46QEOwOhYDnHI%2bvKgHKCWn2WNgFPQkSTNA%3d%3d 3/3
WOOD -EDGE STEEL DO•
6'-8" DOUBLE DOOR WITH/ WITHOUT SIDELITES
GOERAL Nt)TES
1. EVALUATED FOR USE IN LOCATIONS ADHERING TO
THE FLORIDA BUILDING CODE AND WHERE PRESSURE
REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM
DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES,
DOES NOT EXCEED THE DESIGN PRESSURES LISTED.
2. WHEN INSTALLED IN THE WIND—BORNE DEBRIS REGION
OR THE HIGH VELOCITY HURRICANE ZONE (HVHZ),
HURRICANE PROTECTIVE SYSTEM IS NOT REQUIRED ON OPAQUE
PANELS, BUT IS REQUIRED ON SIDELITES.
3. POLYURETHANE CORE FLAME SPREAD INDEX OF 50
AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84.
4. PLASTICS TESTING:
TFST nFSr_RIPTlnM nFc,,It.AIATiow IITF FRAMF
SELF . IGNITION TEMP
ASTM D1929
740 'F > 650 'F
RATE OF BURNING
ASTM D635
0.77 IN MIN
SMOKE DENSITY
ASTM D2843
13.47
TENSILE STRENGTH*
ASTM D638
7.17. DIFF
COMPARATIVE TENSILE STRENGTH AFTER WEATHERING
4500 HOURS XENON ARC METHOD 1
a
C9
F
co
CU
w �
C1
Lz
IN 10
F-1 rl I 1-il 1-ii �711' P-i] Fil [11
Fil Fli F! F! 1
Fil III lil lill i" I
SINGLE DOOR UNIT DOUBLE DOOR UNIT SINGLE DOOR UNIT
WITH SIDELITE
SINGLE DOOR UNIT
WITH SIDELITE
--- 149" MAX. %
21 " MAX 36.375" MAX.
D. L.O. —"� PANEL WIDTH -
W/ASTRAGAL
F_11,1
III Fil
SINGLE DOOR UNIT WLSIDELITE
3"
SEE DEN'
"C"
3"
#8x2"
#8x2"
6 - L SEE DETAIL 6"-1 �-ry
",Jl
#10 x 5/8»
#10 x 5/8
#10x2-1/2
DETAIL "C"
#10 x 1"
00 x 1"
2„
DETAIL "E" ASTRAGAL
ATTACH ASTRAGAL RETAINER BOLT
STRIKE PLATE TO FRAME
AS SHOWN.
DETAIL "D"
I _
ATTACHMENT DETAIL
1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED,
SIGNED AND SEALED BY ROBERTO LOMAS, PE
(FLORIDA #62514) WITH THE LOWEST (LEAST)
FASTENER RATING FROM THE DIFFERENT FASTENERS
BEING CONSIDERED FOR USE. JAMB, HEAD, AND
THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE
# 1 Q WOOD SCREWS OR 1 /4" TAPCONS. A PHYSICAL
SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR
LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2".
1n
MIN
a
CO
t
1sJ
C�
a SEE DETAIL
"D" SHT. 2
J
Q
Or
uj
3"
L6
3"
1. KWIKSET SERII
SERIES 980. C
AT 5-1 /2" C
2. 14" X 4" FULL
0.25"
SHIM 3X140MC
AND
TYPICAL MASONRY
ANCHOR INSTALLATION