Loading...
HomeMy WebLinkAbout214453-1d Compaction REVISED signedHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB #:214453-1d/JM/bm NUC #215 Nuc Model:MC-1DR-P Nuc Serial #:MD80404215 7828 Saddlebrook Drive Port St Lucie, Florida Compacted Foundation Fill - 1st Lift DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1 S.E.0" - 12"15D 116.0 117.4 98.8% 2 S.W."14D 114.3 "97.4% 3 Center "14D 115.3 "98.2% 4 N.W."14D 115.0 "98.0% 5 N.E."14D 115.5 "98.4% Proctor Optimum Moisture: Proctor Max. Dry Density: P.C.F. @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets 8/23/2021 Email to: bdgrading@att.net PE # 68366 Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Soil Description: JOB LOCATION: PERMIT #: CONTRACTOR:B & D Grading 2101-0652 Julie E. Keller, P.E. President Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Respectfully Submitted: ITEM TESTED: 117.4 TEST LOCATION OF SAMPLE Proudly Serving Florida since 1990 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test.KSM is not responsible if the tested area has been altered from the approved inspected condition. SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 July 13, 2021 August 23, 2021 DATE TESTED: 14.2% 11.0% Brown Sand with Clay REVISED: PERMIT ADDED Certified Women Owned Business - WBE Minimum Requirement for Staked Foundation In Place Moisture: 112.0 113.0 114.0 115.0 116.0 117.0 118.0 119.0 6 7 8 9 10 11 12 13 14 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight